1.
J Card Surg ; 37(1): 70-75, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34669217

RESUMO

OBJECTIVES: As aortic valve repair (AVr) for aortic insufficiency (AI) expands, minimally invasive (Mi) approaches are increasingly being applied. Cardiac surgical techniques can be more difficult through small incisions, and this report analyzes medium-term outcomes for MiAVr facilitated by geometric ring annuloplasty. METHODS: Since 2013, 58 patients were selected for AVr through upper sternotomy third-interspace incisions. The average age was 58.9 ± 15.4 (mean ± SD) years, 71% were male, and preoperative AI grade was 3.6 ± 0.8. Sixty-two percent (36/58) had a proximal aortic replacement for ascending aortic aneurysms (n = 26) and/or remodeling grafts for aortic root aneurysms (n = 10). Annuloplasty rings were placed subannularly (69% trileaflet; 31% bicuspid), and leaflet procedures were performed in 70%. The average ring diameter was 21.6 ± 1.4 mm, and the average aortic clamp time was 113 ± 35 min. RESULTS: After repair, AI grade fell to an average of 0.5 ± 0.6 (p < .0001), with a mean valve gradient of 12.5 ± 7.1 mmHg. No operative mortalities or major complications occurred. Three patients required reoperations for bleeding, and two had pacemakers. At an average follow-up of 38 months (maximal 88 months), three late deaths and no valve-related complications were observed. Four patients required reoperative aortic valve replacement over follow-up, and Kaplan-Meier survival and freedom from reoperation both exceeded 80% at 88 months. At the last follow-up, the average AI grade was 0.7 ± 0.7, and the mean valve gradient was 12.7 ± 6.3 mmHg. CONCLUSIONS: Geometric ring annuloplasty was safe and seemed to facilitate performing AVr ± proximal aortic replacement through Mi incisions. Hemodynamic improvements were significant, medium-term clinical outcomes were acceptable, and results could improve further with experience.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Resultado do Tratamento
2.
Circ Res ; 120(11): 1800-1811, 2017 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-28420669

RESUMO

RATIONALE: The pathogenesis of bicuspid aortic valve (BAV)-associated aortopathy is poorly understood, and no prognostic biomarker is currently available. OBJECTIVE: We aimed to identify putative circulating biomarkers pathogenetically and prognostically linked to bicuspid aortopathy. METHODS AND RESULTS: By reverse transcription polymerase chain reaction, we evaluated gene expression variations (versus normal aorta) of transforming growth factor-ß1 (TGF-ß1), connective tissue growth factor, matrix metalloproteinase-2 (MMP-2), MMP-14, endoglin (ENG), and superoxide dismutase 3 in ascending aorta samples from 50 tricuspid and 70 patients with BAV undergoing surgery for aortic stenosis (aorta diameter ≤45 mm: BAVnon-dil or >45 mm: BAVdil). Expression changes of the TGF-ß1 active dimer and ENG were analyzed also by Western blot in ascending aorta samples from other 10 tricuspid aortic valve, 10 BAVnon-dil, and 10 BAVdil patients. The serum concentration of study targets was assessed through ELISA and the ratio of serum TGF-ß1/ENG (T/E) was evaluated. All BAVnon-dil patients underwent follow-up echocardiography to assess aortic growth rate. In BAVnon-dil patients, TGF-ß1 and MMP-2 gene expression increased significantly, whereas MMP-14 and ENG expression decreased versus controls. Expression changes were confirmed at protein level for TGF-ß1 and ENG. TGF-ß1 serum concentration significantly decreased in tricuspid aortic valve and BAVnon-dil patients versus healthy subjects. ENG serum concentration decreased in all patients, more markedly in BAVdil. A significant increase of the T/E ratio versus healthy subjects was unique of patients with BAV. In BAVnon-dil patients, a T/E ≥9 was independently associated in multivariable analysis with higher MMP-2 and lower superoxide dismutase 3 gene expression, independent of age and aortic diameter. A significant correlation was observed between baseline T/E ratio and aortic diameter growth rate in BAVnon-dil patients (r=0.66, P<0.001). CONCLUSIONS: The novel evidence of a possible value of the T/E ratio as a biomarker of BAV aortopathy was presented: further validation studies are warranted.


Assuntos
Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Endoglina/sangue , Doenças das Valvas Cardíacas/sangue , Doenças das Valvas Cardíacas/diagnóstico por imagem , Fator de Crescimento Transformador beta1/sangue , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Biomarcadores/sangue , Ecocardiografia , Feminino , Seguimentos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
3.
JTCVS Tech ; 14: 55-65, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35967205

RESUMO

Objectives: Geometric ring annuloplasty has shown promise during bicuspid aortic valve repair for aortic insufficiency. This study examined early outcomes of bicuspid aortic valve repair associated with proximal aortic aneurysm replacement. Methods: From September 2017 to November, 2021, 127 patients underwent bicuspid aortic valve repair with concomitant proximal aneurysm reconstruction. Patient age was 50.6 ± 12.7 years (mean ± standard deviation), male gender was 83%, New York Heart Association Class was 2 (1-2) (median [interquartile range]), and preoperative aortic insufficiency grade was 3 (2-4). Ascending aortic diameter was 50 (46-54) mm, and all patients had ascending aortic replacement. Forty patients had sinus diameters greater than 45 mm, prompting remodeling root procedures. A total of 105 patients had Sievers type 1 valves, 3 patients had type 0, and 7 patients had type 2. A total of 118 patients had primarily right/left fusion, 8 patients had right/nonfusion, and 1 patient had left/nonfusion. Leaflet reconstruction used central leaflet plication and cleft closure, with limited ultrasonic decalcification in 31 patients. Results: Ring size was 23 (21-23) mm, and 26 of 40 root procedures were selective nonfused sinus replacements. Aortic clamp time was 139 (112-170) minutes, and bypass time was 178 (138-217) minutes. Postrepair aortic insufficiency grade was 0 (0-0) (P < .0001), and mean valve gradient was 10 (7-14) mm Hg. No early and 1 late mortality occurred. Four patients required reoperation for bleeding, and 4 patients required pacemakers. At a mean follow-up of 20 months (maximal 93), there were no valve-related complications, 5 late repair failures prompting valve replacement, and 1 death due to Coronavirus Disease 2019. Conclusions: Geometric ring annuloplasty for bicuspid aortic valve repair with proximal aortic aneurysm reconstruction is safe and associated with good early outcomes. Further experience and follow-up will help inform long-term durability.

4.
JTCVS Tech ; 1: 18-25, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34317698

RESUMO

OBJECTIVE: As bicuspid aortic valve (BAV) repair evolves, more effective annular reduction and stabilization could be advantageous. A geometric annuloplasty ring has been developed, and 2-year regulatory outcomes of a first-in-humans pilot trial are reported. METHODS: A prospective first-in-humans trial of BAV ring annuloplasty was completed in 16 patients. Patient age was 44.4 ± 11.3 (mean ± standard deviation) years, preoperative aortic insufficiency grade was 2.5 ± 1.0, New York Heart Association class 1.8 ± 0.4, and mean systolic gradient 13.4 ± 12.9 mm Hg. Three patients had Sievers type 0 BAV, 11 had type 1, and 2 were type 2. The Dacron-covered titanium rings had circular base geometry with 180° subcommissural posts and were implanted subannularly. Leaflets were reconstructed using plication/cleft closure, creating an effective height of ≥8 mm, even if modest gradients were induced. RESULTS: Mean pre-repair annular diameter was 28.6 ± 3.3 mm, and the average ring diameter was 22.3 ± 1.6 mm. All valves required leaflet plication/reconstruction; pericardium was avoided; and 7 patients had aortic replacement for aneurysms. No early mortalities or major complications occurred. Two patients required early prosthetic valve replacement for technical errors, and all were between 24-38 months' postoperative at follow-up. No late mortalities or valve-related complications occurred, and all patients reverted to New York Heart Association class I. Aortic insufficiency reduction was significant to grade 0.9 ± 0.5 at 2-years (P < .0001). Mean valve gradients were acceptable (13.3 ± 5.0 mm Hg at 2 years; overall P = .11) and tended to fall over time (P < .0001). CONCLUSIONS: Geometric ring annuloplasty was safe and effective for BAV repair. AI reduction was significant, valve gradients were satisfactory, and clinical outcomes were excellent. Geometric ring annuloplasty could simplify and standardize BAV repair.

5.
Innovations (Phila) ; 12(6): 483-485, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29200087

RESUMO

We report a case of infective endocarditis on a Perceval S aortic valve bioprosthesis, and we describe a feasible and useful technique that can help remove the infected valve. These maneuvers consist of an "x-movement" reached with the aid of anatomical forceps. The risk of infective endocarditis in patients with prosthetic valves is a well-known phenomena in cardiac surgery, and it can represent a life-threatening event in many cases. According to guidelines, an emergency surgical intervention is required in case of high risk of embolization, vegetation superior than 1 cm or acute cardiac failure secondary to the acute valve dysfunction. In the reported case, the patient was submitted to emergency surgery because of vegetation with diameter superior to 1 cm on the aortic bioprosthesis. The described "x-movement" technique allowed an easily "en block" excision of the damaged bioprostheses together with vegetation, minimizing the risk of vegetation fragmentation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Bioprótese , Calcinose/cirurgia , Doença da Artéria Coronariana/cirurgia , Remoção de Dispositivo/métodos , Endocardite Bacteriana/cirurgia , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese/cirurgia , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Calcinose/complicações , Ponte de Artéria Coronária , Doença da Artéria Coronariana/complicações , Humanos , Masculino , Infarto do Miocárdio sem Supradesnível do Segmento ST/etiologia , Púrpura Trombocitopênica Idiopática/complicações
6.
Innovations (Phila) ; 11(3): 165-73, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27540996

RESUMO

OBJECTIVE: To define the benefit of sutureless and rapid deployment valves in current minimally invasive approaches in isolated aortic valve replacement. METHODS: A panel of 28 international experts with expertise in both minimally invasive aortic valve replacement and rapid deployment valves was constituted. After thorough literature review, the experts rated evidence-based recommendations in a modified Delphi approach. RESULTS: No guideline could be retrieved. Thirty-three clinical trials and 9 systematic reviews could be identified for detailed text analysis to obtain a total of 24 recommendations. After rating by the experts 12, final recommendations were identified: preoperative computed tomographic scan as well as intraoperative transesophageal echocardiography are highly recommended. Suitable annular sizes are 19 to 27 mm. There is a contraindication for bicuspid valves only for type 0 and for annular abscess or destruction due to infective endocarditis. The use of sutureless and rapid deployment valves reduces extracorporeal circulation and aortic cross-clamp time and leads to less early complications as prolonged ventilation, blood transfusion, atrial fibrillation, pleural effusions, paravalvular leakages and aortic regurgitation, and renal replacement therapy, respectively. These clinical outcomes result in reduced intensive care unit and hospital stay and reduced costs. The use of sutureless and rapid deployment valves will lead to a higher adoption rate of minimally invasive approaches in aortic valve replacement. Respect should be taken to a necessary short learning curve for both sutureless and minimally invasive programs. CONCLUSIONS: Sutureless and rapid deployment aortic valve replacement together with minimally invasive approaches offers an attractive option in aortic valve placement for patients requiring biological valve replacement.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Ensaios Clínicos como Assunto , Medicina Baseada em Evidências , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Técnicas de Sutura