Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Arthroplasty ; 30(10): 1705-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26024988

RESUMO

Decreasing hospital length of stay may attenuate costs associated with total knee arthroplasty. The purpose of this study was to determine if updates to an existing orthopedic enhanced recovery after surgery (ERAS) pathway would improve length of hospitalization. Clinical and demographic data were collected on 252 primary total knee arthroplasties between January 2012 and July 2013. Pre-updated and post-updated ERAS pathway cohorts were analyzed for length of stay, clinical outcomes, and re-admissions. The mean length of stay decreased from 76.6 hours to 56.1 hours after implementation of the evidence-based orthopedic enhanced recovery after surgery pathway (P<0.001). This improvement was possible without a concomitant increase in readmission rates.


Assuntos
Artroplastia do Joelho/reabilitação , Procedimentos Clínicos/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Idoso , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Ortopedia/estatística & dados numéricos , Estudos Retrospectivos
2.
J Biomech ; 43(11): 2203-7, 2010 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-20451913

RESUMO

The purpose of this study was to examine how a natural knee responds to the inputs of a total knee replacement testing standard developed by the International Organization for Standardization (ISO). This load control standard prescribes forces to be used for wear testing of knee replacements independent of implant size or design. A parallel ISO standard provides wear testing inputs that are displacement based instead of force based. Eight fresh frozen cadaveric knees were potted and tested in a 6 degree of freedom knee simulator using the load-control standard. The resulting displacements during load-control testing were compared to the prescribed displacements of the ISO displacement standard. At half the tibial torque prescribed by the load standard there was three times more average internal tibial rotation (20.3 degrees) than is prescribed by the displacement standard (5.7 degrees). The AP motion resulting from load testing was much different than is specified by the displacement standard. All eight knees had anterior tibial translation with respect to the femur during swing phase while the displacement standard specifies posterior tibial displacement. The variation in these motions among knees and their difference from the ISO displacement standard may be one factor that explains why wear results of total knee replacements based on ISO load or displacement testing frequently do not agree with each other or with clinical retrievals.


Assuntos
Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/normas , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Adulto , Idoso , Feminino , Humanos , Internacionalidade , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA