Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38269244

RESUMO

The impact of fat on abdominal compression effectiveness in abdominal cancers was determined using magnetic resonance imaging (MRI). Visceral and subcutaneous fat were delineated on T2W 3D MRI, and motion change with compression was measured on 2D cine MRI. Results from 16 participants showed no correlation between fat percentage, body mass index (BMI), and motion change. Median BMI was 28.7 (SD, 4.9). Mean motion reduction was 7.8 mm (IQR, 5.0; p = 0.001) with compression. While no direct link was found between fat, BMI, and compression effectiveness, abdominal compression remains crucial for motion management in radiotherapy planning, providing dosimetric benefits.

2.
Phys Imaging Radiat Oncol ; 21: 78-83, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35243036

RESUMO

BACKGROUND: Patients who experience a pelvic cancer recurrence in or near a region that received initial radiotherapy, typically have few options for treatment. Organs at risk (OAR) have often reached their dose constraint limits leaving minimal dose remaining for standard re-irradiation (reRT). However, photon based stereotactic ablative radiotherapy (SABR) has been utilised for reRT with promising initial results although meeting OAR constraints can be challenging. Proton beam therapy (PBT) could offer an advantage. MATERIALS AND METHODS: SABR plans used for treatment for ten pelvic reRT patients were dosimetrically compared to PBT plans retrospectively planned using the same CT and contour data. PBT plans were created to match the CTV dose coverage of SABR treatment plans with V100% ≥95%. An 'as low as reasonably achievable' approach was taken to OAR tolerances with consideration of OAR dose from the initial radiation (using equivalent dose in 2 Gy fractions). RESULTS: Dosimetric comparison of relevant OAR statistics showed a decrease in OAR dose using PBT over SABR in all patients, with equivalent target coverage. The largest statistically significant reduction was seen for the colon D0.5 cm3 with a median reduction from 13.1 Gy to 5.9 Gy. There were statistically significant dose reductions in the median dose to small bowel, sacral plexus and cauda equina. CONCLUSION: PBT has the potential for significant dose reductions for OARs in the pelvic reRT setting compared to SABR. However, it remains unclear if the magnitude of these OAR dose reductions will translate into clinical benefit.

3.
Clin Oncol (R Coll Radiol) ; 33(10): e413-e421, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34001380

RESUMO

AIMS: So far, the impact of intra-thoracic anatomical changes (ITACs) on patients treated with stereotactic ablative radiotherapy (SABR) for early-stage non-small cell lung cancer is unknown. Studying these is important, as ITACs have the potential to impact the workflow and reduce treatment quality. The aim of this study was to assess and categorise ITACs, as detected on cone beam computed tomography scans (CBCT), and their subsequent impact upon treatment in lung cancer patients treated with SABR. MATERIALS AND METHODS: CBCTs from 100 patients treated with SABR for early non-small cell lung cancer were retrospectively reviewed. The presence of the following ITACs was assessed: atelectasis, infiltrative change, pleural effusion, baseline shift and gross tumour volume (GTV) increase and decrease. ITACs were graded using a traffic light protocol. This was adapted from a tool previously developed to assesses potential target undercoverage or organ at risk overdose. The frequency of physics or clinician review was noted. A linear mixed effects model was used to assess the relationship between ITAC grade and set-up time (time from first CBCT to beam delivery). RESULTS: ITACs were observed in 22% of patients. Twenty-one per cent of these were categorised as 'red', implying a risk of underdosage to the GTV. Most were 'yellow' (51%), indicating little impact upon planning target volume coverage of the GTV. Physics or clinician review was required in 10% of all treatment fractions overall. Three patients needed their treatment replanned. The mixed effect model analysis showed that ITACs cause a significant prolongation of set-up time (Χ2(3) = 9.22, P = 0.02). CONCLUSION: Most ITACs were minor, but associated with unplanned physics or clinician review, representing a potentially significant resource burden. ITACs also had a significant impact upon set-up time, with consequences for the wider workflow and intra-fraction motion. Detailed guidance on the management of ITACs is needed to provide support for therapeutic radiographers delivering lung SABR.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Estudos Retrospectivos
4.
Radiother Oncol ; 158: 112-117, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33636229

RESUMO

INTRODUCTION: Auto contouring models help consistently define volumes and reduce clinical workload. This study aimed to evaluate the cross acquisition of a Magnetic Resonance (MR) deep learning auto contouring model for organ at risk (OAR) delineation in head and neck radiotherapy. METHODS: Two auto contouring models were evaluated using deep learning contouring expert (DLCExpert) for OAR delineation: a CT model (modelCT) and an MR model (modelMRI). Models were trained to generate auto contours for the bilateral parotid glands and submandibular glands. Auto-contours for modelMRI were trained on diagnostic images and tested on 10 diagnostic, 10 MR radiotherapy planning (RTP), eight MR-Linac (MRL) scans and, by modelCT, on 10 CT planning scans. Goodness of fit scores, dice similarity coefficient (DSC) and distance to agreement (DTA) were calculated for comparison. RESULTS: ModelMRI contours improved the mean DSC and DTA compared with manual contours for the bilateral parotid glands and submandibular glands on the diagnostic and RTP MRs compared with the MRL sequence. There were statistically significant differences seen for modelMRI compared to modelCT for the left parotid (mean DTA 2.3 v 2.8 mm), right parotid (mean DTA 1.9 v 2.7 mm), left submandibular gland (mean DTA 2.2 v 2.4 mm) and right submandibular gland (mean DTA 1.6 v 3.2 mm). CONCLUSION: A deep learning MR auto-contouring model shows promise for OAR auto-contouring with statistically improved performance vs a CT based model. Performance is affected by the method of MR acquisition and further work is needed to improve its use with MRL images.


Assuntos
Aprendizado Profundo , Neoplasias de Cabeça e Pescoço , Cabeça , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Espectroscopia de Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador
5.
Med Phys ; 48(1): 414-426, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33164217

RESUMO

PURPOSE: Due to the electron return effect (ERE) during magnetic resonance imaging guided radiotherapy (MRIgRT), rectal gas during pelvic treatments can result in hot spots of over-dosage in the rectal wall. Determining the clinical impact of this effect on rectal toxicity requires estimation of the amount and mobility (and stability) of rectal gas during treatment. We therefore investigated the amount of rectal gas and local inter- and intra-fractional changes of rectal gas in pelvic cancer patients. METHODS: To estimate the volume of gas present at treatment planning, the rectal gas contents in the planning computed tomography (CT) scans of 124 bladder, 70 cervical and 2180 prostate cancer patients were calculated. To estimate inter- and intra-fractional variations in rectal gas, 174 and 131 T2-w MRIs for six cervical and eleven bladder cancer patients were used. These scans were acquired during four scan-sessions (~20-25 min each) at various time-points. Additionally, 258 T2-w MRIs of the first five prostate cancer patients treated using MRIgRT at our center, acquired during each fraction, were analyzed. Rectums were delineated on all scans. The area of gas within the rectum delineations was identified on each MRI slice using thresholding techniques. The area of gas on each slice of the rectum was used to calculate the inter- and intra-fractional group mean, systematic and random variations along the length of the rectum. The cumulative dose perturbation as a result of the gas was estimated. Two approaches were explored: accounting or not accounting for the gas at the start of the scan-session. RESULTS: Intra-fractional variations in rectal gas are small compared to the absolute volume of rectal gas detected for all patient groups. That is, rectal gas is likely to remain stable for periods of 20-25 min. Larger volumes of gas and larger variations in gas volume were observed in bladder cancer patients compared with cervical and prostate cancer patients. For all patients, local cumulative dose perturbations per beam over an entire treatment in the order of 60 % were estimated when gas had not been accounted for in the daily adaption. The calculated dose perturbation over the whole treatment was dramatically reduced in all patients when accounting for the gas in the daily set-up image. CONCLUSION: Rectal gas in pelvic cancer patients is likely to remain stable over the course of an MRIgRT fraction, and also likely to reappear in the same location in multiple fractions, and can therefore result in clinically relevant over-dosage in the rectal wall. The over-dosage is reduced when accounting for gas in the daily adaption.


Assuntos
Neoplasias Pélvicas , Neoplasias da Próstata , Radioterapia Guiada por Imagem , Humanos , Masculino , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reto/diagnóstico por imagem
6.
Med Phys ; 47(6): 2506-2515, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32145087

RESUMO

PURPOSE: Dose deposition around unplanned air cavities during magnetic resonance-guided radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically relevant for gas forming close to or inside organs at risk (OARs) that lie in the path of a single beam, for example, intestinal track during pelvic treatment. This work aims to verify Monte Carlo calculations that predict the dosimetric effects of ERE around air cavities. For this, we use GafChromic EBT3 film inside poly-methyl methacrylate (PMMA) -air phantoms. METHOD: Four PMMA phantoms were produced. Three of the phantoms contained centrally located spherical air cavities (0.5, 3.5, 7.5 cm diameter), and one phantom contained no air. The phantoms were split to sandwich GafChromic EBT3 film in the center. The phantoms were irradiated on an Elekta Unity system using a single 10 × 10 cm2 7-MV photon beam under the influence of a 1.5-T transverse magnetic field. The measurements were replicated using the Elekta Monaco treatment planning system (TPS). Gamma analysis with pass criteria 3%/3 mm was used to compare the measured and calculated dose distributions. We also consider 3%/2 mm, 2%/3 mm, and 2%/2 mm pass criteria for interest. RESULTS: The gamma analysis showed that >95% of the points agreed between the TPS-calculated and measured dose distributions, using 3%/3 mm criteria. The phantom containing the largest air cavity had the lowest agreement, with most of the disagreeing points lying inside the air cavity (dose to air region). CONCLUSIONS: The dose effects due to ERE around spherical air cavities are being calculated in the TPS with sufficient accuracy for clinical use.


Assuntos
Elétrons , Planejamento da Radioterapia Assistida por Computador , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
8.
Clin Oncol (R Coll Radiol) ; 34(3): 148-150, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34996685
9.
Can Fam Physician ; 33: 1067-70, 1987 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21263919
10.
Can Fam Physician ; 33: 1155-94, 1987 May.
Artigo em Inglês | MEDLINE | ID: mdl-21263927
11.
Can Fam Physician ; 32: 1723-4, 1986 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21267278
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA