Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiother Oncol ; 118(3): 510-4, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26631647

RESUMO

BACKGROUND AND PURPOSE: Deep inspiration breath hold (DIBH) increases lung volume and can potentially reduce treatment-related toxicity in locally advanced lung cancer. We estimated geometric uncertainties in visually guided voluntary DIBH and derived the appropriate treatment margins for different image-guidance strategies. MATERIAL AND METHODS: Seventeen patients were included prospectively. An optical marker-based respiratory monitoring with visual guidance enabled comfortable DIBHs, adjusted to each patient's performance. All patients had three consecutive DIBH CTs at each of the treatment fractions 2, 16 and 31. DIBH reproducibility was evaluated as inter- and intra-fractional variations in lung volume, tumour position and differential motion between primary tumour and mediastinal lymph nodes. RESULTS: Lung volume increased by median 60% in DIBH. Inter- and intra-fractional lung volume variations were median 2.1% and 1.1%, respectively. Inter- and intra-fractional uncertainties in 3D tumour position were 4.8 ± 2.8 mm and 1.7 ± 1.4 mm (mean ± SD). Inter- and intra-fractional differential motion was 4.8 ± 3.3 mm and 0.0 ± 1.1 mm. CONCLUSIONS: For single targets, visually guided voluntary DIBH radiotherapy is highly reproducible provided an image-guidance strategy with tumour registration is performed. If the primary tumour is separated from the mediastinal lymph nodes, inter-fractional differential motion remains a challenge and margins must be adapted to reflect the image registration strategy.


Assuntos
Suspensão da Respiração , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Feminino , Humanos , Hiperventilação , Neoplasias Pulmonares/patologia , Medidas de Volume Pulmonar/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Incerteza
2.
Int J Radiat Oncol Biol Phys ; 95(1): 534-541, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26797540

RESUMO

PURPOSE: The safe clinical implementation of pencil beam scanning (PBS) proton therapy for lung tumors is complicated by the delivery uncertainties caused by breathing motion. The purpose of this feasibility study was to investigate whether a voluntary breath-hold technique could limit the delivery uncertainties resulting from interfractional motion. METHODS AND MATERIALS: Data from 15 patients with peripheral lung tumors previously treated with stereotactic radiation therapy were included in this study. The patients had 1 computed tomographic (CT) scan in voluntary breath-hold acquired before treatment and 3 scans during the treatment course. PBS proton treatment plans with 2 fields (2F) and 3 fields (3F), respectively, were calculated based on the planning CT scan and subsequently recalculated on the 3 repeated CT scans. Recalculated plans were considered robust if the V95% (volume receiving ≥95% of the prescribed dose) of the gross target volume (GTV) was within 5% of what was expected from the planning CT data throughout the simulated treatment. RESULTS: A total of 14/15 simulated treatments for both 2F and 3F met the robustness criteria. Reduced V95% was associated with baseline shifts (2F, P=.056; 3F, P=.008) and tumor size (2F, P=.025; 3F, P=.025). Smaller tumors with large baseline shifts were also at risk for reduced V95% (interaction term baseline/size: 2F, P=.005; 3F, P=.002). CONCLUSIONS: The breath-hold approach is a realistic clinical option for treating lung tumors with PBS proton therapy. Potential risk factors for reduced V95% are small targets in combination with large baseline shifts. On the basis of these results, the baseline shift of the tumor should be monitored (eg, through image guided therapy), and appropriate measures should be taken accordingly. The intrafractional motion needs to be investigated to confirm that the breath-hold approach is robust.


Assuntos
Suspensão da Respiração , Neoplasias Pulmonares/radioterapia , Terapia com Prótons/métodos , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Movimento , Hipofracionamento da Dose de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA