Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Microbiol ; 61(11): e0082723, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37902331

RESUMO

The symptomology is overlapping for respiratory infections due to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), influenza A/B viruses, and respiratory syncytial virus (RSV). Accurate detection is essential for proper medical management decisions. This study evaluated the clinical performance of the Panther Fusion SARS-CoV-2/Flu A/B/RSV assay in nasopharyngeal swab (NPS) specimens from individuals of all ages with signs and symptoms of respiratory infection consistent with COVID-19, influenza, or RSV. Retrospective known-positive and prospectively obtained residual NPS specimens were collected during two respiratory seasons in the USA. Clinical performance was established by comparing Panther Fusion SARS-CoV-2/Flu assay results to a three-molecular assay composite comparator interpretation for SARS-CoV-2 and to the FDA-cleared Panther Fusion Flu A/B/RSV assay results for all non-SARS-CoV-2 targets. A total of 1,900 prospective and 95 retrospective NPS specimens were included in the analyses. The overall prevalence in prospectively obtained specimens was 20.7% for SARS-CoV-2, 6.7% for influenza A, and 0.7% for RSV; all influenza B-positive specimens were retrospective specimens. The positive percent agreement of the Panther Fusion assay was 96.9% (378/390) for SARS-CoV-2, 98.0% (121/123) for influenza A virus, 95.2% (20/21) for influenza B virus, and 96.6% (57/59) for RSV. The negative percent agreement was ≥98.5% for all target viruses. Specimens with discordant Panther Fusion SARS/Flu/RSV assay results all had cycle threshold values of ≥32.4 (by comparator or by Panther Fusion SARS/Flu/RSV assay). Only five co-infections were detected in the study specimens. The Panther Fusion SARS-CoV-2/Flu/RSV assay provides highly sensitive and specific detection of SARS-CoV-2, influenza A virus, influenza B virus, and RSV in NPS specimens.


Assuntos
COVID-19 , Vírus da Influenza A , Influenza Humana , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Infecções Respiratórias , Humanos , Influenza Humana/diagnóstico , SARS-CoV-2 , Estudos Retrospectivos , Estudos Prospectivos , Infecções por Vírus Respiratório Sincicial/diagnóstico , Nasofaringe , COVID-19/diagnóstico , Sensibilidade e Especificidade , Vírus da Influenza B , Infecções Respiratórias/diagnóstico
2.
Clin Chem Lab Med ; 61(8): 1511-1517, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36799248

RESUMO

OBJECTIVES: To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. METHODS: Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. RESULTS: TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at -20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. CONCLUSIONS: The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Sensibilidade e Especificidade , Teste para COVID-19 , Imunoensaio
3.
J Clin Microbiol ; 60(12): e0135622, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36472424

RESUMO

Early-onset neonatal sepsis due to Streptococcus agalactiae (group B Streptococcus [GBS]) infection is one of the leading causes of newborn mortality and morbidity. The latest guidelines published in 2019 recommended universal screening of GBS colonization among all pregnant women and intrapartum antibiotic prophylaxis for positive GBS. The updated procedures allow rapid molecular-based GBS screening using nutrient broth-enriched rectovaginal samples. Commercially available molecular assays for GBS diagnosis target mainly the cfb gene, which encodes a hemolysin protein responsible for producing the Christie-Atkins-Munch-Petersen (CAMP) factor. cfb is considered a conserved gene in essentially all GBS isolates. However, false-negative GBS results on Cepheid Xpert GBS and GBS LB tests due to deletions in or near the region that encodes cfb were reported recently. Therefore, the new Xpert GBS LB XC test was developed. This study is a multicenter evaluation of the new test for GBS identification from nutrient broth-enriched rectal/vaginal samples from antepartum women. A total of 621 samples were prospectively enrolled. The samples were tested with the Xpert GBS LB XC test, the composite comparator method, which included the Hologic Panther Fusion GBS test combined with bacterial culture, followed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, and bacterial culture alone, followed by MALDI-TOF MS identification. The respective sensitivity and specificity of the Xpert GBS LB XC test were 99.3% and 98.7% compared to the composite comparator method and 99.1% and 91.8% compared to bacterial culture alone with MALDI-TOF MS identification. Overall, the Xpert GBS LB XC test performed comparatively to the composite comparator method and is equivalent to traditional bacterial culture followed by MALDI-TOF MS.


Assuntos
Complicações Infecciosas na Gravidez , Infecções Estreptocócicas , Recém-Nascido , Gravidez , Feminino , Humanos , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/microbiologia , Vagina/microbiologia , Streptococcus agalactiae/genética , Infecções Estreptocócicas/diagnóstico , Infecções Estreptocócicas/microbiologia , Sensibilidade e Especificidade
4.
J Clin Microbiol ; 58(4)2020 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-31941690

RESUMO

Automation of the clinical microbiology laboratory has become more prominent as laboratories face higher specimen volumes and understaffing and are becoming more consolidated. One recent advancement is the use of digital image analysis to rapidly distinguish between chromogenic growth for screening bacterial cultures. In this study, colony segregation software developed by Copan (Brescia, Italy) was evaluated to distinguish between significant growth and no growth of urine cultures plated onto standard blood and MacConkey agars. Specimens from 3 sites were processed on a WASP instrument (Copan) and incubated on the WASPLab platform (Copan), and plates were imaged at 0 and 24 hours postinoculation. Images were read by technologists following validated laboratory protocols (VLPs), and results were recorded in the laboratory information systems (LIS). Image analysis performed colony counts on the 24-hour images, and results were compared with the VLP. A total of 12,931 urine cultures were tested and analyzed with an overall sensitivity and specificity of 99.8% and 72.0%, respectively. After secondary review, 91.1% of manual-positive/automation-negative specimens were due to expert rules that reported the plate as contaminated or growing only normal flora and not due to threshold counts. Nine specimens were found to be manual-positive/automation-negative; a secondary review demonstrated that the results of 8 of these specimens were due to growth of microcolonies that were programmed to be ignored by the software and 1 were due to a colony count near the limit of significance. Overall, the image analysis software proved to be highly sensitive and can be utilized by laboratories to batch-review negative cultures to improve laboratory workflow.


Assuntos
Automação Laboratorial , Técnicas Bacteriológicas , Meios de Cultura , Humanos , Itália , Software , Urina
5.
J Clin Microbiol ; 58(2)2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31776191

RESUMO

Clostridioides difficile is the leading cause of diarrhea in hospitalized U.S. patients and results in over 400,000 cases of C. difficile infection per year. C. difficile infections have mortality rates of 6 to 30% and significantly increase health care costs, because of increased length of stay and increased frequency of readmissions due to recurrences. Efforts to reduce the spread of C. difficile in hospitals have led to the development of rapid sensitive diagnostic methods. A multicenter study was performed to establish the performance characteristics of the Revogene C. difficile test (Meridian Bioscience, Cincinnati, OH, USA) for use in detection of the toxin B (tcdB) gene from toxigenic C. difficile The Revogene instrument is a new molecular platform that uses real-time PCR to detect nucleic acids in up to 8 specimens at a time. A total of 2,461 specimens from symptomatic patients that had been submitted for C. difficile testing were enrolled at 7 sites throughout the United States and Canada for evaluation of the assay. Each stool specimen was tested for the presence of the tcdB gene using the Revogene C. difficile test, and results were compared with those of the reference method, a combination of direct and enriched culture methods. Overall, the Revogene C. difficile test demonstrated a sensitivity of 85.0% (95% confidence interval, 80% to 88%) and a specificity of 97.2% (95% confidence interval, 96% to 98%). The Revogene C. difficile test, using clinical stool specimens for detection of tcdB in C. difficile, demonstrated acceptable sensitivity and specificity, with a short turnaround time.


Assuntos
Proteínas de Bactérias/genética , Toxinas Bacterianas/genética , Clostridioides difficile/genética , Infecções por Clostridium/diagnóstico , Fezes/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Adolescente , Adulto , Canadá , Criança , Pré-Escolar , Infecções por Clostridium/microbiologia , Diarreia/microbiologia , Humanos , Lactente , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Estados Unidos , Adulto Jovem
6.
J Clin Microbiol ; 58(7)2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-32376668

RESUMO

NG-Test Carba 5 is a rapid in vitro multiplex immunoassay for the phenotypic detection and differentiation of five common carbapenemase families (KPC, OXA-48-like, VIM, IMP, and NDM) directly from bacterial colonies. The assay is simple to perform and has recently received U.S. Food and Drug Administration clearance. A method comparison study was performed at geographically diverse medical centers (n = 3) in the United States, where 309 Enterobacterales and Pseudomonas aeruginosa isolates were evaluated by NG-Test Carba 5 (NG Biotech, Guipry, France), the Xpert Carba-R assay (Cepheid, Inc., Sunnyvale, CA), the modified carbapenem inactivation method (mCIM), the EDTA-modified carbapenem inactivation method, and disk diffusion with carbapenems. Colonies from tryptic soy agar with 5% sheep blood (blood agar) and MacConkey agar were tested, and the results were compared to those obtained by a composite reference method. Additionally, a fourth medical center performed a medium comparison study by evaluating the performance characteristics of NG-Test Carba 5 from blood, MacConkey, and Mueller-Hinton agars with 110 isolates of Enterobacterales and P. aeruginosa These results were compared to the expected genotypic and mCIM results. For the multicenter method comparison study, the overall positive percent agreement (PPA) and the overall negative percent agreement (NPA) of NG-Test Carba 5 with the composite reference method were 100% for both blood and MacConkey agars. The medium comparison study at the fourth site showed that the PPA ranged from 98.9% to 100% and that the NPA ranged from 95.2% to 100% for blood, MacConkey, and Mueller-Hinton agars. NG-Test Carba 5 accurately detected and differentiated five common carbapenemase families from Enterobacterales and P. aeruginosa colonies on commonly used agar media. The results of this test will support a streamlined laboratory work flow and will expedite therapeutic and infection control decisions.


Assuntos
Proteínas de Bactérias , beta-Lactamases , Animais , Proteínas de Bactérias/genética , França , Sensibilidade e Especificidade , Ovinos , beta-Lactamases/genética
7.
J Clin Microbiol ; 58(7)2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-32350045

RESUMO

Lower respiratory tract infections, including hospital-acquired and ventilator-associated pneumonia, are common in hospitalized patient populations. Standard methods frequently fail to identify the infectious etiology due to the polymicrobial nature of respiratory specimens and the necessity of ordering specific tests to identify viral agents. The potential severity of these infections combined with a failure to clearly identify the causative pathogen results in administration of empirical antibiotic agents based on clinical presentation and other risk factors. We examined the impact of the multiplexed, semiquantitative BioFire FilmArray Pneumonia panel (PN panel) test on laboratory reporting for 259 adult inpatients submitting bronchoalveolar lavage (BAL) specimens for laboratory analysis. The PN panel demonstrated a combined 96.2% positive percent agreement (PPA) and 98.1% negative percent agreement (NPA) for the qualitative identification of 15 bacterial targets compared to routine bacterial culture. Semiquantitative values reported by the PN panel were frequently higher than values reported by culture, resulting in semiquantitative agreement (within the same log10 value) of 43.6% between the PN panel and culture; however, all bacterial targets reported as >105 CFU/ml in culture were reported as ≥105 genomic copies/ml by the PN panel. Viral targets were identified by the PN panel in 17.7% of specimens tested, of which 39.1% were detected in conjunction with a bacterial target. A review of patient medical records, including clinically prescribed antibiotics, revealed the potential for antibiotic adjustment in 70.7% of patients based on the PN panel result, including discontinuation or de-escalation in 48.2% of patients, resulting in an average savings of 6.2 antibiotic days/patient.


Assuntos
Gestão de Antimicrobianos , Pneumonia , Infecções Respiratórias , Adulto , Humanos , Técnicas de Diagnóstico Molecular , Reação em Cadeia da Polimerase Multiplex , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/tratamento farmacológico
8.
J Clin Microbiol ; 58(1)2019 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-31694967

RESUMO

Urine cultures are among the most common specimens received by clinical laboratories and generate a major share of the laboratory workload. Chromogenic agar can expedite culture results, but technologist review is still needed. In this study, we evaluated the ability of the WASPLab software to interpret urine specimens plated onto chromID CPS Elite (CPSE) agar. Urine specimens submitted for bacterial culture were plated onto CPSE agar with a 1-µl loop using the WASP. Each plate was imaged after 0 and 18 h of incubation, and colonies were enumerated by color using the WASPLab software and a technologist's reading from a high-definition (HD) monitor. The results were reported as negative if <10 colonies/plate were detected. Laboratory information system (LIS) time stamps were used to measure the time to result. A total of 1,581 urine cultures were tested. The sensitivity and specificity of the software were 99.8% and 68.5%, respectively, which included 2 manual-positive/automation-negative (MP/AN) results and 170 manual-negative/automation-positive (MN/AP) results. Of the 170 MN/AP specimens, 116 were caused by microcolonies missed by the technologist. The remaining MN/AP results were caused by either count differences near the 10-colony threshold (n = 43) or count differences of >50 CFU (n = 11). The use of both CPSE agar and the WASPLab software improved the time to result for urine culture, reducing the average time to result by 4 h 42 min for negative specimens and 3 h 28 min for positive specimens compared to that with standard-of-care testing. These data demonstrate that the use of CPSE agar and automated plate reading has the potential to improve turnaround time while maintaining high sensitivity and reducing urine culture workload.


Assuntos
Automação Laboratorial , Técnicas Bacteriológicas , Software , Urinálise/métodos , Compostos Cromogênicos , Meios de Cultura , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Urinálise/normas , Infecções Urinárias/diagnóstico , Infecções Urinárias/microbiologia
9.
J Clin Microbiol ; 57(11)2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31484700

RESUMO

The prevalence of tick-borne infections has been steadily increasing in both number and geographic distribution in the United States and abroad. This increase, in conjunction with the continued recognition of novel pathogens transmitted by ticks, has made accurate diagnosis of these infections challenging. Mainstay serologic tests are insensitive during the acute phase of infection and are often cross-reactive with similar pathogenic and nonpathogenic organisms. Further, they are unable to reliably differentiate active versus past infection which can lead to misdiagnosis and incorrect understanding of the epidemiology and incidence of specific tick-borne pathogens. We evaluated a novel multiplexed high-definition PCR (HDPCR) Tickborne Panel (TBP) assay (ChromaCode, Carlsbad, CA) for the detection of nine tick-borne pathogens or groups associated with human illness. The HDPCR technology enables multiplex identification of multiple targets in a single fluorometric channel based on fluorescent signal modulation using a limiting probe design. A collection of 530 whole-blood specimens collected from patients being evaluated for tick-borne infections, in addition to a panel of 93 simulated specimens, were used to challenge the HDPCR TBP. The results were compared to a clinically validated traditional multiplexed PCR test with additional sequence analysis and clinical history collected to aid in resolving discrepancies. Among clinical specimens the TBP demonstrated 100% sensitivity for the identification of Anaplasma phagocytophilum, Borrelia miyamotoi, Borrelia mayonii, and Rickettsia rickettsii The sensitivity for identification of B. burgdorferi was 44.4% compared to a composite gold standard. Among simulated specimens containing single or multiple targets present at 103 to 105 copies/PCR, the sensitivity of TBP was 100% for all targets, with a combined specificity of 99.5%. Of note, an increased rate of false-positive results was observed among simulated specimens that contained multiple targets. Based on these data, we find the HDPCR TBP to be a useful adjunct for the diagnosis of tick-borne infections in patients with suspected tick-borne illness.


Assuntos
Bactérias/isolamento & purificação , Reação em Cadeia da Polimerase Multiplex/métodos , Doenças Transmitidas por Carrapatos/sangue , Doenças Transmitidas por Carrapatos/diagnóstico , Bactérias/patogenicidade , Proteínas de Bactérias/genética , Reações Falso-Positivas , Fluorescência , Corantes Fluorescentes , Humanos , Sensibilidade e Especificidade
10.
J Clin Microbiol ; 55(12): 3328-3338, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28855303

RESUMO

Early initiation of effective antibiotics for septic patients is essential for patient survival. Matrix-assisted desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has revolutionized clinical microbiology for isolate identification and has the possibility to impact how blood culture testing is performed. This review discusses the various uses of MALDI-TOF MS for the identification and susceptibility testing of positive blood cultures, the performance of these methods, and the outcomes involved with its implementation.


Assuntos
Bactérias/isolamento & purificação , Hemocultura/métodos , Testes de Sensibilidade Microbiana/métodos , Sepse/diagnóstico , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias/classificação , Bactérias/efeitos dos fármacos , Humanos
11.
J Clin Microbiol ; 55(10): 3123-3129, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28794179

RESUMO

Liquid-based microbiology (LBM) devices incorporating flocked swabs and preservation medium ease transport of specimens and improve specimen yield compared to traditional fiber wound swabs; however, the performance of LBM collection devices has not been evaluated in many molecular assays. It is unclear how the differences in matrix and specimen loading with an LBM device will affect test performance compared to traditional collection devices. The purpose of this study was to evaluate the performance of specimens collected in FecalSwab transport medium (Copan Diagnostics, Murrieta, CA) compared to unpreserved stool using the Cepheid Xpert C. difficile assay (Cepheid, Sunnyvale, CA). Results equivalent to unpreserved stool samples were obtained when 400 µl of FecalSwab-preserved stool was employed in the Xpert assay. The positive and negative percent agreement of specimens inoculated with FecalSwab medium (n = 281) was 97.0% (95% confidence interval [CI], 90.9 to 96.4%) and 99.4% (95% CI, 96.4 to 99.9%), respectively, compared to reference results obtained using unpreserved stool. Throughout this study, only four discrepant results occurred when comparing preserved specimens to unpreserved stool specimens in the Xpert C. difficile PCR assay. Post discrepant analysis, using the BD MAX Cdiff assay, the specificity and sensitivity both increased to 100%. The high positive and negative percent agreements observed in this study suggest that stool preserved in FecalSwab media yields equivalent results to using unpreserved stool when tested on the Xpert C. difficile assay, allowing laboratories to adopt this liquid-based microbiology collection device.


Assuntos
Clostridioides difficile/genética , Infecções por Clostridium/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Preservação Biológica/métodos , Manejo de Espécimes/métodos , Toxinas Bacterianas/análise , Infecções por Clostridium/microbiologia , Enterotoxinas/análise , Fezes/microbiologia , Humanos , Sensibilidade e Especificidade
12.
J Clin Microbiol ; 55(4): 1140-1146, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28122871

RESUMO

Bloodstream infections are a leading cause of morbidity and mortality in the United States and are associated with increased health care costs. We evaluated the Portrait Staph ID/R blood culture panel (BCP) multiplex PCR assay (Great Basin Scientific, Salt Lake City, UT) for the rapid and simultaneous identification (ID) of Staphylococcus aureus, Staphylococcus lugdunensis, and Staphylococcus species to the genus level and the detection of the mecA gene directly from a positive blood culture bottle. A total of 765 Bactec bottles demonstrating Gram-positive cocci in singles or clusters were tested during the prospective trial at 3 clinical sites. The Portrait Staph ID/R BCP results were compared with results from conventional biochemical and cefoxitin disk methods performed at an independent laboratory. Discordant ID and mecA results were resolved by rpoB gene sequencing and mecA gene sequencing, respectively. A total of 658 Staphylococcus species isolates (S. aureus, 211 isolates; S. lugdunensis, 3 isolates; and Staphylococcus spp., 444 isolates) were recovered from monomicrobial and 33 polymicrobial blood cultures. After discrepant analysis, the overall ratios of Portrait Staph ID/R BCP positive percent agreement and negative percent agreement were 99.4%/99.9% for Staphylococcus ID and 99.7%/99.2% for mecA detection.


Assuntos
Hemocultura/métodos , Genes Bacterianos , Resistência a Meticilina , Reação em Cadeia da Polimerase Multiplex/métodos , Infecções Estafilocócicas/diagnóstico , Staphylococcus/classificação , Staphylococcus/isolamento & purificação , Humanos , Estudos Prospectivos , Infecções Estafilocócicas/microbiologia , Staphylococcus/genética , Fatores de Tempo , Estados Unidos
13.
J Clin Microbiol ; 55(2): 519-525, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27927919

RESUMO

The Shiga Toxin Direct molecular assay (ST Direct) relies on nucleic acid amplification and solid array-based amplicon detection to identify Shiga toxin-producing Escherichia coli (STEC) in preserved stool specimens. Genes encoding Shiga toxin (stx1 and stx2), as well as the E. coli serotype O:157-specific marker rfbE, are simultaneously detected within 2 h. ST Direct was evaluated using 1,084 prospectively collected preserved stool specimens across five clinical centers. An additional 55 retrospectively collected, frozen specimens were included to increase the number of positive specimens evaluated. Results were compared to results from routine culture and an enzyme immunoassay (EIA) specific for the recovery and identification of STEC. ST Direct was found to be 93.2% sensitive and 99.3% specific for detection of stx1 and stx2 and 95.7% sensitive and 99.3% specific for detection of E. coli serotype O:157. All specimens with false-positive results were found to contain stx1 or stx2 or were found to be positive for serotype O:157 when analyzed using alternative molecular methods. All 4 false-negative stx1 or stx2 results were reported for frozen, retrospectively tested specimens. In all cases, the specimens tested positive for stx by an alternative FDA-cleared nucleic acid amplification test (NAAT) but were negative for stx1 and stx2 following nucleic acid sequence analysis. Based on these data, culture and EIA-based methods for detection of STEC are only 33% sensitive compared to molecular tests. A retrospective cost analysis demonstrated 59% of the cost of routine stool culture to be attributable to the identification of STEC. Taken together, these data suggest that ST Direct may provide a cost-effective, rapid molecular alternative to routine culture for the identification of STEC in preserved stool specimens.


Assuntos
Custos e Análise de Custo , Infecções por Escherichia coli/diagnóstico , Fezes/microbiologia , Técnicas de Diagnóstico Molecular/economia , Técnicas de Diagnóstico Molecular/métodos , Toxina Shiga/genética , Escherichia coli Shiga Toxigênica/isolamento & purificação , Técnicas Bacteriológicas/métodos , Carboidratos Epimerases/genética , Humanos , Técnicas Imunoenzimáticas/métodos , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade , Escherichia coli Shiga Toxigênica/genética , Fatores de Tempo , Transaminases/genética
14.
J Clin Microbiol ; 54(10): 2436-47, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27147728

RESUMO

Infections attributable to vancomycin-resistant Enterococcus (VRE) strains have become increasingly prevalent over the past decade. Prompt identification of colonized patients combined with effective multifaceted infection control practices can reduce the transmission of VRE and aid in the prevention of hospital-acquired infections (HAIs). Increasingly, the clinical microbiology laboratory is being asked to support infection control efforts through the early identification of potential patient or environmental reservoirs. This review discusses the factors that contribute to the rise of VRE as an important health care-associated pathogen, the utility of laboratory screening and various infection control strategies, and the available laboratory methods to identify VRE in clinical specimens.


Assuntos
Infecção Hospitalar/epidemiologia , Transmissão de Doença Infecciosa/prevenção & controle , Infecções por Bactérias Gram-Positivas/epidemiologia , Instalações de Saúde , Controle de Infecções/métodos , Programas de Rastreamento/métodos , Enterococos Resistentes à Vancomicina/isolamento & purificação , Infecção Hospitalar/microbiologia , Infecções por Bactérias Gram-Positivas/microbiologia , Humanos
15.
J Clin Microbiol ; 54(10): 2464-9, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27413193

RESUMO

Vancomycin-resistant enterococci (VRE) are an important cause of health care-acquired infections (HAIs). Studies have shown that active surveillance of high-risk patients for VRE colonization can aid in reducing HAIs; however, these screens generate a significant cost to the laboratory and health care system. Digital imaging capable of differentiating negative and "nonnegative" chromogenic agar can reduce the labor cost of these screens and potentially improve patient care. In this study, we evaluated the performance of the WASPLab Chromogenic Detection Module (CDM) (Copan, Brescia, Italy) software to analyze VRE chromogenic agar and compared the results to technologist plate reading. Specimens collected at 3 laboratories were cultured using the WASPLab CDM and plated to each site's standard-of-care chromogenic media, which included Colorex VRE (BioMed Diagnostics, White City, OR) or Oxoid VRE (Oxoid, Basingstoke, United Kingdom). Digital images were scored using the CDM software after 24 or 40 h of growth, and all manual reading was performed using digital images on a high-definition (HD) monitor. In total, 104,730 specimens were enrolled and automation agreed with manual analysis for 90.1% of all specimens tested, with sensitivity and specificity of 100% and 89.5%, respectively. Automation results were discordant for 10,348 specimens, and all discordant images were reviewed by a laboratory supervisor or director. After a second review, 499 specimens were identified as representing missed positive cultures falsely called negative by the technologist, 1,616 were identified as containing borderline color results (negative result but with no package insert color visible), and 8,234 specimens were identified as containing colorimetric pigmentation due to residual matrix from the specimen or yeast (Candida). Overall, the CDM was accurate at identifying negative VRE plates, which comprised 84% (87,973) of the specimens in this study.


Assuntos
Automação Laboratorial/métodos , Técnicas Bacteriológicas/métodos , Compostos Cromogênicos/metabolismo , Meios de Cultura/química , Infecções por Bactérias Gram-Positivas/diagnóstico , Programas de Rastreamento/métodos , Enterococos Resistentes à Vancomicina/isolamento & purificação , Erros de Diagnóstico , Infecções por Bactérias Gram-Positivas/microbiologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem Óptica/métodos , Sensibilidade e Especificidade
16.
J Clin Microbiol ; 54(8): 2008-13, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27194690

RESUMO

Herpes simplex virus (HSV) causes acute and relapsing symptoms characterized by ulcerative lesions. Laboratory diagnosis of HSV in cutaneous or mucocutaneous lesions has historically been performed with the use of viral cell culture systems; however, these tests are laborious and suffer decreased sensitivity for advanced-stage lesions. The recent availability of FDA-cleared moderately complex assays has resulted in the increased use of molecular diagnostics for the routine detection of HSV in superficial swab specimens. We performed a clinical evaluation of the recently FDA-cleared illumigene HSV 1&2 loop-mediated isothermal amplification (LAMP) assay (Meridian Bioscience, Cincinnati OH) for the detection and differentiation of HSV-1 and HSV-2 in cutaneous and mucocutaneous swab specimens. A total of 1,153 clinical swab specimens were collected and tested at 7 different clinical centers. Each specimen was tested for the presence of HSV-1 and HSV-2 using the illumigene assay, and results were compared to those of the enzyme-linked virus-inducible system (ELVIS) as the reference method. Overall, the illumigene assay demonstrated a sensitivity and specificity of 94.8% and 95.5%, respectively, for the detection of HSV-1. Detection of HSV-2 was similar, with a sensitivity of 98.9% and a specificity of 95.5%. Discrepant analysis was performed using an alternative molecular test (AmpliVue HSV1+2 assay; Quidel Molecular, San Diego, CA) on 91/99 specimens that were recorded as false positive (FP) or false negative (FN) compared to the reference method. In total, 57/78 (73%) FP and 9/13 (69%) FN illumigene results were supported by the AmpliVue result. The illumigene HSV 1&2 assay demonstrated high sensitivity and specificity to detect and differentiate HSV in clinical specimens and identified 57 additional specimens that were positive for HSV compared to culture. The use of LAMP eliminates the need for the cycling of temperatures and provides results in less than 60 min, with approximately 2 min of hands-on time per specimen.


Assuntos
Herpes Genital/diagnóstico , Herpes Simples/diagnóstico , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
17.
J Clin Microbiol ; 54(1): 142-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26560532

RESUMO

Norovirus is the most common cause of sporadic gastroenteritis and outbreaks worldwide. The rapid identification of norovirus has important implications for infection prevention measures and may reduce the need for additional diagnostic testing. The Xpert Norovirus assay recently received FDA clearance for the detection and differentiation of norovirus genogroups I and II (GI and GII), which account for the vast majority of infections. In this study, we evaluated the performance of the Xpert Norovirus assay with both fresh, prospectively collected (n = 914) and frozen, archived (n = 489) fecal specimens. A Centers for Disease Control and Prevention (CDC) composite reference method was used as the gold standard for comparison. For both prospective and frozen specimens, the Xpert Norovirus assay showed positive percent agreement (PPA) and negative percent agreement (NPA) values of 98.3% and 98.1% for GI and of 99.4% and 98.2% for GII, respectively. Norovirus prevalence in the prospective specimens (collected from March to May of 2014) was 9.9% (n = 90), with the majority of positives caused by genogroup II (82%, n = 74). The positive predictive value (PPV) of the Xpert Norovirus assay was 75% for GI-positive specimens, whereas it was 86.5% for GII-positive specimens. The negative predictive values (NPV) for GI and GII were 100% and 99.9%, respectively.


Assuntos
Infecções por Caliciviridae/diagnóstico , Fezes/virologia , Genótipo , Técnicas de Diagnóstico Molecular/métodos , Norovirus/classificação , Norovirus/isolamento & purificação , Virologia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções por Caliciviridae/virologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Norovirus/genética , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem
18.
J Clin Microbiol ; 54(3): 620-4, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26719443

RESUMO

Recently, systems have been developed to create total laboratory automation for clinical microbiology. These systems allow for the automation of specimen processing, specimen incubation, and imaging of bacterial growth. In this study, we used the WASPLab to validate software that discriminates and segregates positive and negative chromogenic methicillin-resistant Staphylococcus aureus (MRSA) plates by recognition of pigmented colonies. A total of 57,690 swabs submitted for MRSA screening were enrolled in the study. Four sites enrolled specimens following their standard of care. Chromogenic agar used at these sites included MRSASelect (Bio-Rad Laboratories, Redmond, WA), chromID MRSA (bioMérieux, Marcy l'Etoile, France), and CHROMagar MRSA (BD Diagnostics, Sparks, MD). Specimens were plated and incubated using the WASPLab. The digital camera took images at 0 and 16 to 24 h and the WASPLab software determined the presence of positive colonies based on a hue, saturation, and value (HSV) score. If the HSV score fell within a defined threshold, the plate was called positive. The performance of the digital analysis was compared to manual reading. Overall, the digital software had a sensitivity of 100% and a specificity of 90.7% with the specificity ranging between 90.0 and 96.0 across all sites. The results were similar using the three different agars with a sensitivity of 100% and specificity ranging between 90.7 and 92.4%. These data demonstrate that automated digital analysis can be used to accurately sort positive from negative chromogenic agar cultures regardless of the pigmentation produced.


Assuntos
Automação Laboratorial/métodos , Técnicas Bacteriológicas/métodos , Compostos Cromogênicos/metabolismo , Meios de Cultura/química , Processamento de Imagem Assistida por Computador/métodos , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Estafilocócicas/diagnóstico , Humanos , Sensibilidade e Especificidade , Software
19.
J Clin Microbiol ; 53(2): 443-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25411176

RESUMO

Neonatal infection with Streptococcus agalactiae (group B Streptococcus [GBS]) is a leading cause of sepsis and meningitis in newborns. Recent guidelines have recommended universal screening of all pregnant women to identify those colonized with GBS and administration of peripartum prophylaxis to those identified as carriers to reduce the risk of early-onset GBS disease in neonates. Enriched culture methods are the current standard for prenatal GBS screening; however, the implementation of more sensitive molecular diagnostic tests may be able to further reduce the risk of early-onset GBS infection. We report a clinical evaluation of the Xpert GBS LB assay, a molecular diagnostic test for the identification of GBS from broth-enriched vaginal/rectal specimens obtained during routine prenatal screening. A total of 826 specimens were collected from women undergoing prenatal screening (35 to 37 weeks' gestation) and tested at one of three clinical centers. Each swab specimen was tested directly prior to enrichment using the Xpert GBS assay. Following 18 to 24 h of broth enrichment, each specimen was tested using the Xpert GBS LB assay and the FDA-cleared Smart GBS assay as a molecular diagnostic comparator. Results obtained using all three molecular tests were compared to those for broth-enriched culture as the gold standard. The sensitivity and specificity of the Xpert GBS LB assay were 99.0% and 92.4%, respectively, compared to those for the gold standard culture. The Smart GBS molecular test demonstrated sensitivity and specificity of 96.8% and 95.5%, respectively. The sensitivities of the two broth-enriched molecular methods were superior to those for direct testing of specimens using the Xpert GBS assay, which demonstrated sensitivity and specificity of 85.7% and 96.2%, respectively.


Assuntos
Técnicas Bacteriológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Complicações Infecciosas na Gravidez/diagnóstico , Diagnóstico Pré-Natal/métodos , Infecções Estreptocócicas/diagnóstico , Streptococcus agalactiae/isolamento & purificação , Feminino , Humanos , Recém-Nascido , Gravidez , Complicações Infecciosas na Gravidez/microbiologia , Reto/microbiologia , Sensibilidade e Especificidade , Infecções Estreptocócicas/microbiologia , Vagina/microbiologia
20.
J Clin Microbiol ; 53(7): 2365-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25972419

RESUMO

We evaluated the clinical performance (sensitivity and specificity) of the AmpliVue group A Streptococcus (GAS) isothermal helicase-dependent amplification assay using 1,192 pharyngeal swab specimens. AmpliVue GAS assay results were compared to the results of routine throat cultures on selective streptococcal blood agar plates. The sensitivity and specificity of the AmpliVue GAS assay were 98.3% (95% confidence interval [CI], 95 to 100%) and 93.2% (95% CI, 91 to 95%), respectively.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Faringe/microbiologia , Infecções Estreptocócicas/diagnóstico , Streptococcus pyogenes/isolamento & purificação , Humanos , Sensibilidade e Especificidade , Streptococcus pyogenes/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA