Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 91(3): 435-443, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28707379

RESUMO

BACKGROUND: Pre-clinical results of a novel open-cell, thin strut, durable polymer, laser cut cobalt chromium sirolimus-eluting stent (Angiolite) were promising. Using quantitative optical coherence tomographic (OCT) analyses, we explored the healing characteristics of the Angiolite DES system at 3- and 6-months post implantation. METHODS: A total of 103 patients with de novo coronary lesions underwent percutaneous coronary intervention with the Angiolite DES and were randomized 1:3 into two cohorts for angiographic and OCT follow-up, with 28 and 70 patients returning for 3- or 6-month post-PCI surveillance, respectively. The primary endpoints were the 6-month rates of OCT-derived neointimal proliferation, strut coverage and incomplete strut apposition (ISA), whilst the secondary endpoints were 3-month OCT-derived measures of strut coverage and ISA, as well as 6-month quantitative coronary angiographic-derived measures [late lumen loss (LLL), binary restenosis]. RESULTS: The Angiolite stent was successfully implanted in all patients, without periprocedural complications. At 3- and 6-months follow-up, OCT strut coverage was evident in 86.3% and 83.3% of struts, mean neointimal thickness was 73.7 ± 46.5 µm and 73.9 ± 54.3 µm, mean neo-intimal area obstruction of 5.8% ±10.3% and 4.4% ± 11.3%, and ISA rates were 1.3% ± 7.3% and 1.1% ± 6.2%, respectively. In-stent LLL at 6 months was 0.07 ± 0.37 mm, with a binary in-stent angiographic restenosis rate of 0% without any stent thrombosis, myocardial infarction or cardiovascular death, with 1 patient undergoing ischemia-driven target-lesion revascularization. CONCLUSIONS: At 6 months, the Angiolite DES was safe with high rates of strut coverage, modest degrees of neointimal hyperplasia and very low rates of strut malapposition. These data coupled with the absence of in-stent binary restenosis and a very low 6-month in-stent LLL point towards an efficacious DES. Future studies are required to evaluate its efficacy in broader lesion subsets with longer follow-up.


Assuntos
Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
2.
Circ Cardiovasc Interv ; 15(11): 861-871, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36111801

RESUMO

BACKGROUND: There is little information available on agreement between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) in left main coronary artery (LMCA) intermediate stenosis. Besides, several meta-analyses support the use of FFR to guide LMCA revascularization, but limited information is available on iFR in this setting. Our aims were to establish the concordance between FFR and iFR in intermediate LMCA lesions, to evaluate with intravascular ultrasound (IVUS) in cases of FFR/iFR discordance, and to prospectively validate the safety of deferring revascularization based on a hybrid decision-making strategy combining iFR and IVUS. METHODS: Prospective, observational, multicenter registry with 300 consecutive patients with intermediate LMCA stenosis who underwent FFR and iFR and, in case of discordance, IVUS and minimal lumen area measurements. Primary clinical end point was a composite of cardiovascular death, LMCA lesion-related nonfatal myocardial infarction, or unplanned LMCA revascularization. RESULTS: FFR and iFR had an agreement of 80% (both positive in 67 and both negative in 167 patients); in case of disagreement (31 FFR+/iFR- and 29 FFR-/iFR+) minimal lumen area was ≥6 mm2 in 8.7% of patients with FFR+ and 14.6% with iFR+. Among the 300 patients, 105 (35%) underwent revascularization and 181 (60%) were deferred according to iFR and IVUS. At a median follow-up of 20 months, major adverse cardiac events incidence was 8.3% in the defer group and 13.3% in the revascularization group (hazard ratio, 0.71 [95% CI 0.30-1.72]; P=0.45). CONCLUSIONS: In patients with intermediate LMCA stenosis, a physiology-guided treatment decision is feasible either with FFR or iFR with moderate concordance between both indices. In case of disagreement, the use of IVUS may be useful to indicate revascularization. Deferral of revascularization based on iFR appears to be safe in terms of major adverse cardiac events. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03767621.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Prognóstico , Angiografia Coronária , Estudos Prospectivos , Constrição Patológica , Resultado do Tratamento , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Índice de Gravidade de Doença , Ultrassonografia de Intervenção , Valor Preditivo dos Testes , Cateterismo Cardíaco
3.
Animals (Basel) ; 10(9)2020 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-32824935

RESUMO

New-generation catheters-based renal denervation (RDN) is under investigation for the treatment of uncontrolled hypertension (HTN). We assessed the feasibility of a large animal model of HTN to accommodate the human RDN devices. Ten minipigs were instrumented to measure blood pressure (BP) in an awake-state. HTN was induced with subcutaneous 11-deoxycorticosterone (DOCA, 100 mg/kg) implants. Five months after, the surviving animals underwent RDN with the Symplicity® system. Norepinephrine (NE) renal gradients were determined before and 1 month after RDN. Renal arteries were processed for histological (hematoxylin-eosin, Movat pentachrome) and immunohistochemical (S100, tyrosine-hydroxylase) analyses. BP significantly rose after DOCA implants. Six animals died prematurely, mainly from infectious causes. The surviving animals showed stable BP levels after 5 months. One month after RDN, nerve damage was showed in three animals, with impedance drop >10%, NE gradient drop and reduction in BP. The fourth animal showed no nerve damage, impedance drop <10%, NE gradient increase and no change in BP. In conclusion, the minipig model of DOCA-induced HTN is feasible, showing durable effects. High mortality should be addressed in next iterations of this model. RDN may partially offset the DOCA-induced HTN. Impedance drop and NE renal gradient could be markers of RDN success.

4.
J Interv Cardiol ; 22(3): 222-7, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19490356

RESUMO

OBJECTIVE: To evaluate the degree of endothelialization of the nonapposed struts located at the ostia of side branches. BACKGROUND: Endothelialization of coronary stents has got considerable relevance because of the phenomenon of late thrombosis. Bifurcation location and incomplete stent apposition have been linked to this complication. METHODS: Domestic pigs (n = 11; weight: 25 +/- 3 kg) were anesthetized and had one stent per coronary artery implanted: one stainless steel (Tecnic), one cobalt-chromium (Chrono), and one tacrolimus-eluting stent (Janus), all of them being Carbofilm-coated (Sorin). One, three, or seven days postprocedure, the pigs were sacrificed, the hearts explanted, and longitudinal sections examined by surface electron microscopy to quantify the percentage of the strut endothelialized over the branches and in the total surface. RESULTS: Forty-four side branches (25 stents) that had stent struts over their origin were evaluated. Different patterns of endothelialization were observed, from the total absence to the complete endothelialization. There were no significant differences in relation to type of stent or to the artery treated. The predictors of higher percentage of endothelialization were the ratio of metal to branch diameter (P = 0.04) and better endothelialization in the rest of the stent (P = 0.0002), only this parameter maintaining significant correlation (P = 0.03) in multivariate analysis. CONCLUSIONS: Carbofilm-coated stent struts located over the origin of side branches follow the pattern of endothelialization for the rest of the stent, even in the case of tacrolimus-eluting stent.


Assuntos
Reestenose Coronária/prevenção & controle , Vasos Coronários/patologia , Stents Farmacológicos , Endotélio/patologia , Imunossupressores/uso terapêutico , Tacrolimo/uso terapêutico , Trombose/prevenção & controle , Análise de Variância , Animais , Doença da Artéria Coronariana/prevenção & controle , Humanos , Fatores de Risco , Estatística como Assunto , Suínos
6.
Rev Esp Cardiol (Engl Ed) ; 70(12): 1059-1066, 2017 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28647315

RESUMO

INTRODUCTION AND OBJECTIVES: New drug-eluting stents (DES) designed to overcome the limitations of existing devices should initially be tested in preclinical studies. Our objective was to analyze the safety and efficacy of new biodegradable polymer-based DES compared with bare-metal stents (BMS) and commercially available DES in a model of normal porcine coronary arteries. METHODS: We randomly implanted 101 stents (BMS and biodegradable polymer-based sirolimus-eluting stents: 3 test stent iterations [BD1, BD2, and BD3], Orsiro, Biomime and Biomatrix) in the coronary arteries of 34 domestic pigs. Angiographic and histomorphometric studies were conducted 1 month (n = 83) and 3 months (n = 18) later. RESULTS: The stents were implanted at a stent/artery ratio of 1.31 ± 0.21, with no significant differences between groups. At 1 month, the new test stents (BD1, BD2 and BD3) showed less late loss and angiographic restenosis, as well as lower histologic restenosis and neointimal area (P < .0005), than the BMS. There were no differences in endothelialization, vascular injury, or inflammation between the new test stents and BMS, although the new stents showed higher fibrin deposition (P = .0006). At 3 months, all these differences disappeared, except for a lower neointimal area with the new BD1 stent (P = .027). No differences at any time point were observed between the new test stents and commercially available controls. CONCLUSIONS: In this preclinical model, the new biodegradable polymer-based DES studied showed less restenosis than BMS and no significant differences in safety or efficacy vs commercially available DES.


Assuntos
Implantes Absorvíveis , Reestenose Coronária/epidemiologia , Vasos Coronários/cirurgia , Stents Farmacológicos , Neointima/epidemiologia , Polímeros , Animais , Antibióticos Antineoplásicos/administração & dosagem , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Vasos Coronários/diagnóstico por imagem , Metais , Neointima/patologia , Desenho de Prótese , Distribuição Aleatória , Sirolimo/administração & dosagem , Stents , Sus scrofa , Suínos , Resultado do Tratamento
7.
Geriatr Gerontol Int ; 16(12): 1246-1253, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26735289

RESUMO

AIM: As a result of a higher prevalence of comorbidities, elderly adults are often underrepresented in clinical trials, and more often experience complications during percutaneous coronary intervention. Our aim was to evaluate clinical outcomes of patients older than 80 years, compared with their younger counterparts, when bioresorbable polymer biolimus A9 drug-eluting stent is used for their treatment. METHODS: The prospective, observational e-Nobori registry was created to validate the safety and efficacy of bioresorbable polymer drug-eluting stent in unselected patients. The primary end-point of the study was freedom from target lesion failure defined as a composite of cardiac death, target vessel-related myocardial infarction and clinically-driven target lesion revascularization at 1 year. RESULTS: There were 781 (7.8%) octogenarians, they were less frequently male (62% vs 77%; P < 0.0001) and more often presented as acute coronary syndrome (44% vs 39%; P = 0.0182). The index percutaneous coronary intervention success was lower in the elderly patients (98% vs 99%; P = 0.0398). One-year follow up was completed for 97% of the elderly patients and 99% of the younger patients. The difference in target lesion failure (3.33% vs 2.83%; log-rank P = 0.0114) was mainly driven by increased mortality in octogenarians (3.73% vs 1.47%; P < 0.0001). Elderly patients had more bleeding and vascular complications (2.67% vs 1.05%; P = 0.0001). CONCLUSIONS: Despite advanced age, multiple comorbidities and complexity of treated lesions, clinical outcomes are favorable in octogenarians treated by bioresorbable polymer biolimus A9 drug-eluting stent. Geriatr Gerontol Int 2016; 16: 1246-1253.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Infarto do Miocárdio/terapia , Idoso de 80 Anos ou mais , Humanos , Masculino , Intervenção Coronária Percutânea , Polímeros , Estudos Prospectivos , Resultado do Tratamento
8.
Rev Esp Cardiol (Engl Ed) ; 68(12): 1118-24, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26206247

RESUMO

INTRODUCTION AND OBJECTIVES: Initial preclinical studies are required during the process of improving polymers, platforms, and drug-eluting systems for new coronary stent designs. Our objective was to analyze the efficacy and safety of new drug-eluting stent models compared with a conventional stent and commercialized drug-eluting stents in an experimental model with healthy porcine coronary arteries. METHODS: Sixty stents (conventional stent, new sirolimus-eluting stents: drug-eluting stents 1, 2 and 3; Cypher(®) and Xience(®)) were randomly placed in the coronary arteries of 20 Large White domestic pigs. Angiographic and histomorphometric studies were done 28 days later. RESULTS: The stents were implanted at a stent/artery ratio of 1.34±0.15, with no significant differences between groups. The new stents showed less late loss and angiographic restenosis than conventional stents (P=.006 and P<.001, respectively). Histologically, restenosis and neointimal area were lower with all the new platforms than with the conventional stents (P<.001 for each variable), and no differences were found vs the drug-eluting stents on the market. Safety data showed that endothelialization was lower with drug-eluting stents than with conventional stents, except for drug-eluting stent 3 (P=.084). Likewise, inflammation was lower with drug-eluting stent 3 than with other stents. CONCLUSIONS: The new drug-eluting stent platforms studied are associated with less restenosis than conventional stents and showed no significant differences in safety or efficacy vs commercialized drug-eluting stents.


Assuntos
Stents Farmacológicos , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Animais , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Modelos Animais de Doenças , Imunossupressores/farmacologia , Desenho de Prótese , Distribuição Aleatória , Sirolimo/farmacologia , Sus scrofa , Suínos
9.
Rev Esp Cardiol (Engl Ed) ; 67(6): 456-62, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24863594

RESUMO

INTRODUCTION AND OBJECTIVES: Paclitaxel-eluting balloons have shown high antiproliferative efficacy in the treatment and prevention of restenosis. Nevertheless, not all available devices are equally effective, which makes it interesting to compare results in a preclinical model. Our objective was to assess the preclinical efficacy and safety of different devices. METHODS: We implanted 51 metallic stents (Architect(®), iVascular) in 17 domestic swine (mean, 25 [3] kg), inserting 1 stent per major coronary artery. Stent postdilatation was performed with different control balloons (n=10) or paclitaxel-eluting balloons: paclitaxel-eluting balloon 1 (iVascular) (n=15); paclitaxel-eluting balloon 2 (iVascular) (n=16) and In.Pact Falcon(®) (Medtronic) (n=10). The restenosis rate (using angiography and histomorphometry) and vascular healing parameters (balloon-related vascular injury score, endothelialization rate, and fibrin and inflammation scores) were analyzed at 28 days. RESULTS: The distinct paclitaxel-eluting balloons showed a similar degree of stenosis at follow-up, which was significantly lower than that in the control group: diameter stenosis was 9% (12%) vs 34% (18%) by angiography (P<.0001) and was 22% (8%) vs 51% (18%) by histomorphometry (P<.0001). Scores for vascular injury (mean, 0.6 [0.5]) and inflammation (mean, 0.8 [0.3]) were uniformly low across all groups. Drug effect markers differed significantly between the paclitaxel-eluting balloons and control groups, with lower endothelialization rates (87% [10%] vs 99% [2%]; P=.0007) and higher fibrin scores (2.1 [0.7] vs 0.4 [0.5]; P<.0001) in the paclitaxel-eluting balloons groups. There were no differences between the different paclitaxel-eluting balloons. CONCLUSIONS: In this preclinical model, the paclitaxel-eluting balloons studied significantly reduced in-stent restenosis compared with the control balloons. Although there were no findings of persistent vascular injury or inflammation, delayed endothelialization and fibrin aggregate suggest a drug deposition response.


Assuntos
Stents Farmacológicos/efeitos adversos , Paclitaxel/administração & dosagem , Animais , Reestenose Coronária/tratamento farmacológico , Modelos Animais , Desenho de Prótese , Suínos , Resultado do Tratamento
10.
Rev. esp. cardiol. (Ed. impr.) ; 70(12): 1059-1066, dic. 2017. ilus, tab, graf
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-169304

RESUMO

Introducción y objetivos: Los nuevos stents farmacoactivos (SFA), diseñados para solventar las limitaciones de los existentes, han de someterse inicialmente al análisis preclínico. El objetivo es analizar la eficacia y la seguridad de nuevos SFA con polímero biodegradable en comparación con stents convencionales (SC) y SFA comercializados en el modelo de arteria coronaria sana porcina. Métodos: Se implantaron aleatoriamente 101 stents (SC y stents liberadores de sirolimus con polímero biodegradable: 3 formulaciones test [BD1, BD2 y BD3], Orsiro, Biomime y Biomatrix) en las arterias coronarias de 34 cerdos domésticos. Se completó estudio angiográfico e histomorfométrico al mes (n = 83) y a los 3 meses (n = 18). Resultados: Los stents se implantaron en proporción stent/arteria de 1,31 ± 0,21, sin diferencias entre grupos. Al mes, los nuevos stents (BD1, BD2 y BD3) mostraron menos pérdida tardía y reestenosis angiográfica, así como menor área neointimal y reestenosis histológica (p < 0,0005) que los SC. No se observaron diferencias significativas entre los nuevos stents y los SC en endotelización, daño vascular o inflamación; solo se encontró mayor persistencia de fibrina en los nuevos (p = 0,0006). A los 3 meses, todas estas diferencias desaparecieron, excepto una menor área neointimal con el nuevo stent BD1 (p = 0,027). No hubo diferencias en ningún parámetro al mes ni a los 3 meses entre los nuevos stents y los comercializados. Conclusiones: En este modelo preclínico, los nuevos SFA con polímero biodegradable estudiados presentan menos reestenosis que los SC, sin diferencias significativas en seguridad y eficacia respecto a SFA comercializados (AU)


Introduction and objectives New drug-eluting stents (DES) designed to overcome the limitations of existing devices should initially be tested in preclinical studies. Our objective was to analyze the safety and efficacy of new biodegradable polymer-based DES compared with bare-metal stents (BMS) and commercially available DES in a model of normal porcine coronary arteries. Methods: We randomly implanted 101 stents (BMS and biodegradable polymer-based sirolimus-eluting stents: 3 test stent iterations [BD1, BD2, and BD3], Orsiro, Biomime and Biomatrix) in the coronary arteries of 34 domestic pigs. Angiographic and histomorphometric studies were conducted 1 month (n = 83) and 3 months (n = 18) later. Results: The stents were implanted at a stent/artery ratio of 1.31 ± 0.21, with no significant differences between groups. At 1 month, the new test stents (BD1, BD2 and BD3) showed less late loss and angiographic restenosis, as well as lower histologic restenosis and neointimal area (P < .0005), than the BMS. There were no differences in endothelialization, vascular injury, or inflammation between the new test stents and BMS, although the new stents showed higher fibrin deposition (P = .0006). At 3 months, all these differences disappeared, except for a lower neointimal area with the new BD1 stent (P = .027). No differences at any time point were observed between the new test stents and commercially available controls. Conclusions: In this preclinical model, the new biodegradable polymer-based DES studied showed less restenosis than BMS and no significant differences in safety or efficacy vs commercially available DES (AU)


Assuntos
Animais , Stents Farmacológicos , Stents Farmacológicos/veterinária , Sirolimo/uso terapêutico , Implantes Absorvíveis , Implantes Absorvíveis/veterinária , Modelos Animais , Resultado do Tratamento , Suínos , Reestenose Coronária/terapia , Reestenose Coronária/veterinária
11.
J Am Assoc Lab Anim Sci ; 50(1): 73-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21333167

RESUMO

Ischemia of the myocardium can lead to reversible or irreversible injury depending on the severity and duration of the preceding ischemia. Here we compared sevoflurane and isoflurane with particular reference to their hemodynamic effects and ability to modify the effects of acute severe myocardial ischemia and reperfusion on ventricular arrhythmias and mortality in a porcine model of myocardial infarction. Female Large White pigs were premedicated with ketamine, midazolam, and atropine. Propofol was given intravenously for the anesthetic induction, and anesthesia was maintained with isoflurane or sevoflurane. Endovascular, fluoroscopy-guided, coronary procedures were performed to occlude the midleft anterior descending artery by using a coronary angioplasty balloon. After 75 min, the balloon catheter system was withdrawn and the presence of adequate reperfusion flow was verified. The pigs were followed for 2 mo, and overall mortality rate was calculated. The isoflurane group showed lower arterial pressure throughout the procedure, with the difference reaching statistical significance after induction of myocardial ischemia. The ventricular fibrillation rate was higher in isoflurane group (81.3%) than the sevoflurane group (51.7%; relative risk, 1.57 [1.03 to 2.4]). Overall survival was lower in the isoflurane group (75%) than the sevoflurane group (96.4%). In conclusion, in this porcine model of myocardial ischemia and reperfusion, sevoflurane was associated with higher hemodynamic stability and fewer ventricular arrhythmias and mortality than was isoflurane.


Assuntos
Anestésicos Inalatórios/uso terapêutico , Arritmias Cardíacas/veterinária , Isoflurano/uso terapêutico , Éteres Metílicos/uso terapêutico , Infarto do Miocárdio/complicações , Traumatismo por Reperfusão Miocárdica/veterinária , Doenças dos Suínos/prevenção & controle , Bem-Estar do Animal , Animais , Arritmias Cardíacas/complicações , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/prevenção & controle , Modelos Animais de Doenças , Feminino , Traumatismo por Reperfusão Miocárdica/complicações , Traumatismo por Reperfusão Miocárdica/mortalidade , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Sevoflurano , Taxa de Sobrevida , Suínos , Doenças dos Suínos/mortalidade
12.
Rev Esp Cardiol ; 64(2): 159-62, 2011 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-21195533

RESUMO

There is histological evidence that drug-eluting stents are associated with delayed endothelialization and a persistent inflammatory state. Moreover, clusters of inflammatory cells have been observed on luminal surfaces by scanning electron microscopy. With the aim of quantifying this inflammatory response, we implanted one bare-metal stent and two drug-eluting stents containing different doses of vinblastine embedded in the same polymer into the coronary arteries of 12 domestic pigs. The density of inflammatory cells in a representative area (100 x 100 µm) was quantified at 3 and 7 days. Endothelialization was more complete in bare-metal stents than in drug-eluting stents at both 3 days (P=.016) and 7 days (P=.0001). The degree of inflammation induced by the drug-eluting stents was higher than that induced by the bare-metal stents at both 3 days (11.8±3.5% vs. 4.5±2%; P=.001) and 7 days (26.3±4.4% vs. 1.2±1.5%; P=.0001). In addition, the time sequence was inverted: the inflammatory response increased over time with the drug-eluting stents, while the opposite occurred with the bare-metal stents.


Assuntos
Vasos Coronários/patologia , Stents Farmacológicos/efeitos adversos , Inflamação/etiologia , Inflamação/patologia , Animais , Reestenose Coronária/patologia , Endotélio Vascular/fisiologia , Microscopia Eletrônica de Varredura , Suínos
15.
J Am Coll Cardiol ; 58(9): 977-86, 2011 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-21723061

RESUMO

OBJECTIVES: The purpose of this study was to test the ability of insulin-like growth factor (IGF)-1/hepatocyte growth factor (HGF) to activate resident endogenous porcine cardiac stem/progenitor cells (epCSCs) and to promote myocardial repair through a clinically applicable intracoronary injection protocol in a pig model of myocardial infarction (MI) relevant to human disease. BACKGROUND: In rodents, cardiac stem/progenitor cell (CSC) transplantation as well as in situ activation through intramyocardial injection of specific growth factors has been shown to result in myocardial regeneration after acute myocardial infarction (AMI). METHODS: Acute MI was induced in pigs by a 60-min percutaneous transluminal coronary angiography left anterior descending artery occlusion. The IGF-1 and HGF were co-administered through the infarct-related artery in a single dose (ranging from 0.5 to 2 µg HGF and 2 to 8 µg IGF-1) 30 min after coronary reperfusion. Pigs were sacrificed 21 days later for dose-response relationship evaluation by immunohistopathology or 2 months later for cardiac function evaluation by cardiac magnetic resonance imaging. RESULTS: The IGF-1/HGF activated c-kit positive-CD45 negative epCSCs and increased their myogenic differentiation in vitro. The IGF-1/HGF, in a dose-dependent manner, improved cardiomyocyte survival, and reduced fibrosis and cardiomyocyte reactive hypertrophy. It significantly increased c-kit positive-CD45 negative epCSC number and fostered the generation of new myocardium (myocytes and microvasculature) in infarcted and peri-infarct/border regions at 21 and 60 days after AMI. The IGF-1/HGF reduced infarct size and improved left ventricular function at 2 months after AMI. CONCLUSIONS: In an animal model of AMI relevant to the human disease, intracoronary administration of IGF-1/HGF is a practical and effective strategy to reduce pathological cardiac remodeling, induce myocardial regeneration, and improve ventricular function.


Assuntos
Vasos Coronários/fisiologia , Fator de Crescimento de Hepatócito/administração & dosagem , Fator de Crescimento Insulin-Like I/administração & dosagem , Infarto do Miocárdio/patologia , Infarto do Miocárdio/terapia , Miócitos Cardíacos/fisiologia , Células-Tronco/metabolismo , Animais , Diferenciação Celular/fisiologia , Sobrevivência Celular/fisiologia , Vasos Coronários/citologia , Quimioterapia Combinada , Feminino , Fator de Crescimento de Hepatócito/fisiologia , Humanos , Injeções Intra-Arteriais , Fator de Crescimento Insulin-Like I/fisiologia , Miócitos Cardíacos/citologia , Células-Tronco/citologia , Suínos
16.
Rev. esp. cardiol. (Ed. impr.) ; 68(12): 1118-1124, dic. 2015. ilus, tab, graf
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-145618

RESUMO

Introducción y objetivos: En el proceso de mejora de los polímeros, las plataformas y los sistemas de liberación de fármacos en los nuevos diseños de stents farmacoactivos, el análisis preclínico inicial es obligatorio. El objetivo es analizar la eficacia y la seguridad de nuevos modelos de stentsfarmacoactivos en comparación con un stent convencional y stents farmacoactivos comercializados en el modelo experimental de arteria coronaria sana porcina. Métodos: Se implantaron aleatoriamente 60 stents (stent convencional, nuevos stents liberadores de sirolimus: stents liberadores de fármaco 1, 2 y 3; Cypher® y Xience®) en las arterias coronarias de 20 cerdos domésticos raza Large White. Se realizó estudio angiográfico e histomorfométrico a los 28 días. Resultados: Los stents se implantaron en proporción stent/arteria de 1,34 ± 0,15, sin diferencias significativas entre grupos. Los nuevos stents mostraron menos pérdida tardía y restenosis angiográfica que los convencionales (p = 0,006 y p < 0,001 respectivamente). Todas las nuevas plataformas presentaron menos área neointimal y restenosis histológica que losstents convencionales (p < 0,001 para cada variable), sin diferencias con los farmacoactivos comercializados. En cuanto a la seguridad, todos los stents farmacoactivos mostraron menos endotelización que los convencionales, salvo el stent liberador de fármaco 3 (p = 0,084). Asimismo, la inflamación observada fue menor con el stent liberador de fármaco 3 que con los demás. Conclusiones: Las nuevas plataformas de stents farmacoactivos estudiadas se asocian con menos restenosis que los convencionales, sin diferencias significativas en seguridad y eficacia respecto a los stents farmacoactivos comercializados (AU)


Introduction and objectives: Initial preclinical studies are required during the process of improving polymers, platforms, and drug-eluting systems for new coronary stent designs. Our objective was to analyze the efficacy and safety of new drug-eluting stent models compared with a conventional stent and commercialized drug-eluting stents in an experimental model with healthy porcine coronary arteries. Methods: Sixty stents (conventional stent, new sirolimus-eluting stents: drug-eluting stents 1, 2 and 3; Cypher® and Xience®) were randomly placed in the coronary arteries of 20 Large White domestic pigs. Angiographic and histomorphometric studies were done 28 days later. Results: The stents were implanted at a stent/artery ratio of 1.34 ± 0.15, with no significant differences between groups. The new stents showed less late loss and angiographic restenosis than conventional stents (P = .006 and P < .001, respectively). Histologically, restenosis and neointimal area were lower with all the new platforms than with the conventional stents (P < .001 for each variable), and no differences were found vs the drug-eluting stents on the market. Safety data showed that endothelialization was lower with drug-eluting stents than with conventional stents, except for drug-eluting stent 3 (P = .084). Likewise, inflammation was lower with drug-eluting stent 3 than with other stents. Conclusions: The new drug-eluting stent platforms studied are associated with less restenosis than conventional stents and showed no significant differences in safety or efficacy vs commercialized drug-eluting stents (AU)


Assuntos
Animais , Sirolimo/administração & dosagem , Stents Farmacológicos , Remodelação Vascular , Reestenose Coronária/tratamento farmacológico , Segurança do Paciente , Resultado do Tratamento , Modelos Animais de Doenças
17.
J Pharmacol Toxicol Methods ; 60(3): 301-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19490947

RESUMO

INTRODUCTION: Progress in cardiovascular regenerative medicine research requires the availability of appropriate experimental animal models that are as close to humans as feasible. Our objective was to assess the validity of a porcine endovascular model of myocardial infarction and reperfusion. METHODS: Fifteen domestic pigs (Large White race) were anesthetized and pre-medicated with amiodarone. Endovascular fluoroscopy-guided coronary procedures were performed to occlude the mid-left anterior descending artery using a coronary angioplasty balloon. Occlusion was confirmed by angiography and electrocardiography. After 75 min the balloon catheter system was withdrawn and the presence of reperfusion flow was verified. The animals were sacrificed after 1 and 2 weeks of follow-up, the hearts were explanted, and the extent of myocardial infarction with respect to the left ventricle was quantified. RESULTS: Overall survival rate was 67%. Five animals died prematurely: 3 showing signs of heart failure, 1 had reperfusion failure (final TIMI flow grade 1) and 1 succumbed to acute stress. The most common adverse event was ventricular fibrillation (87% of the animals) and defibrillation was effective in all affected animals. The extent of myocardial infarct in the animals followed-up for 1 and 2 weeks was similar (20.4+/-4.3% vs. 20.9+/-2.8%, respectively; p=0.8) but was significantly greater in the animals that died prematurely (29.5+/-3.6%, p=0.02). CONCLUSIONS: The endovascular porcine model we have explored constitutes a feasible and reproducible alternative for the evaluation of human myocardial infarction and reperfusion.


Assuntos
Modelos Animais de Doenças , Infarto do Miocárdio/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Animais , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Masculino , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Sus scrofa , Suínos
18.
Rev Esp Cardiol ; 62(2): 126-35, 2009 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-19232185

RESUMO

INTRODUCTION AND OBJECTIVES: Poor response to antiplatelet therapy has been associated with adverse long-term outcomes. The objective of this study is to assess the relationship between response to clopidogrel and post-treatment platelet reactivity (PPR) and 1-year major adverse cardiovascular events (MACE) in patients with non-ST segment elevation acute coronary syndrome (NSTEACS). METHODS: Patients with NSTEACS undergoing early coronary angiography were enrolled in this prospective, observational study. The VerifyNow analyzer was used to measure clopidogrel response and PPR immediately before coronary angiography. RESULTS: Of the 179 patients included (97 percutaneous coronary intervention, 21 coronary artery bypass graft), 161 (90%) completed 1-year follow-up and 18 (11%) incurred MACE: 10 deaths, 6 myocardial infarctions, 2 strokes, 5 revascularizations. Lower response to clopidogrel (31 +/- 21% vs. 43 +/- 21%; P.049) and higher PPR (204 +/- 60 vs. 155 +/- 67 platelet reaction units [PRU]; p= 0.006) were significantly associated with MACE occurrence. Multivariate analysis confirmed PPR (OR per 10-unit increase: 1.12, 95%CI: 1.01-1.24; P.020) as an independent predictor of MACE. A PPR cut-off value of 175 PRU was associated with an adjusted OR for 1-year MACE occurrence of 3.9 (95%CI: 1.2-15.4; P.024). CONCLUSIONS: PPR predicts adverse long-term outcomes better than response to clopidogrel in patients with NSTEACS. Patients with PPR values above 175 PRU were identified as being at higher risk for adverse long-term events.


Assuntos
Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/cirurgia , Plaquetas/fisiologia , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Testes de Função Plaquetária , Ticlopidina/análogos & derivados , Idoso , Angioplastia Coronária com Balão , Clopidogrel , Ponte de Artéria Coronária , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/epidemiologia , Valor Preditivo dos Testes , Prognóstico , Ticlopidina/efeitos adversos , Ticlopidina/uso terapêutico , Resultado do Tratamento
19.
Rev. esp. cardiol. (Ed. impr.) ; 67(6): 456-462, jun. 2014. ilus, tab
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-123219

RESUMO

Introducción y objetivos Los balones liberadores de paclitaxel tienen demostrada eficacia en el tratamiento y la prevención de la restenosis. Sin embargo, no todos los dispositivos comercializados son igualmente efectivos; por ello es importante comparar los resultados en un modelo preclínico. Nuestro objetivo es analizar la seguridad y la eficacia preclínicas de distintos dispositivos. Métodos En 17 cerdos domésticos (25 ± 3 kg) se implantaron 51 stents metálicos (Architect®, iVascular), uno en cada rama coronaria principal, y se sobredilataron con distintos balones de control (n = 10) o liberadores de paclitaxel: balón liberador de paclitaxel 1 (iVascular) (n = 15); balón liberador de paclitaxel 2 (iVascular) (n = 16) e In. Pact Falcon® (Medtronic) (n = 10). Tras 28 días, se analizaron los resultados de restenosis (angiografía e histomorfometría) y de reparación vascular: daño vascular, endotelización, persistencia de fibrina e inflamación. Resultados Los distintos balones liberadores de paclitaxel mostraron valores similares de estenosis en el seguimiento significativamente menores que los controles: angiografía, el 9 ± 12% frente al 34 ± 18% (p < 0,0001); histomorfometría, el 22 ± 8% frente al 51 ± 18% (p < 0,0001). Los grados de daño vascular (0,6 ± 0,5) e inflamación (0,8 ± 0,3) fueron bajos, sin diferencias entre los grupos. Los marcadores del efecto farmacológico fueron significativamente distintos entre los dispositivos liberadores de paclitaxel (sin diferencias entre ellos) y los controles: superficie endotelizada, el 87 ± 10% frente al 99 ± 2% (p = 0,0007); grado de fibrina, 2,1 ± 0,7 frente a 0,4 ± 0,5 (p < 0,0001). No hubo diferencias entre los distintos balones liberadores de paclitaxel. Conclusiones: En este modelo preclínico, los balones liberadores de paclitaxel analizados mostraron una reducción significativa de la restenosis. Aunque no se observaron datos de daño vascular o inflamación persistentes, sí se apreciaron los efectos de la acción farmacológica en forma de endotelización retrasada y acumulación de fibrina


Introduction and objectives Paclitaxel-eluting balloons have shown high antiproliferative efficacy in the treatment and prevention of restenosis. Nevertheless, not all available devices are equally effective, which makes it interesting to compare results in a preclinical model. Our objective was to assess the preclinical efficacy and safety of different devices. Methods We implanted 51 metallic stents (Architect®, iVascular) in 17 domestic swine (mean, 25 [3] kg), inserting 1 stent per major coronary artery. Stent postdilatation was performed with different control balloons (n = 10) or paclitaxel-eluting balloons: paclitaxel-eluting balloon 1 (iVascular) (n = 15); paclitaxel-eluting balloon 2 (iVascular) (n = 16) and In.Pact Falcon®(Medtronic) (n = 10). The restenosis rate (using angiography and histomorphometry) and vascular healing parameters (balloon-related vascular injury score, endothelialization rate, and fibrin and inflammation scores) were analyzed at 28 days. Results The distinct paclitaxel-eluting balloons showed a similar degree of stenosis at follow-up, which was significantly lower than that in the control group: diameter stenosis was 9% (12%) vs 34% (18%) by angiography (P < .0001) and was 22% (8%) vs 51% (18%) by histomorphometry (P < .0001). Scores for vascular injury (mean, 0.6 [0.5]) and inflammation (mean, 0.8 [0.3]) were uniformly low across all groups. Drug effect markers differed significantly between the paclitaxel-eluting balloons and control groups, with lower endothelialization rates (87% [10%] vs 99% [2%]; P = .0007) and higher fibrin scores (2.1 [0.7] vs 0.4 [0.5]; P < .0001) in the paclitaxel-eluting balloons groups. There were no differences between the different paclitaxel-eluting balloons. Conclusions: In this preclinical model, the paclitaxel-eluting balloons studied significantly reduced in-stent restenosis compared with the control balloons. Although there were no findings of persistent vascular injury or inflammation, delayed endothelialization and fibrin aggregate suggest a drug deposition response


Assuntos
Animais , Paclitaxel/farmacocinética , Stents Farmacológicos , Reestenose Coronária/tratamento farmacológico , Reperfusão Miocárdica/métodos , Suínos , Segurança do Paciente , Modelos Animais de Doenças
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA