Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Analyst ; 145(3): 983-991, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-31829323

RESUMO

The development of viable point-of-care diagnostic formats is integral to achieving better patient care and improved outcomes. The need for robust and low-cost tests is especially important in under-resourced and rural settings. Perhaps the greatest challenge is ensuring that an untrained individual is capable of operating and interpreting the test, out with a care facility. Here we present a paper-based diagnostic device capable of sensing miR-29a using both colorimetric and surface enhanced Raman scattering (SERS) analysis. Rather, than carry out the two types of analyses in tandem, we envisage that the colorimetric output is easy enough to be interpreted by the untrained-individual administering the test to provide them with qualitative feedback. If deemed positive, the test can be further validated at a centralized care facility using a handheld-Raman spectrometer to provide a semi-quantitative result. Detection of miR-29a, a microRNA associated with myocardial infarction, was achieved at a level of pg µL-1 through the combination of three-dimensional paper-based microfluidics, colorimetric detection, and surface enhanced Raman scattering (SERS) analysis. RGB analysis of the colorimetric output generated from samples containing miR-29a at different concentrations (18-360 pg µL-1) showed differentiation from the control sample, however significant repeat variability indicated that it could not be used for quantifying miR-29a levels. However, the SERS analysis exhibited greater reproducibility at varying concentrations, achieving an LoD of 47 pg µL-1. The union of the paper-based device and the two analysis methods resulted in the production of a sensitive, reproducible and facile, point of care test (POCT), which paves the way for future implementation in the diagnosis of a range of diseases.


Assuntos
MicroRNAs/análise , Microfluídica/métodos , Papel , Ouro/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , MicroRNAs/química , Microfluídica/instrumentação , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/genética , Testes Imediatos , Corantes de Rosanilina/química , Análise Espectral Raman
2.
Anal Chem ; 89(11): 5654-5664, 2017 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-28406607

RESUMO

While a number of assays for soluble analytes have been developed using paper-based microfluidic devices, the detection and analysis of blood cells has remained an outstanding challenge. In this Feature, we discuss how the properties of paper determine the performance of paper-based microfluidic devices and permit the design of cellular assays, which can ultimately impact disparities in healthcare that exist in limited-resource settings.

3.
J Phys Chem A ; 117(44): 11167-82, 2013 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-24168810

RESUMO

The reaction of trinitrotoluene (TNT) with bases has been investigated by NMR and visible spectroscopy methods. Hydroxide ion was found to react in one of two ways, either by deprotonation of the methyl group or by nucleophilic attack on the aromatic ring to form a σ adduct. The rate of each mode of reaction depends upon the polarity of the solvent. In tetrahydrofuran (THF), σ adduct formation is rapid and the long-term equilibrium product is deprotonation of the methyl group. When the solvent is methanol (MeOH), the two reactions have similar rates and the σ adduct becomes the majority product. Amines were found to be ineffective in directly deprotonating TNT or in forming σ adducts. Rather, the amines react with ambient water to generate hydroxide ion, which then reacts with TNT. The solvent choice and water content are crucial to understanding the reactivity of bases with TNT. To assist in the interpretation of the experimental results, computational analysis was performed at the B3LYP/6-311+G**//HF/6-311+G** level to determine the thermodynamics of the reactions of TNT. The SM8 implicit solvation model was applied to converged geometries and suggested a strong solvation effect upon product formation. Thermodynamic analysis suggested a significant preference of alkoxide or hydroxide attack versus amine attack in any modeled dielectric, consistent with the experimental observations.

4.
J Phys Chem A ; 117(2): 324-32, 2013 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-23237202

RESUMO

Trinitrobenzene (TNB) and trinitrotoluene (TNT) react in N,N-dimethylformamide (DMF) to form multiple species in solution. Despite structural similarities, electronic spectra show that the reactivity is different for TNB and TNT. In addition to reaction with the DMF solvent, residual water in nominally dry DMF generates sufficient hydroxide for reaction with TNB and TNT. Multiple sigma adducts are formed and observed to be fluorescent, which has not been previously reported. Both TNB and TNT show the capacity to form sigma adducts with hydroxide and DMF, while methyl hydrogens of TNT can be deprotonated by hydroxide.

5.
Nat Commun ; 12(1): 1931, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33771993

RESUMO

The COVID-19 pandemic continues to have an unprecedented impact on societies and economies worldwide. There remains an ongoing need for high-performance SARS-CoV-2 tests which may be broadly deployed for infection monitoring. Here we report a highly sensitive single molecule array (Simoa) immunoassay in development for detection of SARS-CoV-2 nucleocapsid protein (N-protein) in venous and capillary blood and saliva. In all matrices in the studies conducted to date we observe >98% negative percent agreement and >90% positive percent agreement with molecular testing for days 1-7 in symptomatic, asymptomatic, and pre-symptomatic PCR+ individuals. N-protein load decreases as anti-SARS-CoV-2 spike-IgG increases, and N-protein levels correlate with RT-PCR Ct-values in saliva, and between matched saliva and capillary blood samples. This Simoa SARS-CoV-2 N-protein assay effectively detects SARS-CoV-2 infection via measurement of antigen levels in blood or saliva, using non-invasive, swab-independent collection methods, offering potential for at home and point of care sample collection.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Proteínas do Nucleocapsídeo de Coronavírus/sangue , SARS-CoV-2/metabolismo , Saliva/virologia , COVID-19/epidemiologia , COVID-19/virologia , Proteínas do Nucleocapsídeo de Coronavírus/genética , Epidemias , Serviços de Assistência Domiciliar , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Curva ROC , SARS-CoV-2/genética , SARS-CoV-2/fisiologia , Manejo de Espécimes/métodos
6.
J Vis Exp ; (121)2017 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-28362396

RESUMO

Paper wicks fluids autonomously due to capillary action. By patterning paper with hydrophobic barriers, the transport of fluids can be controlled and directed within a layer of paper. Moreover, stacking multiple layers of patterned paper creates sophisticated three-dimensional microfluidic networks that can support the development of analytical and bioanalytical assays. Paper-based microfluidic devices are inexpensive, portable, easy to use, and require no external equipment to operate. As a result, they hold great promise as a platform for point-of-care diagnostics. In order to properly evaluate the utility and analytical performance of paper-based devices, suitable methods must be developed to ensure their manufacture is reproducible and at a scale that is appropriate for laboratory settings. In this manuscript, a method to fabricate a general device architecture that can be used for paper-based immunoassays is described. We use a form of additive manufacturing (multi-layer lamination) to prepare devices that comprise multiple layers of patterned paper and patterned adhesive. In addition to demonstrating the proper use of these three-dimensional paper-based microfluidic devices with an immunoassay for human chorionic gonadotropin (hCG), errors in the manufacturing process that may result in device failures are discussed. We expect this approach to manufacturing paper-based devices will find broad utility in the development of analytical applications designed specifically for limited-resource settings.


Assuntos
Imageamento Tridimensional/métodos , Imunoensaio/métodos , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentação , Papel , Adesivos/química
7.
Lab Chip ; 16(19): 3689-94, 2016 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-27604182

RESUMO

The quantification of blood cells provides critical information about a patient's health status. Sophisticated analytical equipment, such as hematology analyzers, have been developed to perform these measurements, but limited-resource settings often lack the infrastructure required to purchase, operate, and maintain instrumentation. To address these practical challenges, paper-based microfluidic devices have emerged as a platform to develop diagnostic assays specifically for use at the point-of-care. To date, paper-based microfluidic devices have been used broadly in diagnostic assays that apply immunoassay, clinical chemistry, and electrochemistry techniques. The analysis of cells, however, has been largely overlooked. In this communication, we demonstrate a paper-based microfluidic device that enables the controlled transport of red blood cells (RBCs) and the measurement of the hematocrit-the ratio of RBC packed cell volume to total volume of whole blood. The properties of paper, device treatment, and device geometry affect the overall extent and reproducibility of transport of RBCs. Ultimately, we developed an inexpensive (US$0.03 per device) thermometer-styled device where the distance traveled by RBCs is proportional to the hematocrit. These results provide a foundation for the design of paper-based microfluidic devices that enable the separation and detection of cells in limited-resource settings.


Assuntos
Hematócrito/instrumentação , Dispositivos Lab-On-A-Chip , Papel , Desenho de Equipamento , Eritrócitos/citologia , Humanos , Plasma/citologia
8.
Lab Chip ; 14(24): 4653-8, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25300302

RESUMO

Diagnostic assays can provide valuable information about the health status of a patient, which include detection of biomarkers that indicate the presence of an infection, the progression or regression of a disease, and the efficacy of a course of treatment. Critical healthcare decisions must often be made at the point-of-care, far from the infrastructure and diagnostic capabilities of centralized laboratories. There exists an obvious need for diagnostic tools that are designed to address the unique challenges encountered by healthcare workers in limited-resource settings. Paper, a readily-available and inexpensive commodity, is an attractive medium with which to develop diagnostic assays for use in limited-resource settings. In this article, we describe a device architecture to perform immunoassays in patterned paper. These paper-based devices use a combination of lateral and vertical flow to control the wicking of fluid in three-dimensions. We provide guidelines to aid in the design of these devices and we illustrate how patterning can be used to tune the duration and performance of the assay. We demonstrate the use of these paper-based devices by developing a sandwich immunoassay for human chorionic gonadotropin (hCG) in urine, a biomarker of pregnancy. We then directly compare the qualitative and quantitative results of these paper-based immunoassays to commercially available lateral flow tests (i.e., the home pregnancy test). Our results suggest paper-based devices may find broad utility in the development of immunoassays for use at the point-of-care.


Assuntos
Gonadotropina Coriônica/urina , Papel , Sistemas Automatizados de Assistência Junto ao Leito , Gravidez/urina , Feminino , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA