Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Virol Methods ; 324: 114872, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128833

RESUMO

Point-of-Care for HIV viral RNA quantification seems to be a complementary strategy to the existing conventional systems. This study evaluated the performance of the m-PIMA™ HIV1/2 Viral Load for the quantification of both HIV-1 and HIV-2 RNA viral load. A total of 555 HIV-1 and 90 HIV-2 samples previously tested by Abbott RealTime HIV-1 (Abbott, Chicago, USA) and Generic HIV-2® Charge virale (Biocentric, France) were tested using the m-PIMA™ HIV1/2 Viral Load at the HIV National Reference lab in Senegal. For HIV-1, Pearson correlation and Bland-Altman plots showed a coefficient r = 0.97 and a bias of -0.11 log10 copies/ml (95% confidence interval [CI]: -0.086 to -0.133 log10 copies/ml) for the m-PIMA™ HIV1/2 Viral Load, respectively. Sensitivity and specificity at 3 log10 copies/ml (threshold of virological failure) were 93.6% (95%[CI]: 91.5% to 95.6%) and 99.1% (95%[CI]: 98.3% to 99.9%), respectively. For HIV-2, a correlation of r = 0.95 was also noted with a bias of - 0.229 log10 copies/ml (95%[CI]: -0.161 to -0.297 log10 copies/ml). Sensitivity and specificity at 3 log10 copies/ml were 97.6% (95%[CI]: 94.3% to 100%) and 93.9% (95%[CI]: 88.9% to 98.8%), respectively. These results confirmed that m-PIMA™ HIV1/2 VL could be a good alternative for HIV-1 and HIV-2 viral load testing in decentralized settings in Senegal.


Assuntos
Infecções por HIV , HIV-1 , Humanos , HIV-1/genética , HIV-2/genética , Infecções por HIV/diagnóstico , Carga Viral/métodos , Sensibilidade e Especificidade , África Ocidental , RNA Viral/genética
2.
Pan Afr Med J ; 42: 136, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36060855

RESUMO

Introduction: the introduction of the point-of-care in HIV-1 viral load quantification appears to be a complementary strategy to the existing conventional system of the acceleration plan for the achievement of the three 90s in Senegal. The objective of this study was to evaluate the performance of the Xpert® HIV-1 viral load in the context of circulation of non-B, non-C subtypes. Methods: two hundred samples, were tested on Xpert® HIV-1 Viral Load using 1 ml of plasma in comparison to 600 µl on Abbott Real-time HIV-1 assay. The difference between viral load values was considered significant for Dlog <0.5 log copies/ml. Results: a good correlation (r=0.985) was noted and confirmed using passing-bablok regression (slope 1.048; 95% CI: 1.036 to 1.069) for 188 samples with samples. A mean difference of 0.0075 log10 copies/ml for a 95% confidence interval (CI) of 0.002 log10 copies/ml to 0.013 log10 copies/ml was obtained. Sensitivity and specificity were respectively 93.6% and 93.5% at the threshold of 1.6 log10 copies/ml and 100% and 99% at the threshold of 3.0 log10 copies/ml. Conclusion: these results show that Xpert® HIV-1 Viral Load has excellent performance. In Senegal, and can be used for HIV viral load monitoring.


Assuntos
Infecções por HIV , HIV-1 , Infecções por HIV/diagnóstico , HIV-1/genética , Humanos , RNA Viral , Senegal , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA