Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Prosthet Dent ; 125(2): 266-272, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32111393

RESUMO

STATEMENT OF PROBLEM: Correct implant placement by means of a pretreatment planning software program is still subject to deviations between the planned and achieved implant positions. Inaccuracy at this level may have drastic consequences, including neurovascular trauma. Further data are therefore needed to evaluate the accuracy of such computer-guided implant planning software programs. PURPOSE: The purpose of this clinical study was to evaluate the accuracy of computer-guided implant surgery associated with prototyped surgical guides. MATERIAL AND METHODS: Cone beam computed tomography (CBCT) scans were made of the participants with a tomographic guide to merge anatomic and prosthetic data. This allowed virtual planning with a prosthetically guided approach respecting the anatomy of the participant. A prototyped surgical guide was then fabricated from the virtual plan, determining the intrasurgical position of the implants. Flapless guided implant surgery was carried out according to the manufacturer's instructions. A second CBCT was made 30 days after the surgery, to enable overlapping of the data from before and after the implant placement. The angular, coronal, central, and apical deviations of the placed implants were measured and compared with those virtually planned. The data were submitted to descriptive statistic and intraclass correlation coefficient (ICC), analysis of variance, and the Student t test (α=.05). RESULTS: A total of 61 implants were analyzed. The mean angular deviation was 2.04 degrees. The mean coronal, central, and apical linear deviations were 0.68 mm, 0.72 mm, and 0.82 mm, respectively. No statistically significant difference was found between the virtual and the real position of the implants inserted. A tendency toward a greater absolute error was observed in the mandible than in the maxilla in terms of angular (P=.047), central (P=.043), and coronal error (P=.031). CONCLUSIONS: Flapless computer-guided implant surgery with virtual planning had some angular and linear deviations; nevertheless, this technique should be acceptably safe and accurate.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Computadores , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Humanos , Imageamento Tridimensional , Planejamento de Assistência ao Paciente
2.
Rev. Odontol. Araçatuba (Impr.) ; 40(1): 29-34, jan.-abr. 2019. ilus
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-995154

RESUMO

O objetivo deste relato de caso clínico foi descrever a importância de planejar de maneira minuciosa uma alternativa de reabilitação conservadora de um paciente em uso de bisfosfonato intravenoso, bem como detalhar os procedimentos realizados. Paciente do gênero masculino, 78 anos, buscou atendimento odontológico relatando insatisfação com sua condição dentária atual, e o desejo de realizar novas próteses dentárias. Ao exame clínico, observou-se instabilidade da prótese parcial removível superior devido à fratura coronária do elemento 26. Ao exame radiográfico, observaram-se extensas lesões cariosas nos dentes 16 e 26. Após plano de tratamento realizado em equipe multidisciplinar, foi sugerida uma reabilitação sem nenhum procedimento cirúrgico, a fim de minimizar as complicações pós-operatórias e proporcionar saúde oral de maneira mais breve e minimamente invasiva. O tratamento incluiu a confecção de uma prótese parcial fixa dos elementos 13 ao 23 com encaixes de precisão associada à uma prótese parcial removível superior. Já para a arcada inferior, foi realizada uma prótese parcial fixa dos elementos 33 ao 41 e uma prótese parcial removível. Por meio deste caso clinico, foi possível concluir que uma abordagem conservadora possibilitou uma reabilitação que supriu as necessidades estéticas e funcionais do paciente que faz uso de medicamento antirreabsortivo(AU)


The aim of this study was to describe the importance of a carefully planning to conservative rehabilitation alternative for a patient using intravenous bisphosphonate, as well as to detail the procedures performed. A male patient, 78 years old, sought dental care reporting dissatisfaction with his current dental condition and the desire to perform new dental prostheses. At the clinical examination, instability of the superior removable partial denture was observed due to the coronary fracture of element 26. Radiographic examination revealed extensive carious lesions on teeth 16 and 26. After a multidisciplinary treatment planning, was suggested a rehabilitation without any surgical procedure, in order to minimize postoperative complications and provide oral health in a minor and minimally invasive manner. Treatment included a fixed partial denture of elements 13 to 23 with precision fittings attachments associated with a removable partial denture. To the jaw, a fixed partial prosthesis of elements 33 to 41 and a partial removable prosthesis were performed. Through this clinical case, it was possible to conclude that a conservative management provides an aesthetical and functional patient rehabilitation who take antiresorptive medication(AU)


Assuntos
Humanos , Masculino , Idoso , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Reabilitação Bucal , Prótese Parcial Fixa , Prótese Parcial Removível , Difosfonatos
3.
ImplantNewsPerio ; 2(2): 227-233, mar.-abr. 2017. ilus, tab
Artigo em Português | LILACS, BBO - odontologia (Brasil) | ID: biblio-847144

RESUMO

Objetivo: avaliar, por meio de um microdurômetro, o grau de desajuste na adaptação de pilares Ucla em implantes. Material e métodos: foram utilizados dez implantes de hexágono interno de plataforma regular, e seus respectivos componentes protéticos do tipo Ucla com antirrotacional, como seguem: dez pilares Ucla totalmente calcináveis e dez pilares Ucla com base de CoCr. Todos os pilares Ucla foram fundidos pelo mesmo laboratório de prótese e pelo mesmo processo laboratorial. Cada implante recebeu apenas dois pilares, que foram anexados por meio de um parafuso de titânio quadrado utilizando-se torque de 30 Ncm com torquímetro manual. Cada conjunto implante/pilar recebeu quatro marcações aleatórias em torno da circunferência, na qual foram feitas as medições do espaço existente entre as peças utilizando uma lupa estereoscópica de 100 vezes de aumento. Resultados: os resultados obtidos mostraram diferenças significativas entre os grupos submetidos ao teste Mann-Whitney (p < 0,05). Conclusão: o pilar Ucla com base de CoCr apresentou menor desajuste marginal vertical, quando comparado ao pilar Ucla totalmente calcinável, após o processo de fundição nos implantes de hexágono interno.


Objective: to evaluate, using a microhardness device, the misfit between Ucla abutments and internal hex implants. Material and methods: 10 internal hex implants received 10 Ucla burnout and 10 Ucla abutments with CoCr collar. All the abutments were cast in the same laboratory and under the same protocol. A square-head titanium screw was tightened to a 30 Ncm using a manual wrench. Each abutment/implant set receive four random markings around its perimeter. A stereoscopic lens was used to investigate the misfi t at 100 magnification. Results: there was a statistically significant difference between tested abutments (Mann-Whitney p < 0.05). Conclusion: the Ucla abutment with the CoCr collar presented less vertica misfit values after casting for internal hex dental implants.


Assuntos
Interpretação Estatística de Dados , Revestimento para Fundição Odontológica , Técnica de Fundição Odontológica/instrumentação , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Prótese Dentária Fixada por Implante/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA