Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Hum Brain Mapp ; 44(5): 1901-1912, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36546653

RESUMO

The identification of meaningful functional magnetic resonance imaging (fMRI) biomarkers requires measures that reliably capture brain performance across different subjects and over multiple scanning sessions. Recent developments in fMRI acquisition, such as the introduction of multiband (MB) protocols and in-plane acceleration, allow for increased scanning speed and improved temporal resolution. However, they may also lead to reduced temporal signal to noise ratio and increased signal leakage between simultaneously excited slices. These methods have been adopted in several scanning modalities including diffusion weighted imaging and fMRI. To our knowledge, no study has formally compared the reliability of the same resting-state fMRI (rs-fMRI) metrics (amplitude of low-frequency fluctuations; seed-to-voxel and region of interest [ROI]-to-ROI connectivity) across conventional single-band fMRI and different MB acquisitions, with and without in-plane acceleration, across three sessions. In this study, 24 healthy older adults were scanned over three visits, on weeks 0, 1, and 4, and, on each occasion, underwent a conventional single band rs-fMRI scan and three different rs-fMRI scans with MB factors 4 and 6, with and without in-plane acceleration. Across all three rs-fMRI metrics, the reliability scores were highest with MB factor 4 with no in-plane acceleration for cortical areas and with conventional single band for subcortical areas. Recommendations for future research studies are discussed.


Assuntos
Mapeamento Encefálico , Envelhecimento Saudável , Humanos , Idoso , Mapeamento Encefálico/métodos , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
2.
Hum Brain Mapp ; 39(4): 1743-1754, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29341323

RESUMO

The hippocampal formation is a complex brain structure that is important in cognitive processes such as memory, mood, reward processing and other executive functions. Histological and neuroimaging studies have implicated the hippocampal region in neuropsychiatric disorders as well as in neurodegenerative diseases. This highly plastic limbic region is made up of several subregions that are believed to have different functional roles. Therefore, there is a growing interest in imaging the subregions of the hippocampal formation rather than modelling the hippocampus as a homogenous structure, driving the development of new automated analysis tools. Consequently, there is a pressing need to understand the stability of the measures derived from these new techniques. In this study, an automated hippocampal subregion segmentation pipeline, released as a developmental version of Freesurfer (v6.0), was applied to T1-weighted magnetic resonance imaging (MRI) scans of 22 healthy older participants, scanned on 3 separate occasions and a separate longitudinal dataset of 40 Alzheimer's disease (AD) patients. Test-retest reliability of hippocampal subregion volumes was assessed using the intra-class correlation coefficient (ICC), percentage volume difference and percentage volume overlap (Dice). Sensitivity of the regional estimates to longitudinal change was estimated using linear mixed effects (LME) modelling. The results show that out of the 24 hippocampal subregions, 20 had ICC scores of 0.9 or higher in both samples; these regions include the molecular layer, granule cell layer of the dentate gyrus, CA1, CA3 and the subiculum (ICC > 0.9), whilst the hippocampal fissure and fimbria had lower ICC scores (0.73-0.88). Furthermore, LME analysis of the independent AD dataset demonstrated sensitivity to group and individual differences in the rate of volume change over time in several hippocampal subregions (CA1, molecular layer, CA3, hippocampal tail, fissure and presubiculum). These results indicate that this automated segmentation method provides a robust method with which to measure hippocampal subregions, and may be useful in tracking disease progression and measuring the effects of pharmacological intervention.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Envelhecimento Saudável , Hipocampo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Reconhecimento Automatizado de Padrão/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/patologia , Seguimentos , Envelhecimento Saudável/patologia , Hipocampo/patologia , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Software
3.
Front Hum Neurosci ; 16: 980280, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36438643

RESUMO

Leading Eigenvector Dynamics Analysis (LEiDA) is an analytic approach that characterizes brain activity recorded with functional Magnetic Resonance Imaging (fMRI) as a succession of discrete phase-locking patterns, or states, that consistently recur over time across all participants. LEiDA allows for the extraction of three state-related measures which have previously been key to gaining a better understanding of brain dynamics in both healthy and clinical populations: the probability of occurrence of a given state, its lifetime and the probability of switching from one state to another. The degree to which test-retest reliability of the LEiDA measures may be affected by increasing MRI multiband (MB) factors in comparison with single band sequences is yet to be established. In this study, 24 healthy older adults were scanned over three sessions, on weeks 0, 1, and 4. On each visit, they underwent a conventional single band resting-state fMRI (rs-fMRI) scan and three different MB rs-fMRI scans, with MB factors of 4, with and without in-plane acceleration, and 6 without in-plane acceleration. We found test-retest reliability scores to be significantly higher with MB factor 4 with and without in-plane acceleration for most cortical networks. These findings will inform the choice of acquisition parameters for future studies and clinical trials.

4.
J Alzheimers Dis ; 49(4): 1123-34, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26639957

RESUMO

BACKGROUND: Bapineuzumab, an anti-amyloid-ß monoclonal antibody, was evaluated in two placebo-controlled trials in APOE*ɛ4 carriers and noncarriers, respectively, with Alzheimer's disease. OBJECTIVES: A volumetric magnetic resonance imaging substudy was performed to determine if bapineuzumab altered brain volume rate of change. METHODS: Bapineuzumab dosages included 0.5 mg/kg in carriers and 0.5 or 1.0 mg/kg in noncarriers, every 13 weeks for 78 weeks. Volumetric outcomes included annualized brain, ventricular, and mean hippocampal boundary shift integrals (BBSI; VBSI; HBSI) up to Week 71. Treatment differences were estimated using mixed models for repeated measures. RESULTS: For BBSI and HBSI, there were no significant treatment-related differences within either study, but, compared to pooled carriers and noncarriers receiving placebo, noncarriers receiving1.0 mg/kg bapineuzumab had greater increases in these measures. Bapineuzumab-treated patients showed significantly greater VBSI rates compared with placebo for 0.5 mg/kg in carriers and 1.0 mg/kg (but not 0.5 mg/kg) in noncarriers. CONCLUSIONS: Bapineuzumab produced an increase in ventricular volume compared with placebo. Etiology for this increase is unclear but may be related to amyloid-ß clearance or its consequences.


Assuntos
Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/patologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Encéfalo/efeitos dos fármacos , Encéfalo/patologia , Nootrópicos/uso terapêutico , Idoso , Doença de Alzheimer/genética , Apolipoproteína E4/genética , Método Duplo-Cego , Feminino , Heterozigoto , Humanos , Análise dos Mínimos Quadrados , Imageamento por Ressonância Magnética , Masculino , Tamanho do Órgão , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Arthritis Rheum ; 56(12): 4005-14, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18050198

RESUMO

OBJECTIVE: To compare the efficacy of adalimumab versus placebo in reducing spinal and sacroiliac (SI) joint inflammation, by magnetic resonance imaging (MRI) in patients with active ankylosing spondylitis (AS). METHODS: This was a randomized, multicenter, double-blind, placebo-controlled study. Patients (n = 82) received 40 mg adalimumab or placebo every other week during an initial 24-week double-blind period. MRIs of both the spine and SI joints were obtained at baseline, week 12, and week 52. Spinal and SI joint inflammation were measured using the Spondyloarthritis Research Consortium of Canada (SPARCC) MRI index. RESULTS: The spine SPARCC score in placebo-treated patients increased by a mean of 9.4% from baseline, compared with a mean decrease of 53.6% in adalimumab-treated patients (P < 0.001); the SI joint SPARCC score decreased by a mean of 12.7% from baseline in placebo-treated patients and by 52.9% in adalimumab-treated patients (P = 0.017). The response in adalimumab-treated patients was maintained at week 52. Placebo-treated patients were switched to open-label adalimumab treatment at week 24 and experienced similar reductions in spinal and SI joint inflammation by week 52. Similar large reductions in the spine and SI joint SPARCC scores were noted, even in patients who failed to meet the ASsessment in Ankylosing Spondylitis (International Working Group) criteria (nonresponders) at 12 weeks. In adalimumab-treated patients, a reduced C-reactive protein concentration at week 12 was significantly associated with improvement in the spine SPARCC score (P = 0.018). CONCLUSION: Adalimumab significantly reduced both spinal and SI joint inflammation in patients with active AS after 12 weeks of treatment, and these improvements were maintained for up to 52 weeks.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Antirreumáticos/uso terapêutico , Articulação Sacroilíaca/patologia , Coluna Vertebral/patologia , Espondilite Anquilosante/tratamento farmacológico , Adalimumab , Adulto , Anticorpos Monoclonais Humanizados , Proteína C-Reativa/metabolismo , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Articulação Sacroilíaca/metabolismo , Índice de Gravidade de Doença , Coluna Vertebral/metabolismo , Espondilite Anquilosante/metabolismo , Espondilite Anquilosante/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA