Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Card Surg ; 37(9): 2937-2942, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33533038

RESUMO

BACKGROUND: As transcatheter aortic valve replacement (TAVR) procedures increase, more data is available on the development of conduction abnormalities requiring permanent pacemaker (PPM) implantation post-TAVR. Mechanistically, new pacemaker implantation and incidence of associated tricuspid regurgitation (TR) post-TAVR is not well understood. Studies have evaluated the predictability of patient anatomy towards risk for needing permanent pacemaker (PPM) post-TAVR; however, little has been reported on new PPM and TR in patients post-TAVR. METHODS: This retrospective study identified patients at our health system who underwent PPM following TAVR from January 2014 to June 2018. Data from both TAVR and PPM procedures as well as patient demographics were collected. Echocardiographic data before TAVR, between TAVR and PPM placement, and the most recent echocardiogram at the time of chart review were analyzed. RESULTS: Of 796 patients who underwent TAVR between January 2014 and June 2018, 89 patients (11%) subsequently required PPM. Out of the 89 patients who required PPM implantation, 82 patients had pre-TAVR and 2-year post-TAVR echocardiographic imaging data. At baseline, 22% (18/82) of patients had at least moderate TR. At 2-year post-TAVR echocardiographic imaging follow-up; 27% (22/82) of patients had at least moderate TR. Subgroup analysis was performed according to the TAVR valve size implanted. In patients who received a TAVR device < 29 mm in diameter in size, 25% (11/44) had worsening TR. In patients who received a TAVR device ≥ 29 mm in diameter, 37% (14/38) had worsening TR. CONCLUSION: We have demonstrated a patient population that may be predisposed to developing worsening TR and right heart function after TAVR and Pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA