Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Environ Sci Technol ; 49(9): 5618-27, 2015 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-25880018

RESUMO

The California Air Resources Board (ARB) adopted the low emission vehicle (LEV) III particulate matter (PM) standards in January 2012, which require, among other limits, vehicles to meet 1 mg/mi over the federal test procedure (FTP). One possible alternative measurement approach evaluated to support the implementation of the LEV III standards is integrated particle size distribution (IPSD), which reports real-time PM mass using size distribution and effective density. The IPSD method was evaluated using TSI's engine exhaust particle sizer (EEPS, 5.6-560 nm) and gravimetric filter data from more than 250 tests and 34 vehicles at ARB's Haagen-Smit Laboratory (HSL). IPSD mass was persistently lower than gravimetric mass by 56-75% over the FTP tests and by 81-84% over the supplemental FTP (US06) tests. Strong covariance between the methods suggests test-to-test variability originates from actual vehicle emission differences rather than measurement accuracy, where IPSD offered no statistical improvement over gravimetric measurement variability.


Assuntos
Veículos Automotores , Tamanho da Partícula , Material Particulado/análise , Emissões de Veículos/análise , California , Gasolina/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA