Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Sci Technol ; 58(3): 1659-1668, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38198694

RESUMO

Historical practices at firefighter-training areas involved repeated aqueous film-forming foams (AFFFs) applications, resulting in source zones characterized by high concentrations of perfluoroalkyl and polyfluoroalkyl substances (PFAS). Repeated applications of AFFF composed of 14 anionic and 23 zwitterionic perfluoroalkyl substances (PFAS) were conducted on a single one-dimensional saturated soil column to quantify PFAS retention. An electrofluorination-based (3M) Milspec AFFF, which was above the mixture's critical micelle concentration (CMC), was at application strength (3%, v/v). Retention and retardation of PFAS mass increased with each successive AFFF addition, although the PFAS concentration profiles for subsequent applications differed from the initial. Greater degree of mass retention and retardation correlated with longer PFAS carbon-fluorine chain length and charged-headgroup type and as a function of AFFF application number. Anionic PFAS were increasingly retained with each subsequent AFFF application, while zwitterionic PFAS exhibited an alternating pattern of sorption and desorption. Surfactant-surfactant adsorption and competition during repeat AFFF applications that are at concentrations above the CMC resulted in adsorbed PFAS from the first application, changing the nature of the soil surface with preferential sorption of anionic PFAS and release of zwitterionic PFAS due to competitive elution. Applying a polyparameter quantitative structure-property relationship developed to describe sorption of AFFF-derived PFAS to uncontaminated, saturated soil was attempted for our experimental conditions. The model had been derived for data where AFFF is below the apparent CMC and our experimental conditions that included the presence of mixed micelles (aggregates consisting of different kinds of surfactants that exhibit characteristics properties different from micelles composed of a single surfactant) resulted in overall PFAS mass retained by an average of 27.3% ± 2.7% (standard error) above the predicted values. The correlation was significantly improved by adding a "micelle parameter" to account for cases where the applied AFFF was above the apparent CMC. Our results highlight the importance of interactions between the AFFF components that can only be investigated by employing complex PFAS mixtures at concentrations present in actual AFFF at application strength, which are above their apparent CMC. In firefighter-training areas (AFFF source zones), competitive desorption of PFAS may result in downgradient PFAS retention when desorbed PFAS become resorbed to uncontaminated soil.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Fluorocarbonos/análise , Micelas , Solo , Poluentes Químicos da Água/análise , Água , Tensoativos
2.
Environ Sci Technol ; 57(13): 5231-5242, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36947878

RESUMO

A comprehensive, generalized approach to predict the retention of per- and polyfluoroalkyl substances (PFAS) from aqueous film-forming foam (AFFF) by a soil matrix as a function of PFAS molecular and soil physiochemical properties was developed. An AFFF with 34 major PFAS (12 anions and 22 zwitterions) was added to uncontaminated soil in one-dimensional saturated column experiments and PFAS mass retained was measured. PFAS mass retention was described using an exhaustive statistical approach to generate a poly-parameter quantitative structure-property relationship (ppQSPR). The relevant predictive properties were PFAS molar mass, mass fluorine, number of nitrogens in the PFAS molecule, poorly crystalline Fe oxides, organic carbon, and specific (BET-N2) surface area. The retention of anionic PFAS was nearly independent of soil properties and largely a function of molecular hydrophobicity, with the size of the fluorinated side chain as the main predictor. Retention of nitrogen-containing zwitterionic PFAS was related to poorly crystalline metal oxides and organic carbon content. Knowledge of the extent to which a suite of PFAS may respond to variations in soil matrix properties, as developed here, paves the way for the development of reactive transport algorithms with the ability to capture PFAS dynamics in source zones over extended time frames.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Fluorocarbonos/análise , Solo , Poluentes Químicos da Água/análise , Minerais , Água , Carbono
3.
Environ Sci Technol ; 57(12): 4951-4958, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36917694

RESUMO

Exposures to per- and polyfluoroalkyl substances (PFAS) are of increasing concern. Assessments typically focus only on ingestion and inhalation exposure due to a lack of generally accepted approaches for estimating dermal absorption. Prior work indicates limited dermal absorption of ionic PFAS, but absorption of neutral PFAS has not been examined from the liquid vehicle or from vapor. Partitioning of semivolatile organic compounds from the gas phase to the skin surface (i.e., stratum corneum) is well known, but the potential for partitioning of neutral PFAS from the gas phase to the stratum corneum has yet to be estimated. The SPARC-estimated physicochemical properties were used to calculate transdermal permeability coefficients (kp_g) and dermal-to-inhalation (D/I) exposure ratios for two groups of neutral PFAS, including those on a U.S. Environmental Protection Agency PFAS list. 11 neutral PFAS gave calculated D/I ratios >5, indicating that direct transdermal absorption may be an important exposure pathway compared to inhalation. Data on consumer products or indoor air is needed for the 11 neutral PFAS, followed by possible biomonitoring to experimentally verify dermal absorption from air. Additional PFAS should be estimated by the protocol used here as they are identified in commercial products.


Assuntos
Poluição do Ar em Ambientes Fechados , Fluorocarbonos , Absorção Cutânea , Compostos Orgânicos , Exposição por Inalação/análise , Fluorocarbonos/análise
4.
Environ Sci Technol ; 57(38): 14351-14362, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37696050

RESUMO

This study elucidates per- and polyfluoroalkyl substance (PFAS) fingerprints for specific PFAS source types. Ninety-two samples were collected from aqueous film-forming foam impacted groundwater (AFFF-GW), landfill leachate, biosolids leachate, municipal wastewater treatment plant effluent (WWTP), and wastewater effluent from the pulp and paper and power generation industries. High-resolution mass spectrometry operated with electrospray ionization in negative mode was used to quantify up to 50 target PFASs and screen and semi-quantify up to 2,266 suspect PFASs in each sample. Machine learning classifiers were used to identify PFASs that were diagnostic of each source type. Four C5-C7 perfluoroalkyl acids and one suspect PFAS (trihydrogen-substituted fluoroethernonanoic acid) were diagnostic of AFFF-GW. Two target PFASs (5:3 and 6:2 fluorotelomer carboxylic acids) and two suspect PFASs (4:2 fluorotelomer-thia-acetic acid and N-methylperfluoropropane sulfonamido acetic acid) were diagnostic of landfill leachate. Biosolids leachates were best classified along with landfill leachates and N-methyl and N-ethyl perfluorooctane sulfonamido acetic acid assisted in that classification. WWTP, pulp and paper, and power generation samples contained few target PFASs, but fipronil (a fluorinated insecticide) was diagnostic of WWTP samples. Our results provide PFAS fingerprints for known sources and identify target and suspect PFASs that can be used for source allocation.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Biossólidos , Ácido Acético , Aprendizado de Máquina
5.
Environ Sci Technol ; 56(22): 15470-15477, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36265138

RESUMO

Anion-exchange (AE) sorbents are gaining in popularity for the remediation of anionic per- and polyfluoroalkyl substances (PFAS) in water. However, it is unclear how hydrophobic and electrostatic interactions contribute to anionic PFAS retention. The goal of this study was to understand the effects of PFAS chain length and head group on electrostatic interactions between PFAS and an aminopropyl AE phase. Liquid chromatography-mass spectrometry (LC-MS) was used with an aminopropyl AE guard column to find relative retention times. The average electrostatic potential (EPavg) of each PFAS was calculated, which correlated positively with the PFAS chromatographic retention time, demonstrating the value of EPavg as a proxy for predicting electrostatic interactions between PFAS and the aminopropyl AE phase. The order of greatest to lowest PFAS AE affinity for an aminopropyl column based on chromatographic retention times and electrostatic interactions was n:3 fluorotelomer carboxylic acids (n:3 FtAs) > n:2 fluorotelomer carboxylic acids (n:2 FtAs) > perfluoroalkyl carboxylates (PFCAs) > perfluoroalkyl sulfonamides (FASAs) ∼ n:2 fluorotelomer sulfonates (n:2 FtSs) > perfluoroalkyl sulfonates (PFSAs). This study introduces a methodology for qualitatively characterizing electrostatic interactions between PFAS and AE phases and highlights that electrostatic interactions alone cannot explain the affinity of PFAS for AE resins in water treatment/remediation scenarios.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Purificação da Água , Fluorocarbonos/análise , Poluentes Químicos da Água/análise , Ácidos Carboxílicos/análise , Ânions
6.
Environ Sci Technol ; 56(15): 10785-10797, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35852516

RESUMO

Per- and polyfluoroalkyl substances (PFAS), butyl carbitol, and corrosion inhibitors are components of aqueous film-forming foams (AFFFs). Volatile (neutral) fluorotelomerization (FT)- and electrochemical fluorination (ECF)-based PFAS, butyl carbitol, and organic corrosion inhibitors were quantified in 39 military specification (MilSpec), non-MilSpec, and alcohol resistant-AFFF concentrates (undiluted) from 1974 to 2010. Fluorotelomer alcohols were found only in FT-based AFFFs and N-methyl- and N-ethyl-perfluoroalkyl sulfonamides, and sulfonamido ethanols were found only in ECF-based AFFFs. Neutral PFAS and benzotriazole, 4-methylbenzotriazole, and 5-methybenzotriazole occurred at mg/L levels in the AFFFs, while butyl carbitol occurred at g/L levels. Neutral PFAS concentrations in indoor air due to vapor intrusion of a nearby undiluted AFFF release are estimated to be anywhere from 2 to >10 orders of magnitude higher than documented background indoor air concentrations. Estimated butyl carbitol and organic corrosion inhibitor concentrations were lower than and comparable to indoor concentrations recently measured, respectively. The wide range of neutral PFAS concentrations and Henry's law constants indicate that field, soil-gas measurements are needed to validate the estimations. Co-discharged butyl carbitol likely contributes to oxygen depletion in AFFF-impacted aquifers and may hinder the natural PFAS aerobic biotransformation. Organic corrosion inhibitors in AFFFs indicate that these are another source of corrosion inhibitors in the environment.


Assuntos
Fluorocarbonos , Água Subterrânea , Poluentes Químicos da Água , Aerossóis , Corrosão , Etilenoglicóis , Fluorocarbonos/análise , Gases , Água , Poluentes Químicos da Água/análise
7.
Environ Sci Technol ; 56(23): 17070-17079, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36367233

RESUMO

Paints are widely used in indoor settings yet there are no data for volatile per- and polyfluoroalkyl substances (PFAS) for paints or knowledge if paints are potentially important sources of human exposure to PFAS. Different commercial paints (n = 27) were collected from local hardware stores and analyzed for volatile PFAS by gas chromatography-mass spectrometry (GC-MS), nonvolatile PFAS by liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-qTOF), and total fluorine by 19F nuclear magnetic resonance spectroscopy (NMR). Diluted paint required clean up to remove 6:2 fluorotelomer phosphate diester (diPAP), which thermally transforms into 6:2 FTOH at 280 °C (GC inlet temperature). Only 6:2 FTOH (0.9-83 µg/g) and 6:2 diPAP (0.073-58 µg/g) were found in five exterior and nine interior paints and only accounted for a maximum of 17% of total fluorine. Upon drying, 40% of the FTOH mass was lost, and the loss was verified by measurements of the cumulative FTOH mass measured in the air of a small, confined space over a 3 h period. Based on the liquid paint results, the ConsExpo model was used for potential exposure assessment and one commercial paint exceeded the chosen reference dose (5 µg/kg-day) for children and adults, indicating the potential for human exposure during painting.


Assuntos
Fluorocarbonos , Exposição por Inalação , Criança , Humanos , Exposição por Inalação/análise , Fluorocarbonos/análise , Flúor/análise , Pintura , Cromatografia Gasosa-Espectrometria de Massas
8.
Environ Sci Technol ; 56(15): 10646-10655, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35861429

RESUMO

Despite the prevalence of nitrate reduction in groundwater, the biotransformation of per- and polyfluoroalkyl substances (PFAS) under nitrate-reducing conditions remains mostly unknown compared with aerobic or strong reducing conditions. We constructed microcosms under nitrate-reducing conditions to simulate the biotransformation occurring at groundwater sites impacted by aqueous film-forming foams (AFFFs). We investigated the biotransformation of 6:2 fluorotelomer thioether amido sulfonate (6:2 FtTAoS), a principal PFAS constituent of several AFFF formulations using both quantitative liquid chromatography-tandem mass spectrometry (LC-MS/MS) and qualitative high-resolution mass spectrometry analyses. Our results reveal that the biotransformation rates of 6:2 FtTAoS under nitrate-reducing conditions were about 10 times slower than under aerobic conditions, but about 2.7 times faster than under sulfate-reducing conditions. Although minimal production of 6:2 fluorotelomer sulfonate and the terminal perfluoroalkyl carboxylate, perfluorohexanoate was observed, fluorotelomer thioether and sulfinyl compounds were identified in the aqueous samples. Evidence for the formation of volatile PFAS was obtained by mass balance analysis using the total oxidizable precursor assay and detection of 6:2 fluorotelomer thiol by gas chromatography-mass spectrometry. Our results underscore the complexity of PFAS biotransformation and the interactions between redox conditions and microbial biotransformation activities, contributing to the better elucidation of PFAS environmental fate and impact.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Alcanossulfonatos , Biotransformação , Cromatografia Líquida , Fluorocarbonos/análise , Nitratos/análise , Sulfetos , Espectrometria de Massas em Tandem , Água , Poluentes Químicos da Água/análise
9.
Environ Sci Technol ; 56(2): 974-983, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34961317

RESUMO

Firefighter turnout gear is essential for reducing occupational exposure to hazardous chemicals during training and fire events. Per-and polyfluoroalkyl substances (PFASs) are observed in firefighter serum, and possible occupational sources include the air and dust of fires, aqueous film-forming foam, and turnout gear. Limited data exist for nonvolatile and volatile PFASs on firefighter turnout gear and the disposition of fluorine on the individual layers of turnout gear. Further implications for exposure to fluorine on turnout gear are not well understood. Three unused turnout garments purchased in 2019 and one purchased in 2008, were analyzed for 50 nonvolatile and 15 volatile PFASs by liquid chromatography quadrupole time-of-flight mass spectrometry (LC-qTOF-MS) and gas chromatography-mass spectrometry (GC-MS), respectively. Particle-induced gamma ray emission (PIGE), a surface technique, and instrumental neutron activation analysis (INAA), a bulk technique, were used to measure total fluorine. Bulk characterization of the layers by pyrolysis-GC/MS (py-GC/MS) was used to differentiate fluoropolymer (e.g., PTFE) films from textile layers finished with side-chain polymers. The outer layer, moisture barrier, and thermal layers of the turnout gear all yielded measured concentrations of volatile PFASs that exceeded nonvolatile PFAS concentrations, but the summed molar concentrations made up only a small fraction of total fluorine (0.0016-6.7%). Moisture barrier layers comprised a PTFE film, as determined by py-GC-MS, and gave the highest individual nonvolatile (0.159 mg F/kg) and volatile PFAS (20.7 mg F/kg) as well as total fluorine (122,000 mg F/kg) concentrations. Outer and thermal layers comprised aromatic polyamide-based fibers (aramid) treated with side-chain fluoropolymers and had lower levels of individual nonvolatile and volatile PFASs. Equal concentrations of total fluorine by both PIGE and INAA on the outer and thermal layers is consistent with treatment with a side-chain fluoropolymer coating. New turnout gear should be examined as a potential source of firefighter occupational exposure to nonvolatile and volatile PFASs in future assessments.


Assuntos
Bombeiros , Fluorocarbonos , Exposição Ocupacional , Cromatografia Líquida , Flúor/análise , Fluorocarbonos/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Exposição Ocupacional/análise
10.
Chem Res Toxicol ; 34(6): 1409-1416, 2021 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-34018735

RESUMO

Per- and polyfluoroalkyl substances (PFAS) are ubiquitously detected in the environment, and some pose significant human and environmental health concerns globally. While some PFAS induce adverse health effects, relatively few toxicological studies adequately address the broad structural diversity of this chemical class. In the current study, we evaluated 58 individual PFAS spanning 14 structural subclasses and 2 mixtures at single concentrations for developmental toxicity in zebrafish using highly sensitive behavior endpoints. Following developmental exposure to PFAS, zebrafish were assessed for mortality and challenged with an embryonic photomotor response (EPR) assay at 24 h postfertilization (hpf) and with larval photomotor response (LPR) and larval startle response assays at 120 hpf. We found that none of the tested PFAS exposures elicited significant mortality or aberrant EPR; however, exposure to 21 individual PFAS from multiple structural subclasses and 1 mixture induced aberrant larval behavior. We then evaluated developmental toxicity across a concentration range of 0-100 µM for 10 perfluoroalkyl carboxylic acids (PFCAs; 4-carbon perfluorobutanoic acid through the 13-carbon perfluorotridecanoic acid). Exposure to the PFCAs did not cause significant mortality or morphological effects, with the exception of perfluorooctanoic acid and perfluorononanoic acid, and did not induce aberrant EPR. All PFCAs, except for longer-chain perfluorododecanoic acid caused abnormal LPR following exposure to at least one concentration. In this study, we evaluated a broad set of PFAS not previously assessed for in vivo sublethal behavior endpoints and confirmed previous findings that exposure to some PFAS induces abnormal behavior in developing zebrafish. The data from this study will guide the selection of PFAS for which to investigate modes of toxic action.


Assuntos
Embrião não Mamífero/efeitos dos fármacos , Fluorocarbonos/toxicidade , Animais , Fluorocarbonos/química , Peixe-Zebra/embriologia
11.
Environ Sci Technol ; 55(1): 313-323, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33351591

RESUMO

Soil and groundwater from an aqueous film-forming foam (AFFF)-impacted site were sampled at high resolution (n = 105 for soil, n = 58 for groundwater) and analyzed for an extensive list of anionic, zwitterionic, and cationic poly- and perfluoroalkyl substances (PFASs). Spatial trends for perfluoroalkyl acids and many precursors enabled a better understanding of PFAS composition, transport, and transformation. All PFASs without analytical standards were semi-quantified. Summed PFAS and individual PFAS concentrations were often higher at depth than near the surface in soil and groundwater. Zwitterionic and cationic compounds composed a majority of the total PFAS mass (up to 97%) in firefighter training area (FTA) soil. Composition of PFAS class, chain length, and structural isomers changed with depth and distance from the FTA, suggesting in situ transformation and differential transport. The percentage of branched perfluorooctane sulfonate increased with depth, consistent with differential isomeric transport. However, linear perfluorooctanoic acid (PFOA) was enriched, suggesting fluorotelomer precursor transformation to linear PFOA. Perfluorohexane sulfonamide, a potential transformation product of sulfonamide-based PFASs, was present at high concentrations (maximum 448 ng/g in soil, 3.4 mg/L in groundwater). Precursor compounds may create long-term sources of perfluoroalkyl acids, although many pathways remain unknown; precursor analysis is critical for PFAS fate and transport understanding.


Assuntos
Ácidos Alcanossulfônicos , Fluorocarbonos , Água Subterrânea , Poluentes Químicos da Água , Fluorocarbonos/análise , Solo , Água , Poluentes Químicos da Água/análise
12.
Environ Sci Technol ; 55(11): 7237-7245, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33983714

RESUMO

The source tracking of per- and polyfluoroalkyl substances (PFASs) is a new and increasingly necessary subfield within environmental forensics. We define PFAS source tracking as the accurate characterization and differentiation of multiple sources contributing to PFAS contamination in the environment. PFAS source tracking should employ analytical measurements, multivariate analyses, and an understanding of PFAS fate and transport within the framework of a conceptual site model. Converging lines of evidence used to differentiate PFAS sources include: identification of PFASs strongly associated with unique sources; the ratios of PFAS homologues, classes, and isomers at a contaminated site; and a site's hydrogeochemical conditions. As the field of PFAS source tracking progresses, the development of new PFAS analytical standards and the wider availability of high-resolution mass spectral data will enhance currently available analytical capabilities. In addition, multivariate computational tools, including unsupervised (i.e., exploratory) and supervised (i.e., predictive) machine learning techniques, may lead to novel insights that define a targeted list of PFASs that will be useful for environmental PFAS source tracking. In this Perspective, we identify the current tools available and principal developments necessary to enable greater confidence in environmental source tracking to identify and apportion PFAS sources.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Fluorocarbonos/análise , Poluentes Químicos da Água/análise
13.
Environ Sci Technol ; 54(22): 14455-14464, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33164508

RESUMO

Information is needed on the concentration of per- and polyfluoroalkyl substances (PFAS) in foams on surface waters impacted by aqueous film-forming foam (AFFF). Nine pairs of foam and underlying bulk water were collected from a single freshwater lake impacted by PFAS and analyzed for PFAS by liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QToF) and for dissolved organic carbon (DOC). The DOC of two foam:bulk water pairs was characterized by 1H NMR. Foams were comprised of 16 PFAS with concentrations as high as 97 000 ng/L (PFOS) along with longer-chain, more hydrophobic PFAS. Only five PFAS (PFOS and shorter chain lengths) were quantified in underlying bulk waters. Enrichment factors (foam:bulk water) ranged from 10 (PFHxA) up to 2830 (PFOS). Foams impacted by AFFF gave the greatest concentrations and number of PFAS classes with PFOS concentrations exceeding the EPA health advisory level (70 ng/L). PFAS concentrations were significantly below published critical micelle concentrations and constituted <0.1% of overall DOC concentrations in foam, indicating that PFAS are a minor fraction of DOC and that DOC likely plays a central role in foam formation. Estimates indicate that foam ingestion is a potentially important route of exposure for children and adults when they are in surface waters where foam is present.


Assuntos
Fluorocarbonos , Poluentes Químicos da Água , Adulto , Carbono , Criança , Fluorocarbonos/análise , Humanos , Lagos , Água , Poluentes Químicos da Água/análise
14.
Environ Sci Technol ; 53(14): 8068-8077, 2019 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-31269393

RESUMO

Aqueous film-forming foams (AFFFs) are proprietary mixtures containing hydrocarbon surfactants and per- and polyfluoroalkyl substances (PFASs) that are used to extinguish hydrocarbon-based fuel fires. There is limited information on hydrocarbon surfactants in AFFFs and AFFF-contaminated groundwater even though hydrocarbon surfactants are more abundant (5-10% w/w) than PFASs (0.9-1.5% w/w) in AFFFs. Eight commercial AFFFs manufactured between 1988 and 2012 and 10 AFFF-contaminated groundwaters collected from near source zones of fire-fighter training areas were analyzed for suspect hydrocarbon surfactants by liquid chromatography quadrupole time-of-flight mass spectrometry. A suspect list and a homologous series detection computational tool, enviMass, were combined to screen for hydrocarbon surfactants. Nine classes of hydrocarbon surfactants were detected in AFFFs including octylphenol polyethoxylates, linear alcohol ethoxylates, ethoxylated cocoamines, alkyl ether sulfates, alkyl amido dipropionates, linear alkyl benzenesulfonates, alkyl sulfates, and polyethylene glycols. Of those, six were also found in groundwater along with diethanolamines and alkyl amido betaines, which were not found in the eight archived AFFFs. This indicates that although aerobically biodegradable, hydrocarbon surfactants likely persist in groundwater due to anaerobic aquifer conditions. To the best of our knowledge, this is the first screening for hydrocarbon surfactants in AFFFs and in AFFF-contaminated groundwater.


Assuntos
Fluorocarbonos , Água Subterrânea , Poluentes Químicos da Água , Hidrocarbonetos , Tensoativos
17.
Environ Sci Technol ; 52(18): 10609-10616, 2018 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-30148348

RESUMO

Volatile per- and polyfluorinated alkyl substances (PFASs) are found in consumer goods that contribute to human exposure to PFASs. Volatile PFAS precursors transform to perfluorinated carboxylates (PFCAs) and sulfonates (PFSAs) in both humans and the environment. Established methods for volatile PFASs in consumer goods exist, but higher sample throughput and greener sample preparation methods are needed to minimize analyte loss, while maintaining sensitivity. New analytical methodology was developed where a 1.5 × 1.5 cm piece of paper or textile is placed into an autosampler vial with solvent and mass-labeled internal standards, sonicated for 30 min, and directly injected without removal of material from the autosampler vial. Large volume injection (20 µL) gas chromatography mass spectrometry was applied for the quantification for 21 individual PFASs from five classes: fluorotelomer alcohols (FTOHs), fluorinated sulfonamides (N-MeFASA, N-EtFASA), and fluorinated sulfonamidoethanols (N-MeFASE, N-EtFASE). Nontargeted analysis revealed additional C2-C7 homologues of N-MeFASE and N-EtFASE, which accounted for 14-18% of the total volatile PFASs on three textiles. Overlooking short-chain (≤C7) N-MeFASE, N-EtFASE, and long-chained (10:2-14:2) FTOHs on older textiles from the 1980s leads to an underestimation of human and environmental exposure to volatile PFAS.


Assuntos
Fluorocarbonos , Ácidos Carboxílicos , Monitoramento Ambiental , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Têxteis
19.
Environ Sci Technol ; 51(21): 12394-12404, 2017 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-28968065

RESUMO

During fire-fighter training, equipment testing, and emergency responses with aqueous film-forming foams (AFFFs), milligrams per liter concentrations of anionic, zwitterionic, and cationic per- and polyfluoroalkyl substances (PFASs) enter the environment. Because the behavior of zwitterionic and cationic PFASs in the subsurface is unknown, batch sorption experiments were conducted using National Foam AFFF, which contains anionic fluorotelomer sulfonates (FtSs), zwitterionic fluorotelomer sulfonamido betaines (FtSaBs), and cationic 6:2 fluorotelomer sulfonamido amine (FtSaAm). Sorption of the FtSs, FtSaBs, and 6:2 FtSaAm to six soils with varying organic carbon, effective cation-exchange capacity, and anion-exchange capacity was evaluated to determine sorption mechanisms. Due to the poor recovery of the FtSaBs and 6:2 FtSaAm with published PFAS soil extraction methods, a new soil extraction method was developed to achieve good (90-100%) recoveries. The 6:2 FtSaAm was depleted from the aqueous phase in all but one soil, which is attributed to electrostatic and hydrophobic interactions. Sorption of the FtSs was driven by hydrophobic interactions, while the FtSaBs behave more like cations that strongly associate with the solid phase relative to groundwater. Thus, the sorption mechanisms of the FtSs, FtSaBs, and 6:2 FtSaAm are more complex than expected and cannot be predicted by bulk soil properties.


Assuntos
Betaína , Poluentes Químicos da Água , Aminas , Fluorocarbonos , Solo
20.
Environ Sci Technol ; 51(16): 9022-9032, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28712295

RESUMO

Papers and textiles that are treated with per- and polyfluoroalkyl substances (PFASs) are sources of human and environmental exposure. Data for individual PFASs, such as perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA), are not placed into the context of total fluorine for papers and textiles. Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used to quantify volatile and ionic PFASs, respectively, and the total oxidizable precursor (TOP) assay was used to quantify precursors that form perfluoroalkyl carboxylates. Molar sums of PFASs obtained by GC-MS, LC-MS/MS, and precursors were compared to total fluorine (nmol F/cm2) determined by particle-induced gamma ray emission (PIGE) spectroscopy, measured before and after extraction. Volatile and ionic PFASs and unknown precursors accounted for 0-2.2%, 0-0.41%, and 0.021-14%, respectively, of the total nmol F/cm2 determined by PIGE. After extraction, papers and textiles retained 64 ± 28% to 110 ± 30% of the original nmol F/cm2 as determined by PIGE, indicating that the majority of fluorine remains associated with the papers and textiles. The sum of PFASs in the volatile, ionic, and precursor fraction, and total fluorine after extraction indicate that mass balance was achieved (within analytical error) of the initial total fluorine measured by PIGE.


Assuntos
Flúor , Têxteis , Poluentes Químicos da Água , Cromatografia Líquida , Fluorocarbonos , Humanos , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA