Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Heart J ; 40(26): 2121-2127, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31046090

RESUMO

AIMS: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D). METHODS AND RESULTS: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10-42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3-45.5] and 97.2 (95% CI 85.5-109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79-1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45-2.44). Death due to progressive heart failure represented the principal cause of death (42.8% in CRT-P patients and 52.6% among CRT-D recipients), whereas approximately one-third of deaths in both device groups were due to non-cardiovascular death. CONCLUSION: In this first description of very long-term outcomes among CRT recipients, progressive heart failure death still represented the most frequent cause of death in patients surviving the first 5 years after CRT implant. In contrast, SCD represents a very low proportion of late mortality irrespective of the presence of a defibrillator.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Morte Súbita Cardíaca/epidemiologia , Idoso , Estudos de Coortes , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo
2.
Circ Arrhythm Electrophysiol ; 12(4): e007120, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30947511

RESUMO

BACKGROUND: The accuracy of ECG imaging (ECGI) in structural heart disease remains uncertain. This study aimed to provide a detailed comparison of ECGI and contact-mapping system (CARTO) electrograms. METHODS: Simultaneous epicardial mapping using CARTO (Biosense-Webster, CA) and ECGI (CardioInsight) in 8 patients was performed to compare electrogram morphology, activation time (AT), and repolarization time (RT). Agreement between AT and RT from CARTO and ECGI was assessed using Pearson correlation coefficient, ρ AT and ρ RT, root mean square error, E AT and E RT, and Bland-Altman plots. RESULTS: After geometric coregistration, 711 (439-905; median, first-third quartiles) ECGI and CARTO points were paired per patient. AT maps showed ρ AT=0.66 (0.53-0.73) and E AT=24 (21-32) ms, RT maps showed ρ RT=0.55 (0.41-0.71) and E RT=51 (38-70) ms. The median correlation coefficient measuring the morphological similarity between the unipolar electrograms was equal to 0.71 (0.65-0.74) for the entire signal, 0.67 (0.59-0.76) for QRS complexes, and 0.57 (0.35-0.76) for T waves. Local activation map correlation, ρ AT, was lower when default filters were used (0.60 (0.30-0.71), P=0.053). Small misalignment of the ECGI and CARTO geometries (below ±4 mm and ±4°) could introduce variations in the median ρ AT up to ±25%. Minimum distance between epicardial pacing sites and the region of earliest activation in ECGI was 13.2 (0.0-28.3) mm from 25 pacing sites with stimulation to QRS interval <40 ms. CONCLUSIONS: This simultaneous assessment demonstrates that ECGI maps activation and repolarization parameters with moderate accuracy. ECGI and contact electrogram correlation is sensitive to electrode apposition and geometric alignment. Further technological developments may improve spatial resolution.


Assuntos
Eletrocardiografia , Mapeamento Epicárdico , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA