Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Hum Genet ; 136(10): 1341-1351, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28780673

RESUMO

Growing evidence from both epidemiology and basic science suggest an inverse association between Alzheimer's disease (AD) and cancer. We examined the genetic relationship between AD and various cancer types using GWAS summary statistics from the IGAP and GAME-ON consortia. Sample size ranged from 9931 to 54,162; SNPs were imputed to the 1000 Genomes European panel. Our results based on cross-trait LD Score regression showed a significant positive genetic correlation between AD and five cancers combined (colon, breast, prostate, ovarian, lung; r g = 0.17, P = 0.04), and specifically with breast cancer (ER-negative and overall; r g = 0.21 and 0.18, P = 0.035 and 0.034) and lung cancer (adenocarcinoma, squamous cell carcinoma and overall; r g = 0.31, 0.38 and 0.30, P = 0.029, 0.016, and 0.006). Estimating the genetic correlation in specific functional categories revealed mixed positive and negative signals, notably stronger at annotations associated with increased enhancer activity. This suggests a role of gene expression regulators in the shared genetic etiology between AD and cancer, and that some shared variants modulate disease risk concordantly while others have effects in opposite directions. Due to power issues, we did not detect cross-phenotype associations at individual SNPs. This genetic overlap is not likely driven by a handful of major loci. Our study is the first to examine the co-heritability of AD and cancer leveraging large-scale GWAS results. The functional categories highlighted in this study need further investigation to illustrate the details of the genetic sharing and to bridge between different levels of associations.


Assuntos
Doença de Alzheimer/genética , Estudo de Associação Genômica Ampla , Neoplasias/genética , Polimorfismo de Nucleotídeo Único , Doença de Alzheimer/epidemiologia , Feminino , Humanos , Masculino , Neoplasias/epidemiologia
2.
Am Heart J ; 179: 19-28, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27595676

RESUMO

RESCUE is a phase III, randomized, controlled, multicenter, comparative efficacy study, designed to compare two diagnostic imaging/treatment paradigms that use coronary computed tomography angiography (CCTA) or single photon emission computed tomography myocardial perfusion imaging (SPECT MPI) for assisting in the diagnosis of ischemic heart disease in patients with stable angina symptoms, and guiding subsequent treatment. The study is based on the hypothesis that CCTA as a diagnostic tool is associated with no increase in cardiac risk, decreased cost, and reduced radiation exposure compared with SPECT MPI. The RESCUE trial was funded by the Agency for Healthcare Research and Quality (AHRQ) and the American College of Radiology Imaging Network (ACRIN) Fund for Imaging Innovation, began in 2011, and completed in 2014.


Assuntos
Angina Estável/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Estável/terapia , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Dietoterapia , Exercício Físico , Feminino , Cardiopatias/mortalidade , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Isquemia Miocárdica/terapia , Revascularização Miocárdica/estatística & dados numéricos , Inibidores da Agregação Plaquetária/uso terapêutico , Abandono do Hábito de Fumar , Fatores de Tempo , Vasodilatadores/uso terapêutico
3.
Radiology ; 268(3): 673-83, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23616634

RESUMO

PURPOSE: To determine prospectively the prevalence and rate of malignancy of multiple bilateral (MB) circumscribed breast masses detected at screening ultrasonography (US) compared with those of other US-depicted masses. MATERIALS AND METHODS: This institutional review board-approved, HIPAA-compliant prospective trial included women at elevated risk for breast cancer, who gave written informed consent to participate in a study evaluating cancer detection rates for three rounds of annual supplemental screening US at 21 international sites. After exclusions, 2662 participants and 7473 screening studies were included. Physician-performed US studies were interpreted, with blinding to mammography results. Simple cysts were noted. Breast Imaging Reporting and Data System features of all other findings were recorded, with addition of the descriptor MB similar-appearing circumscribed masses (minimum of three total and at least one in each breast), with details of the largest such mass recorded. Rates of malignancy were determined after biopsy or mammographic and US follow-up at a minimum of 11 months. For this analysis, 490 women (1370 screenings) with prior mastectomy were excluded. Descriptive statistics and exact 95% confidence intervals (CIs) were generated. RESULTS: Of 2172 evaluable participants (6103 screening studies; median age at study entry, 54.0 years; range, 25-91 years), 1454 had unique findings at US. One hundred thirty-five (6.2%) participants had 153 unique MB circumscribed masses, with no malignancies (0% [95% CI: 0%, 2.4%]; 95% CI: 0%, 2.9% for the 127 masses with at least 2 years of follow-up). There were 1319 (60.7%) participants with 2464 non-MB lesions, including 1038 solitary circumscribed masses with a malignancy rate of 0.8% (eight of 1038). Of 836 solitary circumscribed masses with at least 2 years of follow-up, the malignancy rate was 0.4% (three of 836; 95% CI: 0.1%, 1.0%). Of the 135 women with MB circumscribed masses, 82 (60.7%) also had a solitary lesion. Two of these 82 women (2.4%) had cancer. CONCLUSION: MB similar-appearing circumscribed masses seen at screening US are almost always benign, with no malignancies found among such lesions in this prospective, multicenter experience. These lesions are suitable for diagnostic follow-up in 1 year, with resumption of screening thereafter if they are stable.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Programas de Rastreamento/estatística & dados numéricos , Ultrassonografia Mamária/estatística & dados numéricos , Adulto , Idoso , Neoplasias da Mama/prevenção & controle , Feminino , Seguimentos , Humanos , Incidência , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
4.
Radiology ; 269(3): 701-12, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23962417

RESUMO

PURPOSE: To prospectively validate predefined breast ultrasonographic (US) Breast Imaging Reporting and Data System (BI-RADS) category 3 criteria in a multicenter setting in an elevated-risk population. MATERIALS AND METHODS: The American College of Radiology Imaging Network 6666 database was reviewed for prospectively defined BI-RADS category 3 lesions. Patient characteristics, lesion US features at initial detection, and work-up recommendations were analyzed with descriptive statistics. Exact 95% confidence intervals (CIs) were given, where appropriate. Lesion reference standard was biopsy or a minimum of 1-year follow-up. In addition, malignancy rate for lesions that had at least 2 years of follow-up data or that had biopsy data was calculated. RESULTS: Of 2662 participants, 519 (19.5%) had 745 BI-RADS category 3 lesions (25.5% of 2916 US lesions other than simple cysts), with a median size of 7 mm (range, 2-135 mm). The number of new BI-RADS category 3 lesions decreased with year 2-3 screening, but the percentage of new BI-RADS category 3 lesions was stable at 26.4% (506 of 1920 lesions), 23.6% (142 of 601 lesions), and 24.6% (97 of 395 lesions), respectively. Of 745 BI-RADS category 3 lesions, 124 (16.6%) were ultimately sampled for biopsy. Six malignancies (0.8% of BI-RADS category 3 lesions; 95% confidence interval [CI]: 0.3%, 1.7%) occurred in five (1.0%) of 519 participants: Five malignancies were invasive (median size, 10 mm; size range, 2-18 mm), and one was node positive. When the analysis is limited to lesions with at least 2-year follow-up or biopsy, the malignancy rate among BI-RADS category 3 lesions is 0.9% (95% CI: 0.3%, 2.0%). Three malignant BI-RADS category 3 lesions were sampled for biopsy because of a suspicious change at follow-up (two N0 lesions, one each at 6- and 12-month follow-up; one N1 lesion at 24-month follow-up), one was sampled for biopsy because of an upgrade after additional mammography (NX), one was found at mastectomy for another cancer (N0), and one was found at prophylactic contralateral mastectomy in the same patient (NX). CONCLUSION: As BI-RADS category 3 lesions have a low malignancy rate (0.8%; 95% CI: 0.3%, 1.7%) and only 0.1% of the cancers had suspicious changes at 6-month follow-up and only one (17%; 95% CI: 0.4%, 64%) of six malignancies were node positive at detection (24-month follow-up), a recommendation of 1-year diagnostic follow-up may be appropriate for BI-RADS category 3 lesions detected at screening US. Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia Mamária , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Reações Falso-Positivas , Feminino , Humanos , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Estados Unidos/epidemiologia
5.
AJR Am J Roentgenol ; 199(1): 224-35, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733916

RESUMO

OBJECTIVE: Qualification tasks in mammography and breast ultrasound were developed for the American College of Radiology Imaging Network (ACRIN) 6666 Investigators. We sought to assess the effects of feedback on breast ultrasound interpretive performance and agreement in BI-RADS feature analysis among a subset of these experienced observers. MATERIALS AND METHODS: After a 1-hour didactic session on BI-RADS: Ultrasound, an interpretive skills quiz set of 70 orthogonal sets of breast ultrasound images including 25 (36%) malignancies was presented to 100 experienced breast imaging observers. Thirty-five observers reviewed the quiz set twice: first without and then with immediate feedback of consensus feature analysis, management recommendations, and pathologic truth. Observer performance (sensitivity, specificity, area under the curve [AUC]) was calculated without feedback and with feedback. Kappas were determined for agreement on feature analysis and assessments. RESULTS: For 35 observers without feedback, the mean sensitivity was 89% (range, 68-100%); specificity, 62% (range, 42-82%); and AUC, 82% (range, 73-89%). With feedback, the mean sensitivity was 93% (range, 80-100%; mean increase, 4%; range of increase, 0-12%; p < 0.0001), the mean specificity was 61% (range, 45-73%; mean decrease, 1%; range of change, -18% to 11%; p = 0.19), and the mean AUC was 84% (range, 78-90%; mean increase, 2%; range of change, -3% to 9%; p < 0.0001). Three breast imagers in the lowest quartile of initial performance showed the greatest improvement in sensitivity with no change or improvement in AUC. The kappa values for feature analysis did not change, but there was improved agreement about final assessments, with the kappa value increasing from 0.53 (SE, 0.02) without feedback to 0.59 (SE, 0.02) with feedback (p < 0.0001). CONCLUSION: Most experienced breast imagers showed excellent breast ultrasound interpretive skills. Immediate feedback of consensus BI-RADS: Ultrasound features and histopathologic results improved performance in ultrasound interpretation across all experience variables.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Padrões de Prática Médica/estatística & dados numéricos , Pesquisadores/estatística & dados numéricos , Ultrassonografia Mamária/métodos , Ultrassonografia Mamária/estatística & dados numéricos , Área Sob a Curva , Biópsia , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Retroalimentação , Feminino , Seguimentos , Humanos , Modelos Estatísticos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Pesquisadores/educação , Sensibilidade e Especificidade , Análise e Desempenho de Tarefas , Estados Unidos
6.
JAMA ; 307(13): 1394-404, 2012 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-22474203

RESUMO

CONTEXT: Annual ultrasound screening may detect small, node-negative breast cancers that are not seen on mammography. Magnetic resonance imaging (MRI) may reveal additional breast cancers missed by both mammography and ultrasound screening. OBJECTIVE: To determine supplemental cancer detection yield of ultrasound and MRI in women at elevated risk for breast cancer. DESIGN, SETTING, AND PARTICIPANTS: From April 2004-February 2006, 2809 women at 21 sites with elevated cancer risk and dense breasts consented to 3 annual independent screens with mammography and ultrasound in randomized order. After 3 rounds of both screenings, 612 of 703 women who chose to undergo an MRI had complete data. The reference standard was defined as a combination of pathology (biopsy results that showed in situ or infiltrating ductal carcinoma or infiltrating lobular carcinoma in the breast or axillary lymph nodes) and 12-month follow-up. MAIN OUTCOME MEASURES: Cancer detection rate (yield), sensitivity, specificity, positive predictive value (PPV3) of biopsies performed and interval cancer rate. RESULTS: A total of 2662 women underwent 7473 mammogram and ultrasound screenings, 110 of whom had 111 breast cancer events: 33 detected by mammography only, 32 by ultrasound only, 26 by both, and 9 by MRI after mammography plus ultrasound; 11 were not detected by any imaging screen. Among 4814 incidence screens in the second and third years combined, 75 women were diagnosed with cancer. Supplemental incidence-screening ultrasound identified 3.7 cancers per 1000 screens (95% CI, 2.1-5.8; P < .001). Sensitivity for mammography plus ultrasound was 0.76 (95% CI, 0.65-0.85); specificity, 0.84 (95% CI, 0.83-0.85); and PPV3, 0.16 (95% CI, 0.12-0.21). For mammography alone, sensitivity was 0.52 (95% CI, 0.40-0.64); specificity, 0.91 (95% CI, 0.90-0.92); and PPV3, 0.38 (95% CI, 0.28-0.49; P < .001 all comparisons). Of the MRI participants, 16 women (2.6%) had breast cancer diagnosed. The supplemental yield of MRI was 14.7 per 1000 (95% CI, 3.5-25.9; P = .004). Sensitivity for MRI and mammography plus ultrasound was 1.00 (95% CI, 0.79-1.00); specificity, 0.65 (95% CI, 0.61-0.69); and PPV3, 0.19 (95% CI, 0.11-0.29). For mammography and ultrasound, sensitivity was 0.44 (95% CI, 0.20-0.70, P = .004); specificity 0.84 (95% CI, 0.81-0.87; P < .001); and PPV3, 0.18 (95% CI, 0.08 to 0.34; P = .98). The number of screens needed to detect 1 cancer was 127 (95% CI, 99-167) for mammography; 234 (95% CI, 173-345) for supplemental ultrasound; and 68 (95% CI, 39-286) for MRI after negative mammography and ultrasound results. CONCLUSION: The addition of screening ultrasound or MRI to mammography in women at increased risk of breast cancer resulted in not only a higher cancer detection yield but also an increase in false-positive findings. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00072501.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Reações Falso-Positivas , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
7.
J Am Heart Assoc ; 10(9): e018481, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33899501

RESUMO

Background Premature discontinuation of dual antiplatelet therapy (DAPT) after percutaneous coronary intervention is related to higher short-term risks of adverse outcomes. Whether these risks persist in the long-term is uncertain. Methods and Results We assessed all patients having percutaneous coronary intervention with coronary second- or first-generation drug-eluting stents in the Veterans Affairs healthcare system between 2006 and 2012 who were free of major ischemic or bleeding events in the first 12 months. The characteristics of patients who stopped DAPT prematurely (1-9 months duration), compared with >9 to 12 months, or extended duration (>12 months) were assessed by odds ratios (ORs) from multivariable logistic models. The risk of adverse clinical outcomes over a mean 5.1 years in patients who stopped DAPT prematurely was assessed by hazard ratios (HRs) and 95% CIs from Cox regression models. A total of 14 239 had second-generation drug-eluting stents, and 8583 had first-generation drug-eluting stents. Premature discontinuation of DAPT was more likely in Black patients (OR, 1.54; 95% CI, 1.40-1.68), patients with greater frailty (OR, 1.04; 95% CI, 1.03-1.05), and patients with higher low-density lipoprotein cholesterol, and less likely in patients on statins (OR, 0.87; 95% CI, 0.80-0.95). Patients who stopped DAPT prematurely had higher long-term risks of death (second-generation drug-eluting stents: HR, 1.35; 95% CI, 1.19-1.56), myocardial infarction (second-generation drug-eluting stents: HR, 1.46; 95% CI, 1.22-1.74), and repeated coronary revascularization (second-generation drug-eluting stents: HR, 1.24; 95% CI, 1.08-1.41). Conclusions Patients who stop DAPT prematurely have features that reflect greater frailty, poorer medication use, and other social factors. They continue to have higher risks of major adverse outcomes over the long-term and may require more intensive surveillance many years after percutaneous coronary intervention.


Assuntos
Doença da Artéria Coronariana/terapia , Terapia Antiplaquetária Dupla/métodos , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Stents , Veteranos , Suspensão de Tratamento/normas , Esquema de Medicação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Estudos Retrospectivos , Fatores de Risco , Estados Unidos/epidemiologia
8.
J Am Heart Assoc ; 9(24): e017993, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33283579

RESUMO

Background The RESCUE (Randomized Evaluation of Patients with Stable Angina Comparing Utilization of Noninvasive Examinations) trial was a randomized, controlled, multicenter, comparative efficacy outcomes trial designed to assess whether initial testing with coronary computed tomographic angiography (CCTA) is noninferior to single photon emission computed tomography (SPECT) myocardial perfusion imaging in directing patients with stable angina to optimal medical therapy alone or optimal medical therapy with revascularization. Methods and Results The end point was first major adverse cardiovascular event (MACE) (cardiac death or myocardial infarction), or revascularization. Noninferiority margin for CCTA was set a priori as a hazard ratio (HR) of 1.3 (95% CI=0, 1.605). One thousand fifty participants from 44 sites were randomized to CCTA (n=518) or SPECT (n=532). Mean follow-up time was 16.2 (SD 7.9) months. There were no cardiac-related deaths. In patients with a negative CCTA there was 1 acute myocardial infarction; in patients with a negative SPECT examination there were 2 acute myocardial infarctions; and for positive CCTA and SPECT, 1 acute myocardial infarction each. Participants in the CCTA arm had a similar rate of MACE or revascularization compared with those in the SPECT myocardial perfusion imaging arm, (HR, 1.03; 95% CI=0.61-1.75) (P=0.19). CCTA segment involvement by a stenosis of ≥50% diameter was a better predictor of MACE and revascularization at 1 year (P=0.02) than the percent reversible defect size by SPECT myocardial perfusion imaging. Four (1.2%) patients with negative CCTA compared with 14 (3.2%) with negative SPECT had MACE or revascularization (P=0.03). Conclusions There was no difference in outcomes of patients who had stable angina and who underwent CCTA in comparison to SPECT as the first imaging test directing them to optimal medical therapy alone or with revascularization. CCTA was a better predictor of MACE and revascularization. Registration Information URL: https://www.clinicaltrials.gov/. Identifier: NCT01262625.


Assuntos
Angina Estável/terapia , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Angina Estável/classificação , Angina Estável/diagnóstico , Doenças Cardiovasculares/epidemiologia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Morte , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/epidemiologia , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
9.
Radiology ; 251(1): 122-33, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19332850

RESUMO

PURPOSE: To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer. MATERIALS AND METHODS: This prospective multicenter study, conducted by the American College of Radiology Imaging Network (ACRIN) from February 2004 to June 2005, was institutional review board approved and HIPAA compliant. Research associates were required to follow consent guidelines approved by the Office for Human Research Protection and established by the institutional review boards. One hundred thirty-four patients with biopsy-proved prostate adenocarcinoma and scheduled to undergo radical prostatectomy were recruited at seven institutions. T1-weighted, T2-weighted, and spectroscopic MR sequences were performed at 1.5 T by using a pelvic phased-array coil in combination with an endorectal coil. Eight readers independently rated the likelihood of the presence of PZ cancer in each sextant by using a five-point scale-first on MR images alone and later on combined MR-MR spectroscopic images. Areas under the receiver operating characteristic curve (AUCs) were calculated with sextant as the unit of analysis. The presence or absence of cancer at centralized histopathologic evaluation of prostate specimens was the reference standard. Reader-specific receiver operating characteristic curves for values obtained with MR imaging alone and with combined MR imaging-MR spectroscopic imaging were developed. The AUCs were estimated by using Mann-Whitney statistics and appropriate 95% confidence intervals. RESULTS: Complete data were available for 110 patients (mean age, 58 years; range, 45-72 years). MR imaging alone and combined MR imaging-MR spectroscopic imaging had similar accuracy in PZ cancer localization (AUC, 0.60 vs 0.58, respectively; P > .05). AUCs for individual readers were 0.57-0.63 for MR imaging alone and 0.54-0.61 for combined MR imaging-MR spectroscopic imaging. CONCLUSION: In patients who undergo radical prostatectomy, the accuracy of combined 1.5-T endorectal MR imaging-MR spectroscopic imaging for sextant localization of PZ prostate cancer is equal to that of MR imaging alone.


Assuntos
Imageamento por Ressonância Magnética/métodos , Prostatectomia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/cirurgia , Idoso , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
10.
Radiology ; 246(2): 376-83, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18227537

RESUMO

PURPOSE: To retrospectively compare the accuracy of digital versus film mammography in population subgroups of the Digital Mammographic Imaging Screening Trial (DMIST) defined by combinations of age, menopausal status, and breast density, by using either biopsy results or follow-up information as the reference standard. MATERIALS AND METHODS: DMIST included women who underwent both digital and film screening mammography. Institutional review board approval at all participating sites and informed consent from all participating women in compliance with HIPAA was obtained for DMIST and this retrospective analysis. Areas under the receiver operating characteristic curve (AUCs) for each modality were compared within each subgroup evaluated (age < 50 vs 50-64 vs >or= 65 years, dense vs nondense breasts at mammography, and pre- or perimenopausal vs postmenopausal status for the two younger age cohorts [10 new subgroups in toto]) while controlling for multiple comparisons (P < .002 indicated a significant difference). All DMIST cancers were evaluated with respect to mammographic detection method (digital vs film vs both vs neither), mammographic lesion type (mass, calcifications, or other), digital machine type, mammographic and pathologic size and diagnosis, existence of prior mammographic study at time of interpretation, months since prior mammographic study, and compressed breast thickness. RESULTS: Thirty-three centers enrolled 49 528 women. Breast cancer status was determined for 42,760 women, the group included in this study. Pre- or perimenopausal women younger than 50 years who had dense breasts at film mammography comprised the only subgroup for which digital mammography was significantly better than film (AUCs, 0.79 vs 0.54; P = .0015). Breast Imaging Reporting and Data System-based sensitivity in this subgroup was 0.59 for digital and 0.27 for film mammography. AUCs were not significantly different in any of the other subgroups. For women aged 65 years or older with fatty breasts, the AUC showed a nonsignificant tendency toward film being better than digital mammography (AUCs, 0.88 vs 0.70; P = .0025). CONCLUSION: Digital mammography performed significantly better than film for pre- and perimenopausal women younger than 50 years with dense breasts, but film tended nonsignificantly to perform better for women aged 65 years or older with fatty breasts.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Mamografia/estatística & dados numéricos , Programas de Rastreamento/estatística & dados numéricos , Intensificação de Imagem Radiográfica , Filme para Raios X/estatística & dados numéricos , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Canadá/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
11.
JAMA ; 299(18): 2151-63, 2008 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-18477782

RESUMO

CONTEXT: Screening ultrasound may depict small, node-negative breast cancers not seen on mammography. OBJECTIVE: To compare the diagnostic yield, defined as the proportion of women with positive screen test results and positive reference standard, and performance of screening with ultrasound plus mammography vs mammography alone in women at elevated risk of breast cancer. DESIGN, SETTING, AND PARTICIPANTS: From April 2004 to February 2006, 2809 women, with at least heterogeneously dense breast tissue in at least 1 quadrant, were recruited from 21 sites to undergo mammographic and physician-performed ultrasonographic examinations in randomized order by a radiologist masked to the other examination results. Reference standard was defined as a combination of pathology and 12-month follow-up and was available for 2637 (96.8%) of the 2725 eligible participants. MAIN OUTCOME MEASURES: Diagnostic yield, sensitivity, specificity, and diagnostic accuracy (assessed by the area under the receiver operating characteristic curve) of combined mammography plus ultrasound vs mammography alone and the positive predictive value of biopsy recommendations for mammography plus ultrasound vs mammography alone. RESULTS: Forty participants (41 breasts) were diagnosed with cancer: 8 suspicious on both ultrasound and mammography, 12 on ultrasound alone, 12 on mammography alone, and 8 participants (9 breasts) on neither. The diagnostic yield for mammography was 7.6 per 1000 women screened (20 of 2637) and increased to 11.8 per 1000 (31 of 2637) for combined mammography plus ultrasound; the supplemental yield was 4.2 per 1000 women screened (95% confidence interval [CI], 1.1-7.2 per 1000; P = .003 that supplemental yield is 0). The diagnostic accuracy for mammography was 0.78 (95% CI, 0.67-0.87) and increased to 0.91 (95% CI, 0.84-0.96) for mammography plus ultrasound (P = .003 that difference is 0). Of 12 supplemental cancers detected by ultrasound alone, 11 (92%) were invasive with a median size of 10 mm (range, 5-40 mm; mean [SE], 12.6 [3.0] mm) and 8 of the 9 lesions (89%) reported had negative nodes. The positive predictive value of biopsy recommendation after full diagnostic workup was 19 of 84 for mammography (22.6%; 95% CI, 14.2%-33%), 21 of 235 for ultrasound (8.9%, 95% CI, 5.6%-13.3%), and 31 of 276 for combined mammography plus ultrasound (11.2%; 95% CI. 7.8%-15.6%). CONCLUSIONS: Adding a single screening ultrasound to mammography will yield an additional 1.1 to 7.2 cancers per 1000 high-risk women, but it will also substantially increase the number of false positives. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00072501.


Assuntos
Neoplasias da Mama/diagnóstico , Mamografia , Ultrassonografia Mamária , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Humanos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Sensibilidade e Especificidade
12.
Int J Radiat Oncol Biol Phys ; 67(4): 972-5, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17208386

RESUMO

PURPOSE: Accurate target definition is considered essential for sophisticated, image-guided radiation therapy; however, relatively little information has been reported that measures our ability to identify the precise shape of targets accurately. We decided to assess the manner in which eight "experts" interpreted the size and shape of tumors based on "real-life" contrast-enhanced computed tomographic (CT) scans. METHODS AND MATERIALS: Four neuroradiologists and four radiation oncologists (the authors) with considerable experience and presumed expertise in treating head-and-neck tumors independently contoured, slice-by-slice, his/her interpretation of the precise gross tumor volume (GTV) on each of 20 sets of CT scans taken from 20 patients who previously were enrolled in Radiation Therapy Oncology Group protocol 91-11. RESULTS: The average proportion of overlap (i.e., the degree of agreement) was 0.532 (95% confidence interval 0.457 to 0.606). There was a slight tendency for the proportion of overlap to increase with increasing average GTV. CONCLUSIONS: Our work suggests that estimation of tumor shape currently is imprecise, even for experienced physicians. In consequence, there appears to be a practical limit to the current trend of smaller fields and tighter margins.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias Laríngeas/diagnóstico por imagem , Variações Dependentes do Observador , Radioterapia (Especialidade)/normas , Tomografia Computadorizada por Raios X , Competência Clínica , Feminino , Humanos , Masculino , Neurologia/normas
13.
Neurology ; 89(18): 1877-1885, 2017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-28954880

RESUMO

OBJECTIVE: To determine whether metformin is associated with a lower incidence of dementia than sulfonylureas. METHODS: This was a retrospective cohort study of US veterans ≥65 years of age with type 2 diabetes who were new users of metformin or a sulfonylurea and had no dementia. Follow-up began after 2 years of therapy. To account for confounding by indication, we developed a propensity score (PS) and used inverse probability of treatment weighting (IPTW) methods. Cox proportional hazards models estimated the hazard ratio (HR) of incident dementia. RESULTS: We identified 17,200 new users of metformin and 11,440 new users of sulfonylureas. Mean age was 73.5 years and mean HbA1c was 6.8%. Over an average follow-up of 5 years, 4,906 cases of dementia were diagnosed. Due to effect modification by age, all analyses were conducted using a piecewise model for age. Crude hazard ratio [HR] for any dementia in metformin vs sulfonylurea users was 0.67 (95% confidence interval [CI] 0.61-0.73) and 0.78 (95% CI 0.72-0.83) for those <75 years of age and ≥75 years of age, respectively. After PS IPTW adjustment, results remained significant in veterans <75 years of age (HR 0.89; 95% CI 0.79-0.99), but not for those ≥75 years of age (HR 0.96; 95% CI 0.87-1.05). A lower risk of dementia was also seen in the subset of younger veterans who had HbA1C values ≥7% (HR 0.76; 95% CI 0.63-0.91), had good renal function (HR 0.86; 95% CI 0.76-0.97), and were white (HR 0.87; 95% CI 0.77-0.99). CONCLUSIONS: After accounting for confounding by indication, metformin was associated with a lower risk of subsequent dementia than sulfonylurea use in veterans <75 years of age. Further work is needed to identify which patients may benefit from metformin for the prevention of dementia.


Assuntos
Demência/induzido quimicamente , Demência/epidemiologia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Metformina/efeitos adversos , Compostos de Sulfonilureia/efeitos adversos , Veteranos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais , Estados Unidos/epidemiologia
14.
J Nucl Med ; 56(11): 1681-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26359256

RESUMO

UNLABELLED: Our objective was to determine whether early change in standardized uptake values (SUVs) of 3'deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) using PET with CT could predict pathologic complete response (pCR) of primary breast cancer to neoadjuvant chemotherapy (NAC). The key secondary objective was to correlate SUV with the proliferation marker Ki-67 at baseline and after NAC. METHODS: This prospective, multicenter phase II study did not specify the therapeutic regimen, thus, NAC varied among centers. All evaluable patients underwent (18)F-FLT PET/CT at baseline (FLT1) and after 1 cycle of NAC (FLT2); 43 patients were imaged at FLT1, FLT2, and after NAC completion (FLT3). The percentage change in maximum SUV (%ΔSUVmax) between FLT1 and FLT2 and FLT3 was calculated for the primary tumors. The predictive value of ΔSUVmax for pCR was determined using receiver-operating-characteristic curve analysis. The correlation between SUVmax and Ki-67 was also assessed. RESULTS: Fifty-one of 90 recruited patients (median age, 54 y; stage IIA-IIIC) met the eligibility criteria for the primary objective analysis, with an additional 22 patients totaling 73 patients for secondary analyses. A pCR in the primary breast cancer was achieved in 9 of 51 patients. NAC resulted in a significant reduction in %SUVmax (mean Δ, 39%; 95% confidence interval, 31-46). There was a marginal difference in %ΔSUVmax_FLT1-FLT2 between pCR and no-pCR patient groups (Wilcoxon 1-sided P = 0.050). The area under the curve for ΔSUVmax in the prediction of pCR was 0.68 (90% confidence interval, 0.50-0.83; Delong 1-sided P = 0.05), with slightly better predictive value for percentage mean SUV (P = 0.02) and similar prediction for peak SUV (P = 0.04). There was a weak correlation with pretherapy SUVmax and Ki-67 (r = 0.29, P = 0.04), but the correlation between SUVmax and Ki-67 after completion of NAC was stronger (r = 0.68, P < 0.0001). CONCLUSION: (18)F-FLT PET imaging of breast cancer after 1 cycle of NAC weakly predicted pCR in the setting of variable NAC regimens. Posttherapy (18)F-FLT uptake correlated with Ki-67 on surgical specimens. These results suggest some efficacy of (18)F-FLT as an indicator of early therapeutic response of breast cancer to NAC and support future multicenter studies to test (18)F-FLT PET in a more uniformly treated patient population.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Didesoxinucleosídeos , Terapia Neoadjuvante/métodos , Compostos Radiofarmacêuticos , Neoplasias da Mama/patologia , Didesoxinucleosídeos/efeitos adversos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Antígeno Ki-67 , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Compostos Radiofarmacêuticos/efeitos adversos , Resultado do Tratamento
15.
Eur Radiol ; 18(8): 1720-6, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18389247

RESUMO

Posterior fossa artifacts constitute a characteristic limitation of cranial CT. To identify practical benefits and drawbacks of newer CT systems with reduced collimation in routine cranial imaging, we aimed to investigate image quality, posterior fossa artifacts and parenchymal delineation in non-enhanced CT (NECT) with 1-, 4-, 16- and 64-slice scanners using standard scan protocols. We prospectively enrolled 25 consecutive patients undergoing NECT on a 64-slice CT. Three groups with 25 patients having undergone NECT on 1-, 4- and 16-slice CT machines were matched regarding age and sex. Standard routine CT parameters were used on each CT system with helical acquisition in the posterior fossa; the parameters varied regarding collimation and radiation dose. Three blinded readers independently assessed the cases regarding image quality, infra- and supratentorial artifacts and delineation of brain parenchymal structures on a five-point ordinal scale. Reading orders were randomized. A proportional odds model that accounted for the correlated nature of the data was fit using generalized estimating equations. Posterior fossa artifacts were significantly reduced, and the delineation of infratentorial brain structures was significantly improved with the thinner collimation used for the newer CT systems (p<0.001). No significant differences were observed for midbrain structures (p>0.5). The thinner collimation available on modern CT systems leads to reduced posterior fossa artifacts and to a better delineation of brain parenchyma in the posterior fossa.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Aumento da Imagem/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
16.
Radiology ; 241(2): 355-65, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17057064

RESUMO

PURPOSE: To prospectively examine operator dependence of lesion detection, description, and interpretation when experienced breast radiologists perform whole-breast ultrasonography (US). MATERIALS AND METHODS: Institutional review board approval was obtained for the HIPAA-compliant study. Ten women (aged 19-53 years; mean, 37.4 years; 20 breasts) with numerous known breast lesions consented to participate. Eleven breast radiologists, who passed experience and qualification requirements for a screening breast US trial and consented to participate, scanned both breasts in all participants and documented images of each detected lesion and its size, location, features, palpability, and Breast Imaging Reporting and Data System final assessment. Intraclass correlation coefficients (ICCs) were used to measure agreement on lesion size and location, and kappa statistics were calculated for agreement on features and final assessments compared with consensus. RESULTS: Eighty-eight unique lesions were identified by at least two investigators (five to 13 lesions per participant). Mean diameter was 6.7 mm (standard error, 0.4; range, 2-22 mm), and eight lesions (9%) were palpable. Of 968 potential detections (88 lesions, 11 investigators), 536 (55%) detections were made. Individual investigators detected between 43 (49%) and 58 (66%) lesions. Larger lesions were more consistently detected: Detection rates were six of 33 lesions (18%) at 3 mm or smaller; 164 of 374 (43.9%) at 3.1-5 mm; 145 of 275 (52.7%) at 5.1-7 mm; 119 of 176 (67.6%) at 7.1-9 mm; 38 of 44 (86%) at 9.1-11 mm; and 64 of 66 (97%) lesions larger than 11 mm (P < .001). ICCs for clockface, distance from nipple, and individual lesion diameter all exceeded 0.7, indicating high reliability. For shape, margins, and final assessments of solid lesions, kappa values were 0.62, 0.67 (substantial agreement), and 0.52 (moderate agreement), respectively. Of 110 detections of consensus cysts 8 mm and smaller, 15 (14%) detections were considered to be of solid lesions by at least one reader. CONCLUSION: Larger lesions (>11 mm) are most consistently detected, with fewer than half of lesions 5 mm or smaller in mean diameter identified; substantial agreement was found for description of lesion size, location, and key features, and moderate agreement was found for lesion management.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Competência Clínica , Ultrassonografia Mamária , Adulto , Cisto Mamário/diagnóstico por imagem , Doenças Mamárias/patologia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Radiology ; 239(3): 693-702, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16641344

RESUMO

PURPOSE: To prospectively evaluate ultrasonographic (US) lesion detection and characterization in a breast phantom by potential investigators in a screening US protocol, American College of Radiology Imaging Network (ACRIN) 6666. MATERIALS AND METHODS: National Cancer Institute Cancer Experimental Therapeutic Protocol review and ACRIN internal institutional review board approved the protocol; potential investigators were informed of the study purpose prior to participation. Six equivalent anthropomorphic phantoms were prepared with 17 masses (2-10 mm in mean diameter) in different locations at different depths. Sixty-six investigators, experienced in breast US, from 23 institutions scanned a phantom with high-frequency linear-array transducers (12-5 MHz). Lesion location, diameters, echogenicity, shape, and posterior features were recorded. Reader-specific phantom maps were generated and compared with known lesion locations and features. Results from 64 observers could be analyzed and were masked to investigator identity. Agreement on US features was measured with kappa statistics. A generalized linear model generated log relative risks for detection rates as a function of lesion diameter, depth, and features. RESULTS: Of 17 lesions, a median of 14 (82%) were detected (range, 9-16), and 86% of observers detected at least 12 lesions. Of 1088 potential detections, 861 (79.1%) were made. Among 5-10-mm lesions, 499 (97.5%) of 512 detections were made (excluding a 6-mm "skin" lesion seen by only seven observers [11%]). One 4-mm mass was seen by 53 observers (83%). Among 3-mm lesions, 274 (71.4%) of 384 detections were made. One 2-mm lesion was seen by 28 (44%) observers. Relative risk of detection decreased to 0.55 (95% confidence interval: 0.51, 0.59) for each centimeter increase in lesion depth. Agreement was slight for lesion shape (kappa=0.14), substantial for echogenicity (kappa=0.61), and moderate for posterior features (kappa=0.45). Feature description errors were common for 2-4-mm lesions; only 33% of 3-mm anechoic masses were so characterized. Among eight 6-10-mm lesions, investigators erred in feature description of a median of 1 lesion (mean, 1.3; range, 0-4). CONCLUSION: US detection and description of lesions in a breast phantom were highly consistent for lesions 5-10 mm in diameter; those smaller than 5 mm were less reliably identified or characterized by experienced investigators.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia Mamária , Cisto Mamário/diagnóstico por imagem , Doenças Mamárias/patologia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Programas de Rastreamento/estatística & dados numéricos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Mamária/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA