Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cancers (Basel) ; 16(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38539532

RESUMO

BACKGROUND: An incidental axillary dose of adjuvant radiotherapy using tangential beams is usually given after breast-conserving surgery for breast cancer. The goal of this sub-study was to evaluate this incidental dose in the setting of post-mastectomy radiotherapy (PMRT) according to two different radiotherapy techniques. METHODS: Patients participating in a randomized SERC trial who received PMRT in a single center were included. We collected the incidental axillary dose delivered to the Berg level 1 using different dosimetric parameters and compared two techniques using Student's t-test: three-dimensional conformal radiotherapy (3D-CRT) and volumetric arc therapy (VMAT). RESULTS: We analyzed radiotherapy plans from 52 patients who received PMRT from 2012 to 2021. The mean dose delivered to the Berg level 1 was 37.2 Gy. It was significantly higher with VMAT than with 3D-CRT-43.6 Gy (SD = 3.1 Gy) versus 34.8 Gy (SD = 8.6 Gy) p < 0.001. Eighty-four percent of the Berg level 1 was covered by 40 Gy isodose in the VMAT group versus 55.5% in the 3D-CRT group p < 0.001. CONCLUSIONS: On the Berg level 1, PMRT gives a dose at least equivalent to the one given by post-breast-conserving surgery radiotherapy, making it possible to limit completion axillary lymph node dissections in select pN1a patients treated with a mastectomy. Modern radiotherapy techniques like VMAT tend to increase this incidental dose.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA