Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Perfusion ; : 2676591241241422, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38537032

RESUMO

PURPOSE: To investigate the impact of direct aortic cannulation (DAC) versus femoral arterial cannulation (FAC) on clinical outcomes of surgery for acute type A aortic dissection. METHODS: PubMed/MEDLINE, Scopus, and Cochrane Central Register of Controlled Trials were searched until August 25, 2023, to conduct a meta-analysis. Primary endpoints of the study were operative mortality and postoperative stroke. Secondary endpoints were cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, temporary neurological dysfunction (TND), combined stroke and TND, re-exploration for bleeding, and need for renal replacement therapy. A random-effect model was used to estimate the pooled effect size, and a leave-one-out method was used for the primary endpoints for sensitivity analysis. RESULTS: 15 studies met our eligibility criteria, including a total of 7941 samples. Operative mortality was significantly lower in the DAC group with a pooled odds ratio (OR) of 0.72 [95% confidence interval (CI): 0.61-0.85)]. Incidence of postoperative stroke was also lower in the DAC group with a pooled OR of 0.79 (95% CI: 0.66-0.94). However, after excluding one study with the greatest weight, the difference became nonsignificant. DAC was also associated with a lower incidence of postoperative TND, and re-exploration for bleeding with a pooled OR of 0.52 (95% CI: 0.37-0.73), and 0.60 (95% CI: 0.47-0.77), respectively. CONCLUSIONS: This meta-analysis showed that patients who underwent ATAAD repair with DAC had a lower incidence of operative mortality, postoperative stroke, TND, and re-exploration for bleeding compared to those who underwent FAC.

2.
Catheter Cardiovasc Interv ; 101(3): 639-650, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36655511

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve implantation (TAVI). The cusp-overlap view (COV) was adopted to reduce PPI risk after TAVI with self-expandable valves (SEVs); however, the evidence remains scarce. We performed a systematic review with meta-analysis comparing COV and the standard coplanar view (CPV) technique to evaluate their effectiveness and safety. METHODS: Following the PRISMA statement, data were extracted from studies published by August 2022 and found in PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, and Google Scholar. The primary outcome of interest was post-procedural PPI and the secondary outcomes were new left bundle branch block (LBBB), moderate/severe paravalvular leak (PVL), valve dislocation (pop-out); need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, implantation depth (mm), and post-TAVI mean gradients (mmHg). RESULTS: Eleven studies met our eligibility criteria and included 1464 patients in the COV group and 1743 patients in the CPV group. Patients who underwent TAVI with COV had lower risk of PPI (odds ratio 0.48; 95% confidence interval [CI] 0.33-0.70; p = 0.001) and higher implantation depths with COV (mean difference -0.83; 95% CI -1.2 to -0.45; p < 0.001). We did not observe any statistically significant differences in the rates of new LBBB, moderate/severe PVL, valve dislocation, need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, and post-TAVI mean gradients (mmHg). CONCLUSION: In TAVI with SEVs, the application of COV is associated with lower risk of PPI compared with the standard CPV without increasing risk for adverse outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Arritmias Cardíacas/etiologia , Bloqueio de Ramo/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
3.
Heart Fail Rev ; 27(4): 1247-1260, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33829389

RESUMO

Thanks to the improvement in mitral regurgitation (MR) diagnostic and therapeutic management, with the introduction of minimally invasive techniques which have considerably reduced the individual surgical risk, the optimization of the timing for MR "open" or percutaneous surgical treatment has become a main concern which has highly raised scientific interest. In fact, the current indications for intervention in MR, especially in asymptomatic patients, rely on echocardiographic criteria with high severity cut-offs that are fulfilled only when not only mitral valve apparatus but also the cardiac chambers' structure and function are severely impaired, which results in poor benefits for post-operative clinical outcome. This led to the need of new indices to redefine the optimal surgical timing in these patients. Speckle tracking echocardiography provides early markers of cardiac dysfunction due to subtle myocardial impairment; therefore, it could offer pivotal information in this setting. In fact, left ventricular and left atrial strains have already shown evidence about their usefulness in recognizing MR impact not only on symptoms and quality of life but also on cardiovascular events and new-onset atrial fibrillation in these patients. Moreover, right ventricular strain could be used to identify those patients with advanced cardiac damage and different grades of right ventricular dysfunction, which entails higher risks for cardiac surgery that could overweigh surgical benefits. This review aims to describe the importance of reconsidering the timing of intervention in MR and to analyze the potential additive value of speckle tracking echocardiography in this clinical setting.


Assuntos
Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Ecocardiografia/métodos , Ventrículos do Coração , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida
4.
Catheter Cardiovasc Interv ; 99(6): 1886-1896, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312216

RESUMO

Sutureless/rapid-deployment (SURD) valves are options different from the stented prostheses included in the pivotal trials comparing surgical aortic valve replacement (AVR) and transcatheter aortic valve implantation (TAVI). We performed a meta-analysis with reconstructed time-to-event data of matched studies published by November 2021 to compare SURD-AVR and TAVI. Primary endpoints were 30-day mortality and overall survival in the follow-up. Secondary endpoints included: 30-day stroke, acute kidney injury (AKI), major bleeding, permanent pacemaker implantation (PPI), paravalvular leak (PVL), prosthesis-patient mismatch (PPM), postoperative aortic valve area (AVA), and mean gradients. Ten studies met our eligibility criteria, including a total of 5134 patients (2567 underwent SURD-AVR and 2567 underwent TAVI). Pooled risk of 30-day mortality did not favor any group (odds ratio [OR]: 0.69; 95% confidence interval [CI]: 0.31-1.53; p = 0.360). Patients undergoing SURD-AVR had lower risk of PVL (OR: 0.09; 95% CI: 0.05-0.17; p < 0.001). No statistically significant differences were observed for 30-day stroke, AKI, major bleeding, PPI, PPM, and postoperative AVA. In the follow-up, we observed a higher risk of mortality (hazard ratio: 1.74; 95% CI: 1.26-2.40; p < 0.001) with TAVI. Patients who underwent SURD-AVR experienced better survival, however, the interpretation of these results warrant caution due to the fact that SURD-AVR patients tended to be younger than TAVI patients. Structural heart surgeons and interventional cardiologists should consider initial risk and life expectancy when referring patients for one approach over the other.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
J Card Surg ; 37(12): 5599-5602, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378875

RESUMO

INTRODUCTION: Robotic-assisted coronary artery bypass grafting (CABG) outcomes in patients with a high society of thoracic surgery (STS) score in urgent settings remain hindered. PRESENTATION OF CASE: A high-risk female patient presented with dyspnea and low ejection fraction (EF = 15%) and was diagnosed with pulmonary edema post myocardial infarction. She was medically stabilized with intraaortic balloon pump and the heart-team decided to intervene with off-pump robotic hybrid coronary revascularization (HCR). The patient had the planned with left internal mammary artery (LITA) anastomosis to the left anterior descending artery (LAD) and the postoperative recovery was uneventful and patients discharged after few days at home. DISCUSSION: CABG has proven to be superior to percutaneous coronary intervention (PCI) even when guided by fractional flow rate and using the last generation stents according to fractional flow reserve versus angiography for multivessel evaluation 3 clinical trial. In moderate SYNTAX score patients that have been historically (SYNTAX trial) treated with multivessels PCI, robotic CABG has been shown to offer the advantage of LITA-LAD in combination with stent for non-LAD territory. CONCLUSION: High-risk, fragile patients, with low EF and high STS score that undergo urgent CABG can benefit from heart-team collaboration, and HCR is an important tool in the armamentarium.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico , Resultado do Tratamento
6.
J Card Surg ; 37(12): 5411-5417, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36403259

RESUMO

OBJECTIVES: To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. METHODS: We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. RESULTS: Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%-6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%-3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%-0.7% and Perceval 0%-1%), endocarditis (Intuity 0.2%-0.7% and Perceval 1.6%-6.6%), stroke (Intuity 0.36%-1.4% and Perceval 0%-0.8%), MI (Intuity 0.07%-0.26%), and SVD (Intuity 0.12%-0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%-2.1% for SFS. Hospital costs outcomes ranged from $37,187-$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. CONCLUSIONS: This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Card Surg ; 37(10): 3300-3310, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35971783

RESUMO

BACKGROUND: Outcomes of transcatheter aortic valve implantation (TAVI) versus surgical aortic valve replacement (SAVR) in patients with aortic stenosis and bicuspid aortic valve (BAV) must be better investigated. METHODS: A meta-analysis including studies published by January 2022 reporting immediate outcomes (in-hospital death, stroke, acute kidney injury [AKI], major bleeding, new permanent pacemaker implantation [PPI], paravalvular leakage [PVL]), mortality in the follow-up (with Kaplan-Meier curves for reconstruction of individual patient data). RESULTS: Five studies met our eligibility criteria. No statistically significant difference was observed for in-hospital death, stroke, AKI, and PVL. TAVI was associated with lower risk of major bleeding (odds ratio [OR]: 0.29; 95% confidence interval [CI]: 0.12-0.69; p = .025), but higher risk of PPI (OR: 2.00; 95% CI: 1.05-3.77; p = .041). In the follow-up, mortality after TAVI was significantly higher in the analysis with the largest samples (HR: 1.24, 95% CI: 1.01-1.53, p = .043), but no statistically significant difference was observed with risk-adjusted populations (HR: 1.06, 95% CI: 0.86-1.32, p = .57). Landmark analyses suggested a time-varying risk with TAVI after 10 and 13 months in both largest and risk-adjusted populations (HR: 2.13, 95% CI: 1.45-3.12, p < .001; HR: 1.7, 95% CI: 1.11-2.61, p = .015, respectively). CONCLUSION: Considering the immediate outcomes and comparable overall survival observed in risk-adjusted populations, TAVI can be used safely in selected BAV patients. However, a time-varying risk is present (favoring SAVR over TAVI at a later timepoint). This finding was likely driven by higher rates of PPI with TAVI.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar , Humanos , Valva Mitral/cirurgia , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
J Card Surg ; 37(11): 3525-3535, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35998275

RESUMO

BACKGROUND: Off-pump coronary artery bypass (OPCAB) previously demonstrated its potential benefits in women; however, robotic-assisted OPCAB was scarcely studied. OBJECTIVES: To investigate whether robotic-assisted OPCAB could further improve the outcomes in women and the potential impact of hybrid approaches with stents and completeness of revascularization on the late outcomes. METHODS: Women who underwent robotic-assisted or conventional OPCAB (with sternotomy) between May 2005 and January 2021 at Lankenau Heart Institute were included. Propensity score matching was used to match 273 pairs on 27 characteristics. RESULTS: In the intraoperative period, women who underwent robotic-assisted OPCAB presented longer operative times (6.00 vs. 5.38 h; p < 0.001), higher rates of extubation in the operating room (83.9% vs. 75.5%; p = 0.019) and lower rates of blood transfusion (13.2% vs. 32.2%; p < 0.001). In the postoperative period, women who underwent robotic-assisted OPCAB presented lower rates of new onset atrial fibrillation (16.8% vs. 25.6%; p = 0.016), need of blood transfusion (33.0% vs. 54.9%; p < 0.001), shorter intensive care unit (ICU) (46.1 vs. 49.8 h; p = 0.006) and hospital length of stay (5.0 vs. 6.0 days; p < 0.001). We observed no statistically significant differences in the rates of operative death between the groups (1.47% vs. 1.47%; p = 0.771). In the follow-up, we observed no differences in terms of overall survival regardless of hybrid procedures with stents and completeness of revascularization. CONCLUSIONS: Robotic-assisted OPCAB in women is as safe as conventional OPCAB and may further improve outcomes. Hybrid coronary revascularization was a valuable adjunct in the robotic scenario and completeness of revascularization did not play a role in this setting.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Procedimentos Cirúrgicos Robóticos , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Feminino , Humanos , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
9.
Circulation ; 142(14): 1342-1350, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-33017212

RESUMO

BACKGROUND: Equipoise exists between the use of leaflet resection and preservation for surgical repair of mitral regurgitation caused by prolapse. We therefore performed a randomized, controlled trial comparing these 2 techniques, particularly in regard to functional mitral stenosis. METHODS: One hundred four patients with degenerative mitral regurgitation surgically amenable to either leaflet resection or preservation were randomized at 7 specialized cardiac surgical centers. Exclusion criteria included anterior leaflet or commissural prolapse, as well as a mixed cause for mitral valve disease. Using previous data, we determined that a sample size of 88 subjects would provide 90% power to detect a 5-mm Hg difference in mean mitral valve gradient at peak exercise, assuming an SD of 6.7 mm with a 2-sided test with α=5% and 10% patient attrition. The primary end point was the mean mitral gradient at peak exercise 12 months after repair. RESULTS: Patient age, proportion who were female, and Society of Thoracic Surgeons risk score were 63.9±10.4 years, 19%, and 1.4±2.8% for those who were assigned to leaflet resection (n=54), and 66.3±10.8 years, 16%, and 1.9±2.6% for those who underwent leaflet preservation (n=50). There were no perioperative deaths or conversions to replacement. At 12 months, moderate mitral regurgitation was observed in 3 subjects in the leaflet resection group and 2 in the leaflet preservation group. The mean transmitral gradient at 12 months during peak exercise was 9.1±5.2 mm Hg after leaflet resection and 8.3±3.3 mm Hg after leaflet preservation (P=0.43). The participants had similar resting peak (8.3±4.4 mm Hg versus 8.4±2.6 mm Hg; P=0.96) and mean resting (3.2±1.9 mm Hg versus 3.1±1.1 mm Hg; P=0.67) mitral gradients after leaflet resection and leaflet preservation, respectively. The 6-minute walking distance was 451±147 m for those in the leaflet resection versus 481±95 m for the leaflet preservation group (P=0.27). CONCLUSIONS: In this adequately powered randomized trial, repair of mitral prolapse with either leaflet resection or leaflet preservation was associated with similar transmitral gradients at peak exercise at 12 months postoperatively. These data do not support the hypothesis that a strategy of leaflet resection (versus preservation) is associated with a risk of functional mitral stenosis. Registration: URL: https://www.clinicaltrials.gov; Unique identifier NCT02552771.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Curr Opin Cardiol ; 36(2): 154-162, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399359

RESUMO

PURPOSE OF REVIEW: The review summarizes the key parameters that can aid in determining the optimal treatment of ischemic mitral regurgitation (IMR). RECENT FINDINGS: Left ventricular (LV) and mitral valve (MV) parameters are important for surgical planning and risk stratification in IMR. Although LV dimensions is one of the main parameters used in the guidelines, volumes more accurately depict LV remodelling. Furthermore, wall motion abnormalities and wall motion score index can also be useful for surgical planning in treatment of IMR. Viability is best measured with cardiac magnetic resonance, but it is not feasible in certain centres. In contrast, measurement of strain with echocardiography is an emerging and feasible tool for estimating viability. MV leaflet tethering and pattern measured with echocardiography are also useful for MV surgery. Anterior leaflet excursion angle can identify patients in whom undersized ring annuloplasty is potentially unsuitable. SUMMARY: Treatment of IMR relies on accurate parameters that can determine the optimal surgical approach. In some patients, lack of viable myocardium suggests inadequacy of revascularization and thus, an adjunctive left ventricular reconstruction may be necessary. Degree and pattern of MV leaflet tethering can indicate whether ring annuloplasty, which is the most common repair technique, is sufficient or an adjunctive sub-valvular intervention is beneficial.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Isquemia Miocárdica , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/cirurgia
11.
Curr Opin Cardiol ; 36(2): 125-129, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33395077

RESUMO

PURPOSE OF REVIEW: To provide a critical review of the application and outcomes of surgical edge-to-edge (E2E) or Alfieri repair for mitral valvulopathy. RECENT FINDINGS: The E2E repair is a surgical technique to address mitral regurgitation, particularly suited when the responsible mechanism is bileaflet prolapse combined with enlarged annular area. It can also be used for a range of mitral valve pathologies. Surgically, the technique has been employed as a bailout for unsuccessful repair including residual mitral regurgitation because of systolic anterior motion (SAM). E2E repair should be accompanied by a ring annuloplasty for long-term repair durability. The simplicity of this approach makes it an ideal strategy during minimally-invasive mitral valve repair. It may also be performed via a transaortic approach at the time of aortic valve surgery to address less-than-severe mitral regurgitation or to address residual SAM following myectomy for hypertrophic obstructive cardiomyopathy. We review the surgical indication, potential complications including risk of mitral stenosis and the long-term outcomes of E2E repair. SUMMARY: The E2E surgical repair is a simple and effective surgical strategy to address a wide range of mitral regurgitation. This is an important technique in the surgical armamentarium especially in cases of minimally-invasive mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
12.
J Cardiothorac Vasc Anesth ; 35(11): 3223-3231, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34175205

RESUMO

OBJECTIVE: To compare early and midterm outcomes of transcatheter valve-in-valve implantation (ViV-TAVI) and redo surgical aortic valve replacement (re-SAVR) for aortic bioprosthetic valve degeneration. DESIGN: Patients who underwent ViV-TAVI and re-SAVR for aortic bioprosthetic valve degeneration between January 2010 and October 2018 were retrospectively analyzed. Mean follow-up was 3.0 years. SETTING: In-hospital, early, and mid-term outcomes. PARTICIPANTS: Eighty-eight patients were included in the analysis. INTERVENTIONS: Thirty-one patients (37.3%) had ViV-TAVI, and 57 patients (62.7%) had re-SAVR. MEASUREMENTS AND MAIN RESULTS: In the ViV-TAVI group, patients were older (79.1 ± 7.4 v 67.2 ± 14.1, p < 0.01). The total operative time, intubation time, intensive care unit length of stay, total hospital length of stay, inotropes infusion, intubation >24 hours, total amount of chest tube losses, red blood cell transfusions, plasma transfusions, and reoperation for bleeding were significantly higher in the re-SAVR cohort (p < 0.01). There was no difference regarding in-hospital permanent pacemaker implantation (ViV-TAVI = 3.2% v re-SAVR = 8.8%, p = 0.27), patient-prosthesis mismatch (ViV-TAVI = 12 patients [mean 0.53 ± 0.07] and re-SAVR = ten patients [mean 0.56 ± 0.08], p = 0.4), stroke (ViV-TAVI = 3.2% v re-SAVR = 7%, p = 0.43), acute kidney injury (ViV-TAVI = 9.7% v re-SAVR = 15.8%, p = 0.1), and all-cause infections (ViV-TAVI = 0% v re-SAVR = 8.8%, p = 0.02), between the two groups. In-hospital mortality was 0% and 7% for ViV-TAVI and re-SAVR, respectively (p = 0.08). At three-years' follow-up, the incidence of pacemaker implantation was higher in the re-SAVR group (ViV-TAVI = 0 v re-SAVR = 13.4%, p < 0.01). There were no differences in reintervention (ViV-TAVI = 3.8% v re-SAVR = 0%, p = 0.32) and survival (ViV-TAVI = 83.9% v re-SAVR = 93%, p = 0.10) between the two cohorts. CONCLUSIONS: ViV-TAVI is a safe, feasible, and reliable procedure.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
13.
J Card Surg ; 36(11): 4224-4225, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34463399

RESUMO

In the jungle of biomarkers that predicts long-term outcome, there are many discrepancies and there is more evidence from single-center retrospective studies rather than clinical trials. While some of these biomarkers such as high sensitivity troponin levels, creatine kinase (CK), and CK-MB have demonstrated a good pattern for patients' follow-up, other biomarkers are still struggling to get validated and internationally renown due to the small number of patients included in the studies and their retrospective nature. In this context, Brown and colleagues must be congratulated as they have marked the pathway for future clinical trials.


Assuntos
Peptídeo Natriurético Encefálico , Troponina , Biomarcadores , Creatina Quinase Forma MB , Humanos , Estudos Retrospectivos
14.
J Card Surg ; 35(11): 2934-2942, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32789903

RESUMO

OBJECTIVE: To analyze predictors that influence the learning curve of minimally invasive mitral valve surgery (MIMVS). METHODS: Patients who underwent MIMVS between March 2010 to March 2015 were retrospectively analyzed. Predictive factors that influence the learning curve were analyzed. RESULTS: One hundred and five patients were included in the analysis. Cardiopulmonary bypass (CPB) time in minutes was 158.72 ± 40.98 and the aortic cross-clamp (ACC) time in minutes was 114.48 ± 27.29. There were three operative mortalities, one stroke and five >2+ mitral regurgitation. ACC time in minutes was higher in the low logistic Euroscore II (LES) group (LES < 5% = 118.42 ± 27.94) versus (LES ≥ 5 = 88.66 ± 22.26), P < .05 while creatinine clearance in µmol/L was higher in the LES < 5% group (LES < 5% = 84.32 ± 33.7) versus (LES ≥ 5% = 41.66 ± 17.14), (P < .05). One patient from each group required chest tube insertion for pleural effusion P < .05. The cumulative sum analysis (CUSUM) for the first 25 patients had CPB and ACC times that reached the upper limits. Between 25 to 64 patients the curve remained stable while with the introduction of reoperations and complex surgical procedures the CUSUM reached the upper limits. CONCLUSIONS: The learning curve is affected by many factors but this should not desist surgeons from approaching this technique. The introduction of high-risk patients in clinical practice should be carefully measured based on surgeon experience.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Curva de Aprendizado , Procedimentos Cirúrgicos Minimamente Invasivos , Valva Mitral/cirurgia , Cirurgiões , Idoso , Índice de Massa Corporal , Constrição , Bases de Dados como Assunto , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Reoperação , Estudos Retrospectivos
15.
Heart Lung Circ ; 29(10): 1502-1510, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32165084

RESUMO

AIM: The aim was to use a propensity score-based analysis to determine the impact of peripheral artery disease (PAD) on early outcomes after coronary artery bypass surgery grafting (CABG) in patients with PAD. METHOD: We conducted a multicentre retrospective analysis of 11,311 consecutive patients who underwent CABG between 1997 and 2017. Patients with previous or concomitant vascular surgery were excluded. The main endpoints were death, stroke, and limb ischaemia requiring percutaneous or surgical revascularisation. Subgroup analyses were performed to test the interaction of PAD with concomitant factors. RESULTS: There was no difference in mortality in patients with and without PAD (p=0.06 and p=0.179, respectively). Patients with PAD had a greater incidence of stroke (p=0.04), acute kidney disease (p=0.003), and limb ischaemia requiring interventions (p<0.001) than those without PAD. The use of off-pump or no-touch aortic techniques did not influence the effect of PAD on the outcomes. Early mortality rate increased in patients with PAD when associated with long cardiopulmonary bypass, cross-clamp times (both p<0.001), and postoperative low cardiac output (p=0.01). CONCLUSIONS: The presence of PAD is associated, independently of other factors, with greater incidence of stroke, acute kidney disease, and limb ischaemia following CABG, irrespective of the technique employed. Operative mortality was greater in patients with PAD only when associated with long cardiopulmonary bypass and aortic cross-clamp times, and low cardiac output.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Doença Arterial Periférica/complicações , Pontuação de Propensão , Idoso , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/epidemiologia , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento
20.
J Card Fail ; 22(11): 901-907, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26952240

RESUMO

PURPOSE: To evaluate potential relationships between different components of left ventricular (LV) function and histopathological evidence for myocardial fibrosis in patients undergoing heart transplantation. METHODS: The study population included patients with advanced heart failure, referred for an echocardiographic examination before heart transplantation. Traditional LV function measurements and global longitudinal strain (GLS) by speckle tracking echocardiography, averaging all LV segments in 4-, 2-, and 3-chamber views were obtained in all subjects. LV tissue samples were obtained from all patients who underwent heart transplantation. Myocardial fibrosis was assessed using Masson's staining. RESULTS: Of 106 patients referred for cardiac transplantation, 47 underwent cardiac transplantation and were enrolled in the study. LV myocardial fibrosis and its grade strongly correlated with GLS (r = 0.75, P = .0001), modestly with global circumferential strain and LV torsion (r = 0.61, P = .001 and r = 0.52, P = .01, respectively) and weakly with mitral S' wave (r = -0.41; P = .01) and mitral annular plane systolic excursion (r = -0.35; P = .05) but did not correlate with LV ejection fraction (r = -0.12; P = NS). GLS had the strongest accuracy for detecting LV fibrosis (area under the curve, 0.92). None of the echo parameters correlated with patient's exercise capacity. CONCLUSION: Global longitudinal strain is the most accurate LV global function measure that correlates with the extent of myocardial fibrosis in patients with advanced systolic HF requiring heart transplantation.


Assuntos
Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Interpretação de Imagem Assistida por Computador , Miocárdio/patologia , Disfunção Ventricular Esquerda/epidemiologia , Idoso , Biópsia por Agulha , Estudos de Coortes , Comorbidade , Bases de Dados Factuais , Ecocardiografia/métodos , Feminino , Fibrose/diagnóstico por imagem , Fibrose/epidemiologia , Fibrose/patologia , Fibrose/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Transplante de Coração/mortalidade , Mortalidade Hospitalar , Humanos , Imuno-Histoquímica , Itália , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Análise de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA