Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 23(6): 5399-409, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26564196

RESUMO

Within the last few years, the presence of bentazone herbicide has been observed in many water resources. For the first time, removal of bentazone using mesoporous silica was investigated revealing reversible adsorption. The adsorption isotherm was well described using the Freundlich model. The affinity towards bentazone is strongly affected by pH in the range of 2-7, decreasing with the increase of the pH, becoming negligible at the neutrality. Regeneration of the adsorbent was possible, and a recovery as high as 70 % was obtained using CH3OH-NaOH solution. Furthermore, appreciable recovery (47 %) was also obtained using water. Applications on the purification of lake water and wastewaters, both characterized by a significant organic carbon load, spiked with 2 mg L(-1) bentazone were tested, observing removal yields in the range of 61-73 %. Taking advantage of the fast adsorption kinetics observed, an in-flow purification treatment was set-up, with quantitative removal of bentazone from polluted water.


Assuntos
Benzotiadiazinas/química , Herbicidas/química , Dióxido de Silício/química , Poluentes Químicos da Água/química , Purificação da Água/métodos , Adsorção , Meio Ambiente , Cinética
2.
Talanta ; 131: 205-12, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25281094

RESUMO

In this work the electrochemical behavior of substances of environmental concern [bentazone, atrazine, carbamazepine, phenytoin and its metabolite 5-(4-hydroxyphenyl)-5-phenylhydantoin, HPPH] on a glassy carbon working electrode (Ag/AgCl reference electrode) was studied with the aim to develop a HPLC method coupled with amperometric detection. Constant potential (DC), pulsed amperometric detection modes were studied. For the pulsed mode, several waveforms were set and investigated. Detection conditions were optimized as a function of eluent pH. In order to reduce the limits of detection and to analyze natural water samples, a SPE protocol was optimized to be coupled to the developed procedure. For this aim, five sorbents of different physico-chemical characteristics were tested optimizing a recovery procedure for each of the cartridge evaluated. At the optimized SPE conditions, recoveries were included in the range (R=90.2-100.5% for all the analytes, with excellent reproducibility (<%, n=3). The method detection limits obtained by pulsed amperometry after the SPE protocol (preconcentration factor 100) were 113 ng L(-1) (0.47 nmol L(-1)), 67 ng L(-1) (0.25 nmol L(-1)), 234 ng L(-1) (1.1 nmol L(-1)), for bentazone, HPPH and carbamazepine, respectively. Robustness of the method was assessed for each analyte at a concentration level corresponding to about three times the limit of detection, through the evaluation of intra-day (n=13) and inter-day tests (4 days, n=52). Finally the method was successfully applied for the analysis of a river sample (Po River, Turin, Italy).


Assuntos
Atrazina/análise , Benzotiadiazinas/análise , Carbamazepina/análise , Cromatografia Líquida de Alta Pressão/métodos , Herbicidas/análise , Fenitoína/análise , Extração em Fase Sólida/métodos , Carbono/química , Eletroquímica , Eletrodos , Rios , Poluentes Químicos da Água/análise
3.
J Chromatogr A ; 1265: 31-8, 2012 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-23084486

RESUMO

A new technology equipment for low-pressure microwave assisted extraction (usually employed for organic chemistry reactions), recently launched in the market, is used for the first time in environmental analysis for the extraction of commercial technical Aroclor mixtures from soil. Certified reference materials of Aroclor 1260, Aroclor 1254 and Aroclor 1242 in transformer oils were used to contaminate the soil samples and to optimize the extraction method as well as the subsequent gas chromatographic electron capture detection (GC-ECD) analytical method. The study was performed optimizing the extraction, the purification and the gas chromatographic separation conditions to enhance the resolution of difficult pairs of congeners (C28/31 and C141/179). After optimization, the recovery yields were included within the range 79-84%. The detection limits, evaluated for two different commercial polychlorinated biphenyl (PCB) mixtures (Aroclor 1260 and Aroclor 1242) were 0.056 ± 0.001 mg/kg and 0.290 ± 0.006 mg/kg, respectively. The method, validated with certified soil samples, was used to analyze a soil sample after an event of failure of a pole-mounted transformer which caused the dumping of PCB contaminated oil in soil. Moreover, the method provides simple sample handling, fast extraction with reduced amount of sample and solvents than usually required, and simple purification step involving the use of solvent (cyclohexane) volumes as low as 5 mL. Reliability and reproducibility of extraction conditions are ensured by direct and continuous monitoring of temperature and pressure conditions.


Assuntos
Cromatografia Gasosa/métodos , Micro-Ondas , Bifenilos Policlorados/análise , Pressão , Poluentes do Solo/análise , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA