Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
ASAIO J ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38870474

RESUMO

Patients supported on ventricular assist devices (VADs) benefit from rehabilitation while awaiting heart transplantation to recover from surgery, prevent deconditioning, and, in most cases, optimize transplant candidacy. With bleeding and neurological dysfunction as the most common VAD complications, the importance of rehabilitation dramatically increases when a patient on a VAD also suffers from a neurological injury. The rehabilitation needs for cardiac conditioning and neurological reeducation are not the same. Patients with severe neurological deficits require intense rehabilitation that often includes base-of-support challenges, usage of bolsters and balls, partial weight-bearing treadmill training, and assumption of various body positions in prone, kneeling, or quadruped for neuromotor reeducation. However, some devices are more conducive to rehabilitation than others. For children supported by the CentriMag in particular, rehabilitation is challenged by short cannula tubing, an external motor, a large interface, and an intensive care unit (ICU) admission. We report a safe and successful physical therapy course of a pediatric stroke patient with a diagnosis of Ebstein's anomaly supported by a CentriMag right VAD (RVAD) while awaiting heart transplant in the ICU.

2.
ASAIO J ; 70(7): 602-608, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949774

RESUMO

We report the largest pediatric multicenter experience with Impella pump use and peripheral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. Utilizing the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) collaborative database, we conducted a retrospective, multicenter study of all patients with cardiogenic shock requiring VA-ECMO support with subsequent Impella implant between October 2014 and December 2021. The primary outcome was defined as death while on Impella support. Secondary outcomes were recovery, transplantation, and transition to durable ventricular assist device (VAD) at the time of Impella explantation. Adverse events were defined according to the ACTION registry criteria. Twenty subjects were supported with Impella; Impella 2.5 (n = 3), CP (n = 12), 5.0/5.5 (n = 5). The median Interquartile range (IQR) age, weight, and body surface area at implantation were 15.6 years (IQR = 13.9-17.2), 65.7 kg (IQR = 53.1-80.7), and 1.74 m2 (IQR = 1.58-1.98). Primary cardiac diagnoses were dilated cardiomyopathy/myocarditis in nine (45%), congenital heart disease in four (20%), graft failure/rejection in four (20%), and three (15%) others. Most common adverse events included hemolysis (50%) and bleeding (20%). There were two deaths (10%) in the cohort. Nine patients (45%) were explanted for recovery, eight (40%) were transitioned to a durable VAD, and one (5%) underwent heart transplantation. Impella percutaneous pump support should be considered in the older pediatric population supported with peripheral VA-ECMO, as a means of left heart decompression, and a strategy to come off ECMO to achieve endpoints of myocardial recovery, transition to a durable VAD, or transplantation.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Choque Cardiogênico , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Masculino , Feminino , Adolescente , Choque Cardiogênico/terapia , Criança , Pré-Escolar , Resultado do Tratamento
3.
J Am Coll Cardiol ; 84(7): 620-632, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39111968

RESUMO

BACKGROUND: In 2016, the United Network for Organ Sharing revised its pediatric heart transplant (HT) allocation policy. OBJECTIVES: This study sought to determine whether the 2016 revisions are associated with reduced waitlist mortality and capture patient-specific risks. METHODS: Children listed for HT from 1999 to 2023 were identified using Organ Procurement and Transplantation Network data and grouped into 3 eras (era 1: 1999-2006; era 2: 2006-2016; era 3: 2016-2023) based on when the United Network for Organ Sharing implemented allocation changes. Fine-Gray competing risks modeling was used to identify factors associated with death or delisting for deterioration. Fixed-effects analysis was used to determine whether allocation changes were associated with mortality. RESULTS: Waitlist mortality declined 8 percentage points (PP) across eras (21%, 17%, and 13%, respectively; P < 0.01). At listing, era 3 children were less sick than era 1 children, with 6 PP less ECMO use (P < 0.01), 11 PP less ventilator use (P < 0.01), and 1 PP less dialysis use (P < 0.01). Ventricular assist device (VAD) use was 13 PP higher, and VAD mortality decreased 9 PP (P < 0.01). Non-White mortality declined 10 PP (P < 0.01). ABO-incompatible listings increased 27 PP, and blood group O infant mortality decreased 13 PP (P < 0.01). In multivariable analyses, the 2016 revisions were not associated with lower waitlist mortality, whereas VAD use (in era 3), ABO-incompatible transplant, improved patient selection, and narrowing racial disparities were. Match-run analyses demonstrated poor correlation between individual waitlist mortality risk and the match-run order. CONCLUSIONS: The 2016 allocation revisions were not independently associated with the decline in pediatric HT waitlist mortality. The 3-tier classification system fails to adequately capture patient-specific risks. A more flexible allocation system that accurately reflects patient-specific risks and considers transplant benefit is urgently needed.


Assuntos
Transplante de Coração , Listas de Espera , Humanos , Listas de Espera/mortalidade , Transplante de Coração/mortalidade , Criança , Masculino , Feminino , Pré-Escolar , Lactente , Adolescente , Estados Unidos/epidemiologia , Obtenção de Tecidos e Órgãos/estatística & dados numéricos , Estudos Retrospectivos
4.
J Heart Lung Transplant ; 43(6): 889-900, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38713124

RESUMO

BACKGROUND: There is no FDA-approved left ventricular assist device (LVAD) for smaller children permitting routine hospital discharge. Smaller children supported with LVADs typically remain hospitalized for months awaiting heart transplant-a major burden for families and a challenge for hospitals. We describe the initial outcomes of the Jarvik 2015, a miniaturized implantable continuous flow LVAD, in the NHLBI-funded Pumps for Kids, Infants, and Neonates (PumpKIN) study, for bridge-to-heart transplant. METHODS: Children weighing 8 to 30 kg with severe systolic heart failure and failing optimal medical therapy were recruited at 7 centers in the United States. Patients with severe right heart failure and single-ventricle congenital heart disease were excluded. The primary feasibility endpoint was survival to 30 days without severe stroke or non-operational device failure. RESULTS: Of 7 children implanted, the median age was 2.2 (range 0.7, 7.1) years, median weight 10 (8.2 to 20.7) kilograms; 86% had dilated cardiomyopathy; 29% were INTERMACS profile 1. The median duration of Jarvik 2015 support was 149 (range 5 to 188) days where all 7 children survived including 5 to heart transplant, 1 to recovery, and 1 to conversion to a paracorporeal device. One patient experienced an ischemic stroke on day 53 of device support in the setting of myocardial recovery. One patient required ECMO support for intractable ventricular arrhythmias and was eventually transplanted from paracorporeal biventricular VAD support. The median pump speed was 1600 RPM with power ranging from 1-4 Watts. The median plasma free hemoglobin was 19, 30, 19 and 30 mg/dL at 7, 30, 90 and 180 days or time of explant, respectively. All patients reached the primary feasibility endpoint. Patient-reported outcomes with the device were favorable with respect to participation in a full range of activities. Due to financial issues with the manufacturer, the study was suspended after consent of the eighth patient. CONCLUSION: The Jarvik 2015 LVAD appears to hold important promise as an implantable continuous flow device for smaller children that may support hospital discharge. The FDA has approved the device to proceed to a 22-subject pivotal trial. Whether this device will survive to commercialization remains unclear because of the financial challenges faced by industry seeking to develop pediatric medical devices. (Supported by NIH/NHLBI HHS Contract N268201200001I, clinicaltrials.gov 02954497).


Assuntos
Estudos de Viabilidade , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Pré-Escolar , Criança , Masculino , Lactente , Feminino , Estudos Prospectivos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/fisiopatologia , Miniaturização , Desenho de Prótese , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA