1.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37846769

RESUMO

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Criocirurgia/métodos , Itália/epidemiologia , Sistema de Registros , Ablação por Cateter/métodos , Recidiva
2.
J Cardiovasc Electrophysiol ; 33(7): 1587-1589, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35557022

RESUMO

INTRODUCTION: A new dielectric-based method (KODEX-EPD mapping system, EPD Solutions, a Philips company) for measuring tissue thickness at the catheter-tissue interface has recently been developed. We reported preliminarydata on real-time catheter-based measuring myocardial wall thickness in vivo, during typical atrial flutter radio frequency ablation. METHODS AND RESULTS: The study population consisted of 12 consecutive patients, suffering from symptomatic paroxysmal or persistent cavo-tricuspid isthmus dependent, counter clockwise and clockwise AFL, under going a first catheter ablation between April 2021 and November 2021. The new KODEX-EPD function, Wall Viever, was used to calculate atrialwall thickness. The atrial wall thickness was significantly higher closeto the tricuspid annulus than close to the inferior vena cava (3.6 ± 0.5 mm vs 2.4 ± 0.3 mm, p < .001) and a trend towards a progressive decrease of atrial wall thickness was observed moving the mapping catheter from the tricuspidvalve to the inferior vena cava. CONCLUSIONS: Thenew KODEX-EPD function, Wall Viever, allowed us to assess atrial wall thickness during atrial flutter radio frequency ablation.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Humanos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
3.
J Cardiovasc Electrophysiol ; 33(7): 1414-1424, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35524404

RESUMO

INTRODUCTION: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system. METHODS: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity. The Lumipoint™ (Boston Scientific) map-analysis tool was used sequentially on each PV component. The ablation endpoint was PV isolation (PVI) and electrical quiescence in the antral region. RESULTS: Fifty-eight cases of AF ablation were analyzed. A total of 86 PVGs in 34 (58.6%) patients and 44 RAPs in 34 patients (58.6%) were found. In 16 (27.6%) cases, we found at least one RAP in patients with complete absence of PV conduction. RAPs showed a lower mean voltage than PVG (0.3 ± 0.2 mV vs. 0.7 ± 0.5 mV, p < .0001), whereas the mean number of electrogram peaks was higher (8.4 ± 1.4 vs. 3.2 ± 1.5, p < .0001). The percentage of patients in whom RAPs were detected through Lumipoint™ was higher than through propagation map analysis (58.6% vs. 36.2%, p = .025). Acute procedural success was 100%, with all PVs successfully isolated and RAPs completely abolished in all study patients. During a mean follow-up of 453 ± 133 days, 6 patients (10.3%) suffered an AF/AT recurrence. CONCLUSION: Local vulnerabilities in antral lesion sets were easily discernible by means of the UHDM system in both de novo and redo patients when no PV conduction was present.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
4.
Heart Vessels ; 37(1): 115-120, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34240266

RESUMO

Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX-EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system. In a retrospective, single center study, we enrolled 34 consecutive patients with paroxysmal AF divided in two groups: 17 patients in Conventional Group underwent the procedure under fluoroscopy guidance before the new system introduction, while 17 patient in KODEX-EPD Group underwent the procedure under fluoroscopy and KODEX-EPD imaging system guidance. There were no differences in any clinical and anatomical characteristics between the two study groups. Overall procedure time was comparable between the two groups (69 [IQR 63-98] min in Conventional Group vs. 65 [IQR 58-74] min in KODEX-EPD Group, p = 0.16), while fluoroscopy time (8 [IQR 5-9] min vs. 11 [IQR 9-12] min, p = 0.014) and dye use (35 [IQR 28-45] ml vs. 70 [IQR 57-83] ml, p < 0.001) were significantly lower in the KODEX-EPD Group. No 30-day complications were observed. At 12-month follow-up 7/37 (19%) patients had an atrial arrhythmias recurrence, without any difference between the two study groups (17.6% vs. 23.5%, p = 0.68). The use of a new dielectric imaging system allowed a significantly reduction in radiation exposure and dye use during CB ablation in patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Meios de Contraste , Fluoroscopia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
Int J Mol Sci ; 23(15)2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35955601

RESUMO

In this work, an innovative model is proposed as a design tool to predict both the inner and outer radii in rolled structures based on polydimethylsiloxane bilayers. The model represents an improvement of Timoshenko's formula taking into account the friction arising from contacts between layers arising from rolling by more than one turn, hence broadening its application field towards materials based on elastomeric bilayers capable of large deformations. The fabricated structures were also provided with surface topographical features that would make them potentially usable in different application scenarios, including cell/tissue engineering ones. The bilayer design parameters were varied, such as the initial strain (from 20 to 60%) and the bilayer thickness (from 373 to 93 µm). The model matched experimental data on the inner and outer radii nicely, especially when a high friction condition was implemented in the model, particularly reducing the error below 2% for the outer diameter while varying the strain. The model outperformed the current literature, where self-penetration is not excluded, and a single value of the radius of spontaneous rolling is used to describe multiple rolls. A complex 3D bioinspired hierarchical elastomeric microstructure made of seven spirals arranged like a hexagon inscribed in a circumference, similar to typical biological architectures (e.g., myofibrils within a sarcolemma), was also developed. In this case also, the model effectively predicted the spirals' features (error smaller than 18%), opening interesting application scenarios in the modeling and fabrication of bioinspired materials.


Assuntos
Materiais Biomiméticos , Materiais Biomiméticos/química
6.
J Cardiovasc Electrophysiol ; 32(6): 1540-1548, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33851484

RESUMO

BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
Acta Oncol ; 60(2): 215-221, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32945701

RESUMO

AIM: To evaluate differences between MR-guided daily-adaptive RT (MRgRT) and image-guided RT (IGRT) with or without fiducial markers in prostate cancer (PCa) stereotactic body radiotherapy (SBRT) in terms of dose distribution on critical structures. MATERIAL AND METHODS: Two hundred treatment sessions in 40 patients affected by low and intermediate PCa were evaluated. The prescribed dose was 35 Gy in 5 fractions delivered on alternate days. MRgRT patients (10) were daily recontoured, re-planned, and treated with IMRT technique. IGRT patients without (20) and with (10) fiducials were matched on soft tissues or fiducials and treated with VMAT technique. Respective CBCTs were retrospectively delineated and the prescribed plan was overlaid for dosimetric analysis. The daily dose for rectum, bladder, and prostate was registered. RESULTS: MRgRT resulted in a significantly lower rate of constraints violation as compared to IGRT without fiducials, especially for rectum V28Gy, rectum V32Gy, rectum V35Gy, rectum Dmax, and bladder Dmax. IGRT with fiducials reported high accuracy levels, comparable to MRgRT. MRgRT and IGRT with fiducials reported no significant prostate CTV underdosage, while IGRT without fiducials was associated with occasional cases of prostate CTV under dosage. CONCLUSION: MR-guided daily-adaptive SBRT seems a feasible and accurate strategy for treating prostate cancer with ablative doses. IGRT with the use of fiducials provides a comparable level of accuracy and acceptable real-dose distribution over treatment fractions. Future study will provide additional data regarding the tolerability and the clinical outcome of this new technological approach.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
8.
Pacing Clin Electrophysiol ; 44(10): 1717-1723, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34498748

RESUMO

INTRODUCTION: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. This study aimed to clarify the contribution of contact force (CF) and temperature and their interrelationship in making an adequate lesion with the vHPSD catheter. METHODS: We enrolled 46 consecutive patients undergoing first catheter ablation for atrial fibrillation (AF). The vHPSD ablation was performed applying 90 W, for 4 s, with an irrigation of 8 ml/min. During an application, an impedance drop (ID) ≥10 Ω was regarded as an adequate lesion formation. RESULTS: The mean procedural time was 95 ± 15 min. First-pass isolation was reached in 89% of patients and at the end of the procedure all pulmonary veins were isolated. No steam pop nor procedural complication occurred. A total of 3829 qualified RF points were analyzed and the median values of ID, CF and maximum temperature were respectively 10.6 (IQR 8.6-13.1) Ohm, 9 (5.8-13.8) g, 46.8 (44.1-49.8) °C. The mean ID significantly increased in parallel with the increasing CF as well as with the increasing maximum temperature. In the multivariable analysis only the CF and the maximum temperature were independent predictors of ID. From receiver operating characteristic curve analysis, a CF of 8 g and a maximum temperature of 47°C are the optimal cutoff discriminatory value for adequate lesion formation. CONCLUSIONS: The vHPSD ablation is highly effective and safe. The CF and the maximum temperature are independent predictors of adequate lesion formation assessed by means of ID.


Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Feminino , Temperatura Alta , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Irrigação Terapêutica
9.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
10.
Radiol Med ; 126(7): 989-997, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33835309

RESUMO

OBJECTIVES: To report preliminary data on feasibility and patient-reported outcomes following PSMA-PET/CT guided SBRT by means of 1.5 T MRI-Linac. METHODS AND MATERIALS: Between October 2019 and April 2020, twenty consecutive castration sensitive oligorecurrent prostate cancer patients were enrolled in an ethical committee approved prospective observational study (Protocol n. XXXX) and treated with PSMA-PET/CT guided SBRT by means of 1.5 T MRI-Linac (Unity, Elekta AB, Stockholm, Sweden). The mean delivered dose was 35 Gy in 5 fractions. Clinicians reported toxicity was prospectively collected according to Common Terminology Criteria for Adverse Events v5.0. Quality of life (QoL) assessment was performed using EORTC-QLQ C30 questionnaires administered at baseline, end of treatment and at first follow-up. RESULTS: Twenty-five lesions in 20 castration sensitive oligorecurrent patients were treated: the most commonly treated anatomic sites were nodal (n = 16) and pelvic bone (n = 9). Median PSA-value preMRI guided SBRT was 1.16 ng/mL (range, 0.27-8.9), whereas median PSA value at first follow-up after SBRT was 0.44 ng/mL (range, 0.06-8.15). At first follow-up, for 16 patients showing detectable PSA, PSMA-PET/CT was performed detecting, respectively, in 6 cases partial response and in 10 cases complete response. In the remaining cases, PSA-value was undetectable after SBRT. Radiotherapy treatment was safe and well tolerated according to the PROMs. No acute G2 or higher toxicities were recorded. CONCLUSIONS: The current series represent the largest one exploring the feasibility and patient-reported outcomes following PSMA-PET/CT guided SBRT by means of 1.5 T MRI-Linac. The preliminary findings here reported are encouraging in terms of effectiveness and tolerability.


Assuntos
Imageamento por Ressonância Magnética/métodos , Medidas de Resultados Relatados pelo Paciente , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos , Idoso , Idoso de 80 Anos ou mais , Castração , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico
11.
J Cardiovasc Electrophysiol ; 31(9): 2319-2327, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32613661

RESUMO

INTRODUCTION: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated. METHODS AND RESULTS: Consecutive patients undergoing AF ablation from the CHARISMA registry at five Italian centers were included. A novel radiofrequency (RF) ablation catheter with a dedicated algorithm (DIRECTSENSE™) was used to measure LI and to guide ablation. The ablation endpoint was pulmonary vein (PV) isolation. We analyzed 2219 ablation spots created around PVs in 46 patients for AF ablation. The mean baseline tissue impedance was 105.8 ± 14 Ω for LI versus 91.8 ± 10 Ω for GI (p < .0001). Baseline impedance was homogenous across the PV sites and proved higher in high-voltage areas than in intermediate- and low-voltage areas and the blood pool (p < .001). Both LI and GI displayed a significant drop after RF delivery, and absolute LI drop values were significantly larger than GI drop values (14 ± 8 vs. 3.7 ± 5 Ω, p < .0001). Every 5-point increment in LI drop was associated with successful ablation (odds ratio = 3.05, 95% confidence interval: 2.3-4.1, p < .0001). Conversely, GI drops were not significantly different comparing successful versus unsuccessful sites (3.7 ± 5 vs. 2.8 ± 4 Ω, p = .1099). No steam pops or major complications occurred during or after the procedures. By the end of the procedures, all PVs had been successfully isolated in all patients. CONCLUSIONS: The magnitude of the LI drop was more closely associated with effective lesion formation than the GI drop.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Humanos , Projetos Piloto , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 31(7): 1694-1701, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32369225

RESUMO

BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Reprodutibilidade dos Testes , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 42(7): 874-881, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045257

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes
14.
Europace ; 19(9): 1493-1499, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28407139

RESUMO

AIMS: Heart failure (HF) patients with implantable cardioverter-defibrillators (ICD) require admissions for disease management and out-patient visits for disease management and assessment of device performance. These admissions place a significant burden on the National Health Service. Remote monitoring (RM) is an effective alternative to frequent hospital visits. The EFFECT study was a multicentre observational investigation aiming to evaluate the clinical effectiveness of RM compared with in-office visits standard management (SM). The present analysis is an economic evaluation of the results of the EFFECT trial. METHODS AND RESULTS: The present analysis considered the direct consumption of healthcare resources over 12-month follow-up. Standard tariffs were applied to hospitalizations, in-office visits and remote device interrogations. Economic comparisons were also carried out by means of propensity score (PS) analysis to take into account the lack of randomization in the study design. The analysis involved 858 patients with ICD or CRT-D. Of these, 401 (47%) were followed up via an SM approach, while 457 (53%) were assigned to RM. The rate of hospitalizations was 0.27/year in the SM group and 0.16/year in the RM group (risk reduction =0.59; P = 0.0004). In the non-adjusted analysis, the annual cost for each patient was €817 in the SM group and €604 in the RM group (P = 0.014). Propensity score analysis, in which 292 RM patients were matched with 292 SM patients, confirmed the results of the non-adjusted analysis (€872 in the SM group vs. €757 in the RM group; P < 0.0001). CONCLUSION: There is a reduction in direct healthcare costs of RM for HF patients with ICDs, particularly CRT-D, compared with standard monitoring. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier, NCT01723865.


Assuntos
Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Visita a Consultório Médico/economia , Tecnologia de Sensoriamento Remoto/economia , Telemetria/economia , Idoso , Assistência Ambulatorial/economia , Distribuição de Qui-Quadrado , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Humanos , Itália , Masculino , Modelos Econômicos , Readmissão do Paciente/economia , Valor Preditivo dos Testes , Pontuação de Propensão , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 40(7): 850-856, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28543265

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) has proved to be effective in patients with heart failure and left bundle branch block (LBBB). Recently, new electrocardiography criteria have been proposed for the diagnosis of LBBB. These criteria are stricter than the current American Heart Association (AHA) criteria. We assessed the rate of echocardiographic response to CRT in patients with traditional LBBB versus patients who met the new criteria (strict LBBB). METHODS: Consecutive patients undergoing CRT were enrolled in the CRT MORE registry. Patients with no-LBBB QRS morphology according to AHA criteria, atrial fibrillation, right bundle branch block, and right ventricular pacing were excluded. Strict LBBB was defined as: QRS ≥ 140 ms for men and ≥130 ms for women, QS or rS in V1-V2, mid-QRS notching or slurring in ≥2 contiguous leads. Patients showing a relative decrease of ≥15% in left ventricular end-systolic volume (LVESV) at 12 months were defined as responders. RESULTS: Among 335 patients with LBBB, 131 (39%) had strict LBBB. Patients with and without strict LBBB showed comparable baseline characteristics, except for QRS duration (166 ± 20 ms vs 152 ± 25 ms, P < 0.001). On 12-month evaluation, 205 patients (61%) were responders; 85 of 131 (65%) had strict LBBB and 120 of 204 (59%) had traditional LBBB (P = 0.267). On multivariate analysis, a history of atrial fibrillation, larger LVESV, and the presence of mid-QRS notching in ≥1 lead (odds ratio 2.099; 95% confidence interval 1.061-4.152, P = 0.033) were independently associated with echocardiographic response. CONCLUSION: Stricter definition of LBBB did not improve response to CRT in comparison to the current AHA definition.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Eletrocardiografia , Idoso , Ecocardiografia , Feminino , Humanos , Masculino , Sistema de Registros , Resultado do Tratamento
16.
Europace ; 17(8): 1267-75, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25842271

RESUMO

AIMS: Internet-based remote interrogation systems have been shown to reduce emergency department and in-office visits in patients with implantable cardioverter defibrillators (ICDs), resulting in increased efficiency for healthcare providers. Nonetheless, studies sized to demonstrate the impact of remote monitoring on patients' outcome have been lacking. METHODS AND RESULTS: The EFFECT study was a multicentre clinical trial aimed at measuring and comparing the outcome of ICD patients conventionally followed-up by means of in-clinic visits (Standard arm) or by remote monitoring (Remote arm) in the clinical practice of 25 Italian centres. From 2011 to 2013, 987 consecutive patients were enrolled and followed up for at least 12 months. The primary endpoint was the rate of death and cardiovascular hospitalizations. Remote monitoring was adopted by 499 patients. Patients in the Standard and Remote arms did not differ significantly in terms of baseline clinical characteristics, except for a more frequent use of ICD with cardiac resynchronization therapy (CRT-D) in the Remote arm (48 vs. 36%, P < 0.001). One-year rates of the primary combined endpoint were 0.27 events/year for patients in the Standard arm and were 0.15 events/year for those in the Remote arm (incident rate ratio, 0.55; 95% CI, 0.41-0.73; P < 0.001). The endpoint rates in the Standard and Remote arms were 0.27 and 0.08 events/year, respectively, among CRT-D recipients (P < 0.001), and 0.28 vs. 0.21 among ICD patients (P = 0.094). The rates of in-office visits were 1.9 per year in the Standard arm and 1.7 per year in the Remote arm. CONCLUSION: Compared with the standard follow-up through in-office visits, remote monitoring is associated with reduced death and cardiovascular hospitalizations in patients with ICD in clinical practice. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/ Identifier: NCT01723865.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Telemedicina/estatística & dados numéricos , Idoso , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Itália/epidemiologia , Masculino , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
17.
Europace ; 16(3): 335-40, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24337158

RESUMO

AIMS: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicentre prospective study, we assessed the effect of direct contact force (CF) measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS AND RESULTS: A new open-irrigated tip catheter with CF sensing (SmartTouch™, Biosense Webster Inc.) was used. All the patients underwent the first ablation procedure for paroxysmal AF with antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. Ninety-five patients were enroled in nine centres and successfully underwent ablation. Overall procedure time, fluoroscopy time, and ablation time were 138.0 ± 67.0, 14.3 ± 11.2, and 33.8 ± 19.4 min, respectively. The mean CF value during ablation was 12.2 ± 3.9 g. Force time integral (FTI) analysis showed that patients achieving a value below the median of 543.0gs required longer procedural (158.0 ± 74.0 vs. 117.0 ± 52.0 min, P = 0.004) and fluoroscopy (17.5 ± 13.0 vs. 11.0 ± 7.7 min, P = 0.007) times as compared with those in whom FTI was above this value. Patients in whom the mean CF during ablation was >20 g required shorter procedural time (92.0 ± 23.0 vs. 160.0 ± 67.0 min, P = 0.01) as compared with patients in whom this value was <10 g. Four groin haematomas were the only complications observed. CONCLUSION: Contact force during RFCA for PV isolation affects procedural parameters, in particular procedural and fluoroscopy times, without increasing complications.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Fluoroscopia , Sistema de Condução Cardíaco/cirurgia , Duração da Cirurgia , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estresse Mecânico , Tato , Transdutores , Resultado do Tratamento , Adulto Jovem
18.
Europace ; 16(8): 1154-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25074972

RESUMO

AIMS: Despite catheter ablation (CA) has become an accepted treatment option for symptomatic, drug-resistant atrial fibrillation (AF), the safety of this procedure continues to be cause for concern. The aim of the present study was to assess the incidence of complications with permanent sequelae of CA for AF using open-irrigated catheters in a contemporary, unselected population of consecutive patients. METHODS AND RESULTS: From 1 January 2011 to 31 December 2011, data from 2167 consecutive patients who underwent CA for AF using an open-irrigated catheter in 29 Italian centres were collected. All the complications occurring to the patient from admission to the 30th post-procedural day were recorded. No procedure-related death was observed. Complications occurred in 81 patients (3.7%): 46 patients (2.1%) suffered vascular access complications; 13 patients (0.6%) cardiac tamponade, successfully drained in all the cases; six patients (0.3%) arterial thromboembolism (four transient ischaemic attack and two ischaemic strokes); five (0.2%) patients conservatively treated pericardial effusion; three patients (0.1%) phrenic nerve paralysis; three patients (0.1%) pericarditis; three patients (0.1%) haemothorax, and two patients (0.1%) other isolated adverse events. At multivariate analysis, only female sex [odds ratio (OR) 2.5, confidence interval (CI): 1.5-3.7, P < 001] and the operator experience (OR 0.5, CI: 0.4-0.7, P < 001) related to the complications. Only five (0.2%) patients developed permanent sequelae from their complications. CONCLUSION: Catheter ablation for AF with the use of open-irrigated catheters is currently affected by a very low rate of complications leading to permanent sequelae.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Complicações Pós-Operatórias/epidemiologia , Irrigação Terapêutica/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Humanos , Incidência , Itália/epidemiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
19.
Animals (Basel) ; 14(4)2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38396601

RESUMO

Peritoneopericardial diaphragmatic hernia (PPDH) is an opening between the pericardial sac and the pleuroperitoneal membrane. Pneumopericardium is an infrequent complication of PPDH. This condition is a serious circumstance in which free gas accumulates in the pericardial sac. The present report describes the occurrence of pneumopericardium and pericardial effusion after elective ovariectomy in a dog affected by PPDH. The presence of an umbilical and diaphragmatic hernia was highlighted during ovariectomy, and a pneumopericardium was seen during an X-ray exam. At the time of admission to the hospital, the dog was asymptomatic. The diagnosis was performed by X-ray and ultrasonographic exams. Computed tomography examination confirmed the diagnosis and directed for a surgical approach of the congenital defect. Surgery resulted in resolution of PPDH and of pneumopericardium.

20.
J Cardiovasc Electrophysiol ; 24(3): 269-73, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23210452

RESUMO

INTRODUCTION: Aim of this study was to compare efficacy and safety of the new ThermoCool Surround Flow® catheter (SFc) versus the ThermoCool® (TCc) in achieving persistent circumferential electrical isolation of the pulmonary veins (PVs) in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This multicenter, randomized, controlled study enrolled patients suffering from paroxysmal AF. Randomization was run in a one-to-one fashion between radiofrequency ablation by TCc or SFc. Aim of PVs ablation was documentation of electrical isolation with exit/entrance block recorded on a circular catheter. Among the 106 enrolled patients, 52 (49.0%) were randomized to TCc and 54 (51.0%) to SFc. Total volume of infused saline solution during the procedure was lower in the SFc than in TCc group (752.7 ± 268.6 mL vs 1,165.9 ± 436.2 mL, P < 0.0001). Number of identified and isolated PVs was similar in the 2 groups. Number of PVs remaining isolated 30 minutes after ablation was higher in the SFc than in TCc group (95.2% vs 90.5%, P < 0.03), mainly driven by acute ablation result in the left PVs (96.1% vs 89.7%, P < 0.04). Complications were seldom and observed only in the TCc group (0% vs 3.84%, P < 0.03). At 6-month follow-up SFc patients reported a trend toward less AF recurrences compared to those in the TCc group (22.9% vs 27.0%, P = 0.69). CONCLUSION: PV isolation by SFc lowered the rate of left PV early reconnections and reduced the volume of infused saline solution while maintaining the safety profile of AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Irrigação Terapêutica/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Cloreto de Sódio/administração & dosagem , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA