Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cell Physiol ; 239(5): e31198, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38451745

RESUMO

Liver sinusoidal endothelial cells (LSECs) dysfunction is a key process in the development of chronic liver disease (CLD). Progressive scarring increases liver stiffness in a winch-like loop stimulating a dysfunctional liver cell phenotype. Cellular stretching is supported by biomechanically modulated molecular factors (BMMFs) that can translocate into the cytoplasm to support mechanotransduction through cytoskeleton remodeling and gene transcription. Currently, the molecular mechanisms of stiffness-induced LSECs dysfunction remain largely unclear. Here we propose calcium- and integrin-binding protein 1 (CIB1) as BMMF with crucial role in LSECs mechanobiology in CLD. CIB1 expression and translocation was characterized in healthy and cirrhotic human livers and in LSECs cultured on polyacrylamide gels with healthy and cirrhotic-like stiffnesses. Following the modulation of CIB1 with siRNA, the transcriptome was scrutinized to understand downstream effects of CIB1 downregulation. CIB1 expression is increased in LSECs in human cirrhosis. In vitro, CIB1 emerges as an endothelial BMMF. In human umbilical vein endothelial cells and LSECs, CIB1 expression and localization are modulated by stiffness-induced trafficking across the nuclear membrane. LSECs from cirrhotic liver tissue both in animal model and human disease exhibit an increased amount of CIB1 in cytoplasm. Knockdown of CIB1 in LSECs exposed to high stiffness improves LSECs phenotype by regulating the intracellular tension as well as the inflammatory response. Our results demonstrate that CIB1 is a key factor in sustaining cellular tension and stretching in response to high stiffness. CIB1 downregulation ameliorates LSECs dysfunction, enhancing their redifferentiation, and reducing the inflammatory response.


Assuntos
Proteínas de Ligação ao Cálcio , Células Endoteliais , Cirrose Hepática , Fígado , Mecanotransdução Celular , Animais , Humanos , Masculino , Proteínas de Ligação ao Cálcio/metabolismo , Proteínas de Ligação ao Cálcio/genética , Células Cultivadas , Células Endoteliais/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo , Fígado/metabolismo , Cirrose Hepática/metabolismo , Cirrose Hepática/patologia , Cirrose Hepática/genética , Feminino , Ratos , Ratos Sprague-Dawley
2.
Surg Endosc ; 38(7): 3758-3772, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38789623

RESUMO

BACKGROUND: Hyperspectral imaging (HSI), combined with machine learning, can help to identify characteristic tissue signatures enabling automatic tissue recognition during surgery. This study aims to develop the first HSI-based automatic abdominal tissue recognition with human data in a prospective bi-center setting. METHODS: Data were collected from patients undergoing elective open abdominal surgery at two international tertiary referral hospitals from September 2020 to June 2021. HS images were captured at various time points throughout the surgical procedure. Resulting RGB images were annotated with 13 distinct organ labels. Convolutional Neural Networks (CNNs) were employed for the analysis, with both external and internal validation settings utilized. RESULTS: A total of 169 patients were included, 73 (43.2%) from Strasbourg and 96 (56.8%) from Verona. The internal validation within centers combined patients from both centers into a single cohort, randomly allocated to the training (127 patients, 75.1%, 585 images) and test sets (42 patients, 24.9%, 181 images). This validation setting showed the best performance. The highest true positive rate was achieved for the skin (100%) and the liver (97%). Misclassifications included tissues with a similar embryological origin (omentum and mesentery: 32%) or with overlaying boundaries (liver and hepatic ligament: 22%). The median DICE score for ten tissue classes exceeded 80%. CONCLUSION: To improve automatic surgical scene segmentation and to drive clinical translation, multicenter accurate HSI datasets are essential, but further work is needed to quantify the clinical value of HSI. HSI might be included in a new omics science, namely surgical optomics, which uses light to extract quantifiable tissue features during surgery.


Assuntos
Aprendizado Profundo , Imageamento Hiperespectral , Humanos , Estudos Prospectivos , Imageamento Hiperespectral/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Abdome/cirurgia , Abdome/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
3.
Liver Transpl ; 29(11): 1226-1233, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37728488

RESUMO

An ischemia-reperfusion injury (IRI) results from a prolonged ischemic insult followed by the restoration of blood perfusion, being a common cause of morbidity and mortality, especially in liver transplantation. At the maximum of the potential damage, IRI is characterized by 2 main phases. The first is the ischemic phase, where the hypoxia and vascular stasis induces cell damage and the accumulation of damage-associated molecular patterns and cytokines. The second is the reperfusion phase, where the local sterile inflammatory response driven by innate immunity leads to a massive cell death and impaired liver functionality. The ischemic time becomes crucial in patients with underlying pathophysiological conditions. It is possible to compare this process to a shooting gun, where the loading trigger is the ischemia period and the firing shot is the reperfusion phase. In this optic, this article aims at reviewing the main ischemic events following the phases of the surgical timeline, considering the consequent reperfusion damage.


Assuntos
Hepatopatias , Transplante de Fígado , Traumatismo por Reperfusão , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Fígado/irrigação sanguínea , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/metabolismo , Hepatopatias/metabolismo , Imunidade Inata
4.
J Magn Reson Imaging ; 57(3): 918-927, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35852296

RESUMO

BACKGROUND: MRI is the reference for the diagnosis of arterial cerebral ischemia, but its role in acute mesenteric ischemia (AMI) is poorly known. PURPOSE: To assess MRI detection of early ischemic bowel lesions in a porcine model of arterial AMI. STUDY TYPE: Prospective/cohort. ANIMAL MODEL: Porcine model of arterial AMI obtained by embolization of the superior mesenteric artery (seven pigs). FIELD STRENGTH/SEQUENCE: A 5-T. T1 gradient-echo-weighted-imaging (WI), half-Fourier-acquisition-single-shot-turbo-spin-echo, T2 turbo-spin-echo, true-fast-imaging-with-steady-precession (True-FISP), diffusion-weighted-echo-planar (DWI). ASSESSMENT: T1-WI, T2-WI, and DWI were performed before and continuously after embolization for 6 hours. The signal intensity (SI) of the ischemic bowel was assessed visually and quantitatively on all sequences. The apparent diffusion coefficient (ADC) was assessed. STATISTICAL TESTS: Paired Student's t-test or Mann-Whitney U-test, significance at P < 0.05. RESULTS: One pig died from non-AMI-related causes. The remaining pigs underwent a median 5 h53 (range 1 h24-6 h01) of ischemia. Visually, the ischemic bowel showed signal hyperintensity on DWI-b800 after a median 85 (57-276) minutes compared to the nonischemic bowel. DWI-b800 SI significantly increased after 2 hours (+19%) and the ADC significant decrease within the first hour (-31%). The ischemic bowel was hyperintense on precontrast T1-WI after a median 87 (70-171) minutes with no significant quantitative changes over time (P = 0.46-0.93). The ischemic bowel was hyperintense on T2-WI in three pigs with a significant SI increase on True-FISP after 1 and 2 hours. DATA CONCLUSION: Changes in SI and ADC can be seen early after the onset of arterial AMI with DWI. The value of T2-WI appears to be limited. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Isquemia Mesentérica , Animais , Suínos , Isquemia Mesentérica/diagnóstico por imagem , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Isquemia/diagnóstico por imagem , Isquemia/patologia , Imagem de Difusão por Ressonância Magnética/métodos
5.
Int J Mol Sci ; 23(15)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35955482

RESUMO

The interaction between the mitochondria and the endoplasmic reticulum (ER) is essential for hepatocyte function. An increase in ER-mitochondria contacts (ERMCs) is associated with various metabolic diseases. Non-alcoholic fatty liver disease (NAFLD) is associated with obesity and type 2 diabetes, and its progressive form non-alcoholic steatohepatitis (NASH) can lead to cirrhosis and hepatocellular carcinoma. However, the role of ERMCs in the progression of NAFL to NASH is still unclear. We assessed whether ERMCs could correlate with NAFLD severity. We used a proximity ligation assay to measure the abundance of ERMCs in liver biopsies from patients with biopsy-proven NAFLD (n = 48) and correlated the results with histological and metabolic syndrome (MetS) features. NAFLD patients were included according to inclusion and exclusion criteria, and then assigned to NAFL (n = 9) and NASH (n = 39) groups. ERMCs density could discriminate NASH from NAFL (sensitivity 61.5%, specificity 100%). ERMCs abundance correlated with hepatocellular ballooning. Moreover, the density of ERMCs increased with an increase in the number of MetS features. In conclusion, ERMCs increased from NAFL to NASH, in parallel with the number of MetS features, supporting a role for this interaction in the pathophysiology of NASH.


Assuntos
Diabetes Mellitus Tipo 2 , Neoplasias Hepáticas , Síndrome Metabólica , Hepatopatia Gordurosa não Alcoólica , Diabetes Mellitus Tipo 2/metabolismo , Retículo Endoplasmático/metabolismo , Humanos , Fígado/metabolismo , Neoplasias Hepáticas/metabolismo , Síndrome Metabólica/metabolismo , Mitocôndrias/patologia , Hepatopatia Gordurosa não Alcoólica/metabolismo
6.
Minim Invasive Ther Allied Technol ; 31(3): 342-349, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33000653

RESUMO

BACKGROUND: Urethral injury is a dreaded complication during laparoscopic, perineal and transanal surgery and is mainly a result of a failed visualization of the urethra. The aim of this systematic review is to provide an overview of the available literature on the near-infrared fluorescence (NIRF) imaging technique using contrast agents for the intra-operative visualization of the urethra. MATERIAL AND METHODS: A systematic review of the literature was conducted including studies on NIRF imaging using contrast agents to visualize the urethra. All studies describing a NIRF imaging technique and demonstrating visual findings of the urethra were included. RESULTS: Five studies were identified. Four studies examined indocyanine green, one of which also studied the IRDye® 800BK agent and one examined the CP-IRT dye. All studies showed that the NIRF imaging technique was feasible for an early identification of the urethra. No complications related to NIRF imaging were reported. CONCLUSION: We conclude that the use of a NIRF imaging technique is feasible and that it can contribute to prevent iatrogenic injury to the urethra. However, based on the limited available data, no solid conclusion can yet be drawn and further translation to the clinical practice is necessary.


Assuntos
Laparoscopia , Uretra , Corantes Fluorescentes , Humanos , Verde de Indocianina , Laparoscopia/métodos , Masculino , Imagem Óptica/métodos , Uretra/diagnóstico por imagem , Uretra/cirurgia
7.
HPB (Oxford) ; 24(11): 1832-1843, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35794053

RESUMO

BACKGROUND: Gastroenteropancreatic neuroendocrine tumors are often diagnosed when metastatic. The liver is the main site of metastases. Unfortunately, optimal management of neuroendocrine liver metastases remains a topic of debate. The aim of this study was to make a systematic review of the current literature about the results of the different treatments of neuroendocrine liver metastases. METHODS: A systematic review was conducted for English language publications from 1995 to 2021. Outcomes were analyzed according to survival, disease-free survival, and in the case of systemic therapies, progression-free survival. RESULTS: 5509 patients were analyzed in the review. 67% of patients underwent surgery achieving 5 years overall survival despite only 30% percent without a recurrence. 60% of patients that had received a transplant reached 5 years survival with a low disease-free survival rate (20%). Five-year survival rate was 36.2% for patients undergoing loco-regional therapies. CONCLUSION: Surgical resection is the best treatment when metastases are resectable, with the highest rate of survival, although liver transplantation shows good results for patients not eligible for surgery. Loco-regional therapies may be useful when surgical resection is contraindicated, or selectively used as a bridge to surgery or transplantation. Systemic therapies are indicated in patients for whom curative treatment cannot be obtained.


Assuntos
Neoplasias Intestinais , Neoplasias Hepáticas , Transplante de Fígado , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Tumores Neuroendócrinos/cirurgia , Neoplasias Hepáticas/cirurgia , Neoplasias Intestinais/patologia , Neoplasias Pancreáticas/patologia
8.
Surg Endosc ; 35(4): 1844-1850, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32342212

RESUMO

BACKGROUND: Clinical evaluation of the demarcation line separating ischemic from non-ischemic liver parenchyma may be challenging. Hyperspectral imaging (HSI) is a noninvasive imaging modality, which combines a camera with a spectroscope and allows quantitative imaging of tissue oxygenation. Our group developed a software to overlay HSI images onto the operative field, obtaining HSI-based enhanced reality (HYPER). The aim of the present study was to evaluate the accuracy of HYPER to identify the demarcation line after a left vascular inflow occlusion during an anatomical left hepatectomy. MATERIALS AND METHODS: In the porcine model (n = 3), the left branches of the hepatic pedicle were ligated. Before and after vascular occlusion, HSI images based on tissue oxygenation (StO2), obtained through the Near-Infrared index (NIR index), were regularly acquired and superimposed onto RGB video. The demarcation line was marked on the liver surface with electrocautery according to HYPER. Local lactates were measured on blood samples from the liver surface in both ischemic and perfused segments using a strip-based device. At the same areas, confocal endomicroscopy was performed. RESULTS: After ligation, HSI demonstrated a significantly lower oxygenation (NIR index) in the left medial lobe (LML) (0.27% ± 0.21) when compared to the right medial lobe (RML) (58.60% ± 12.08; p = 0.0015). Capillary lactates were significantly higher (3.07 mmol/L ± 0.84 vs. 1.33 ± 0.71 mmol/L; p = 0.0356) in the LML versus RML, respectively. Concordantly, confocal videos demonstrated the absence of blood flow in the LML and normal perfusion in the RML. CONCLUSIONS: HYPER has made it possible to correctly identify the demarcation line and quantify surface liver oxygenation. HYPER could be an intraoperative tool to guide perfusion-based demarcation line assessment and segmentation.


Assuntos
Fígado/diagnóstico por imagem , Fígado/cirurgia , Análise Espectral , Animais , Diagnóstico por Imagem , Hepatectomia , Suínos
9.
Surg Endosc ; 35(8): 4840-4848, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32860134

RESUMO

BACKGROUND: IRDye® 800BK is a fluorophore, currently undergoing clinical translation, which has both biliary and renal clearance. To date, there is no description of a fluorophore, which can be simultaneously used for non-invasive, near-infrared fluorescence-based (NIRF) visualization of different structures and perfusion evaluation. The purpose of this study was to evaluate IRDye® 800BK for the simultaneous assessment of bowel perfusion, lymphography, ureter and bile duct delineation. METHODS: Six pigs received a 0.15 mg/kg dye as a single bolus intravenous injection (IV). With the FLER (fluorescence-based enhanced reality) software, fluorescence intensity (FI) of 5 regions of interest (ROI) in an ischemic bowel loop was measured along with the time to reach the FI peak, and capillary lactate was measured from the same ROI, followed by the assessment of the ureters and bile ducts for a maximal duration of 180 min after dye administration. In 3 animals, the procedure was initiated via gastroscopic injection of a 0.6 mg (1 mg/mL) dye in the gastric submucosa followed by lymphography in a NIRF setting. RESULTS: Excellent visualization of the ureters and bowel perfusion was obtained under NIRF imaging. Additionally, the bile duct and gastric lymph ducts and nodes were visualized. A positive correlation was found between the time to peak FI in the ischemic bowel loop and the corresponding capillary lactate levels (rho 0.59, p < 0.001). CONCLUSION: In this study, we successfully demonstrated the simultaneous multipurpose IRDye® 800BK applicability during laparoscopic surgery. This fluorophore has the potential to become a powerful and versatile image-guided surgery tool.


Assuntos
Laparoscopia , Cirurgia Assistida por Computador , Ureter , Animais , Fluorescência , Corantes Fluorescentes , Verde de Indocianina , Imagem Óptica , Suínos , Ureter/diagnóstico por imagem , Ureter/cirurgia
10.
Surg Endosc ; 35(9): 5115-5123, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32989536

RESUMO

BACKGROUND: Intraoperative localization of endoluminal lesions is can be difficult during laparoscopy. Preoperative endoscopic marking is therefore necessary. Current methods include submucosal tattooing using visible dyes, which in case of transmural injection can impair surgical dissection. Tattooing using indocyanine green (ICG) coupled to intraoperative near-infrared (NIR) laparoscopy has been described. ICG is only visible under NIR-light, therefore, it doesn't impair the surgical workflow under white light even if there is spillage. However, ICG tattoos have rapid diffusion and short longevity. We propose fluorescent over-the-scope clips (FOSC), using a novel biocompatible fluorescent paint, as durable lesion marking. METHODS: In six pigs, gastric and colonic endoscopic tattoos using 0.05 mg/mL of ICG and markings using the fluorescent OSC were performed (T0). Simultaneously, NIR laparoscopy was executed. Follow-up laparoscopies were conducted at postoperative day (POD) 4-6 (T1) and POD 11-12 (T2). During laparoscopy, fluorescence intensity was assessed. In one human cadaver, FOSC was used to mark a site on the stomach and on the sigmoid colon, respectively. Intraoperative detection during NIR laparoscopy was assessed. RESULTS: Gastric and colonic ICG tattooing and OSC markings were easily visible using NIR laparoscopy on T0. All FOSC were visible at T1 and T2 in both stomach and colon, whereas the ICG tattooing at T1 was only visible in the stomach of 2 animals and in the colon of 3 animals. At T2, tattoos were not visible in any animal. FOSC were still visible in both stomach and colon of the human cadaver at 10 days. CONCLUSION: Endoscopic marking using FOSC can be an efficient and durable alternative to standard methods.


Assuntos
Laparoscopia , Tatuagem , Animais , Corantes , Fluorescência , Trato Gastrointestinal , Verde de Indocianina , Suínos
11.
Surg Endosc ; 35(10): 5827-5835, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33026514

RESUMO

INTRODUCTION/OBJECTIVE: Gastric conduit (GC) is used for reconstruction after esophagectomy. Anastomotic leakage (AL) incidence remains high, given the extensive disruption of the gastric circulation. Currently, there is no reliable method to intraoperatively quantify gastric perfusion. Hyperspectral imaging (HSI) has shown its potential to quantify serosal StO2. Confocal laser endomicroscopy (CLE) allows for automatic mucosal microcirculation quantification as functional capillary density area (FCD-A). The aim of this study was to quantify serosal and mucosal GC's microperfusion using HSI and CLE. Local capillary lactate (LCL) served as biomarker. METHODS: GC was formed in 5 pigs and serosal StO2% was quantified at 3 regions of interest (ROI) using HSI: fundus (ROI-F), greater curvature (ROI-C), and pylorus (ROI-P). After intravenous injection of sodium-fluorescein (0.5 g), CLE-based mucosal microperfusion was assessed at the corresponding ROIs, and LCLs were quantified via a lactate analyzer. RESULTS: StO2 and FCD-A at ROI-F (41 ± 10.6%, 3.3 ± 3.8, respectively) were significantly lower than ROI-C (68.2 ± 6.7%, p value: 0.005; 18.4 ± 7, p value: 0.01, respectively) and ROI-P (72 ± 10.4%, p value: 0.005; 15.7 ± 3.2 p value: 0.001). LCL value at ROI-F (9.6 ± 4.7 mmol/L) was significantly higher than at ROI-C (2.6 ± 1.2 mmol/L, p value: 0.04) and ROI-P (2.6 ± 1.3 mmol/L, p value: 0.04). No statistically significant difference was found in all metrics between ROI-C and ROI-P. StO2 correlated with FCD-A (Pearson's r = 0.67). The LCL correlated negatively with both FCD-A (Spearman's r = - 0.74) and StO2 (Spearman's r = - 0.54). CONCLUSIONS: GC formation causes a drop in serosal and mucosal fundic perfusion. HSI and CLE correlate well and might become useful intraoperative tools.


Assuntos
Esofagectomia , Estômago , Fístula Anastomótica , Animais , Imagem Óptica , Perfusão , Estômago/diagnóstico por imagem , Estômago/cirurgia , Suínos
12.
Surg Endosc ; 35(12): 7142-7153, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33492508

RESUMO

BACKGROUND: Anastomotic leakage (AL) is one of the dreaded complications following surgery in the digestive tract. Near-infrared fluorescence (NIRF) imaging is a means to intraoperatively visualize anastomotic perfusion, facilitating fluorescence image-guided surgery (FIGS) with the purpose to reduce the incidence of AL. The aim of this study was to analyze the current practices and results of NIRF imaging of the anastomosis in digestive tract surgery through the EURO-FIGS registry. METHODS: Analysis of data prospectively collected by the registry members provided patient and procedural data along with the ICG dose, timing, and consequences of NIRF imaging. Among the included upper-GI, colorectal, and bariatric surgeries, subgroup analysis was performed to identify risk factors associated with complications. RESULTS: A total of 1240 patients were included in the study. The included patients, 74.8% of whom were operated on for cancer, originated from 8 European countries and 30 hospitals. A total of 54 surgeons performed the procedures. In 83.8% of cases, a pre-anastomotic ICG dose was administered, and in 60.1% of cases, a post-anastomotic ICG dose was administered. A significant difference (p < 0.001) was found in the ICG dose given in the four pathology groups registered (range: 0.013-0.89 mg/kg) and a significant (p < 0.001) negative correlation was found between the ICG dose and BMI. In 27.3% of the procedures, the choice of the anastomotic level was guided by means of NIRF imaging which means that in these cases NIRF imaging changed the level of anastomosis which was first decided based on visual findings in conventional white light imaging. In 98.7% of the procedures, the use of ICG partly or strongly provided a sense of confidence about the anastomosis. A total of 133 complications occurred, without any statistical significance in the incidence of complications in the anastomoses, whether they were ICG-guided or not. CONCLUSION: The EURO-FIGS registry provides an insight into the current clinical practice across Europe with respect to NIRF imaging of anastomotic perfusion during digestive tract surgery.


Assuntos
Verde de Indocianina , Cirurgia Assistida por Computador , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Humanos , Perfusão , Sistema de Registros
13.
Sensors (Basel) ; 21(2)2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33477656

RESUMO

This work presents the potential of hyperspectral imaging (HSI) to monitor the thermal outcome of laser ablation therapy used for minimally invasive tumor removal. Our main goal is the establishment of indicators of the thermal damage of living tissues, which can be used to assess the effect of the procedure. These indicators rely on the spectral variation of temperature-dependent tissue chromophores, i.e., oxyhemoglobin, deoxyhemoglobin, methemoglobin, and water. Laser treatment was performed at specific temperature thresholds (from 60 to 110 °C) on in-vivo animal liver and was assessed with a hyperspectral camera (500-995 nm) during and after the treatment. The indicators were extracted from the hyperspectral images after the following processing steps: the breathing motion compensation and the spectral and spatial filtering, the selection of spectral bands corresponding to specific tissue chromophores, and the analysis of the areas under the curves for each spectral band. Results show that properly combining spectral information related to deoxyhemoglobin, methemoglobin, lipids, and water allows for the segmenting of different zones of the laser-induced thermal damage. This preliminary investigation provides indicators for describing the thermal state of the liver, which can be employed in the future as clinical endpoints of the procedure outcome.


Assuntos
Terapia a Laser , Lasers , Animais , Luz , Fígado/diagnóstico por imagem , Temperatura
14.
Sensors (Basel) ; 21(20)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34696147

RESUMO

Thermal ablation is an acceptable alternative treatment for primary liver cancer, of which laser ablation (LA) is one of the least invasive approaches, especially for tumors in high-risk locations. Precise control of the LA effect is required to safely destroy the tumor. Although temperature imaging techniques provide an indirect measurement of the thermal damage, a degree of uncertainty remains about the treatment effect. Optical techniques are currently emerging as tools to directly assess tissue thermal damage. Among them, hyperspectral imaging (HSI) has shown promising results in image-guided surgery and in the thermal ablation field. The highly informative data provided by HSI, associated with deep learning, enable the implementation of non-invasive prediction models to be used intraoperatively. Here we show a novel paradigm "peak temperature prediction model" (PTPM), convolutional neural network (CNN)-based, trained with HSI and infrared imaging to predict LA-induced damage in the liver. The PTPM demonstrated an optimal agreement with tissue damage classification providing a consistent threshold (50.6 ± 1.5 °C) for the damage margins with high accuracy (~0.90). The high correlation with the histology score (r = 0.9085) and the comparison with the measured peak temperature confirmed that PTPM preserves temperature information accordingly with the histopathological assessment.


Assuntos
Aprendizado Profundo , Terapia a Laser , Imageamento Hiperespectral , Lasers , Redes Neurais de Computação
15.
Surg Radiol Anat ; 43(9): 1413-1420, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34117902

RESUMO

PURPOSE: The hepato-mesenteric trunk is an extremely rare condition in which the common hepatic artery (CHA) originates from the superior mesenteric artery (SMA). Usually, CHA passes behind the head of the pancreas. A systematic review was performed to provide guidelines for the perioperative management of patients with this anatomical variation who underwent a pancreaticoduodenectomy (PD). A case report was also included. METHODS: A systematic search of the literature was conducted and the manuscript was structured following point-by-point the PRISMA guidelines. The risk of bias within individual studies was assessed using the Joanna Briggs Institute Critical Appraisal Checklist tools. Case report was structured according to the CARE guidelines. RESULTS: After an initial selection of 141 titles, 9 articles were included in the study (n = 10 patients). A postoperative surgical complication which required a reintervention occurred only one time. In four patients, CHA had a posterior position relative to pancreas, while in three cases, it was anterior. The remaining three patients had an intrapancreatic course. The CHA was resected in two patients, with an end-to-end reconstruction or using the splenic artery stump. In only three patients, a preoperative multidisciplinary presentation was performed and in four cases, the CHA variation was not described by radiologists in formal CT-scan reports. CONCLUSION: Although there are no definitive guidelines, improvements in the preoperative knowledge of such a rare anatomical variation may ensure better postoperative outcomes, avoiding intraoperative accidents and life-threatening postoperative complications.


Assuntos
Variação Anatômica , Artéria Hepática/anatomia & histologia , Artéria Mesentérica Superior/anatomia & histologia , Pancreaticoduodenectomia , Humanos , Complicações Pós-Operatórias/prevenção & controle
16.
HPB (Oxford) ; 23(7): 994-999, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33431265

RESUMO

BACKGROUND: Sickle cell disease is a group of autosomal recessive disorders characterised by haemolytic anaemia. Liver is one of the most affected organs, ranging from liver tests alterations to acute liver failure for which liver transplantation is the only life-saving treatment. METHODS: This study aims to make a systematic review of the current literature to evaluate indications, timing, and results of liver transplantation for patients affected by SCD. RESULTS: Twenty-nine patients in total were reported worldwide until 2018, the average patient age is 28.7 (0.42-56), all patients have a pre-transplant diagnosis of SCD. Cirrhosis at transplantation was present in six-teen (n = 16, 55.1%) patients. In ten patients (n = 10, 34.5%), acute liver failure arises from healthy liver and presented sickle cell intrahepatic cholestasis. Eleven patients (n = 11, 39.2%) died, three (n = 3, 10.7%) in the first postoperative month, and seven (n = 7, 25%) in the first year. Mean follow-up was 27 months (range: 7-96), one-year overall survival was 48.7%. DISCUSSION: Liver transplantation for SCD has been increasingly reported with encouraging results. Indications are presently reserved for acute liver failure arising both in healthy liver and end-stage liver disease.


Assuntos
Anemia Falciforme , Doença Hepática Terminal , Transplante de Fígado , Anemia Falciforme/diagnóstico , Anemia Falciforme/cirurgia , Humanos , Cirrose Hepática , Transplante de Fígado/efeitos adversos
17.
Small ; 16(43): e1907308, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32940007

RESUMO

Redox regulation has recently been proposed as a critical intracellular mechanism affecting cell survival, proliferation, and differentiation. Redox homeostasis has also been implicated in a variety of degenerative neurological disorders such as Parkinson's and Alzheimer's disease. In fact, it is hypothesized that markers of oxidative stress precede pathologic lesions in Alzheimer's disease and other neurodegenerative diseases. Several therapeutic approaches have been suggested so far to improve the endogenous defense against oxidative stress and its harmful effects. Among such approaches, the use of artificial antioxidant systems has gained increased popularity as an effective strategy. Nanoscale drug delivery systems loaded with enzymes, bioinspired catalytic nanoparticles and other nanomaterials have emerged as promising candidates. The development of degradable hydrogels scaffolds with antioxidant effects could also enable scientists to positively influence cell fate. This current review summarizes nanobiomaterial-based approaches for redox regulation and their potential applications as central nervous system neurodegenerative disease treatments.


Assuntos
Doença de Alzheimer , Doenças Neurodegenerativas , Antioxidantes , Humanos , Doenças Neurodegenerativas/tratamento farmacológico , Oxirredução , Estresse Oxidativo
18.
Surg Innov ; 27(5): 424-430, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32886583

RESUMO

Anatomical liver resection (ALR) is the preferred oncological approach for the treatment of primary liver malignancies, such as hepatocellular carcinoma and intrahepatic cholangiocarcinoma. The demarcation line (DL) is formed by means of selective vascular occlusion and is used by surgeons to guide ALR. Emerging intraoperative technologies are playing a major role to enhance the surgeon's vision and ensure a precise oncologic surgery. In this article, a brief overview of modalities to assess the DL during ALRs is presented, from the established conventional techniques to future perspectives.


Assuntos
Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Carcinoma Hepatocelular/cirurgia , Colangiocarcinoma/cirurgia , Hepatectomia , Humanos , Verde de Indocianina , Neoplasias Hepáticas/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA