Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Forensic Sci Int Genet ; 43: 102142, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31437782

RESUMO

Small variations between haplotypes detected in different tissues from the same individual have been previously described. These differences complicate the interpretation of mtDNA results in real forensic casework. mtDNA haplotypes detected in hair strands collected at the crime scene have to be frequently compared with haplotypes of reference samples (buccal swabs) from victims or suspects. Nucleotide position 16093 is a well-known hot spot where differences can accumulate between different tissues of the same individual. Intra individual variation was also detected at positions 16182 and 16183 in haplotypes showing an uninterrupted HV1 poly-C stretch (with 16189C). In order to better characterize the type of variation in these positions between buccal cells and hair strands from the same individual, we have performed Sanger sequencing in 25-28 hair strands (411 in total) from 15 individuals showing either an uninterrupted HV1 polyC-stretch (16189C) or 16093C/Y in their buccal cells. The results have been evaluated by also taking into account our previous results published in [19]. We have found that no variation among hair strands was detected in individuals showing T16093 in buccal cells, while variation in hair strands (T16093, 16093C and 16093Y) were detected in individuals showing 16093C or 16093Y in buccal cells. Regarding nucleotide positions 16182 and 16183 in combination with an uninterrupted polyC-stretch, no variation was detected in hairs from individuals showing A16182 16183C in their buccal cells. In contrast, individuals A16182 A16183 showed hair strands with A16182 16183 M and A16182 16183C. And finally, individuals with 16182C 16183C showed some variation in a small amount of their hair strands (some hairs with 16182 M 16183C). These results can be relevant for forensic practitioners when comparing reference samples with hair strands, which is the type of sample most tested by using mtDNA analysis in forensic casework.


Assuntos
DNA Mitocondrial/genética , Cabelo/química , Polimorfismo Genético , Análise de Sequência de DNA , Sequência de Bases , Células Epiteliais/química , Humanos , Mucosa Bucal/citologia , Reação em Cadeia da Polimerase
2.
Forensic Sci Int Genet ; 25: 1-9, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27484846

RESUMO

Hairs from the same donor have been found to differ in mtDNA sequence within and among themselves and from other tissues, which impacts interpretation of results obtained in a forensic setting. However, little is known on the magnitude of this phenomenon and published data on systematic studies are scarce. We addressed this issue by generating mtDNA control region (CR) profiles of >450 hair fragments from 21 donors by Sanger-type sequencing (STS). To mirror forensic scenarios, we compared hair haplotypes from the same donors to each other, to the corresponding buccal swab reference haplotypes and analyzed several fragments of individual hairs. We also investigated the effects of hair color, donor sex and age, mtDNA haplogroup and chemical treatment on mtDNA quantity, amplification success and variation. We observed a wide range of individual CR sequence variation. The reference haplotype was the only or most common (≥75%) hair haplotype for most donors. However, in two individuals, the reference haplotype was only found in about a third of the investigated hairs, mainly due to differences at highly variable positions. Similarly, most hairs revealed the reference haplotype along their entire length, however, about a fifth of the hairs contained up to 71% of segments with deviant haplotypes, independent of the longitudinal position. Variation affected numerous positions, typically restricted to the individual hair and in most cases heteroplasmic, but also fixed (i.e. homoplasmic) substitutions were observed. While existing forensic mtDNA interpretation guidelines were found still sufficient for all comparisons to reference haplotypes, some comparisons between hairs from the same donor could yield false exclusions when those guidelines are strictly followed. This study pinpoints the special care required when interpreting mtDNA results from hair in forensic casework.


Assuntos
DNA Mitocondrial/genética , Variação Genética , Cabelo/química , Análise de Sequência de DNA , Adulto , Feminino , Genética Forense , Haplótipos , Humanos , Reação em Cadeia da Polimerase , Adulto Jovem
3.
Forensic Sci Int ; 247: 126-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25575014

RESUMO

Hexagon Obti immunological blood test and flocked swab are widely used in forensic laboratories. Nevertheless, up to now, no compatibility tests have been published between sampling with the ethylene oxide treated flocked swab and the Hexagon Obti blood detection strip. In this study, we investigated this compatibility. Our work shows that sampling with ethylene oxide treated flocked swab reduces by a factor of at least 100 the detection threshold of blood using the Hexagon Obti immunological test.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Manchas de Sangue , Óxido de Etileno , Nylons , Fitas Reagentes , Medicina Legal/instrumentação , Humanos , Testes Imunológicos/instrumentação , Masculino , Antígeno Prostático Específico/isolamento & purificação , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA