Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Res ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849480

RESUMO

BACKGROUND: Children with congenital heart disease (CHD) demonstrate long-term neurodevelopmental impairments. We investigated contrast-enhanced ultrasound (CEUS) cerebral perfusion in a fetal animal model exposed to sub-physiologic oxygen at equivalent levels observed in human fetuses with CHD. METHODS: Fifteen fetal lambs [hypoxic animals (n = 9) and normoxic controls (n = 6)] maintained in an extrauterine environment underwent periodic brain CEUS. Perfusion parameters including microvascular flow velocity (MFV), transit time, and microvascular blood flow (MBF) were extrapolated from a standardized plane; regions of interest (ROI) included whole brain, central/thalami, and peripheral parenchymal analyses. Daily echocardiographic parameters and middle cerebral artery (MCA) pulsatility indices (PIs) were obtained. RESULTS: Hypoxic lambs demonstrated decreased MFV, increased transit time, and decreased MBF (p = 0.026, p = 0.016, and p < 0.001, respectively) by whole brain analyses. MFV and transit time were relatively preserved in the central/thalami (p = 0.11, p = 0.08, p = 0.012, respectively) with differences in the peripheral parenchyma (all p < 0.001). In general, cardiac variables did not correlate with cerebral CEUS perfusion parameters. Hypoxic animals demonstrated decreased MCA PI compared to controls (0.65 vs. 0.78, respectively; p = 0.027). CONCLUSION: Aberrations in CEUS perfusion parameters suggest that in environments of prolonged hypoxia, there are regional microvascular differences incompletely characterized by MCA interrogation offering insights into fetal conditions which may contribute to patient outcomes. IMPACT: This work utilizes CEUS to study cerebral microvascular perfusion in a unique fetal animal model subjected to chronic hypoxic conditions equal to fetuses with congenital heart disease. CEUS demonstrates altered parameters with regional differences that are incompletely characterized by MCA Doppler values. These findings show that routine MCA Doppler interrogation may be inadequate in assessing microvascular perfusion differences. To our knowledge, this study is the first to utilize CEUS to assess microvascular perfusion in this model. The results offer insight into underlying conditions and physiological changes which may contribute to known neurodevelopmental impairments in those with congenital heart disease.

2.
Pediatr Res ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834782

RESUMO

BACKGROUND: Our team has previously reported physiologic support by the EXTra-uterine Environment for Neonatal Development (EXTEND) of 105 to 117 days gestational age (GA) lambs for up to 28 days with normal organ maturation. However, the fetal lamb brain matures more rapidly, requiring the study of 90-105 day GA fetal lambs to assess more neurodevelopmentally equivalent lambs to the 23-25 week GA extreme premature infant. METHODS: Extremely preterm lambs (90-95 days of GA) were delivered by C-section and supported by EXTEND. Estimated circuit flows were maintained at around 325 ml/kg/min. After support on EXTEND, MRI and histopathologic analysis were performed and compared to 105-112 days GA control lambs. RESULTS: The extremely preterm group includes 10 animals with a mean GA of 91.6 days, a mean weight at cannulation of 0.98 kg and a mean length of stay on EXTEND of 13.5 days (10-21 days). Hemodynamics and oxygenation showed stable parameters. Animals showed growth and physiologic cardiac function. MRI volumetric and diffusion analysis was comparable to controls. Histologic brain analysis revealed no difference between study groups. CONCLUSION: EXTEND appears to support brain and cardiac development in an earlier gestation, less mature, lamb model. IMPACT: Prolonged (up to 21 days) physiological support of extremely preterm lambs of closer neurodevelopmental equivalence to the 24-28 gestational week human was achieved using the EXTEND system. EXTEND treatment supported brain growth and development in extremely preterm fetal lambs and was not associated with intraventricular hemorrhage or white matter injury. Daily echocardiography demonstrated physiologic heart function, absence of cardiac afterload, and normal developmental increase in cardiac chamber dimensions. This study demonstrates hemodynamic and metabolic support by the EXTEND system in the extremely preterm ovine model.

3.
J Hepatol ; 79(6): 1396-1407, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37611641

RESUMO

BACKGROUND & AIMS: Biliary atresia (BA) is an obstructive cholangiopathy that initially affects the extrahepatic bile ducts (EHBDs) of neonates. The etiology is uncertain, but evidence points to a prenatal cause. Fetal tissues have increased levels of hyaluronic acid (HA), which plays an integral role in fetal wound healing. The objective of this study was to determine whether a program of fetal wound healing is part of the response to fetal EHBD injury. METHODS: Mouse, rat, sheep, and human EHBD samples were studied at different developmental time points. Models included a fetal sheep model of prenatal hypoxia, human BA EHBD remnants and liver samples taken at the time of the Kasai procedure, EHBDs isolated from neonatal rats and mice, and spheroids and other models generated from primary neonatal mouse cholangiocytes. RESULTS: A wide layer of high molecular weight HA encircling the lumen was characteristic of the normal perinatal but not adult EHBD. This layer, which was surrounded by collagen, expanded in injured ducts in parallel with extensive peribiliary gland hyperplasia, increased mucus production and elevated serum bilirubin levels. BA EHBD remnants similarly showed increased HA centered around ductular structures compared with age-appropriate controls. High molecular weight HA typical of the fetal/neonatal ducts caused increased cholangiocyte spheroid growth, whereas low molecular weight HA induced abnormal epithelial morphology; low molecular weight HA caused matrix swelling in a bile duct-on-a-chip device. CONCLUSION: The fetal/neonatal EHBD, including in human EHBD remnants from Kasai surgeries, demonstrated an injury response with prolonged high levels of HA typical of fetal wound healing. The expanded peri-luminal HA layer may swell and lead to elevated bilirubin levels and obstruction of the EHBD. IMPACT AND IMPLICATIONS: Biliary atresia is a pediatric cholangiopathy associated with high morbidity and mortality rates; although multiple etiologies have been proposed, the fetal response to bile duct damage is largely unknown. This study explores the fetal pathogenesis after extrahepatic bile duct damage, thereby opening a completely new avenue to study therapeutic targets in the context of biliary atresia.


Assuntos
Ductos Biliares Extra-Hepáticos , Atresia Biliar , Humanos , Animais , Camundongos , Ratos , Criança , Ovinos , Atresia Biliar/patologia , Ductos Biliares Extra-Hepáticos/patologia , Feto/patologia , Cicatrização , Bilirrubina
4.
Cardiol Young ; 33(3): 432-436, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35438073

RESUMO

Nearly one in five children with CHD is born with white matter injury that can be recognised on postnatal MRI by the presence of T1 hyperintense lesions. This pattern of white matter injury is known to portend poor neurodevelopmental outcomes, but the exact aetiology and histologic characterisation of these lesions have never been described. A fetal sheep was cannulated at gestational age 110 days onto a pumpless extracorporeal oxygenator via the umbilical vessels and supported in a fluid environment for 14.5 days. The fetus was supported under hypoxic conditions (mean oxygen delivery 16 ml/kg/day) to simulate the in utero conditions of CHD. At necropsy, the brain was fixed, imaged with MRI, and then stained to histologically identify areas of injury. Under hypoxemic in utero conditions, the fetus developed a T1 hyperintense lesion in its right frontal lobe. Histologically, this lesion was characterised by microvascular proliferation and astrocytosis without gliosis. These findings may provide valuable insight into the aetiology of white matter injury in neonates with CHD.


Assuntos
Lesões Encefálicas , Substância Branca , Ovinos , Animais , Humanos , Substância Branca/diagnóstico por imagem , Idade Gestacional , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Feto/patologia
5.
Pediatr Dev Pathol ; 25(3): 253-262, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35102770

RESUMO

Despite advances in clinical care and modest improvement in mortality rates for extreme prematurity, morbidity remains a significant challenge. The ideal environment to support prematurity would be fluidic and rely on natural fetal circulation to mimic the natural fetal amniotic environment, yet such an environment has been unsuccessful in long-term support until recently. Our group has succeeded in developing such a support system to foster fetal growth in the premature lamb model that shows promise for clinical translation. Here, we describe the EXTrauterine Environment for Neonatal Development (EXTEND) from its conception onwards, review published literature on fetal development and support of the premature lamb model in EXTEND, and discuss future applications.


Assuntos
Nascimento Prematuro , Âmnio , Animais , Feminino , Desenvolvimento Fetal , Feto , Humanos , Pulmão , Ovinos
6.
Cardiol Young ; 32(5): 732-737, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34365994

RESUMO

OBJECTIVES: The objective of this study was to investigate changes in serum biomarkers of acute brain injury, including white matter and astrocyte injury during chronic foetal hypoxaemia. We have previously shown histopathological changes in myelination and neuronal density in fetuses with chronic foetal hypoxaemia at a level consistent with CHD. METHODS: Mid-gestation foetal sheep (110 ± 3 days gestation) were cannulated and attached to a pumpless, low-resistance oxygenator circuit, and incubated in a sterile fluid environment mimicking the intrauterine environment. Fetuses were maintained with an oxygen delivery of 20-25 ml/kg/min (normoxemia) or 14-16 ml/kg/min (hypoxaemia). Myelin Basic Protein and Glial Fibrillary Acidic Protein serum levels in the two groups were assessed by ELISA at baseline and at 7, 14, and 21 days of support. RESULTS: Based on overlapping 95% confidence intervals, there were no statistically significant differences in either Myelin Basic Protein or Glial Fibrillary Acidic Protein serum levels between the normoxemic and hypoxemic groups, at any time point. No statistically significant correlations were observed between oxygen delivery and levels of Myelin Basic Protein and Glial Fibrillary Acidic Protein. CONCLUSION: Chronic foetal hypoxaemia during mid-gestation is not associated with elevated serum levels of acute white matter (Myelin Basic Protein) or astrocyte injury (Glial Fibrillary Acidic Protein), in this model. In conjunction with our previously reported findings, our data support the hypothesis that the brain dysmaturity with impaired myelination found in fetuses with chronic hypoxaemia is caused by disruption of normal developmental pathways rather than by direct cellular injury.


Assuntos
Lesões Encefálicas , Proteína Básica da Mielina , Animais , Biomarcadores , Lesões Encefálicas/complicações , Feminino , Feto , Proteína Glial Fibrilar Ácida , Humanos , Hipóxia , Proteína Básica da Mielina/análise , Proteína Básica da Mielina/metabolismo , Oxigênio/metabolismo , Gravidez , Ovinos
7.
Prenat Diagn ; 41(1): 145-158, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32875581

RESUMO

Extreme prematurity remains a major cause of neonatal mortality and severe long-term morbidity. Current neonatal care is associated with significant morbidity due to iatrogenic injury and developmental immaturity of extreme premature infants. A more physiologic approach, replacing placental function and providing a womb-like environment, is the foundational principle of artificial placenta (AP) and womb (AW) technology. The concept has been studied during the past 60 years with limited success. However, recent technological advancements and a greater emphasis on mimicking utero-placental physiology have improved the success of experimental models, bringing the technology closer to clinical translation. Here, we review the rationale for and history of AP and AW technology, discuss the challenges that needed to be overcome, and compare recent successful models. We conclude by outlining some remaining challenges to be addressed on the path towards clinical translation and opportunities for future research.


Assuntos
Órgãos Artificiais , Lactente Extremamente Prematuro , Terapia Intensiva Neonatal , Placenta , Útero , Animais , Feminino , Humanos , Recém-Nascido , Gravidez , Pesquisa Translacional Biomédica
8.
Prenat Diagn ; 41(13): 1668-1674, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34480376

RESUMO

OBJECTIVE: To compare and validate umbilical venous flow volume (UVFV) measured at the intra-abdominal portion using ultrasound with actual flow volume of umbilical vein (UV) in fetal sheep sustained on the EXTrauterine Environment for Neonatal Development (EXTEND) system. METHODS: Circuit flow volume through the oxygenator was obtained using sensors. Ultrasound derived UVFV (ml/min) was calculated as (UV diameter [cm]/2)2 × 3.14 × maximum velocity (cm/s) × 0.5 × 60, measured at approximately the mid portion between its abdominal insertion and the origin of the ductus venosus. UVFV was measured by ultrasound once daily and was compared to the average of daily circuit flow volume directly measured. RESULTS: UVFV was measured 168 times in 15 fetal sheep. The ratio of circuit flow volume to combined cardiac output remained stable within the anticipated physiological range throughout. UVFV measured by ultrasound showed good correlation to directly measured circuit flow (r = 0.72). Interclass correlation coefficients for intra-observer variability was 0.991 (95% confidence interval [CI], 0.979-0.996). CONCLUSION: UVFV measured at the intra-abdominal portion using ultrasound shows a good correlation with directly measured circuit flow volume in UV of fetal sheep on the EXTEND system. Regular incorporation of such validated UVFV measures into clinical use may offer opportunities to better understand conditions of placental dysfunction.


Assuntos
Placenta/irrigação sanguínea , Ultrassonografia Pré-Natal/métodos , Veias Umbilicais/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Feminino , Idade Gestacional , Placenta/diagnóstico por imagem , Placenta/fisiopatologia , Gravidez , Ovinos , Veias Umbilicais/fisiopatologia , Pressão Venosa/fisiologia
9.
J Ultrasound Med ; 40(12): 2571-2579, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33512029

RESUMO

OBJECTIVES: Contrast-enhanced ultrasound (CEUS) can provide quantitative perfusion metrics and may be useful to detect cerebral pathology in neonates and premature infants, particularly in extrauterine environments. The effect of hemodynamics on cerebral perfusion metrics is unknown, which limits the clinical application of this technology. We aimed to determine associations between systemic hemodynamics and concurrently measured brain perfusion parameters in an animal model of extrauterine support. METHODS: Nine fetal lambs were transferred to an extrauterine support device. Lumason® ultrasound contrast (0.1-0.3 ml) was administered via the umbilical vein and 90-second cine clips were obtained. Time-intensity-curves (TICs) were generated and time-dependent and area-under-curve (AUC) parameters were derived. Associations between brain perfusion metrics and hemodynamics including heart rate (HR) and mean arterial pressure (MAP) were evaluated by multilevel linear mixed-effects models. RESULTS: Eighty-six ultrasound examinations were performed and 72 examinations were quantifiable. Time-dependent measurements were independent of all hemodynamic parameters (all p ≥.05). Oxygen delivery and mean blood flow were correlated with AUC measurements (all p ≤.01). Physiologic HR and MAP were not correlated with any measurements (all p ≥.05). CONCLUSION: Detected aberrations in time-dependent CEUS measurements are not correlated with hemodynamic parameters and are thought to reflect the changes in cerebral blood flow, thus providing a promising tool for evaluation of brain perfusion. CEUS brain perfusion parameters are not correlated with physiologic HR and MAP, but AUC-dependent measurements are correlated with oxygen delivery and blood flow, suggesting that CEUS offers additional value over standard monitoring. Overall, these findings enhance the applicability of this technology.


Assuntos
Benchmarking , Hemodinâmica , Animais , Encéfalo/diagnóstico por imagem , Meios de Contraste , Modelos Animais de Doenças , Humanos , Perfusão , Ovinos , Ultrassonografia
10.
Pediatr Radiol ; 51(1): 103-111, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32870357

RESUMO

BACKGROUND: With the development of an artificial environment to support the extremely premature infant, advanced imaging techniques tested in this extrauterine system might be beneficial to evaluate the fetal brain. OBJECTIVE: We evaluated the feasibility of (a) performing contrast-enhanced ultrasound (CEUS) and (b) quantifying normal and decreased brain perfusion in fetal lambs maintained on the extrauterine environment for neonatal development (EXTEND) system. MATERIALS AND METHODS: Twin premature fetal lambs (102 days of gestational age) were transferred to the EXTEND system. Twin B was subjected to sub-physiological flows (152 mL/kg/min) and oxygen delivery (15.9 mL/kg/min), while Twin A was maintained at physiological levels. We administered Lumason contrast agent into the oxygenator circuit and performed serial CEUS examinations. We quantified perfusion parameters and generated parametric maps. We also recorded hemodynamic parameters, serum blood analysis, and measurements across the oxygenator. Postmortem MRIs were performed. RESULTS: No significant changes in hemodynamic variables were attributable to CEUS examinations. On gray-scale images, Twin B demonstrated ventriculomegaly and progressive parenchymal volume loss culminating in hydranencephaly. By CEUS, Twin B demonstrated decreased peak enhancement and decreased overall parenchymal perfusion when compared to Twin A by perfusion parameters and parametric maps. Changes in perfusion parameters were detected immediately following blood transfusion. Postmortem MRI confirmed ultrasonographic findings in Twin B. CONCLUSION: In this preliminary experience, we show that CEUS of the brain is feasible in fetal lambs maintained on the EXTEND system and that changes in perfusion can be quantified, which is promising for the application of CEUS in this extrauterine system supporting the premature infant.


Assuntos
Meios de Contraste , Feto , Animais , Encéfalo/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Ovinos , Ultrassonografia
11.
Fetal Diagn Ther ; 47(12): 939-946, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32877895

RESUMO

In this model article, we present a protocol for continuous amniotic fluid exchange in rabbits using a novel system to test the effects of growth factor-deficient, artificial amniotic fluid on bowel development. BACKGROUND: Ideally, the EXTrauterine Environment for Neonatal Development (EXTEND) will provide physiologic support to the extreme premature infant. An important component of that environment is the amniotic fluid. Thus, we developed an animal model to study the growth factors found within amniotic fluid and inform design of a synthetic fluid to optimize fetal development. METHODS: We designed a model of amniotic fluid exchange within the pregnant rabbit, continuously removing the natural fluid from around 2 fetuses per doe and replacing it with a physiologic electrolyte solution during the final 100 h of gestation. Two fetuses from the contralateral uterine horn were used as sham-operated controls. Thirty-eight fetuses were analyzed, 19 in each group. We analyzed the fetal growth and bowel development. RESULTS: Ultrasound after 100 h of exchange showed equivalent fluid volumes, p = 0.63. Cultures were negative for bacterial colonization. Final fluid protein concentrations were 11.6% that of control fluid (mean 1,451 ± 224.2 vs. 12,491 ± 849.2 µg/mL). There was no significant difference in fetal growth, with experimental weights 91.4% of control weights, p = 0.07. Fetal bowel weights (90.1%, p = 0.16) and lengths (94.2%, p = 0.49) were also not significantly less compared to controls. There was no significant difference in villous height or crypt depth measurements between the groups, and absorptive capacity of the bowel was not different between groups, p = 0.44. CONCLUSION: This animal model allows for manipulation of the components of amniotic fluid. Marked reduction of natural amniotic fluid proteins during gestation does not appear to significantly impair fetal growth or bowel development. Further work with this model will assess the importance of amniotic fluid components for normal development to inform design of a synthetic fluid for use during EXTEND.


Assuntos
Líquido Amniótico , Desenvolvimento Fetal , Animais , Modelos Animais de Doenças , Feminino , Peso Fetal , Intestinos , Gravidez , Coelhos
12.
Artif Organs ; 43(12): 1154-1161, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31237960

RESUMO

EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system for supporting extremely premature infants that replicates in utero conditions by maintaining a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit connected to the umbilical vessels. Target gestational age (GA) for EXTEND support in human infants is 23-27 weeks, when immature lungs are most susceptible to injury in the setting of air ventilation. We previously demonstrated physiologic support of premature lambs cannulated at 105-117 days GA (lungs developmentally analogous to the 23-27 week GA human infant) for up to 28 days on EXTEND. In the present study, we sought to determine the technical feasibility of umbilical vessel cannulation in 85-96 days GA lambs delivered to EXTEND at weights equivalent to the 23-27 week GA human infant (500-850 g). Five preterm lambs were cannulated at 85-96 days GA (term 145 days) and supported on EXTEND for 4-7 days. All lambs underwent umbilical artery and umbilical vein cannulation. Circuit flows and pressures were monitored continuously, and blood gases were obtained at regular intervals for assessment of oxygen parameters. Systemic pH and lactate were measured at least once daily. Mean body weight at cannulation was 641 ± 71 g (range 480-850 g). All lambs were cannulated successfully (cannula size varied from 8 to 12 Fr), and mean survival on EXTEND was 140 ± 7 hours. Mean circuit flow was 213 ± 15 mL/kg*min, mean pH was 7.37 ± 0.01, and mean lactate was 1.6 ± 0.2 mmol/L. During the initial 120 hours after EXTEND cannulation, there were no significant differences between 85-96 days GA lambs and 105-117 days GA lambs in weight-adjusted circuit flows, oxygen delivery, pH, or lactate levels. This study demonstrates successful umbilical cord cannulation and adequate circuit flows and oxygen delivery in midgestation lambs size-matched to the 23-27 week GA human fetus, which represents an important step in the translation of EXTEND to clinical practice.


Assuntos
Cateterismo/instrumentação , Oxigenação por Membrana Extracorpórea/instrumentação , Nascimento Prematuro/terapia , Cordão Umbilical , Animais , Animais Recém-Nascidos , Desenho de Equipamento , Estudos de Viabilidade , Hemodinâmica , Humanos , Incubadoras para Lactentes , Lactente Extremamente Prematuro , Recém-Nascido , Masculino , Carneiro Doméstico , Cordão Umbilical/fisiologia
13.
J Ultrasound Med ; 38(8): 1971-1978, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30560564

RESUMO

OBJECTIVES: To evaluate the effects of ultrasound contrast agent (UCA) administration on hemodynamic parameters and support equipment in in vitro and in vivo models of extracorporeal support. METHODS: In vitro, incrementally increasing bolus doses of a UCA were administered proximal to a membrane oxygenator, and ultrasound cine clips were obtained. The rates of microbubble destruction across the oxygenator and over time were calculated from time-intensity-curves. Measurements across the membrane oxygenator were recorded and compared by a repeated-measures analysis of variance. In vivo, 7 premature fetal lambs were transferred from placental support to the extrauterine environment for neonatal development. Contrast agent boluses were administered for contrast-enhanced ultrasound (CEUS) examinations. Hemodynamic parameters and serum laboratory values were evaluated before and after the examinations by paired t tests. For oxygenator staining, oxygenator membranes from the in vitro circuit, study animals (n = 4), and control animals (n = 4) were stained for the adherent UCA. RESULTS: In vitro, with all doses (0.1-4 mL), there was no difference in measured parameters across the oxygenator (P ≥ .09). Contrast agent destruction (3%-14%) across the oxygenator was observed at the first pass with a progressive decline in contrast intensity over time. In vivo, there was no difference in hemodynamic parameters or serum laboratory values (P ≥ .08) with any CEUS examination (n = 17). For oxygenator staining, all oxygenator membranes were negative for UCA with lipid staining. CONCLUSIONS: The UCA had no detectable effect on the oxygenator or measured parameters in in vitro and in vivo studies, thus providing additional safety data to support the use of CEUS in the setting of extracorporeal support.


Assuntos
Meios de Contraste , Oxigenação por Membrana Extracorpórea/métodos , Desenvolvimento Fetal/fisiologia , Hemodinâmica/fisiologia , Aumento da Imagem/métodos , Ultrassonografia/métodos , Animais , Animais Recém-Nascidos , Desenho de Equipamento , Feminino , Técnicas In Vitro , Microbolhas , Modelos Animais , Oxigenadores de Membrana , Gravidez , Nascimento Prematuro , Ovinos
14.
Fetal Diagn Ther ; 45(3): 176-183, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29953976

RESUMO

INTRODUCTION: We have recently developed an extra-uterine environment for neonatal development (EXTEND) capable of supporting premature fetal lambs and have been able to replicate hypoxic in utero conditions by controlling fetal oxygen delivery. In this study, we investigated the fetal mitochondrial response to hypoxia. METHODS: Eight premature fetal lambs were delivered via hysterotomy and transitioned to extra-uterine support for 3 weeks. The lambs were divided into 2 groups: normoxic fetuses which maintained physiologic oxygen delivery and hypoxic fetuses in which oxygen delivery was significantly reduced. Control fetuses were delivered via hysterotomy but not cannulated. Measurements of mitochondrial membrane potential (MMP) were performed in peripheral blood mononuclear cells. RESULTS: There were no significant differences in MMP between normoxic EXTEND fetuses and controls. Hypoxic fetuses had significantly more depolarized mitochondria compared to normoxic fetuses overall, and these changes were specifically appreciated in weeks 1 and 2, but not by week 3. Hypoxic fetuses had significantly elevated levels of HIF-1α compared to normoxic fetuses in the first 2 weeks. DISCUSSION: Normoxic fetal lambs supported by EXTEND demonstrate normal mitochondrial function as evidenced by equivalent membrane potentials compared to control fetuses. Hypoxic fetuses exhibit mitochondrial dysfunction, though they do show evidence of adaptation after 3 weeks of hypoxic exposure.


Assuntos
Hipóxia Fetal/metabolismo , Subunidade alfa do Fator 1 Induzível por Hipóxia/sangue , Potencial da Membrana Mitocondrial/fisiologia , Insuficiência Placentária/metabolismo , Animais , Feminino , Hipóxia Fetal/sangue , Insuficiência Placentária/sangue , Gravidez , Ovinos
15.
Fetal Diagn Ther ; 46(5): 306-312, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30861524

RESUMO

BACKGROUND: In an effort to mitigate the major morbidities and mortality associated with extreme prematurity, we have developed an EXTrauterine Environment for Neonatal Development (EXTEND) designed to provide physiologic support of extremely premature infants. OBJECTIVES: We have previously shown that long-term, physiologic support of premature fetal lambs is possible with EXTEND, but in this study, we sought to demonstrate bioenergetic equipoise at the tissue level. METHODS: Four premature fetal lambs were delivered by hysterotomy at gestational ages (GA) of 105-107 days (term ∼145 days), cannulated via the umbilical vessels, and transitioned to support on EXTEND for 3-4 weeks. Five control fetuses were age-matched to the GA of experimental fetuses at the time of study end (128-134 days GA) and immediately sacrificed after hysterotomy. Mitochondria were isolated from the heart, liver, kidney, and skeletal muscle of fetuses at the time of sacrifice, and oxygen consumption rates (OCRs) were measured. RESULTS: There were no differences in basal mitochondrial OCR between EXTEND and control fetuses for heart, kidney, or skeletal muscle. For liver, the basal OCR was higher in EXTEND fetuses compared to controls. There were no differences in physiologic maximal OCR or reserve capacity for any tissue analyzed. CONCLUSIONS: Fetal lambs supported by EXTEND demonstrate physiologic mitochondrial function as evidenced by adequate basal and physiologic maximal cellular respiration as well as preserved reserve capacity.


Assuntos
Órgãos Artificiais , Metabolismo Energético , Oxigenação por Membrana Extracorpórea , Mitocôndrias/metabolismo , Nascimento Prematuro/terapia , 8-Hidroxi-2'-Desoxiguanosina/sangue , Animais , Animais Recém-Nascidos , Bilirrubina/sangue , Biomarcadores/sangue , Respiração Celular , Oxigenação por Membrana Extracorpórea/instrumentação , Feminino , Monitorização Fetal , Idade Gestacional , Consumo de Oxigênio , Oxigenadores de Membrana , Gravidez , Nascimento Prematuro/metabolismo , Nascimento Prematuro/fisiopatologia , Carneiro Doméstico , Fatores de Tempo
16.
Fetal Diagn Ther ; 46(4): 231-237, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30703769

RESUMO

BACKGROUND: We recently developed an EXTrauterine Environment for Neonatal Development (EXTEND) that provides physiologic support for premature lambs. Here, we assess the efficacy of exogenous erythropoietin (EPO) to prevent anemia and transfusions on EXTEND. MATERIALS AND METHODS: Lambs were cannulated at 0.7 gestation and supported on EXTEND for up to 4 weeks. The lambs were divided into three groups: (1) No EPO, (2) Low EPO (300 U kg-1 per day), and (3) High EPO (800 U kg-1 per day). Daily hematocrit and weekly complete blood count were assessed. RESULTS: The mean percentage change in hematocrit from baseline was significantly different between the groups (No EPO -23.6 ± 7.8% vs. Low EPO -16.6 ± 6.4% vs. High EPO +2.6 ± 6.6%; p = 0.02). This occurred despite a greater median number of blood transfusions in the No EPO group (5 vs. 1 vs. 0; p = 0.02). EPO administration was associated with a higher mean corpuscular volume (MCV; p < 0.01) and reticulocyte count (p = 0.02). The High EPO group was comparable to in utero control fetuses with respect to hematocrit (p = 0.49), MCV (p = 0.24), and reticulocyte count (p = 0.68). CONCLUSIONS: EPO (800 U kg-1 per day) prevents anemia, eliminates transfusions, and restores normal red blood cell indices in premature lambs supported by EXTEND.


Assuntos
Anemia/prevenção & controle , Eritropoetina/uso terapêutico , Terapia Intensiva Neonatal/métodos , Animais , Avaliação Pré-Clínica de Medicamentos , Oxigênio/sangue , Ovinos
17.
J Physiol ; 596(9): 1575-1585, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29392729

RESUMO

KEY POINTS: Bronchopulmonary dysplasia is a disease of extreme prematurity that occurs when the immature lung is exposed to gas ventilation. We designed a novel 'artificial womb' system for supporting extreme premature lambs (called EXTEND) that obviates gas ventilation by providing oxygen via a pumpless arteriovenous circuit with the lamb submerged in sterile artificial amniotic fluid. In the present study, we compare different arteriovenous cannulation strategies on EXTEND, including carotid artery/jugular vein (CA/JV), carotid artery/umbilical vein (CA/UV) and umbilical artery/umbilical vein (UA/UV). Compared to CA/JV and CA/UV cannulation, UA/UV cannulation provided significantly higher, physiological blood flows to the oxygenator, minimized flow interruptions and supported significantly longer circuit runs (up to 4 weeks). Physiological circuit blood flow in UA/UV lambs made possible normal levels of oxygen delivery, which is a critical step toward the clinical application of artificial womb technology. ABSTRACT: EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system that promotes physiological development by maintaining the premature lamb in a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit. During the development of EXTEND, different cannulation strategies evolved with the aim of improving circuit flow. The present study examines how different cannulation strategies affect EXTEND circuit haemodynamics in extreme premature lambs. Seventeen premature lambs were cannulated at gestational ages 105-117 days (term 145-150 days) and supported on EXTEND for up to 4 weeks. Experimental groups were distinguished by cannulation strategy: carotid artery outflow and jugular vein inflow (CA/JV; n = 4), carotid artery outflow and umbilical vein inflow (CA/UV; n = 5) and double umbilical artery outflow and umbilical vein inflow (UA/UV; n = 8). Circuit flows and pressures were measured continuously. As we transitioned from CA/JV to CA/UV to UA/UV cannulation, mean duration of circuit run and weight-adjusted circuit flows increased (P < 0.001) and the frequency of flow interruptions declined (P < 0.05). Umbilical vessels generally accommodated larger-bore cannulas, and cannula calibre was directly correlated with circuit pressures and indirectly correlated with flow:pressure ratio (a measure of post-membrane resistance). We conclude that UA/UV cannulation in fetal lambs on EXTEND optimizes circuit flow dynamics and flow stability and also supports circuit flows that closely approximate normal placental flow.


Assuntos
Cateterismo/métodos , Hemodinâmica , Pulmão/crescimento & desenvolvimento , Oxigênio/metabolismo , Nascimento Prematuro/terapia , Artérias Umbilicais/fisiologia , Veias Umbilicais/fisiologia , Animais , Animais Recém-Nascidos , Feminino , Pulmão/fisiologia , Placenta/fisiologia , Gravidez , Nascimento Prematuro/fisiopatologia , Ovinos , Ventilação
18.
Pediatr Res ; 80(4): 577-85, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27376883

RESUMO

BACKGROUND: Pulmonary hypoplasia and hypertension is a leading cause of morbidity and mortality in congenital diaphragmatic hernia (CDH). The etiologic insult occurs early in gestation highlighting the potential of prenatal interventions. We evaluated prenatal pharmacologic therapies in the nitrofen CDH model. METHODS: Olive oil or nitrofen were administered alone or with dexamethasone (DM), sildenafil, or DM+sildenafil to pregnant rats. Newborn pups were assessed for lung function, structure and pulmonary artery (PA) flow and resistance. RESULTS: Prenatal DM treatment of CDH pups increased alveolar volume density (Vva), decreased interalveloar septal thickness, increased tidal volumes and improved ventilation without improving oxygenation or PA resistance. Sildenafil decreased PA resistance and improved oxygenation without improving ventilation or resulting in significant histologic changes. DM+sildenafil decreased PA resistance, improved oxygenation and ventilation while increasing Vva and decreasing interalveolar septal and pulmonary arteriole medial wall thickness. Lung and body weights were decreased in pups treated with DM and/or sildenafil. CONCLUSION: Prenatal DM or sildenafil treatment increased pulmonary compliance and decreased pulmonary vascular resistance respectively, and was associated with improved neonatal gas exchange but had a detrimental effect on lung and fetal growth. This study highlights the potential of individual and combined prenatal pharmacologic therapies for CDH management.


Assuntos
Dexametasona/administração & dosagem , Hérnias Diafragmáticas Congênitas/tratamento farmacológico , Pulmão/irrigação sanguínea , Testes de Função Respiratória , Citrato de Sildenafila/administração & dosagem , Animais , Arteríolas/fisiopatologia , Peso Corporal , Feminino , Hérnias Diafragmáticas Congênitas/induzido quimicamente , Hipertensão Pulmonar/tratamento farmacológico , Pulmão/efeitos dos fármacos , Azeite de Oliva/química , Tamanho do Órgão/efeitos dos fármacos , Oxigênio/química , Éteres Fenílicos/efeitos adversos , Gravidez , Prenhez , Artéria Pulmonar/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Fenômenos Fisiológicos Respiratórios , Volume Sistólico , Traqueia/efeitos dos fármacos
19.
Prenat Diagn ; 32(1): 39-44, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22052745

RESUMO

OBJECTIVE: Prenatal tracheal occlusion (TO) promotes lung growth and is applied clinically in fetuses with severe congenital diaphragmatic hernia. Limited data are available regarding the effect of duration of TO on lung development. Our objective was to evaluate the effects of long (2 and 2.5 days) versus short (1 day) TO on lung development in rats with nitrofen-induced diaphragmatic hernia. METHOD: Nitrofen was administered on embryonic day (ED) 9 and fetal TO performed either on ED18.5, 19 or 20 (term = 22 days). Sham-operated and untouched littermates served as controls. On ED21, lungs were harvested and only fetuses with a left-sided diaphragmatic defect were included in further analyses. RESULTS: Lung-body-weight ratio incrementally increased with the duration of TO. Increased proliferation following long TO was confirmed by immunohistochemistry and qRT-PCR for the proliferation marker Ki-67. Irrespective of duration, TO induced more complex airway architecture. Medial wall thickness of pulmonary arteries was thinner after long rather than short TO. CONCLUSION: In the nitrofen rat model of congenital diaphragmatic hernia, a longer period of TO leads to enhanced lung growth and less muscularized pulmonary arteries.


Assuntos
Doenças Fetais/cirurgia , Hérnias Diafragmáticas Congênitas , Pulmão/embriologia , Traqueia/cirurgia , Animais , Proliferação de Células/efeitos dos fármacos , Modelos Animais de Doenças , Feminino , Feto/anormalidades , Feto/cirurgia , Idade Gestacional , Herbicidas/toxicidade , Hérnia Diafragmática/induzido quimicamente , Hérnia Diafragmática/patologia , Hérnia Diafragmática/cirurgia , Pulmão/efeitos dos fármacos , Pulmão/patologia , Tamanho do Órgão , Éteres Fenílicos/toxicidade , Gravidez , Ratos , Ratos Wistar , Fatores de Tempo
20.
JTCVS Open ; 10: 342-349, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36004209

RESUMO

Objective: The molecular pathways underlying hypoxemia-induced alterations in neurodevelopment of infants with congenital heart disease have not been delineated. We used transcriptome analysis to investigate differential gene expression induced by hypoxemia in an ovine artificial-womb model. Methods: Mid-gestation fetal sheep (median [interquartile range] 109 [107-112] days' gestation) were cannulated via the umbilical vessels, attached to a pumpless, low-resistance oxygenator circuit, and incubated in a sterile, fluid environment for 22 [21-23] days. Fetuses were maintained with an oxygen delivery of 20-25 mL/kg/min (normoxemia, n = 3) or 14-16 mL/kg/min (hypoxemia, n = 4). Transcriptional profiling by RNA sequencing was carried out on left frontal brains and hypoxemia-regulated genes were identified by differential gene expression analysis. Results: A total of 228 genes whose expression was up or down regulated by ≥1.5-fold (false discovery rate ≤0.05) were identified. The majority of these genes were induced in hypoxemic animals compared to normoxemic controls, and functional enrichment analysis identified respiratory electron transport as a pathway strongly upregulated in the brain during chronic hypoxemia. Further examination of hypoxemia-induced genes showed robust induction of all 7 subunits of the mitochondrial NADH:ubiquinone oxidoreductase (complex I). Other hypoxemia-induced genes included cytochrome B, a component of complex III, and ATP6, ATP8, both of which are components of complex V. Conclusions: Chronic fetal hypoxemia leads to upregulation of multiple mitochondrial respiratory complex genes critical for energy production and reactive oxygen species generation, including complex I. These data provide valuable insight into potential pathways involved in chronic hypoxemia-induced neuropathology and offers potential therapeutic targets for fetal neuroprotection in fetuses with congenital heart defects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA