Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
AAPS J ; 17(5): 1144-56, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25967925

RESUMO

Recombinant human PH20 hyaluronidase (rHuPH20) is used to facilitate dispersion of subcutaneously delivered fluids and drugs. This report summarizes rHuPH20 immunogenicity findings from clinical trials where rHuPH20 was co-administered with SC human immunoglobulin, trastuzumab, rituximab, or insulin. Plasma samples were obtained from evaluable subjects participating in ten different clinical trials as well as from healthy plasma donors. A bridging immunoassay and a modified hyaluronidase activity assay were used to determine rHuPH20-reactive antibody titers and neutralizing antibodies, respectively. rHuPH20-binding antibody populations from selected subjects with positive titers were affinity-purified and subjected to further characterization such as cross-reactivity with endogenous PH20. Among individual trials, the prevalence of pre-existing rHuPH20-reactive antibodies varied between 3 and 12%, excepting the primary immunodeficiency (PID) studies. Incidence of treatment-induced rHuPH20 antibodies was 2 to 18%, with the highest titers (81,920) observed in PID. No neutralizing antibodies were observed. Within most trials, the kinetics of antibody responses were comparable between pre-existing and treatment-induced antibody responses, although responses classified as persistent were more common in subjects with pre-existing titers. There was no association between antibody positivity and either local or systemic adverse events. Pre-existing and treatment-induced antibody populations were of similar immunoglobulin isotypes and cross-reacted to endogenous PH20 to similar extents. No cross-reactivity to PH20 paralogs was detected. rHuPH20 induces only modest immunogenicity which has no association with adverse events. In addition, antibodies purified from baseline-positive individuals are qualitatively similar to those purified from individuals developing rHuPH20-reactive antibodies following exposure to the enzyme.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos/sangue , Hialuronoglucosaminidase/administração & dosagem , Proteínas Recombinantes/administração & dosagem , Ensaios Clínicos como Assunto , Humanos , Hialuronoglucosaminidase/imunologia , Injeções Subcutâneas , Insulina/administração & dosagem , Proteínas Recombinantes/imunologia , Rituximab/administração & dosagem , Trastuzumab/administração & dosagem
2.
Drug Deliv Transl Res ; 2(4): 254-64, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25787031

RESUMO

Many patients with primary immunodeficiency disease (PIDD) require lifelong immunoglobulin (Ig) replacement therapy. Home-based subcutaneous (SC) infusion provides advantages to patients with PIDD compared to hospital-based intravenous infusion. One limitation of current practice with SCIg infusion is the need for small-volume infusions at multiple injection sites on a frequent basis. A method was developed for large-volume SC infusion that uses preinfusion of recombinant human hyaluronidase (rHuPH20) to facilitate fluid dispersion. Miniature swine was used as a preclinical model to assess the effects of rHuPH20-facilitated infusions, of a single monthly dose, on fluid dispersion, infusion-related pressure, swelling, induration, and tissue damage. Preinfusion of vehicle (control) or rHuPH20 (75 U/g Ig) was performed simultaneously on contralateral abdominal sites on each animal, followed by infusion of 300 mL 10 % Ig (30 g) at each site. Compared to control infusions, rHuPH20 significantly reduced infusion pressure and induration (p < 0.05) and accelerated postinfusion Ig dispersion. Histological evaluation of infusion site tissue showed moderate to severe swelling for the control. Swelling after rHuPH20-facilitated infusion was mild on day 1 and had completely resolved shortly thereafter. Laser Doppler imaging of control infusion sites revealed local cutaneous hypoperfusion during Ig infusion, which was reduced almost 7-fold (p < 0.05) with the use of rHuPH20. These results demonstrate that rHuPH20-facilitated Ig infusion is associated with improved dispersion of Ig, resulting in reduced tissue pressure, induration, and reduced risk of tissue damage from mechanical trauma or local ischemia, thus enabling SC administration of large volumes of Ig at a single site.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA