Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 28(10): 1876-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17898189

RESUMO

We report a case of rhabdomyolysis due to acetaminophen overdose involving the lateral pterygoid muscles bilaterally, in addition to the other muscles of the abdomen and pelvis. To the best of our knowledge, involvement of the head and neck muscles by rhabdomyolysis has not been reported previously. The isolated involvement of the lateral pterygoid muscles may be due to the presence of the surrounding pterygoid venous plexus. It is important to be aware of the imaging characteristics of rhabdomyolysis and to consider the possibility of involvement of head and neck muscles to aid in early diagnosis and avoid misinterpretation of the imaging findings.


Assuntos
Músculos Pterigoides , Rabdomiólise/induzido quimicamente , Rabdomiólise/diagnóstico , Acetaminofen/intoxicação , Adulto , Humanos , Imageamento por Ressonância Magnética , Masculino , Músculos Pterigoides/diagnóstico por imagem , Músculos Pterigoides/patologia , Tentativa de Suicídio , Tomografia Computadorizada por Raios X
2.
Circ Res ; 85(6): 524-33, 1999 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-10488055

RESUMO

The role of reactive oxygen species, such as superoxide anions (O(2). (-)) and hydrogen peroxide (H(2)O(2)), in modulating vascular smooth muscle cell proliferation and viability is controversial. To investigate the role of endogenously produced H(2)O(2), rat aortic smooth muscle cells were infected with adenoviral vectors containing cDNA for human catalase (AdCat) or a control gene, beta-galactosidase (AdLacZ). Infection with AdCat resulted in dose-dependent increases in intracellular catalase protein, which was predominantly localized to peroxisomes. After infection with 100 multiplicity of infection (MOI) of AdCat, cellular catalase activity was increased by 50- to 100-fold, and intracellular H(2)O(2) concentration was reduced, as compared with control. Infection with AdCat reduced [(3)H]thymidine uptake, an index of DNA synthesis, in cells maintained in medium supplemented with 2% serum (0.37+/-0.09 disintegrations per minute per cell [AdLacZ] versus 0.22+/-0.08 disintegrations per minute per cell [AdCat], P<0.05). Five days after infection with 100 MOI of AdCat, cell numbers were reduced as compared with noninfected or AdLacZ-infected cells (157 780+/-8413 [AdCat], P<0.05 versus 233 700+/-3032 [noninfected] or 222 410+/-5332 [AdLacZ]). Furthermore, the number of apoptotic cells was increased 5-fold after infection with 100 MOI of AdCat as compared with control. Infection with AdCat resulted in induction of cyclooxygenase (COX)-2, and treatment with a COX-2 inhibitor overcame the AdCat-induced reduction in cell numbers. These findings indicate that overexpression of catalase inhibited smooth muscle proliferation while increasing the rate of apoptosis, possibly through a COX-2-dependent mechanism. Our results suggest that endogenously produced H(2)O(2) importantly modulates survival and proliferation of vascular smooth muscle cells.


Assuntos
Apoptose/fisiologia , Catalase/metabolismo , Músculo Liso Vascular/fisiologia , Animais , Catalase/genética , Divisão Celular/fisiologia , Células Cultivadas , Ciclo-Oxigenase 2 , Técnicas de Transferência de Genes , Humanos , Membranas Intracelulares/metabolismo , Isoenzimas/metabolismo , Proteínas de Membrana , Músculo Liso Vascular/citologia , Músculo Liso Vascular/enzimologia , Prostaglandina-Endoperóxido Sintases/metabolismo , Ratos , Ratos Sprague-Dawley , Espécies Reativas de Oxigênio/metabolismo
3.
Br J Radiol ; 86(1021): 18244135, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22960243

RESUMO

OBJECTIVES: In three experiments, we studied the detection of multiple abnormality types using the satisfaction of search (SOS) paradigm, the provision of a computer-aided detection (CAD) of pulmonary nodules and a focused nodule detection task. METHODS: 51 chest CT examinations (24 that demonstrated subtle pulmonary nodules and 27 that demonstrated no pulmonary nodules) were read by 15 radiology residents and fellows under two experimental conditions: (1) when there were no other abnormalities present except test abnormalities in the exams (non-SOS condition), and (2) when other abnormalities were present in the exams (SOS condition). Trials from the two conditions were intermixed. Readers were invited to return for two sessions: one in which the SOS condition was repeated with a simulated CAD; another in which only the non-SOS condition was presented. Detection accuracy was measured using receiver operating characteristic (ROC) analysis. RESULTS: An SOS effect (reduced detection accuracy for the test nodules in the presence of the diverse added abnormalities) was not found. Average accuracy was much higher when the CAD prompt was provided, without cost in the detection of the added abnormalities. Accuracy for detecting nodules appearing without intermixed SOS trials was also substantially improved. CONCLUSIONS: CT interpretation was highly task dependent. Nodule detection was poor in the general search task. Therefore, CAD may offer a greater performance improvement than demonstrated in experiments assessing CAD using focused search. The absence of SOS may be due to limited nodule detection even without other abnormalities. Advances in knowledge CAD prompts of nodules increase the detection accuracy of nodules and decrease the time to detection-without impairing the detection accuracy-of non-nodule abnormalities.


Assuntos
Algoritmos , Neoplasias Pulmonares/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Reações Falso-Negativas , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Br J Radiol ; 86(1021): 20110799, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23239691

RESUMO

Objectives In three experiments, we studied the detection of multiple abnormality types using the satisfaction of search (SOS) paradigm, the provision of a computer-aided detection (CAD) of pulmonary nodules and a focused nodule detection task. Methods 51 chest CT examinations (24 that demonstrated subtle pulmonary nodules and 27 that demonstrated no pulmonary nodules) were read by 15 radiology residents and fellows under two experimental conditions: (1) when there were no other abnormalities present except test abnormalities in the exams (non-SOS condition), and (2) when other abnormalities were present in the exams (SOS condition). Trials from the two conditions were intermixed. Readers were invited to return for two sessions: one in which the SOS condition was repeated with a simulated CAD; another in which only the non-SOS condition was presented. Detection accuracy was measured using receiver operating characteristic (ROC) analysis. Results An SOS effect (reduced detection accuracy for the test nodules in the presence of the diverse added abnormalities) was not found. Average accuracy was much higher when the CAD prompt was provided, without cost in the detection of the added abnormalities. Accuracy for detecting nodules appearing without intermixed SOS trials was also substantially improved. Conclusions CT interpretation was highly task dependent. Nodule detection was poor in the general search task. Therefore, CAD may offer a greater performance improvement than demonstrated in experiments assessing CAD using focused search. The absence of SOS may be due to limited nodule detection even without other abnormalities. Advances in knowledge CAD prompts of nodules increase the detection accuracy of nodules and decrease the time to detection-without impairing the detection accuracy-of non-nodule abnormalities.


Assuntos
Algoritmos , Inteligência Artificial , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA