Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Stem Cells ; 32(6): 1380-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24497003

RESUMO

CD34 is a transmembrane phosphoglycoprotein, first identified on hematopoietic stem and progenitor cells. Clinically, it is associated with the selection and enrichment of hematopoietic stem cells for bone marrow transplants. Due to these historical and clinical associations, CD34 expression is almost ubiquitously related to hematopoietic cells, and it is a common misconception that CD34-positive (CD34(+) ) cells in nonhematopoietic samples represent hematopoietic contamination. The prevailing school of thought states that multipotent mesenchymal stromal cells (MSC) do not express CD34. However, strong evidence demonstrates CD34 is expressed not only by MSC but by a multitude of other nonhematopoietic cell types including muscle satellite cells, corneal keratocytes, interstitial cells, epithelial progenitors, and vascular endothelial progenitors. In many cases, the CD34(+) cells represent a small proportion of the total cell population and also indicate a distinct subset of cells with enhanced progenitor activity. Herein, we explore common traits between cells that express CD34, including associated markers, morphology and differentiation potential. We endeavor to highlight key similarities between CD34(+) cells, with a focus on progenitor activity. A common function of CD34 has yet to be elucidated, but by analyzing and understanding links between CD34(+) cells, we hope to be able to offer an insight into the overlapping properties of cells that express CD34.


Assuntos
Antígenos CD34/metabolismo , Células-Tronco/metabolismo , Animais , Anticorpos/metabolismo , Antígenos CD34/química , Biomarcadores/metabolismo , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Células Epiteliais/metabolismo , Humanos , Células-Tronco/citologia , Células Estromais/citologia , Células Estromais/metabolismo
2.
Cell Transplant ; 26(11): 1717-1732, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29338382

RESUMO

When used as scaffolds for cell therapies, biomaterials often present basic handling and logistical problems for scientists and surgeons alike. The quest for an appropriate mounting device for biomaterials is therefore a significant and common problem. In this review, we provide a detailed overview of the factors to consider when choosing an appropriate mounting device including those experienced during cell culture, quality assurance, and surgery. By way of example, we draw upon our combined experience in developing epithelial cell therapies for the treatment of eye diseases. We discuss commercially available options for achieving required goals and provide a detailed analysis of 4 experimental designs developed within our respective laboratories in Australia, the United Kingdom, and Belgium.


Assuntos
Materiais Biocompatíveis/química , Terapia Baseada em Transplante de Células e Tecidos/métodos , Âmnio/citologia , Humanos , Oftalmologia
3.
Curr Eye Res ; 41(6): 769-82, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26397030

RESUMO

BACKGROUND: There is a clinical need for biomimetic corneas that are as effective, preferably superior, to cadaveric donor tissue. Decellularized tissues are advantageous compared to synthetic or semi-synthetic engineered tissues in that the native matrix ultrastructure and intrinsic biological cues including growth factors, cytokines and glycosaminoglycans may be retained. However, there is currently no reliable, standardized human corneal decellularization protocol. METHODS: Corneal eye-bank tissue unsuitable for transplantation was utilized to systematically compare commonly used decellularization protocols. Hypertonic sodium chloride; an ionic reagent, sodium dodecyl sulphate; a non-ionic detergent, tert-octylphenol polyoxyethylene (Triton-X); enzymatic disaggregation using Dispase; mechanical agitation; and the use of nucleases were investigated. Decellularization efficacy, specifically for human corneal tissue, was extensively evaluated. Removal of detectable cellular material was evidenced by histological, immunofluorescence and biochemical assays. Preservation of macroscopic tissue transparency and light transmittance was evaluated. Retention of corneal architecture, collagen and glycosaminoglycans was assessed via histological, immunofluorescence and quantitative analysis. Biocompatibility of the resulting scaffolds was assessed using cell proliferation assays. RESULTS: None of the decellularization protocols investigated successfully removed 100% of cellular components. The techniques with the least residual cellular material were most structurally compromised. Biochemical analysis of glycosaminoglycans demonstrated the stripping effects of the decellularization procedures. CONCLUSION: The ability to utilize, reprocess and regenerate tissues deemed "unsuitable" for transplantation allows us to salvage valuable tissue. Reprocessing the tissue has the potential to have a considerable impact on addressing the problems associated with cadaveric donor shortage. Patients would directly benefit by accessing greater numbers of corneal grafts and health authorities would fulfill their responsibility for the delivery of effective corneal reconstruction to alleviate corneal blindness. However, in order to progress, we may need to take a step back to establish a "decellularization" criterion; which should balance effective removal of immune reactive material with maintenance of tissue functionality.


Assuntos
Córnea/citologia , Transplante de Córnea , Doadores de Tecidos , Engenharia Tecidual/métodos , Alicerces Teciduais , Proliferação de Células , Córnea/cirurgia , Bancos de Olhos , Humanos
4.
J Mech Behav Biomed Mater ; 38: 251-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24809968

RESUMO

In this study, collagen-elastin constructs were prepared with the aim of producing a material capable of mimicking the mechanical properties of a single alveolar wall. Collagen has been used in a wide range of tissue engineering applications; however, due to its low mechanical properties its use is limited to non load-bearing applications without further manipulation using methods such as cross-linking or mechanical compression. Here, it was hypothesised that the addition of soluble elastin to a collagen hydrogel could improve its mechanical properties. Hydrogels made from collagen only and collagen plus varying amounts elastin were prepared. Young׳s modulus of each membrane was measured using the combination of a non-destructive indentation and a theoretical model previously described. An increase in Young׳s modulus was observed with increasing concentration of elastin. The use of non-destructive indentation allowed for online monitoring of the elastic moduli of cell-seeded constructs over 8 days. The addition of lung fibroblasts into the membrane increased the stiffness of the hydrogels further and cell-seeded collagen hydrogels were found to have a stiffness equal to the theoretical value for a single alveolar wall (≈5kPa). Through provision of some of the native extracellular matrix components of the lung parenchyma these scaffolds may be able to provide an initial building block toward the regeneration of new functional lung tissue.


Assuntos
Materiais Biocompatíveis/farmacologia , Colágeno/metabolismo , Elastina/metabolismo , Hidrogéis/farmacologia , Fenômenos Mecânicos , Engenharia Tecidual , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Colágeno/química , Módulo de Elasticidade/efeitos dos fármacos , Elastina/química , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Humanos , Ratos
5.
J Funct Biomater ; 4(3): 114-61, 2013 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-24956084

RESUMO

The worldwide limited availability of suitable corneal donor tissue has led to the development of alternatives, including keratoprostheses (Kpros) and tissue engineered (TE) constructs. Despite advances in bioscaffold design, there is yet to be a corneal equivalent that effectively mimics both the native tissue ultrastructure and biomechanical properties. Human decellularized corneas (DCs) could offer a safe, sustainable source of corneal tissue, increasing the donor pool and potentially reducing the risk of immune rejection after corneal graft surgery. Appropriate, human-specific, decellularization techniques and high-resolution, non-destructive analysis systems are required to ensure reproducible outputs can be achieved. If robust treatment and characterization processes can be developed, DCs could offer a supplement to the donor corneal pool, alongside superior cell culture systems for pharmacology, toxicology and drug discovery studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA