Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Bioinformatics ; 40(2)2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38265243

RESUMO

MOTIVATION: BISCAP is a state-of-the-art tool for automatically characterizing biofilm images obtained from Optical Coherence Tomography. Limited availability of other software tools is reported in the field. BISCAP's first version processes 2D images only. Processing 3D images is a problem of greater scientific relevance since it deals with the entire structure of biofilms instead of their 2D slices. RESULTS: Building on the image-processing principles and algorithms proposed earlier for 2D images, these were adapted to the 3D case, and a more general implementation of BISCAP was developed. The primary goal concerns the extension of the initial methodology to incorporate the depth axis in 3D images; multiple improvements were also made to boost computational performance. The calculation of structural properties and visual outputs was extended to offer new insights into the 3D structure of biofilms. BISCAP was tested using 3D images of biofilms with different morphologies, consistently delivering accurate characterizations of 3D structures in a few minutes using standard laptop machines. Low user dependency is required for image analysis. AVAILABILITY AND IMPLEMENTATION: BISCAP is available from https://github.com/diogonarciso/BISCAP. All images used in the tutorials and the validation examples are available from https://web.fe.up.pt/∼fgm/biscap3d.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Software , Algoritmos , Biofilmes
2.
Ann Surg ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323417

RESUMO

OBJECTIVE: To analyze the outcomes of urgent/emergent endovascular aortic repair of patients with free/contained ruptured thoracoabdominal aortic aneurysms (rTAAA). BACKGROUND: Endovascular repair of rTAAA has been scarcely described in emergent setting. METHODS: An international multicenter retrospective observational study (ClinicalTrials.govID:NCT05956873) from January-2015 to January-2023 in 6 European and 1 United States Vascular Surgery Centers. Primary end-points were technical success, 30-day and/or in-hospital mortality and follow-up survival. RESULTS: A total of 100 rTAAA patients were included (75 male; mean age 73 y). All patients (86 contained and 14 free ruptures) were symptomatic and treated within 24-hours from diagnosis: multi-branched off-the-shelf devices (Zenith t-branch,Cook Medical Inc.Bjaeverskov,Denmark) in 88 patients, physician-modified endografts in 8, patient-specific device or parallel grafts in two patients each. Primary technical success was achieved in 89 patients and 30-day and/or in-hospital mortality was 24%. Major adverse events (MAEs) occurred in 34% of patients (permanent dialysis and paraplegia in 4 and 8 patients, respectively). No statistical differences were detected in mortality rates between free and contained ruptured patients (43%vs.21%; P =0.075). Multivariate analysis revealed contained rupture favoring technical success (Odd-Ratio10.1;95%Confidence-Interval:3.0-33.6; P =<0.001). MAEs (OR9.4;95%C-I:2.8-30.5; P =<0.001) and pulmonary complications (OR11.3;95%CI:3.0-41.5; P =<0.001) were independent risk factors for 30-day and/or in-hospital mortality. Median follow-up time was 13 months (interquartile range 5-24); 1-year survival rate was 65%. Aneurysm diameter>80 mm (Hazard-Ratio:2.0;95%CI:1.0-30.5; P =0.037), technical failure (HR:2.6;95%CI:1.1-6.5; P =0.045) and pulmonary complications (HR:3.0;95%CI:1.2-7.9; P =0.021) were independent risk factors for follow-up mortality. CONCLUSION: Endovascular repair of rTAAA shows high technical success; the presence of free rupture alone appear not to correlate with early mortality. Effective prevention/management of post-operative complications is crucial for survival.

3.
Ann Surg ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38647145

RESUMO

OBJECTIVE: With an increasing life expectancy, more octogenarian patients are referred with complex aortic aneurysms (cAAA). The aim of this study was to evaluate short and mid-term outcomes following fenestrated aortic repair (FEVAR) in octogenarians. SUMMARY BACKGROUND DATA: Few studies looking at octogenarian-specific outcomes with diverging results. METHODS: Retrospective, multicentre cohort study including consecutive patients undergoing elective FEVAR for cAAAs or type IV thoracoabdominal aortic aneurysms between 2007-2022 in eight high-volume centres. Octogenarians vs. non-octogenarians were compared. The primary outcome was 30-day mortality. Secondary outcomes included 1, 2 and 5-year survival and reintervention rates. RESULTS: A total of 729 patients (median age of 74.8 years [IQR 69.2 - 79.14]) were included, 169 (23%) of which were octogenarians, with 316 (43.3%) patients undergoing juxta/pararenal aneurysm repair. Although octogenarians presented less complex but larger (61 mm vs. 58 mm) aneurysms, the number of fenestrations was similar across groups. No differences in in-hospital mortality (4.1 vs. 3.0%), MAE (16.6% vs 12.2%) or reintervention rates (11.2 vs. 10%) were found. Multivariable logistic regression of in-hospital mortality identified BMI (OR 0.66, 95% CI 0.51-0.95, P=0.003), chronic heart failure (OR 7.70, 95% CI 1.36-36.15, P=0.003) and GFR<45 ml/min/1.73 m2 (OR 5.25, 95% CI 1.20-22.86, P=0.027) as independent predictors. Median follow-up was 41 months. The 1, 2 and 5-year survival rates were 91.3%, 81.8% and 49.5% in octogenarians vs 90.6%, 86.5% and 68.8% in non-octogenarian patients (Log-rank: =0.001). Freedom from aortic-related death and freedom from reintervention at five-years were similar across groups (log-rank=0.94 and .76, respectively). Age>80 was not an independent predictor of 30-day or long-term mortality on multivariable and Cox regression analysis. CONCLUSIONS: Elective FEVAR in octogenarians appears to be safe, with similar outcomes as in younger patients. Future studies looking at improved patient selection methods to ensure long-term survival benefits in both octogenarians and younger patients are warranted.

4.
J Vasc Surg ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39029810

RESUMO

INTRODUCTION: This study aimed to assess the impact of urgency on early and midterm outcomes of the Candy-Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair (TEVAR) for aortic dissection (AD). METHODS: The CP registry was reviewed, and patients were categorized into elective and urgent/emergent groups for analysis. Endpoints included technical success, clinical success, early (30-day) computed tomography angiography (CTA) findings, early (30-day) mortality, adverse events, aortic remodeling in patients with available CTA follow-up and re-intervention. RESULTS: A total of 155 patients received a custom-made Candy-Plug with 32 patients (44% males, mean age 61±9 years) were treated urgently vs. 123 patients (63% males, mean age 62±11 years) electively. The primary CP rate was higher in the urgent group; (28/32, (88%) in the urgent group vs. 96/123 (78%) in the elective group, p=051). The mean contrast volume was higher in the urgent group; (157±56ml in the urgent group vs. 130±71ml in the elective group, p=.017). Technical success was achieved in all patients in both groups. Clinical success was achieved in 25/32 (78%) patients in the urgent group vs. 113/123 (92%) in the elective group, p=.159. The early mortality rate was 4/32, (13%) patients in the urgent group vs. 1/123 (1%) in the elective group, p=.120). There was no statistically significant difference regarding the early adverse events between the urgent and elective CP groups. Early aortic-related re-interventions were required in 6/32 (19%) patients in the urgent group vs. 6/123 (5%) in the elective group, p=.094. Thoracic aortic aneurysm sac regression was lower in the urgent group (5/28, (18%) in the urgent group vs. 63/114 (55%) in the elective group, p=001). Stable thoracic aortic aneurysm sac was higher in the urgent group (22/28, (79%) in the urgent group vs. 47/114 (41%) in the elective group, p=000). An increase in thoracic aortic aneurysm sac occurred in 1/28 (4%) patient in the urgent group vs. 4/114 (4%) patients in the elective group, p=.096. CONCLUSION: The urgent use of the CP technique for distal FL occlusion in AD was feasible and effective. The decrease in aortic FL sac diameter may be affected by the urgent use of CP due to limited sizing availability. However, it achieved high rate of aortic remodeling.

5.
J Vasc Surg ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38992807

RESUMO

OBJECTIVE: To report outcomes of urgent juxta/para-renal aneurysms (J/P-AAAs) managed by off-the-shelf multibranched thoracoabdominal endografts (Cook, T-branch). METHODS: In this observational, multicenter, retrospective study, patients with J/P-AAAs treated by urgent endovascular repair by T-branch in 23 European aortic centers, from 2013 to 2023, were analyzed. Contained J/P-AAAs rupture, presence of related symptoms, and aneurysm diameter >70mm were considered as indication for urgent repair. Technical success (TS), spinal cord ischemia (SCI) and 30-day/hospital mortality were assessed as early outcomes. Survival, freedom from (FF) reinterventions and target arteries instability (TAI) were evaluated during follow-up. RESULTS: Overall, 197 patients [J-AAAs:64(33%), P-AAAs:95(48%), previous failed-EVAR 38(19%)] were analyzed. The mean age and aneurysm diameter was 75+8 years and 76+4 mm, respectively. The ASA score was 3 and 4 in 118(60%) and 79(40%) patients. Rupture, symptoms and diameter >70mm were present in 51(26%), 110(56%) and 53(27%) patients, respectively. An adjunctive proximal thoracic endograft was used in 28(14%) cases. The mean aortic coverage between the upper portion of the endograft and the lowest renal artery was 154+49mm. Single-stage repair and cerebral-spinal-fluid drainage were reported in 144(73%) and 53(27%) cases, respectively. TS was achieved in 182(92%) cases (rupture:84% vs no rupture:95%; P:.02). Failures consist of target artery loss (11-6%: renal artery - 9; celiac trunk - 2), type I-III endoleak (2-1%) and 24-h mortality (2-1%). Rupture was a risk-factor for technical failure (P:.02;OR:3.8;95%CI:1.1-12.1). Overall, 15(8%) patients had persistent SCI (rupture:14% vs no rupture:5%) with 11(6%) cases of paraplegia (rupture:10% vs no rupture:5%; P:.001). Rupture (P:.04;OR:3.1;95%CI:1.1-8.9) and adjunctive proximal thoracic endograft (P:.01;OR:4.1;95%CI:1.3-12.9) were risk-factors for SCI. Twenty-two (11%) patients died within 30-day or during a prolonged hospitalization. Previous failed-EVAR (P:.04;OR:3.6;95%CI:1.1-12.3), paraplegia (P:<.001;OR:9.9;95%CI:1.6-62.2), postoperative mesenteric complications (P:.03;OR:10.4;95%CI:1.2-93.3) as well as cardiac (P:.03;OR:8.2;95%CI:2.0-33.0) and respiratory (P:<.001;OR:10.1;95%CI:2.9-35.2) morbidities were associated with 30-day/hospital mortality. The mean follow-up was 19+5months. Estimated 3-year survival and FF-reinterventions was 58% and 77%, respectively. TAI occurred in 27(14%) patients (occlusion:15, endoleak:14) with an estimated 3-year FF-TAI of 72%. CONCLUSIONS: Urgent repair of J/P-AAAs by T-branchis feasible and effective with satisfactory TS and 30-day/hospital mortality in high-risk patients. However, extensive aortic coverage is necessary, leading to a not negligible SCI rate, especially in case of aortic rupture or when adjunctive thoracic endografts are necessary. Previous failed-EVAR, postoperative mesenteric complications as well as cardiac and respiratory morbidities were associated with 30-day/hospital mortality and they should be subjected to more research for the purpose of improving outcomes.

6.
J Endovasc Ther ; : 15266028241266218, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39082418

RESUMO

PURPOSE: To describe a novel technique for optimal orientation and accurate deployment of aortic endografts during complex endovascular aortic repair (cEVAR). TECHNIQUE: After establishing the femoral access in the standard fashion, a long large-bore dilator is inserted before the cEVAR delivery system. The dilator is advanced beyond the renovisceral segment noticing the degree of axial rotation. The endograft markers are verified with fluoroscopy outside the patient in the standard way. Thereafter, the cEVAR delivery system is pre-emptively rotated by the same degree in the opposite direction than the dilator showed upon insertion. The endograft is then advanced into position with the markers ending with the markers roughly in position. Minor adjustments are done before and during deployment if needed as per standard technique. CONCLUSION: The use of long, large-bore dilator before the introduction of the aortic graft allows to proactively minimize the risk of endograft misalignment and malrotation especially in cases with challenging anatomies in both the visceral and iliac segments. This can potentially be used in all cases because it minimizes the manipulation of the delivery system and potentially increases the accuracy of endograft deployment. CLINICAL IMPACT: This report describes a novel technique involving the use of a long large-bore dilator to predict the degree of rotation of the cEVAR delivery system during insertion and thereby enabling a pre-emptive compensation. This facilitates the precise orientation of the main aortic endograft with an easier alignment of any branches and/or fenestrations to their respective target arteries. This approach holds the potential to mitigate several of the difficulties commonly encountered with current cEVAR solutions, especially the challenges posed by small and tortuous access and severe angulation in the iliac and visceral aortic segment.

7.
J Endovasc Ther ; : 15266028241257090, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807416

RESUMO

PURPOSE: This study aimed to assess the feasibility and short-term outcomes of different manufactured proximal and distal stent graft components during fenestrated endovascular aortic repair (FEVAR). MATERIALS AND METHODS: A multicenter retrospective review was conducted at 3 aortic centers, involving all consecutive patients who underwent FEVAR utilizing a customized Dacron-based tubular proximal and a distal bifurcated polytetrafluoreten (PTFE)-based commercially available stent grafts. Primary outcomes were 30 day mortality, major adverse events, and technical and clinical success. Secondary outcomes assessed stent graft migration, occurrence of types I/III endoleak, and reintervention. RESULTS: A total of 23 FEVAR cases across all centers were included in this study. Technical success was achieved in all cases, with a median procedure time of 183 (153-244) minutes. There were no major adverse events, except for 1 transient acute renal failure. The median follow-up period was 23 (17-28) months. All target vessels retained patent with the exception of 1 right renal fenestration that showed signs of kinking at the first follow-up, and despite secondary intervention with relining and distal extension, there was an occlusion afterward and 1 hepatic artery with a separate fenestration. This and 1 successful relining of a superior mesenteric artery kink were the only reinterventions in this cohort. One case of persistent type 1b endoleak was reported in a patient with chronic type B aortic dissection, which resolved with distal extension on the external iliac artery 5 months after the index procedure. No deaths occurred throughout the follow-up with, and there were no signs of stent graft migration or type 3 endoleak. CONCLUSION: The use of commercially available PTFE-based bifurcated stent grafts to extend distally the tubular graft appears to be a feasible approach during FEVAR, with promising short-term outcomes. Further studies are necessary to define the applicability of this solution and evaluate long-term outcomes. CLINICAL IMPACT: This multicentric study on fenestrated endovascular aortic repair (FEVAR) demonstrates the feasibility and good short-term outcomes of utilizing a PTFE-based commercially available stent graft to extend the proximal tubular custom-made fenestrated stent graft. The high technical success rate, absence of major adverse events, and low occurrence of complications such as stent graft migration and endoleaks highlight the potential clinical benefits of this approach with an off-the-shelf distal extension whose delivery system does not cross the fenestrations intraoperatively.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38876370

RESUMO

OBJECTIVE: To compare and evaluate early and midterm outcomes of a novel no cross approach with short tip vs. standard tip introducer systems for all distal components to prevent target vessel bridging stent kink or collapse during fenestrated endovascular aortic repair (FEVAR). METHODS: A retrospective analysis was conducted on all patients who underwent FEVAR at a tertiary referral centre between October 2016 and July 2022. The inclusion criterion was the use of renal artery fenestrations. Patients who had chronic dissections were included. Endpoints were analysed in two groups comprising the no cross group and the standard group, with all cases being consecutive in their respective groups. Cone beam computed tomography was used intra-operatively in all cases, and post-operative computed tomography angiograms and re-interventions were reviewed. Primary endpoints included technical success, intra-operative adjunctive procedures, adverse events related to the fenestration, and re-interventions, while secondary endpoints were secondary interventions and overall mortality rate. RESULTS: Seventy patients (35 in each group) were enrolled in the study, with 64 (91%) having juxtarenal aneurysms. There were no differences in demographics, cardiovascular risk factors, or aneurysm characteristics between the two groups. The no cross group demonstrated a significantly higher technical success rate (100% in all cases) compared with the standard group (29 cases, 83%; p = .010). Additionally, there were statistically significantly fewer intra-operative adjunctive procedures required in the no cross group (1.5% of fenestrations) compared with the standard group (8.2% of fenestrations) (p = .013). The overall median follow up was 32 months (interquartile range 22, 62 months). CONCLUSION: Implementation of a novel no cross concept during FEVAR, using a short dilator introducer tip on the distal bifurcated component and iliac extensions, significantly reduced intra-operative fenestration related adverse events and enhanced technical success. Further studies with larger patient populations and longer follow up are needed to confirm these findings.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38705454

RESUMO

OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.

10.
Eur J Vasc Endovasc Surg ; 67(2): 192-331, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38307694

RESUMO

OBJECTIVE: The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS: The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS: A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION: The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.

11.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38818846

RESUMO

AIMS: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. METHODS AND RESULTS: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the 'Multipolar group', where a dedicated high-density mapping catheter was employed, and the 'PbP group', where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41-65) years]-248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217-843) vs. 95 (42-185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476-5.108), P = 0.02]. CONCLUSION: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas
12.
Ann Surg ; 278(2): e389-e395, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35837956

RESUMO

OBJECTIVE: To report the mid-term outcomes of fenestrated-branched endovascular aneurysm repair (F-BEVAR) following a failed previous endovascular aneurysm repair (pEVAR) or previous open aneurysm repair (pOAR). METHODS: Data from consecutive patients who underwent F-BEVAR for pEVAR or pOAR from 2006 to 2021 from 17 European vascular centers were analyzed. Endpoints included technical success, major adverse events, 30-day mortality, and 5-year estimates of survival, target vessel primary patency, freedom from reinterventions, type I/III endoleaks, and sac growth >5 mm. BACKGROUND: Treatment of a failed previous abdominal aortic aneurysm repair is a complex undertaking. F-BEVAR is becoming an increasingly attractive option, although comparative data are limited regarding associated risk factors, indications for treatment, and various outcomes. RESULTS: There were 526 patients included, 268 pOAR and 258 pEVAR. The median time from previous repair to F-BEVAR was 7 (interquartile range, 4-12) years, 5 (3-8) for pEVAR, and 10 (6-14) for pOAR, P <0.001. Predominant indication for treatment was type Ia endoleak for pEVAR and progression of the disease for pOAR. Technical success was 92.8%, pOAR (92.2%), and pEVAR (93.4%), P =0.58. The 30-day mortality was 6.5% overall, 6.7% for pOAR, and 6.2% for pEVAR, P =0.81. There were 1853 treated target vessels with 5-year estimates of primary patency of 94.4%, pEVAR (95.2%), and pOAR (94.4%), P =0.03. Five-year estimates for freedom from type I/III endoleaks were similar between groups; freedom from reintervention was lower for pEVAR (38.3%) than for pOAR (56.0%), P =0.004. The most common indication for reinterventions was for type I/III endoleaks (37.5%). CONCLUSIONS: Repair of a failed pEVAR or pOARis safe and feasible with comparable technical success and survival rates. While successful treatment can be achieved, significant rates of reintervention should be anticipated, particularly for issues related to instability of target vessels/bridging stents.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Endoleak/epidemiologia , Endoleak/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Fatores de Risco , Sistema de Registros , Estudos Retrospectivos , Desenho de Prótese
13.
Ann Surg ; 278(4): 568-577, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37395613

RESUMO

OBJECTIVE: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS: A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Estudos Retrospectivos , Prótese Vascular
14.
Bioinformatics ; 38(6): 1708-1715, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-34986264

RESUMO

MOTIVATION: Processing of Optical Coherence Tomography (OCT) biofilm images is currently restricted to a set of custom-made MATLAB scripts. None of the tools currently available for biofilm image processing (including those developed for Confocal Laser Scanning Microscopy-CLSM) enable a fully automatic processing of 2D OCT images. RESULTS: A novel software tool entitled Biofilm Imaging and Structure Classification Automatic Processor (BISCAP) is presented. It was developed specifically for the automatic processing of 2D OCT biofilm images. The proposed approach makes use of some of the key principles used in CLSM image processing, and introduces a novel thresholding algorithm and substratum detection strategy. Two complementary pixel continuity checks are executed, enabling very detailed pixel characterizations. BISCAP delivers common structural biofilm parameters and a set of processed images for biofilm analysis. A novel biofilm 'compaction parameter' is suggested. The proposed strategy was tested on a set of 300 images with highly satisfactory results obtained. BISCAP is a Python-based standalone application, not requiring any programming knowledge or property licenses, and where all operations are managed via an intuitive Graphical User Interface. The automatic nature of this image processing strategy decreases biasing problems associated to human-perception and allows a reliable comparison of outputs. AVAILABILITY AND IMPLEMENTATION: BISCAP and a collection of biofilm images obtained from OCT scans can be found at: https://github.com/diogonarciso/BISCAP. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal/métodos , Software , Biofilmes
15.
J Cardiovasc Electrophysiol ; 34(2): 356-365, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36434798

RESUMO

INTRODUCTION: Critical isthmuses of atypical atrial flutters (AAFLs) are usually located at slow conduction areas that exhibit fractionated electrograms. We tested a novel software, intended for integration with a commercially available navigation system, that automatically detects fractionated electrograms, to identify the critical isthmus in patients with AAFL ablation. METHODS AND RESULTS: All available patients were analyzed; 27 patients with 33 AAFLs were included. The PentaRay NAV catheter (Biosense Webster) was used for mapping. The novel software was retrospectively applied; fractionated points with duration ≥80 ms and bipolar voltage between 0.05 and 0.5 mV were highlighted on the surface of maps. In 10 randomly chosen AAFLs, an expert electrophysiologist evaluated the positive predictive value of the algorithm to detect true fractionation: 74.4%. We tested the capacity of the software to identify areas of fractionation (defined as clusters of ≥3 adjacent points with fractionation) at the critical isthmus of the AAFLs (defined using conventional mapping criteria). An area of fractionation was identified at the critical isthmus in 30 cases (91%). Globally, 144 areas of fractionation (median number per AAFL 4 [3-6]) were identified. Duration of the fractionation or the surface of the areas was not different between areas at critical isthmuses and the rest. Setting the fractionation score filter of the software in nine provided best performance. CONCLUSIONS: The novel software detected areas of fractionation at the critical isthmus in most AAFLs, which may help identify the critical isthmus in clinical practice.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Estudos Retrospectivos , Ablação por Cateter/métodos , Frequência Cardíaca , Valor Preditivo dos Testes
16.
J Cardiovasc Electrophysiol ; 34(2): 389-399, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36335623

RESUMO

INTRODUCTION: Scar-related ventricular tachycardia (VT) usually results from an underlying reentrant circuit facilitated by anatomical and functional barriers. The later are sensitive to the direction of ventricular activation wavefronts. We aim to evaluate the impact of different ventricular activation wavefronts on the functional electrophysiological properties of myocardial tissue. METHODS: Patients with ischemic heart disease referred for VT ablation underwent high-density mapping using Carto®3 (Biosense Webster). Maps were generated during sinus rhythm, right and left ventricular pacing, and analyzed using a new late potential map software, which allows to assess local conduction velocities and facilitates the delineation of intra-scar conduction corridors (ISCC); and for all stable VTs. RESULTS: In 16 patients, 31 high-resolution substrate maps from different ventricular activation wavefronts and 7 VT activation maps were obtained. Local abnormal ventricular activities (LAVAs) were found in VT isthmus, but also in noncritical areas. The VT isthmus was localized in areas of LAVAs overlapping surface between the different activation wavefronts. The deceleration zone location differed depending on activation wavefronts. Sixty-six percent of ISCCs were similarly identified in all activating wavefronts, but the one acting as VT isthmus was simultaneously identified in all activation wavefronts in all cases. CONCLUSION: Functional based substrate mapping may improve the specificity to localize the most arrhythmogenic regions within the scar, making the use of different activation wavefronts unnecessary in most cases.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/diagnóstico , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
J Vasc Surg ; 77(5): 1405-1412.e1, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36646335

RESUMO

OBJECTIVES: Carbon dioxide (CO2) angiography for endovascular aortic repair (CO2-EVAR) is used to treat abdominal aortic aneurysms (AAAs), especially in patients with chronic kidney disease or allergy to iodinated contrast medium (ICM). However, some technical issues regarding the visualization of the lowest renal artery (LoRA) and the best quality image through angiographies performed from pigtail or introducer sheath are still unsolved. The aim of this study was to analyze different steps of CO2-EVAR to create an operative standardized protocol. METHODS: Patients undergoing CO2-EVAR were prospectively enrolled in five European centers from 2019 to 2021. CO2-EVAR was performed using an automated injector (pressure, 600 mmHg; volume, 100 cc); a small amount of ICM was injected in case of difficulty in LoRA visualization. LoRA visualization and image quality (1 = low, 2 = sufficient, 3 = good, 4 = excellent) were analyzed at different procedure steps: preoperative CO2 angiography from pigtail and femoral introducer sheath (first step), angiographies from pigtail at 0%, 50%, and 100% of proximal main body deployment (second step), contralateral hypogastric artery (CHA) visualization with CO2 injection from femoral introducer sheath (third step), and completion angiogram from pigtail and femoral introducer sheath (fourth step). Intraoperative and postoperative CO2-related adverse events were also evaluated. χ2 and Wilcoxon tests were used for statistical analysis. RESULTS: In the considered period, 65 patients undergoing CO2-EVAR were enrolled (55/65 [84.5%] male; median age, 75 years [interquartile range (IQR), 11.5 years]). The median ICM injected was 17 cc (IQR, 51 cc); 19 (29.2%) of 65 procedures were performed with 0 cc ICM. Fifty-five (84.2%) of 65 patients underwent general anesthesia. In the first step, median image quality was significantly higher with CO2 injected from femoral introducer (pigtail, 2 [IQR, 3] vs introducer, 3 [IQR, 3]; P = .008). In the second step, LoRA was more frequently detected at 50% (93% vs 73.2%; P = .002) and 100% (94.1% vs 78.4%; P = .01) of proximal main body deployment compared with first angiography from pigtail; similarly, image quality was significantly higher at 50% (3 [IQR, 3] vs 2 [IQR, 3]; P ≤ .001) and 100% (4 [IQR, 3] vs 2 [IQR, 3]; P = .001) of proximal main body deployment. CHA was detected in 93% cases (third step). The mean image quality was significantly higher when final angiogram (fourth step) was performed from introducer (pigtail, 2.6 ± 1.1 vs introducer, 3.1 ± 0.9; P ≤ .001). The intraoperative (7.7%) and postoperative (12.5%) adverse events (pain, vomiting, diarrhea) were all transient and clinically mild. CONCLUSIONS: Preimplant CO2 angiography should be performed from femoral introducer sheath. Gas flow impediment created by proximal main body deployment can improve image quality and LoRA visualization with CO2. CHA can be satisfactorily visualized with CO2 alone. Completion CO2 angiogram should be performed from femoral introducer sheath. This operative protocol allows performance of CO2-EVAR with 0 cc or minimal ICM, with a low rate of mild temporary complications.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Aortografia/métodos , Dióxido de Carbono/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Estudos Prospectivos , Procedimentos Endovasculares/efeitos adversos , Meios de Contraste/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Resultado do Tratamento , Estudos Retrospectivos , Estudos Multicêntricos como Assunto
18.
J Vasc Surg ; 78(4): 863-873.e3, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37330705

RESUMO

OBJECTIVE: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. METHODS: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. RESULTS: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. CONCLUSIONS: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Prótese Vascular , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Fatores de Tempo , Desenho de Prótese
19.
J Vasc Surg ; 78(4): 854-862.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37321524

RESUMO

OBJECTIVE: This multicenter international study aimed to describe outcomes of fenestrated-branched endovascular aortic repairs (FB-EVAR) in a cohort of patients treated for chronic post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs). METHODS: We reviewed the clinical data of all consecutive patients treated by FB-EVAR for repair of extent I to III PD-TAAAs in 16 centers from the United States and Europe (2008-2021). Data were extracted from institutional prospectively maintained databases and electronic patient records. All patients received off-the-shelf or patient-specific manufactured fenestrated-branched stent grafts. Endpoints were any cause mortality and major adverse events at 30 days, technical success, target artery (TA) patency, freedom from TA instability, minor (endovascular with <12 Fr sheath) and major (open or ≥12 Fr sheath) secondary interventions, patient survival, and freedom from aortic-related mortality (ARM). RESULTS: A total of 246 patients (76% male; median age, 67 years [interquartile range, 61-73 years]) were treated for extent I (7%), extent II (55%), and extent III (35%) PD-TAAAs by FB-EVAR. The median aneurysm diameter was 65 mm (interquartile range, 59-73 mm). Eighteen patients (7%) were octogenarians, 212 (86%) were American Society of Anesthesiologists class ≥3, and 21 (9%) presented with contained ruptured or symptomatic aneurysms. There were 917 renal-mesenteric vessels targeted by 581 fenestrations (63%) and 336 directional branches (37%), with a mean of 3.7 vessels per patient. Technical success was 96%. Mortality and rate of major adverse events at 30 days was 3% and 28%, including disabling complications such as new onset dialysis in 1%, major stroke in 1%, and permanent paraplegia in 2%. Mean follow-up was 24 months. Kaplan-Meier (KM) estimated patient survival at 3 and 5 years was 79% ± 6% and 65% ± 10%. KM estimated freedom from ARM was 95% ± 3% and 93% ± 5% at the same intervals. Unplanned secondary interventions were needed in 94 patients (38%), including minor procedures in 64 (25%) and major procedures in 30 (12%). There was one conversion to open surgical repair (<1%). KM estimated freedom from any secondary intervention was 44% ± 9% at 5 years. KM estimated primary and secondary TA patency were 93% ± 2% and 96% ± 1% at 5 years, respectively. CONCLUSIONS: FB-EVAR for chronic PD-TAAAs was associated with high technical success and a low rate of mortality (3%) and disabling complications at 30 days. Although the procedure is effective in the prevention of ARM, patient survival was low at 5 years (65%), likely due to the significant comorbidities in this cohort of patients. Freedom from secondary interventions at 5 years was 44%, although most procedures were minor. The significant rate of reinterventions highlights the need for continued patient surveillance.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
20.
J Vasc Surg ; 77(6): 1588-1597.e4, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36731757

RESUMO

OBJECTIVE: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. RESULTS: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. CONCLUSIONS: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.


Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Prótese Vascular , Aneurisma/cirurgia , Estudos Retrospectivos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA