Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37748504

RESUMO

A subcommittee of the Netherlands Commission on Radiation Dosimetry (NCS) was initiated in 2018 with the task to update and extend a previous publication (NCS-15) on the quality assurance of treatment planning systems (TPS) (Bruinviset al2005). The field of treatment planning has changed considerably since 2005. Whereas the focus of the previous report was more on the technical aspects of the TPS, the scope of this report is broader with a focus on a department wide implementation of the TPS. New sections about education, automated planning, information technology (IT) and updates are therefore added. Although the scope is photon therapy, large parts of this report will also apply to all other treatment modalities. This paper is a condensed version of these guidelines; the full version of the report in English is freely available from the NCS website (http://radiationdosimetry.org/ncs/publications). The paper starts with the scope of this report in relation to earlier reports on this subject. Next, general aspects of the commissioning process are addressed, like e.g. project management, education, and safety. It then focusses more on technical aspects such as beam commissioning and patient modeling, dose representation, dose calculation and (automated) plan optimisation. The final chapters deal with IT-related subjects and scripting, and the process of updating or upgrading the TPS.

2.
Phys Med Biol ; 65(4): 045015, 2020 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-31365915

RESUMO

A new practical method to determine the ion recombination correction factor (k s ) for plane-parallel and Farmer-type cylindrical chambers in particle beams is investigated. Experimental data were acquired in passively scattered and scanned particle beams and compared with theoretical models developed by Boag and/or Jaffé. The new method, named the three-voltage linear method (3VL-method), is simple and consists of determining the saturation current using the current measured at three voltages in a linear region and dividing it by the current at the operating voltage (V) (even if it is not in the linear region) to obtain k s . For plane-parallel chambers, comparing k s -values obtained by model fits to values obtained using the 3VL-method, an excellent agreement is found. For cylindrical chambers, recombination is due to volume recombination only. At low voltages, volume recombination is too large and Boag's models are not applicable. However, for Farmer-type chambers (NE2571), using a smaller voltage range, limited down to 100 V, we observe a linear variation of k s with 1/V 2 or 1/V for continuous or pulsed beams, respectively. This linearity trend allows applying the 3VL-method to determine k s at any polarizing voltage. For the particle beams used, the 3VL-method gives an accurate determination of k s at any polarizing voltage. The choice of the three voltages must to be done with care to ensure to be in a linear region. For Roos-type or Markus-type chambers (i.e. chambers with an electrode spacing of 2 mm) and NE2571 chambers, the use of the 3VL-method with 300 V, 200 V and 150 V is adequate. A difference with the 2V-method and some 3V-methods in the literature is that in the 3VL-method the operational voltage does not have to be one of the three voltages. An advantage over a 2V-method is that the 3VL-method can inherently verify if the linearity condition is fulfilled.


Assuntos
Luz , Prótons , Radiometria/instrumentação , Modelos Lineares , Espalhamento de Radiação
3.
Phys Med ; 32(9): 1135-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27567088

RESUMO

This study was initiated following conclusions from earlier experimental work, performed in a low-energy carbon ion beam, indicating a significant LET dependence of the response of a PTW-60019 microDiamond detector. The purpose of this paper is to present a comparison between the response of the same PTW-60019 microDiamond detector and an IBA Roos-type ionization chamber as a function of depth in a 62MeV proton beam. Even though proton beams are considered as low linear energy transfer (LET) beams, the LET value increases slightly in the Bragg peak region. Contrary to the observations made in the carbon ion beam, in the 62MeV proton beam good agreement is found between both detectors in both the plateau and the distal edge region. No significant LET dependent response of the PTW-60019 microDiamond detector is observed consistent with other findings for proton beams in the literature, despite this particular detector exhibiting a substantial LET dependence in a carbon ion beam.


Assuntos
Radiometria/métodos , Algoritmos , Calibragem , Carbono/química , Diamante , Desenho de Equipamento , Íons , Transferência Linear de Energia , Prótons , Radiometria/instrumentação , Reprodutibilidade dos Testes
4.
Med Phys ; 43(7): 4198, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27370139

RESUMO

PURPOSE: In this work, ion recombination is studied as a function of energy and depth in carbon ion beams. METHODS: Measurements were performed in three different passively scattered carbon ion beams with energies of 62 MeV/n, 135 MeV/n, and 290 MeV/n using various types of plane-parallel ionization chambers. Experimental results were compared with two analytical models for initial recombination. One model is generally used for photon beams and the other model, developed by Jaffé, takes into account the ionization density along the ion track. An investigation was carried out to ascertain the effect on the ion recombination correction with varying ionization chamber orientation with respect to the direction of the ion tracks. The variation of the ion recombination correction factors as a function of depth was studied for a Markus ionization chamber in the 62 MeV/n nonmodulated carbon ion beam. This variation can be related to the depth distribution of linear energy transfer. RESULTS: Results show that the theory for photon beams is not applicable to carbon ion beams. On the other hand, by optimizing the value of the ionization density and the initial mean-square radius, good agreement is found between Jaffé's theory and the experimental results. As predicted by Jaffé's theory, the results confirm that ion recombination corrections strongly decrease with an increasing angle between the ion tracks and the electric field lines. For the Markus ionization chamber, the variation of the ion recombination correction factor with depth was modeled adequately by a sigmoid function, which is approximately constant in the plateau and strongly increasing in the Bragg peak region to values of up to 1.06. Except in the distal edge region, all experimental results are accurately described by Jaffé's theory. CONCLUSIONS: Experimental results confirm that ion recombination in the investigated carbon ion beams is dominated by initial recombination. Ion recombination corrections are found to be significant and cannot be neglected for reference dosimetry and for the determination of depth dose curves in carbon ion beams.


Assuntos
Carbono/uso terapêutico , Íons/uso terapêutico , Radioterapia/métodos , Algoritmos , Simulação por Computador , Ciclotrons , Modelos Teóricos , Método de Monte Carlo , Radioterapia/instrumentação , Síncrotrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA