Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 387(16): 1477-1487, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36198143

RESUMO

BACKGROUND: In persons with type 1 diabetes and high glycated hemoglobin levels, the benefits of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels are uncertain. METHODS: In a parallel-group, multicenter, randomized, controlled trial involving participants with type 1 diabetes and glycated hemoglobin levels between 7.5% and 11.0%, we investigated the efficacy of intermittently scanned continuous glucose monitoring as compared with participant monitoring of blood glucose levels with fingerstick testing. The primary outcome was the glycated hemoglobin level at 24 weeks, analyzed according to the intention-to-treat principle. Key secondary outcomes included sensor data, participant-reported outcome measures, and safety. RESULTS: A total of 156 participants were randomly assigned, in a 1:1 ratio, to undergo intermittently scanned continuous glucose monitoring (the intervention group, 78 participants) or to monitor their own blood glucose levels with fingerstick testing (the usual-care group, 78 participants). At baseline, the mean (±SD) age of the participants was 44±15 years, and the mean duration of diabetes was 21±13 years; 44% of the participants were women. The mean baseline glycated hemoglobin level was 8.7±0.9% in the intervention group and 8.5±0.8% in the usual-care group; these levels decreased to 7.9±0.8% and 8.3±0.9%, respectively, at 24 weeks (adjusted mean between-group difference, -0.5 percentage points; 95% confidence interval [CI], -0.7 to -0.3; P<0.001). The time per day that the glucose level was in the target range was 9.0 percentage points (95% CI, 4.7 to 13.3) higher or 130 minutes (95% CI, 68 to 192) longer in the intervention group than in the usual-care group, and the time spent in a hypoglycemic state (blood glucose level, <70 mg per deciliter [<3.9 mmol per liter]) was 3.0 percentage points (95% CI, 1.4 to 4.5) lower or 43 minutes (95% CI, 20 to 65) shorter in the intervention group. Two participants in the usual-care group had an episode of severe hypoglycemia, and 1 participant in the intervention group had a skin reaction to the sensor. CONCLUSIONS: Among participants with type 1 diabetes and high glycated hemoglobin levels, the use of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels resulted in significantly lower glycated hemoglobin levels than levels monitored by fingerstick testing. (Funded by Diabetes UK and others; FLASH-UK ClinicalTrials.gov number, NCT03815006.).


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
2.
Diabet Med ; 41(3): e15232, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37750427

RESUMO

OBJECTIVE: We previously showed that intermittently scanned continuous glucose monitoring (isCGM) reduces HbA1c at 24 weeks compared with self-monitoring of blood glucose with finger pricking (SMBG) in adults with type 1 diabetes and high HbA1c levels (58-97 mmol/mol [7.5%-11%]). We aim to assess the economic impact of isCGM compared with SMBG. METHODS: Participant-level baseline and follow-up health status (EQ-5D-5L) and within-trial healthcare resource-use data were collected. Quality-adjusted life-years (QALYs) were derived at 24 weeks, adjusting for baseline EQ-5D-5L. Participant-level costs were generated. Using the IQVIA CORE Diabetes Model, economic analysis was performed from the National Health Service perspective over a lifetime horizon, discounted at 3.5%. RESULTS: Within-trial EQ-5D-5L showed non-significant adjusted incremental QALY gain of 0.006 (95% CI: -0.007 to 0.019) for isCGM compared with SMBG and an adjusted cost increase of £548 (95% CI: 381-714) per participant. The lifetime projected incremental cost (95% CI) of isCGM was £1954 (-5108 to 8904) with an incremental QALY (95% CI) gain of 0.436 (0.195-0.652) resulting in an incremental cost-per-QALY of £4477. In all subgroups, isCGM had an incremental cost-per-QALY better than £20,000 compared with SMBG; for people with baseline HbA1c >75 mmol/mol (9.0%), it was cost-saving. Sensitivity analysis suggested that isCGM remains cost-effective if its effectiveness lasts for at least 7 years. CONCLUSION: While isCGM is associated with increased short-term costs, compared with SMBG, its benefits in lowering HbA1c will lead to sufficient long-term health-gains and cost-savings to justify costs, so long as the effect lasts into the medium term.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Diabetes Mellitus Tipo 1/terapia , Glicemia , Análise Custo-Benefício , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas , Monitoramento Contínuo da Glicose , Medicina Estatal , Inglaterra/epidemiologia , Hipoglicemiantes
3.
Diabet Med ; 41(3): e15249, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37897112

RESUMO

AIMS: The FLASH-UK trial showed lower HbA1c with intermittently scanned continuous glucose monitoring (isCGM), as compared with self monitoring of blood glucose (SMBG), in adults with type 1 diabetes and HbA1c ≥58 mmol/mol (≥7.5%). Here, we present results from the pre-specified subgroup analysis for the 24-week HbA1c (primary outcome) and selected sensor-based secondary outcomes. METHODS: This was a multi-centre, parallel-design, randomised controlled trial. The difference in treatment effect between subgroups (baseline HbA1c [≤75 vs. >75 mmol/mol] [≤9.0 vs >9.0%], treatment modality [pump vs injections], prior participation in structured education, age, educational level, impaired awareness of hypoglycaemia, deprivation index quintile sex, ethnic group and Patient Health Questionnaire-9 [PHQ-9] detected depression category) were evaluated. RESULTS: One hundred fifty-six participants (females 44%, mean [SD] baseline HbA1c 71 [9] mmol/mol 8.6 [0.8%], age 44 [15]) were randomly assigned, in a 1:1 ratio to isCGM (n = 78) or SMBG (n = 78). The mean (SD) baseline HbA1c (%) was 8.7 (0.9) in the isCGM group and 8.5 (0.8) in the SMBG group, lowering to 7.9 (0.8) versus 8.3 (0.9), respectively, at 24 weeks (adjusted mean difference -0.5, 95% confidence interval [CI] -0.7 to -0.3; p < 0.001]. For HbA1c, there was no impact of treatment modality, prior participation in structured education, deprivation index quintile, sex or baseline depression category. The between-group difference in HbA1c was larger for younger people (a reduction of 2.7 [95% CI 0.3-5.0; p = 0.028] mmol/mol for every additional 15 years of age). Those with HbA1c 76-97 mmol/mol (>9.0%-11.0%) had a marginally non-significant higher reduction in HbA1c of 8.4 mmol/mol (3.3-13.5) compared to 3.1 (0.3-6.0) in those with HbA1c 58-75 mmol/mol (p = 0.08). For 'Time in range' (% 3.9-10 mmol/L), the difference was larger for those with at least a bachelor's degree. For 'Time below range' (% <3.9 mmol/L), the difference was larger for those using injections, older people and those with less than bachelor's degree. CONCLUSIONS: Intermittently scanned continuous glucose monitoring is generally effective across a range of baseline characteristics.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Feminino , Humanos , Idoso , Glicemia/análise , Hemoglobinas Glicadas , Automonitorização da Glicemia/métodos , Monitoramento Contínuo da Glicose , Reino Unido , Hipoglicemiantes/uso terapêutico
4.
Clin Endocrinol (Oxf) ; 86(6): 761-771, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28214374

RESUMO

International and national guidelines on the treatment of chronic nonhypovolaemic hypotonic hyponatraemia differ; therefore, we have undertaken this systematic review and meta-analysis to investigate the efficacy and safety of interventions for the treatment of chronic nonhypovolaemic hypotonic hyponatraemia. Following registration of the review protocol with PROSPERO, systematic literature searches were conducted to identify randomized and quasi-randomized controlled trials assessing any degree of fluid restriction or any drug treatment with the aim of increasing serum sodium concentration in patients with chronic nonhypovolaemic hypotonic hyponatraemia. Where appropriate, outcome data were synthesized in a meta-analysis. A total of 45 716 bibliographic records were identified from the searches and 18 trials (assessing conivaptan, lixivaptan, tolvaptan and satavaptan) met the eligibility criteria. Results suggest that all four vasopressin receptor agonists ("vaptans") significantly improve serum sodium concentration. Lixivaptan, satavaptan and tolvaptan were associated with greater rates of response versus placebo. There was no evidence of a difference between each of the vaptans compared with placebo for mortality, discontinuation and rates of hypernatraemia. No RCT evidence of treatments other than the vaptans for hyponatraemia such as oral urea, salt tablets, mannitol, loop diuretics demeclocycline or lithium was identified. Vaptans demonstrated superiority over placebo for outcomes relating to serum sodium correction. Few trials documented the potential benefit of vaptans on change in health-related quality of life as a result of treatment. There was also a lack of high-quality RCT evidence on the comparative efficacy of the vaptans and other treatment strategies for the treatment of chronic nonhypovolaemic hypotonic hyponatraemia.


Assuntos
Antagonistas dos Receptores de Hormônios Antidiuréticos/uso terapêutico , Hiponatremia/terapia , Receptores de Vasopressinas/agonistas , Benzamidas , Benzazepinas , Humanos , Morfolinas , Pressão Osmótica/efeitos dos fármacos , Pirróis , Ensaios Clínicos Controlados Aleatórios como Assunto , Compostos de Espiro , Tolvaptan
5.
BMC Endocr Disord ; 17(1): 69, 2017 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-29110656

RESUMO

BACKGROUND: Indications for use of tolvaptan in SIADH-associated hyponatraemia remain controversial. We audited our local guidelines for Tolvaptan use in this situation to review treatment implications including drug safety, hospital admission episode analysis (episodes of liver toxicity, CNS myelinolysis, sodium-related re-admission rates), morbidity; mortality and underlying aetiologies. METHODS: We report a retrospective case series analysis of on-going treatment outcomes (case-note review) for 31 patients (age 73.3 ± 10.5 years, 55% females) consecutively treated with Tolvaptan as in-patient for confirmed SIADH with persistent S/Na+ < 125 mmol/L despite removal of reversible causes and 24-48 h fluid restriction, and include longer-term outcome data (re-treatment/readmissions/mortality) for up to 4 years of follow-up. A minimum of 6 months follow-up data were reviewed unless the patient died before that period. RESULTS: Short-term outcomes were favourable; 94%-achieved treatment targets after a mean of 3.48 ± 2.46 days. There was statistically significant rise in S/Na+ level after Tolvaptan treatment (before treatment: mean sodium 117.8 ± 3.73, 108-121 mmol/L and after treatment: mean sodium 128.7 ± 3.67, 125-135.2 mmol/L, P < .001). Although the target S/Na+ level was >125 mmol/L in fact one third (35%) of the patients achieved a S/Na+ level of >130 mmol/L by the time of hospital discharge. No patient experienced S/Na+ rise >12 mmol/L/24 h, drug-associated liver injury or CNS-myelinolysis. The average length of hospital stay following start of Tolvaptan treatment was 3.2 days. Relapse of hyponatraemia occurred in 26% of the patients, requiring retreatment with Tolvaptan. In all patients where either relapse of hyponatraemia occurred or readmission was necessary, SIADH was associated with malignancy, which was present overall in 60% of the group studied. CONCLUSIONS: This study confirms the safety and efficacy of Tolvaptan in the treatment of SIADH-related significant, symptomatic hyponatraemia when used under specialist guidance and strict monitoring. A sodium level relapsing below the treatment threshold by 1 week after discontinuation is a good indicator of a patient group with re-treatment/longer-term therapy needs, all of whom had underlying malignancy. The criteria set locally in our trust to initiate Tolvaptan use also identifies a group where further investigation for underlying malignancy should be considered.


Assuntos
Antagonistas dos Receptores de Hormônios Antidiuréticos/uso terapêutico , Benzazepinas/uso terapêutico , Hiponatremia/tratamento farmacológico , Síndrome de Secreção Inadequada de HAD/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Síndrome de Secreção Inadequada de HAD/etiologia , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Estudos Retrospectivos , Tolvaptan , Resultado do Tratamento
6.
Eur J Clin Invest ; 45(8): 888-94, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25995119

RESUMO

BACKGROUND: Hyponatraemia is a very common medical condition that is associated with multiple poor clinical outcomes and is often managed suboptimally because of inadequate assessment and investigation. Previously published guidelines for its management are often complex and impractical to follow in a hospital environment, where patients may present to divergent specialists, as well as to generalists. DESIGN: A group of senior, experienced UK clinicians, met to develop a practical algorithm for the assessment and management of hyponatraemia in a hospital setting. The latest evidence was discussed and reviewed in the light of current clinical practicalities to ensure an up-to-date perspective. An algorithm was largely developed following consensus opinion, followed up with subsequent additions and amendments that were agreed by all authors during several rounds of review. RESULTS: We present a practical algorithm which includes a breakdown of the best methods to evaluate volume status, simple assessments for the diagnosis of the various causes and a straightforward approach to treatment to minimise complexity and maximise patient safety. CONCLUSION: The algorithm we have developed reflects the best available evidence and extensive clinical experience and provides practical, useable guidance to improve patient care.


Assuntos
Algoritmos , Antibacterianos/uso terapêutico , Antagonistas dos Receptores de Hormônios Antidiuréticos/uso terapêutico , Benzazepinas/uso terapêutico , Demeclociclina/uso terapêutico , Hidratação , Hiponatremia/terapia , Síndrome de Secreção Inadequada de HAD/terapia , Hospitalização , Humanos , Hiponatremia/diagnóstico , Síndrome de Secreção Inadequada de HAD/diagnóstico , Guias de Prática Clínica como Assunto , Tolvaptan , Desequilíbrio Hidroeletrolítico/diagnóstico , Desequilíbrio Hidroeletrolítico/terapia
8.
Adv Ther ; 40(5): 2015-2037, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36928495

RESUMO

INTRODUCTION: The objective of this systematic literature review was to evaluate the available literature concerning the clinical, economic, and patient-reported benefits of insulin pen platforms, including connected insulin pens/caps/sleeves and insulin platforms, as well as mobile apps capable of receiving near real-time insulin dosing information. METHODS: Medline and Embase databases and the Cochrane Library were searched for published literature between January 2015 and May 2021, and manual searches for conference abstracts from 2018 to May 2021 were performed. These searches were supplemented by internet searches for relevant literature and clinical trials. Study selection involved the population, intervention, comparator, outcomes, time frame, and study design outline. Included studies investigated connected insulin systems or connected caps/sleeves enabling pens to be connected, or apps able to connect to these systems, in individuals of all ages with type 1 or type 2 diabetes mellitus. RESULTS: Searches identified a total of 26 publications (mostly observational studies and conference abstracts) for inclusion, representing ten unique, predominantly small studies. Evidence in this field is still in its early stages, and only two randomized controlled trials met our inclusion criteria. Available results showed that connected insulin pens and their systems potentially helped reduce suboptimal insulin use and may therefore improve glycemic control. Satisfaction of people with diabetes with the technologies used was high, and economic benefits were noted. Features of effective connected insulin pen devices include simplicity of use and data upload/sharing, useful "point-of-care" alerts, and simple and understandable data presentation to facilitate more effective consultations. CONCLUSIONS: Connected insulin pen systems could be increasingly considered as part of routine clinical care for insulin-treated persons with diabetes who must manage the complexity of their daily insulin routine. Future research focusing on the way data obtained from these devices can be most effectively used alongside other information is urgently needed.


Digital health tools, like text message reminders and mobile apps, are being used more often to help people with diabetes improve their health in a way that works for them. For people who take insulin to treat their diabetes, what has been missing is a way to track insulin doses alongside other diabetes information in an app. Connected insulin pens, also called smart pens, are able to do this. In this article we have looked at the evidence available on the benefits of connected insulin pens. We found that while information on connected insulin pens is limited at the moment, what there is shows that using a connected insulin pen can help people remember to take their insulin and give themselves the right dose and that those who have used a connected insulin pen or related technology are happy with it. Useful features of connected insulin pens include being easy to use, having an alert function, and being able to share the insulin information with the user's doctor. Connected insulin pens may also reduce diabetes-related costs. Connected insulin pens are likely to become more common for people with diabetes who take insulin, but there is a need for more research on how best to use them to improve the treatment of people with diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglicemiantes , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Ensaios Clínicos Controlados Aleatórios como Assunto , Insulina/administração & dosagem , Insulina/economia , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/economia , Aplicativos Móveis , Sistemas Automatizados de Assistência Junto ao Leito , Injeções Subcutâneas , Análise Custo-Benefício
9.
J Diabetes Sci Technol ; 17(4): 971-975, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37148160

RESUMO

BACKGROUND: Continuous glucose monitoring (CGM) is revolutionizing diabetes care by giving both patients and the healthcare professionals unprecedented insights into glucose variability and patterns. It is established in National Institute for Health and Care Excellence (NICE) guidance as a standard of care for type 1 diabetes and diabetes in pregnancy under certain conditions. Diabetes mellitus (DM) is recognized as an important risk factor for chronic kidney disease (CKD). Around a third of patients receiving in-center haemodialysis as renal replacement therapy (RRT) have diabetes, either as a direct cause of renal failure or as an additional co-morbidity. Evidence of poor compliance with the current standard of care (self-monitoring of blood glucose [SMBG]) and overall greater morbidity and mortality, suggests this patient population as an ideal target group for CGM. However, there exists no strong published evidence showing the validity of CGM devices in insulin-treated diabetes patients requiring haemodialysis. METHODS: We applied a Freestyle Libre Pro sensor to 69 insulin-treated diabetes haemodialysis (HD) patients on a dialysis day. Interstitial glucose levels were obtained, and time matched within 7 minutes to capillary blood glucose testing and any plasma blood glucose levels sent. Data cleansing techniques were applied to account for rapidly correcting hypoglycaemia and poor SMBG technique. RESULTS: Clarke-error grid analysis showed 97.9% of glucose values in an acceptable range of agreement (97.3% on dialysis days and 99.1% on non-dialysis days). CONCLUSIONS: We conclude that the Freestyle Libre sensor is accurate in measuring glucose levels when compared to glucose as measured by capillary SMBG testing and laboratory obtained serum glucose in patients on HD.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Gravidez , Feminino , Humanos , Insulina/uso terapêutico , Glicemia/análise , Automonitorização da Glicemia , Insulina Regular Humana , Diálise Renal
10.
Diabetes Care ; 46(10): 1831-1838, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566697

RESUMO

OBJECTIVE: We explored longitudinal changes associated with switching to hybrid closed-loop (HCL) insulin delivery systems in adults with type 1 diabetes and elevated HbA1c levels despite the use of intermittently scanned continuous glucose monitoring (isCGM) and insulin pump therapy. RESEARCH DESIGN AND METHODS: We undertook a pragmatic, preplanned observational study of participants included in the National Health Service England closed-loop pilot. Adults using isCGM and insulin pump across 31 diabetes centers in England with an HbA1c ≥8.5% who were willing to commence HCL therapy were included. Outcomes included change in HbA1c, sensor glucometrics, diabetes distress score, Gold score (hypoglycemia awareness), acute event rates, and user opinion of HCL. RESULTS: In total, 570 HCL users were included (median age 40 [IQR 29-50] years, 67% female, and 85% White). Mean baseline HbA1c was 9.4 ± 0.9% (78.9 ± 9.1 mmol/mol) with a median follow-up of 5.1 (IQR 3.9-6.6) months. Of 520 users continuing HCL at follow-up, mean adjusted HbA1c reduced by 1.7% (95% CI 1.5, 1.8; P < 0.0001) (18.1 mmol/mol [95% CI 16.6, 19.6]; P < 0.0001). Time in range (70-180 mg/dL) increased from 34.2 to 61.9% (P < 0.001). Individuals with HbA1c of ≤58 mmol/mol rose from 0 to 39.4% (P < 0.0001), and those achieving ≥70% glucose time in range and <4% time below range increased from 0.8 to 28.2% (P < 0.0001). Almost all participants rated HCL therapy as having a positive impact on quality of life (94.7% [540 of 570]). CONCLUSIONS: Use of HCL is associated with improvements in HbA1c, time in range, hypoglycemia, and diabetes-related distress and quality of life in people with type 1 diabetes in the real world.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Feminino , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Glicemia , Automonitorização da Glicemia , Qualidade de Vida , Medicina Estatal , Insulina , Sistemas de Infusão de Insulina
11.
BMC Fam Pract ; 13: 102, 2012 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-23062116

RESUMO

BACKGROUND: People with T1DM and insulin-treated T2DM often do not follow and/or adjust their insulin regimens as needed. Key contributors to treatment non-adherence are fear of hypoglycaemia, difficulty and lack of self-efficacy associated with insulin dose determination. Because manual calculation of insulin boluses is both complex and time consuming, people may rely on empirical estimates, which can result in persistent hypoglycaemia and/or hyperglycaemia. Use of automated bolus advisors (BA) has been shown to help insulin pump users to more accurately meet prandial insulin dosage requirements, improve postprandial glycaemic excursions, and achieve optimal glycaemic control with an increased time within optimal range. Use of a BA containing an early algorithm based on sliding scales for insulin dosing has also been shown to improve HbA1c levels in people treated with multiple daily insulin injections (MDI). We designed a study to determine if use of an automated BA can improve clinical and psychosocial outcomes in people treated with MDI. METHODS/DESIGN: The Automated Bolus Advisor Control and Usability Study (ABACUS) is a 6-month, prospective, randomised, multi-centre, multi-national trial to determine if automated BA use improves glycaemic control as measured by a change in HbA1c in people using MDI with elevated HbA1c levels (#62;7.5%). A total of 226 T1DM and T2DM participants will be recruited. Anticipated attrition of 20% will yield a sample size of 90 participants, which will provide #62;80% power to detect a mean difference of 0.5%, with SD of 0.9%, using a one-sided 5% t-test, with 5% significance level. Other measures of glycaemic control, self-care behaviours and psychosocial issues will also be assessed. DISCUSSION: It is critical that healthcare providers utilise available technologies that both facilitate effective glucose management and address concerns about safety and lifestyle. Automated BAs may help people using MDI to manage their diabetes more effectively and minimise the risk of long-term diabetes related complications. Findings from a recent study suggest that BA use positively addresses both safety and lifestyle concerns; however, randomised trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes. Our study is designed to make these assessments. TRIAL REGISTRATION: NCT01460446.


Assuntos
Algoritmos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Cálculos da Dosagem de Medicamento , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Adesão à Medicação , Satisfação do Paciente , Estudos Prospectivos , Autocuidado , Resultado do Tratamento
12.
BMJ Open ; 11(7): e050713, 2021 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-34261691

RESUMO

INTRODUCTION: Optimising glycaemic control in type 1 diabetes (T1D) remains challenging. Flash glucose monitoring with FreeStyle Libre 2 (FSL2) is a novel alternative to the current standard of care self-monitoring of blood glucose (SMBG). No randomised controlled trials to date have explored the potential benefits of FSL2 in T1D. We aim to assess the impact of FSL2 in people with suboptimal glycaemic control T1D in comparison with SMBG. METHODS: This open-label, multicentre, randomised (via stochastic minimisation), parallel design study conducted at eight UK secondary and primary care centres will aim to recruit 180 people age ≥16 years with T1D for >1 year and glycated haemoglobin (HbA1c) 7.5%-11%. Eligible participants will be randomised to 24 weeks of FSL2 (intervention) or SMBG (control) periods, after 2-week of blinded sensor wear. Participants will be assessed virtually or in-person owing to the COVID-19 pandemic. HbA1c will be measured at baseline, 12 and 24 weeks (primary outcome). Participants will be contacted at 4 and 12 weeks for glucose optimisation. Control participants will wear a blinded sensor during the last 2 weeks. Psychosocial outcomes will be measured at baseline and 24 weeks. Secondary outcomes include sensor-based metrics, insulin doses, adverse events and self-report psychosocial measures. Utility, acceptability, expectations and experience of using FSL2 will be explored. Data on health service resource utilisation will be collected. ANALYSIS: Efficacy analyses will follow intention-to-treat principle. Outcomes will be analysed using analysis of covariance, adjusted for the baseline value of the corresponding outcome, minimisation factors and other known prognostic factors. Both within-trial and life-time economic evaluations, informed by modelling from the perspective of the National Health Service setting, will be performed. ETHICS: The study was approved by Greater Manchester West Research Ethics Committee (reference 19/NW/0081). Informed consent will be sought from all participants. TRIAL REGISTRATION NUMBER: NCT03815006. PROTOCOL VERSION: 4.0 dated 29 June 2020.


Assuntos
COVID-19 , Diabetes Mellitus Tipo 1 , Adolescente , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes , Estudos Multicêntricos como Assunto , Pandemias , Ensaios Clínicos Controlados Aleatórios como Assunto , SARS-CoV-2 , Medicina Estatal , Reino Unido
13.
J Diabetes Sci Technol ; 10(6): 1294-1302, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27154973

RESUMO

BACKGROUND: In 2014, an innovative blinded continuous glucose monitoring system was introduced with automated ambulatory glucose profile (AGP) reporting. The clinical use and interpretation of this new technology has not previously been described. Therefore we wanted to understand its use in characterizing key factors related to glycemic control: glucose exposure, variability, and stability, and risk of hypoglycemia in clinical practice. METHODS: Clinicians representing affiliated diabetes centers throughout South Africa were trained and subsequently were given flash glucose monitoring readers and 2-week glucose sensors to use at their discretion. After patient use, sensor data were collected and uploaded for AGP reporting. RESULTS: Complete data (sensor AGP with corresponding clinical information) were obtained for 50 patients with type 1 (70%) and type 2 diabetes (30%), irrespective of therapy. Aggregated analysis of AGP data comparing patients with type 1 versus type 2 diabetes, revealed that despite similar HbA1c values between both groups (8.4 ± 2 vs 8.6 ± 1.7%, respectively), those with type 2 diabetes had lower mean glucose levels (9.2 ± 3 vs 10.3 mmol/l [166 ± 54 vs 185 mg/dl]) and lower indices of glucose variability (3.0 ± 1.5 vs 5.0 ± 1.9 mmol/l [54 ± 27 vs 90 ± 34.2 mg/dl]). This highlights key areas for future focus. CONCLUSIONS: Using AGP, the characteristics of glucose exposure, variability, stability, and hypoglycemia risk and occurrence were obtained within a short time and with minimal provider and patient input. In a survey at the time of the follow-up visit, clinicians indicated that aggregated AGP data analysis provided important new clinical information and insights.


Assuntos
Glicemia/análise , Diabetes Mellitus/sangue , Adulto , Idoso , Área Sob a Curva , Feminino , Hemoglobinas Glicadas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Curva ROC , Estudos Retrospectivos , África do Sul
14.
J Clin Transl Endocrinol ; 1(4): 161-166, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29159096

RESUMO

AIMS: We investigated the impact of using an integrated, strip-free system compared to the use of single-strip systems on testing frequency and glycemic control in individuals with insulin-treated diabetes. METHODS: This multinational, comparative, cluster-randomized, observational study included 311 patients with type 1 and insulin-treated type 2 diabetes who were performing SMBG at suboptimal frequencies. Sites were cluster-randomized to "integrated strip-free" system (EXP group) or any "single-strip" system (CNL group). Testing frequency and HbA1c were measured at baseline, 12 weeks and 24 weeks. RESULTS: At week 24, the EXP group showed an increase in SMBG frequency from baseline of 4.17 tests/week (95% CI 2.76, 5.58) compared with an increase of 0.53 tests/week (95% CI -0.73, 1.79) among CNL patients, resulting in a between-group difference of 3.63 tests/week (p < 0.0002). Mixed-effects models for repeated measurements (MMRM) controlling for baseline frequency of testing, country and clinical site confirmed a higher SMBG testing frequency in the EXP group compared to the CNL group, with a between-group difference of 2.70 tests/week (p < 0.01). Univariate analysis showed greater HbA1c reductions in the EXP group than CNL group: -0.44% (95% CI -0.59, -0.29) vs. -0.13% (95% CI -0.27, 0.01), respectively, p < 0.0002. MMRM analyses confirmed these HbA1c reductions. A greater percentage of EXP than CNL patients achieved HbA1c reductions of ≥0.5%: 45.1% vs. 29.1%, respectively, p < 0.01. CONCLUSIONS: The use of an integrated, strip-free SMBG system improved testing adherence and was associated with improvements in glycemic control.

15.
Diabetes Technol Ther ; 16(5): 310-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24716820

RESUMO

BACKGROUND: We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with multiple daily insulin injection (MDI) therapy. SUBJECTS AND METHODS: The Automated Bolus Advisor Control and Usability Study (ABACUS) trial, a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 type 1 and type 2 diabetes patients, demonstrated that use of an automated insulin bolus advisor helps improve glycemic control in suboptimally controlled, MDI-treated patients. Patient data were assessed to determine when and how often changes in insulin parameter settings occurred during the study. Patient meters were downloaded to determine blood glucose monitoring frequency. RESULTS: One hundred ninety-three patients completed the study: 93 control arm (CNL) and 100 intervention (experimental) arm (EXP). Significantly more EXP (47.5%) than CNL (30.7%) patients received one or more changes in their insulin sensitivity factor (ISF) settings during the study (P=0.0191). Changes in ISF settings occurred earlier and more frequently in EXP than CNL patients throughout the study. A similar trend was seen in changes in insulin-to-carbohydrate ratios. There were no differences in daily self-monitoring of blood glucose frequency [mean (SD)] between CNL and EXP patients: 4.7 (1.5) versus 4.6 (1.3) (P=0.4085). CONCLUSIONS: Use of an automated bolus advisor was associated with earlier, more frequent changes in key insulin parameters, which may have contributed to subsequent improvements in glycemic control but without increased glucose test strip utilization.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Adolescente , Adulto , Automonitorização da Glicemia/instrumentação , Distribuição de Qui-Quadrado , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Esquema de Medicação , Feminino , Hemoglobinas Glicadas/análise , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
16.
Diabetes Care ; 36(11): 3613-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23900590

RESUMO

OBJECTIVE: Use of automated bolus advisors is associated with improved glycemic control in patients treated with insulin pump therapy. We conducted a study to assess the impact of using an insulin bolus advisor embedded in a blood glucose (BG) meter on glycemic control and treatment satisfaction in patients treated with multiple daily insulin injection (MDI) therapy. The study goal was to achieve >0.5% A1C reduction in most patients. RESEARCH DESIGN AND METHODS: This was a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 MDI-treated patients with poorly controlled diabetes (202 with type 1 diabetes, 16 with type 2 diabetes) who were 18 years of age or older. Participants had mean baseline A1C of 8.9% (SD, 1.2 [74 mmol/mol]), mean age of 42.4 years (SD, 14.0), mean BMI of 26.5 kg/m(2) (SD, 4.2), and mean diabetes duration of 17.7 years (SD, 11.1). Control group (CNL) patients used a standard BG meter and manual bolus calculation; intervention group (EXP) patients used the Accu-Chek Aviva Expert meter with an integrated bolus advisor to calculate insulin dosages. Glucose data were downloaded and used for therapy parameter adjustments in both groups. RESULTS: A total of 193 patients (CNL, n = 93; EXP, n = 100) completed the study. Significantly more EXP than CNL patients achieved >0.5% A1C reduction (56.0% vs. 34.4%; P < 0.01). Improvement in treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire scale) was significantly greater in EXP patients (11.4 [SD, 6.0] vs. 9.0 [SD, 6.3]; P < 0.01). Percentage of BG values <50 mg/dL was <2% in both groups during the study. CONCLUSIONS: Use of an automated bolus advisor resulted in improved glycemic control and treatment satisfaction without increasing severe hypoglycemia.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Adolescente , Adulto , Glicemia/análise , Automonitorização da Glicemia/métodos , Feminino , Humanos , Hipoglicemia/tratamento farmacológico , Sistemas de Infusão de Insulina , Masculino , Estudos Prospectivos , Adulto Jovem
17.
Diabetes ; 56(11): 2766-73, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17660265

RESUMO

OBJECTIVE: Loss of ability to recognize hypoglycemia (hypoglycemia unawareness) increases risk of severe hypoglycemia threefold in insulin-treated diabetes. We set out to investigate the cerebral correlates of unawareness in type 1 patients. RESEARCH DESIGN AND METHODS: Regional changes in brain glucose kinetics were measured using [(18)F]-fluorodeoxyglucose (FDG) positron emission tomography (PET), in 13 men with type 1 diabetes--6 with hypoglycemia awareness and 7 with hypoglycemia unawareness--at euglycemia (5 mmol/l) and hypoglycemia (2.6 mmol/l), in random order. RESULTS: Epinephrine responses to hypoglycemia were reduced in hypoglycemia unawareness (P < 0.0003), as were symptoms. Statistical parametric mapping (SPM) of FDG uptake using SPM2 at a statistical threshold of P < 0.005 showed increased FDG uptake in left amygdala in hypoglycemia awareness, but not in hypoglycemia unawareness (region of interest analysis -0.40 +/- 1.03 vs. 3.66 +/- 0.42, respectively; P = 0.007), and robust increase in bilateral ventral striatum during hypoglycemia (region of interest analysis hypoglycemia unawareness 3.52 +/- 1.02 vs. awareness 6.1 +/- 0.53; P = 0.054). Further analysis at the statistical threshold of P < 0.01 showed bilateral attenuated activation of brain stem regions and less deactivation in lateral orbitofrontal cortex in hypoglycemia unawareness. CONCLUSIONS: Ventral striatal, amygdala, brain stem, and orbitofrontal responses to hypoglycemia indicate engagement of appetitive motivational networks, associated with integrated behavioral responses to hypoglycemia. Reduced responses in these networks in hypoglycemia unawareness, particularly failure of amygdala and orbifrontal cortex responses, suggest habituation of higher behavioral responses to hypoglycemia as a basis for unawareness. New approaches may be needed to restore awareness effectively in practice.


Assuntos
Tonsila do Cerebelo/fisiopatologia , Conscientização , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/fisiopatologia , Lobo Frontal/fisiopatologia , Hipoglicemia/sangue , Tonsila do Cerebelo/diagnóstico por imagem , Glicemia/análise , Automonitorização da Glicemia , Encéfalo/metabolismo , Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/fisiopatologia , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/fisiopatologia , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Diabetes Mellitus Tipo 1/psicologia , Fluordesoxiglucose F18/farmacocinética , Lobo Frontal/diagnóstico por imagem , Glucose/metabolismo , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Radiografia , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA