1.
Sensors (Basel) ; 23(7)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37050587

RESUMO

In bio-signal denoising, current methods reported in the literature consider purely simulated environments, requiring high computational powers and signal processing algorithms that may introduce signal distortion. To achieve an efficient noise reduction, such methods require previous knowledge of the noise signals or to have certain periodicity and stability, making the noise estimation difficult to predict. In this paper, we solve these challenges through the development of an experimental method applied to bio-signal denoising using a combined approach. This is based on the implementation of unconventional electric field sensors used for creating a noise replica required to obtain the ideal Wiener filter transfer function and achieve further noise reduction. This work aims to investigate the suitability of the proposed approach for real-time noise reduction affecting bio-signal recordings. The experimental evaluation presented here considers two scenarios: (a) human bio-signals trials including electrocardiogram, electromyogram and electrooculogram; and (b) bio-signal recordings from the MIT-MIH arrhythmia database. The performance of the proposed method is evaluated using qualitative criteria (i.e., power spectral density) and quantitative criteria (i.e., signal-to-noise ratio and mean square error) followed by a comparison between the proposed methodology and state of the art denoising methods. The results indicate that the combined approach proposed in this paper can be used for noise reduction in electrocardiogram, electromyogram and electrooculogram signals, achieving noise attenuation levels of 26.4 dB, 21.2 dB and 40.8 dB, respectively.

2.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540669

RESUMO

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.


Assuntos
Leitos , Eletrocardiografia , Monitorização Fisiológica , Dispositivos Eletrônicos Vestíveis , Eletrodos , Humanos , Recém-Nascido , Têxteis
3.
Matern Health Neonatol Perinatol ; 8(1): 9, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36414979

RESUMO

BACKGROUND: Reducing the global new-born mortality is a paramount challenge for humanity. There are approximately 786,323 live births in the UK each year according to the office for National Statistics; around 10% of these newborn infants require assistance during this transition after birth. Each year around, globally around 2.5 million newborns die within their first month. The main causes are complications due to prematurity and during delivery. To act in a timely manner and prevent further damage, health professionals should rely on accurate monitoring of the main vital signs heart rate and respiratory rate. AIMS: To present a clinical perspective on innovative, non-invasive methods to monitor heart rate and respiratory rate in babies highlighting their advantages and limitations in comparison with well-established methods. METHODS: Using the data collected in our recently published systematic review we highlight the barriers and facilitators for the novel sensor devices in obtaining reliable heart rate measurements. Details about difficulties related to the application of sensors and interfaces, time to display, and user feedback are explored. We also provide a unique overview of using a non-invasive respiratory rate monitoring method by extracting RR from the pulse oximetry trace of newborn babies. RESULTS: Novel sensors to monitor heart rate offer the advantages of minimally obtrusive technologies but have limitations due to movement artefact, bad sensor coupling, intermittent measurement, and poor-quality recordings compared to gold standard well established methods. Respiratory rate can be derived accurately from pleth recordings in infants. CONCLUSION: Some limitations have been identified in current methods to monitor heart rate and respiratory rate in newborn babies. Novel minimally invasive sensors have advantages that may help clinical practice. Further research studies are needed to assess whether they are sufficiently accurate, practical, and reliable to be suitable for clinical use.