Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 84(5): 2569-75, 2012 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-22250703

RESUMO

Porous agarose microbeads, with high surface to volume ratios and high binding densities, are attracting attention as highly sensitive, affordable sensor elements for a variety of high performance bioassays. While such polymer microspheres have been extensively studied and reported on previously and are now moving into real-world clinical practice, very little work has been completed to date to model the convection, diffusion, and binding kinetics of soluble reagents captured within such fibrous networks. Here, we report the development of a three-dimensional computational model and provide the initial evidence for its agreement with experimental outcomes derived from the capture and detection of representative protein and genetic biomolecules in 290 µm porous beads. We compare this model to antibody-mediated capture of C-reactive protein and bovine serum albumin, along with hybridization of oligonucleotide sequences to DNA probes. These results suggest that, due to the porous interior of the agarose bead, internal analyte transport is both diffusion and convection based, and regardless of the nature of analyte, the bead interiors reveal an interesting trickle of convection-driven internal flow. On the basis of this model, the internal to external flow rate ratio is found to be in the range of 1:170 to 1:3100 for beads with agarose concentration ranging from 0.5% to 8% for the sensor ensembles here studied. Further, both model and experimental evidence suggest that binding kinetics strongly affect analyte distribution of captured reagents within the beads. These findings reveal that high association constants create a steep moving boundary in which unbound analytes are held back at the periphery of the bead sensor. Low association constants create a more shallow moving boundary in which unbound analytes diffuse further into the bead before binding. These models agree with experimental evidence and thus serve as a new tool set for the study of bioagent transport processes within a new class of medical microdevices.


Assuntos
Microesferas , Modelos Teóricos , Animais , Proteína C-Reativa/metabolismo , Bovinos , Difusão , Cinética , Porosidade , Ligação Proteica , Sefarose/química , Soroalbumina Bovina/metabolismo
2.
Sensors (Basel) ; 12(11): 15467-99, 2012 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-23202219

RESUMO

Advances in lab-on-a-chip systems have strong potential for multiplexed detection of a wide range of analytes with reduced sample and reagent volume; lower costs and shorter analysis times. The completion of high-fidelity multiplexed and multiclass assays remains a challenge for the medical microdevice field; as it struggles to achieve and expand upon at the point-of-care the quality of results that are achieved now routinely in remote laboratory settings. This review article serves to explore for the first time the key intersection of multiplexed bead-based detection systems with integrated microfluidic structures alongside porous capture elements together with biomarker validation studies. These strategically important elements are evaluated here in the context of platform generation as suitable for near-patient testing. Essential issues related to the scalability of these modular sensor ensembles are explored as are attempts to move such multiplexed and multiclass platforms into large-scale clinical trials. Recent efforts in these bead sensors have shown advantages over planar microarrays in terms of their capacity to generate multiplexed test results with shorter analysis times. Through high surface-to-volume ratios and encoding capabilities; porous bead-based ensembles; when combined with microfluidic elements; allow for high-throughput testing for enzymatic assays; general chemistries; protein; antibody and oligonucleotide applications.


Assuntos
Técnicas Biossensoriais , Atenção à Saúde , Diagnóstico , Dispositivos Lab-On-A-Chip , Biomarcadores/análise , Humanos , Microfluídica , Microscopia Eletrônica de Varredura , Sistemas Automatizados de Assistência Junto ao Leito
3.
Small ; 7(5): 613-24, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21290601

RESUMO

The slow development of cost-effective medical microdevices with strong analytical performance characteristics is due to a lack of selective and efficient analyte capture and signaling. The recently developed programmable bio-nano-chip (PBNC) is a flexible detection device with analytical behavior rivaling established macroscopic methods. The PBNC system employs ≈300 µm-diameter bead sensors composed of agarose "nanonets" that populate a microelectromechanical support structure with integrated microfluidic elements. The beads are an efficient and selective protein-capture medium suitable for the analysis of complex fluid samples. Microscopy and computational studies probe the 3D interior of the beads. The relative contributions that the capture and detection of moieties, analyte size, and bead porosity make to signal distribution and intensity are reported. Agarose pore sizes ranging from 45 to 620 nm are examined and those near 140 nm provide optimal transport characteristics for rapid (<15 min) tests. The system exhibits efficient (99.5%) detection of bead-bound analyte along with low (≈2%) nonspecific immobilization of the detection probe for carcinoembryonic antigen assay. Furthermore, the role analyte dimensions play in signal distribution is explored, and enhanced methods for assay building that consider the unique features of biomarker size are offered.


Assuntos
Biomarcadores/análise , Dispositivos Lab-On-A-Chip , Indicadores e Reagentes/química , Microesferas , Sefarose/química
4.
Anal Chem ; 82(5): 1571-9, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20128622

RESUMO

There have been many recent advances in the nano-bio-chip analysis methodology with implications for a number of high-morbidity diseases including HIV, cancer, and heart disease. (To listen to a podcast about this article, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html .).


Assuntos
Técnicas Biossensoriais , Nanotecnologia , Humanos , Microfluídica
5.
Tex Dent J ; 127(7): 651-61, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20737986

RESUMO

Saliva can be easily obtained in medical and non-medical settings, and contains numerous bio-molecules, including those typically found in serum for disease detection and monitoring. In the past two decades, the achievements of high-throughput approaches afforded by biotechnology and nanotechnology allow for disease-specific salivary biomarker discovery and establishment of rapid, multiplex, and miniaturized analytical assays. These developments have dramatically advanced saliva-based diagnostics. In this review, we discuss the current consensus on development of saliva/oral fluid-based diagnostics and provide a summary of recent research advancements of the Texas-Kentucky Saliva Diagnostics Consortium. In the foreseeable future, current research on saliva based diagnostic methods could revolutionize health care.


Assuntos
Saliva/química , Biomarcadores/análise , Técnicas e Procedimentos Diagnósticos , Humanos , Dispositivos Lab-On-A-Chip , Saliva/citologia , Saliva/fisiologia
6.
Clin Chem ; 55(8): 1530-8, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19556448

RESUMO

BACKGROUND: For adults with chest pain, the electrocardiogram (ECG) and measures of serum biomarkers are used to screen and diagnose myocardial necrosis. These measurements require time that can delay therapy and affect prognosis. Our objective was to investigate the feasibility and utility of saliva as an alternative diagnostic fluid for identifying biomarkers of acute myocardial infarction (AMI). METHODS: We used Luminex and lab-on-a-chip methods to assay 21 proteins in serum and unstimulated whole saliva procured from 41 AMI patients within 48 h of chest pain onset and from 43 apparently healthy controls. Data were analyzed by use of logistic regression and area under curve (AUC) for ROC analysis to evaluate the diagnostic utility of each biomarker, or combinations of biomarkers, in screening for AMI. RESULTS: Both established and novel cardiac biomarkers demonstrated significant differences in concentrations between patients with AMI and controls without AMI. The saliva-based biomarker panel of C-reactive protein, myoglobin, and myeloperoxidase exhibited significant diagnostic capability (AUC = 0.85, P < 0.0001) and in conjunction with ECG yielded strong screening capacity for AMI (AUC = 0.96) comparable to that of the panel (brain natriuretic peptide, troponin-I, creatine kinase-MB, myoglobin; AUC = 0.98) and far exceeded the screening capacity of ECG alone (AUC approximately 0.6). En route to translating these findings to clinical practice, we adapted these unstimulated whole saliva tests to a novel lab-on-a-chip platform for proof-of-principle screens for AMI. CONCLUSIONS: Complementary to ECG, saliva-based tests within lab-on-a-chip systems may provide a convenient and rapid screening method for cardiac events in prehospital stages for AMI patients.


Assuntos
Biomarcadores/análise , Infarto do Miocárdio/diagnóstico , Análise Serial de Proteínas/métodos , Proteínas/análise , Saliva/química , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Proteínas Sanguíneas/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Curva ROC , Sensibilidade e Especificidade
7.
Oral Oncol ; 92: 6-11, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31010626

RESUMO

OBJECTIVES: The diagnosis and management of oral cavity cancers are often complicated by the uncertainty of which patients will undergo malignant transformation, obligating close surveillance over time. However, serial biopsies are undesirable, highly invasive, and subject to inherent issues with poor inter-pathologist agreement and unpredictability as a surrogate for malignant transformation and clinical outcomes. The goal of this study was to develop and evaluate a Multivariate Analytical Risk Index for Oral Cancer (MARIO) with potential to provide non-invasive, sensitive, and quantitative risk assessments for monitoring lesion progression. MATERIALS AND METHODS: A series of predictive models were developed and validated using previously recorded single-cell data from oral cytology samples resulting in a "continuous risk score". Model development consisted of: (1) training base classification models for each diagnostic class pair, (2) pairwise coupling to obtain diagnostic class probabilities, and (3) a weighted aggregation resulting in a continuous MARIO. RESULTS AND CONCLUSIONS: Diagnostic accuracy based on optimized cut-points for the test dataset ranged from 76.0% for Benign, to 82.4% for Dysplastic, 89.6% for Malignant, and 97.6% for Normal controls for an overall MARIO accuracy of 72.8%. Furthermore, a strong positive relationship with diagnostic severity was demonstrated (Pearson's coefficient = 0.805 for test dataset) as well as the ability of the MARIO to respond to subtle changes in cell composition. The development of a continuous MARIO for PMOL is presented, resulting in a sensitive, accurate, and non-invasive method with potential for enabling monitoring disease progression, recurrence, and the need for therapeutic intervention of these lesions.


Assuntos
Citodiagnóstico , Neoplasias Bucais/diagnóstico , Biópsia , Citodiagnóstico/instrumentação , Citodiagnóstico/métodos , Citodiagnóstico/normas , Humanos , Dispositivos Lab-On-A-Chip , Análise Multivariada , Gradação de Tumores , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Medição de Risco
8.
Lab Chip ; 8(12): 2079-90, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19023471

RESUMO

Recent humanitarian efforts have led to the widespread release of antiretroviral drugs for the treatment of the more than 33 million HIV afflicted people living in resource-scarce settings. Here, the enumeration of CD4+ T lymphocytes is required to establish the level at which the immune system has been compromised. The gold standard method used in developed countries, based on flow cytometry, though widely accepted and accurate, is precluded from widespread use in resource-scarce settings due to its high expense, high technical requirements, difficulty in operation-maintenance and the lack of portability for these sophisticated laboratory-confined systems. As part of continuing efforts to develop practical diagnostic instrumentation, the integration of semiconductor nanocrystals (quantum dots, QDs) into a portable microfluidic-based lymphocyte capture and detection device is completed. This integrated system is capable of isolating and counting selected lymphocyte sub-populations (CD3+CD4+) from whole blood samples. By combining the unique optical properties of the QDs with the sample handling capabilities and cost effectiveness of novel microfluidic systems, a practical, portable lymphocyte measurement modality that correlates nicely with flow cytometry (R2 = 0.97) has been developed. This QD-based system reduces the optical requirements significantly relative to molecular fluorophores and the mini-CD4 counting device is projected to be suitable for use in both point-of-need and resource-scarce settings.


Assuntos
Contagem de Linfócito CD4 , Técnicas Analíticas Microfluídicas , Nanopartículas , Sistemas Automatizados de Assistência Junto ao Leito/tendências , Pontos Quânticos , Semicondutores , Linfócitos T/citologia , Animais , Análise Química do Sangue , Humanos , Camundongos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Ratos , Linfócitos T/imunologia
9.
Lab Chip ; 7(8): 995-1003, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17653341

RESUMO

Oral cancer is the sixth most common cancer worldwide and has been marked by high morbidity and poor survival rates that have changed little over the past few decades. Beyond prevention, early detection is the most crucial determinant for successful treatment and survival of cancer. Yet current methodologies for cancer diagnosis based upon pathological examination alone are insufficient for detecting early tumor progression and molecular transformation. To address this clinical need, we have developed a cell-based sensor to detect oral cancer biomarkers, such as the epidermal growth factor receptor (EGFR) whose over-expression is associated with early oral tumorigenesis and aggressive cancer phenotypes. The lab-on-a-chip (LOC) sensor utilizes an embedded track-etched membrane, which functions as a micro-sieve, to capture and enrich cells from complex biological fluids or biopsy suspensions. Once captured, "on-membrane" immunofluorescent assays reveal the presence and isotype of interrogated cells via automated microscopy and fluorescent image analysis. Using the LOC sensor system, with integrated capture and staining technique, EGFR assays were completed in less than 10 minutes with staining intensity, homogeneity, and cellular localization patterns comparable to conventional labeling methods. Further examination of EGFR expression in three oral cancer cell lines revealed a significant increase (p < 0.05) above control cells with EGFR expression similar to normal squamous epithelium. Results obtained in the microfluidic sensor system correlated well with flow cytometry (r(2) = 0.98), the "gold standard" in quantitative protein expression analysis. In addition, the LOC sensor detected significant differences between two of the oral cancer cell lines (p < 0.01), accounting for disparity of approximately 34 000 EGFR per cell according to quantitative flow cytometry. Taken together, these results support the LOC sensor system as a suitable platform for rapid detection of oral cancer biomarkers and characterization of EGFR over-expression in oral malignancies. Application of this technique may be clinically useful in cancer diagnostics for early detection, prognostic evaluation, and therapeutic selection. Having demonstrated the functionality of this integrated microfluidic sensor system, further studies using clinical samples from oral cancer patients are now warranted.


Assuntos
Membrana Celular/metabolismo , Receptores ErbB/biossíntese , Técnicas Analíticas Microfluídicas , Neoplasias Bucais/diagnóstico , Biomarcadores/análise , Linhagem Celular Tumoral , Citometria de Fluxo , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Neoplasias Bucais/metabolismo , Neoplasias Bucais/patologia , Regulação para Cima
10.
Ann N Y Acad Sci ; 1098: 411-28, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17435146

RESUMO

Salivary secretions contain a variety of molecules that reflect important pathophysiological activities. Quantitative changes of specific salivary biomarkers could have significance in the diagnosis and management of both oral and systemic diseases. Modern point-of-care technologies with enhanced detection capabilities are needed to implement a significant advancement in salivary diagnostics. One such promising technology is the recently described lab-on-a-chip (LOC) assay system, in which assays are performed on chemically sensitized beads populated into etched silicon wafers with embedded fluid handling and optical detection capabilities. Using this LOC system, complex assays can be performed with small sample volumes, short analysis times, and markedly reduced reagent costs. This report describes the use of LOC methodologies to assess the levels of interleukin-1beta (IL-1beta), C-reactive protein (CRP), and matrix metalloproteinase-8 (MMP-8) in whole saliva, and the potential use of these biomarkers for diagnosing and categorizing the severity and extent of periodontitis. This study demonstrates that the results achieved by the LOC approach are in agreement with those acquired with standard enzyme-linked immunosorbent assay (ELISA), with significant IL-1beta and MMP-8 elevations in whole saliva of periodontitis patients. Furthermore, because of the superior detection capacities associated with the LOC approach, unlike those with ELISA, significant differences in CRP levels between periodontitis patients and normal subjects are observed. Finally, principal component analysis (PCA) is performed to yield an efficient method to discriminate between periodontally healthy and unhealthy patients, thus increasing the diagnostic value of these biomarkers for periodontitis when examined with the integrated LOC sensor system.


Assuntos
Procedimentos Analíticos em Microchip , Periodontite/diagnóstico , Periodontite/metabolismo , Sistemas Automatizados de Assistência Junto ao Leito , Saliva/química , Biomarcadores/análise , Humanos , Dispositivos Lab-On-A-Chip , Procedimentos Analíticos em Microchip/métodos , Periodontite/enzimologia , Análise de Componente Principal , Saliva/enzimologia
11.
Methods Mol Biol ; 385: 53-64, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18365704

RESUMO

The advent of flow cytometry has considerably changed the ways in which medical testing is conducted. However, the cost of flow cytometers, their large size, and their maintenance needs make them scarce in resource-poor settings and available almost only in clinical pathology laboratories in developed countries. Because cell enumeration is a basic and crucial support of diagnosis, prognosis, and treatment, an alternative cell-counting method that would potentially be cost-effective, portable, and suitable for use in resource-poor settings is warranted. We describe here a protocol for conducting cell-counting experiments in a simple microfluidic structure. This protocol describes how to build a simple microfluidic cell and perform a total white blood cell (WBC) count through capture and immunolabeling of the WBCs with an anti-CD45 antibody.


Assuntos
Contagem de Leucócitos/métodos , Leucócitos/citologia , Citometria de Fluxo , Humanos , Antígenos Comuns de Leucócito/imunologia , Contagem de Leucócitos/instrumentação , Microfluídica/instrumentação , Microfluídica/métodos
12.
Methods Mol Biol ; 385: 131-44, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18365709

RESUMO

The electronic taste chip (ETC) assay system is a lab-on-a-chip technology that offers a microchip platform on which bead-based immunoassays are performed. Each bead within the array serves as its own independent self-contained "microreactor" system, with its selectivity determined by the specificity of the antibody that it hosts. The bead-loaded chip is sandwiched between two optically transparent polymethylmethacrylate inserts, packaged within a metal casing described here as the "flow cell." This flow cell allows for delivery of sample and detecting reagents to the microchip and the associated beads. Images of fluorescent beads are captured with a digital video chip and analyzed to facilitate detection and, ultimately, quantitation of analytes in complex fluids. This chapter describes the application of the ETC system for the detection and measurement of interleukin (IL)-6.


Assuntos
Imunoensaio/métodos , Interleucina-6/análise , Procedimentos Analíticos em Microchip/métodos , Imunoensaio/instrumentação , Dispositivos Lab-On-A-Chip , Microesferas
13.
J Microelectromech Syst ; 15(1): 223-236, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19829760

RESUMO

This paper presents a continuous-flow polymerase chain reaction (PCR) microchip with a serpentine microchannel of varying width for "regional velocity control." Varying the channel width by incorporating expanding and contracting conduits made it possible to control DNA sample velocities for the optimization of the exposure times of the sample to each temperature phase while minimizing the transitional periods during temperature transitions. A finite element analysis (FEA) and semi-analytical heat transfer model was used to determine the distances between the three heating assemblies that are responsible for creating the denaturation (96 degrees C), hybridization (60 degrees C), and extension (72 degrees C) temperature zones within the microchip. Predictions from the thermal FEA and semi-analytical model were compared with temperature measurements obtained from an infrared (IR) camera. Flow-field FEAs were also performed to predict the velocity distributions in the regions of the expanding and contracting conduits to study the effects of the microchannel geometry on flow recirculation and bubble nucleation. The flow fields were empirically studied using micro particle image velocimetry (mu-PIV) to validate the flow-field FEA's and to determine experimental velocities in each of the regions of different width. Successful amplification of a 90 base pair (bp) bacillus anthracis DNA fragment was achieved.

14.
Oral Oncol ; 60: 103-11, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27531880

RESUMO

UNLABELLED: Despite significant advances in surgical procedures and treatment, long-term prognosis for patients with oral cancer remains poor, with survival rates among the lowest of major cancers. Better methods are desperately needed to identify potential malignancies early when treatments are more effective. OBJECTIVE: To develop robust classification models from cytology-on-a-chip measurements that mirror diagnostic performance of gold standard approach involving tissue biopsy. MATERIALS AND METHODS: Measurements were recorded from 714 prospectively recruited patients with suspicious lesions across 6 diagnostic categories (each confirmed by tissue biopsy -histopathology) using a powerful new 'cytology-on-a-chip' approach capable of executing high content analysis at a single cell level. Over 200 cellular features related to biomarker expression, nuclear parameters and cellular morphology were recorded per cell. By cataloging an average of 2000 cells per patient, these efforts resulted in nearly 13 million indexed objects. RESULTS: Binary "low-risk"/"high-risk" models yielded AUC values of 0.88 and 0.84 for training and validation models, respectively, with an accompanying difference in sensitivity+specificity of 6.2%. In terms of accuracy, this model accurately predicted the correct diagnosis approximately 70% of the time, compared to the 69% initial agreement rate of the pool of expert pathologists. Key parameters identified in these models included cell circularity, Ki67 and EGFR expression, nuclear-cytoplasmic ratio, nuclear area, and cell area. CONCLUSIONS: This chip-based approach yields objective data that can be leveraged for diagnosis and management of patients with PMOL as well as uncovering new molecular-level insights behind cytological differences across the OED spectrum.


Assuntos
Dispositivos Lab-On-A-Chip , Monitorização Fisiológica/métodos , Neoplasias Bucais/patologia , Automação , Biópsia/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos
15.
Lab Chip ; 5(3): 261-9, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15726202

RESUMO

In the last decade, saliva has been advocated as a non-invasive alternative to blood as a diagnostic fluid. However, use of saliva has been hindered by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many constituents compared to serum. Furthermore, developments in the areas related to lab-on-a-chip systems for saliva-based point of care diagnostics are complicated by the high viscosity and heterogeneous properties associated with this diagnostic fluid. The biomarker C-reactive protein (CRP) is an acute phase reactant and a well-accepted indicator of inflammation. Numerous clinical studies have established elevated serum CRP as a strong, independent risk factor for the development of cardiovascular disease (CVD). CVD has also been associated with oral infections (i.e. periodontal diseases) and there is evidence that systemic CRP may be a link between the two. Clinical measurements of CRP in serum are currently performed with "high sensitivity" CRP (hsCRP) enzyme-linked immunosorbent assay (ELISA) tests that lack the sensitivity for the detection of this important biomarker in saliva. Because measurement of salivary CRP may represent a novel approach for diagnosing and monitoring chronic inflammatory disease, including CVD and periodontal diseases, the objective of this study was to apply an ultra-sensitive microchip assay system for the measurement of CRP in human saliva. Here, we describe this novel lab-on-a-chip system in its first application for the measurement of CRP in saliva and demonstrate its advantages over the traditional ELISA method. The increased sensitivity of the microchip system (10 pg ml(-1) of CRP with 1000-fold dilution of saliva sample) is attributed to its inherent increased signal to noise ratio, resulting from the higher bead surface area available for antigen/antibody interactions and the high stringency washes associated with this approach. Finally, the microchip assay system was utilized in this study to provide direct experimental evidence that chronic periodontal disease may be associated with higher levels of salivary CRP.


Assuntos
Proteína C-Reativa/análise , Procedimentos Analíticos em Microchip/métodos , Saliva/química , Ensaio de Imunoadsorção Enzimática , Humanos , Dispositivos Lab-On-A-Chip
16.
PLoS Med ; 2(7): e182, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16013921

RESUMO

BACKGROUND: More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. METHODS AND FINDINGS: Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. CONCLUSION: Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.


Assuntos
Contagem de Linfócito CD4 , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD4-Positivos/virologia , Infecções por HIV/sangue , Análise de Sequência com Séries de Oligonucleotídeos/economia , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Algoritmos , Membrana Eritrocítica/virologia , Eritrócitos/virologia , Citometria de Fluxo , Humanos , Processamento de Imagem Assistida por Computador , Microscopia de Fluorescência , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação
17.
Biosens Bioelectron ; 20(10): 2079-88, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15741078

RESUMO

We report here the adaptation of our electronic microchip technology towards the development of a new method for detecting and enumerating bacterial cells and spores. This new approach is based on the immuno-localization of bacterial spores captured on a membrane filter microchip placed within a flow cell. A combination of microfluidic, optical, and software components enables the integration of staining of the bacterial species with fully automated assays. The quantitation of the analyte signal is achieved through the measurement of a collective response or alternatively through the identification and counting of individual spores and particles. This new instrument displays outstanding analytical characteristics, and presents a limit of detection of approximately 500 spores when tested with Bacillus globigii (Bg), a commonly used simulant for Bacillus anthracis (Ba), with a total analysis time of only 5 min. Additionally, the system performed well when tested with real postal dust samples spiked with Bg in the presence of other common contaminants. This new approach is highly customizable towards a large number of relevant toxic chemicals, environmental factors, and analytes of relevance to clinical chemistry applications.


Assuntos
Bacillus/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Contagem de Células/instrumentação , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Espectrometria de Fluorescência/instrumentação , Ultrafiltração/instrumentação , Bacillus/citologia , Técnicas Biossensoriais/métodos , Contagem de Células/métodos , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Imunoensaio/métodos , Membranas Artificiais , Técnicas Analíticas Microfluídicas/métodos , Sistemas On-Line , Óptica e Fotônica/instrumentação , Espectrometria de Fluorescência/métodos , Esporos/citologia , Esporos/isolamento & purificação , Ultrafiltração/métodos
18.
Biosens Bioelectron ; 21(4): 574-80, 2005 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-16202870

RESUMO

This paper presents disposable protein analysis chips with single- or four-chamber-constructed from poly(dimethylsiloxane) (PDMS) and silicon. The chips are composed of a multilayer stack of PDMS layers that sandwich a silicon microchip. This inner silicon chip features an etched array of micro-cavities hosting polymeric beads. The sample is introduced into the fluid network through the top PDMS layer, where it is directed to the bead chamber. After reaction of the analyte with the probe beads, the signal generated on the beads is captured with a CCD camera, digitally processed, and analyzed. An established bead-based fluorescent assay for C-reactive protein (CRP) was used here to characterize these hybrid chips. The detection limit of the single-chamber protein chip was found to be 1 ng/ml. Additionally, using a back pressure compensation method, the signals from each chamber of the four-chamber chip were found to fall within 10% of each other.


Assuntos
Proteína C-Reativa/análise , Proteína C-Reativa/química , Dimetilpolisiloxanos/química , Técnicas Analíticas Microfluídicas/instrumentação , Análise Serial de Proteínas/instrumentação , Silício/química , Silicones/química , Espectrometria de Fluorescência/instrumentação , Equipamentos Descartáveis , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas Analíticas Microfluídicas/métodos , Análise Serial de Proteínas/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos , Integração de Sistemas
19.
RSC Adv ; 5(60): 48194-48206, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26097696

RESUMO

Measuring low concentrations of clinically-important biomarkers using porous bead-based lab-on-a-chip (LOC) platforms is critical for the successful implementation of point-of-care (POC) devices. One way to meet this objective is to optimize the geometry of the bead holder, referred to here as a micro-container. In this work, two geometric micro-containers were explored, the inverted pyramid frustum (PF) and the inverted clipped pyramid frustum (CPF). Finite element models of this bead array assay system were developed to optimize the micro-container and bead geometries for increased pressure, to increase analyte capture in porous bead-based fluorescence immunoassays. Custom micro-milled micro-container structures containing an inverted CPF geometry resulted in a 28% reduction in flow-through regions from traditional anisotropically-etched pyramidal geometry derived from Si-111 termination layers. This novel "reduced flow-through" design resulted in a 33% increase in analyte penetration into the bead and twofold increase in fluorescence signal intensity as demonstrated with C-Reactive Protein (CRP) antigen, an important biomarker of inflammation. A consequent twofold decrease in the limit of detection (LOD) and the limit of quantification (LOQ) of a proof-of-concept assay for the free isoform of Prostate-Specific Antigen (free PSA), an important biomarker for prostate cancer detection, is also presented. Furthermore, a 53% decrease in the bead diameter is shown to result in a 160% increase in pressure and 2.5-fold increase in signal, as estimated by COMSOL models and confirmed experimentally by epi-fluorescence microscopy. Such optimizations of the bead micro-container and bead geometries have the potential to significantly reduce the LODs and reagent costs for spatially programmed bead-based assay systems of this type.

20.
Drug Alcohol Depend ; 153: 306-13, 2015 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-26048639

RESUMO

OBJECTIVE: There is currently a gap in on-site drug of abuse monitoring. Current detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. While remote laboratories then may provide confirmation and quantitative assessment of a presumptive positive, this instrumentation is expensive and decoupled from the initial sampling making the current drug-screening program inefficient and costly. The authors applied a noninvasive oral fluid sampling approach integrated with the in-development chip-based Programmable bio-nano-chip (p-BNC) platform for the detection of drugs of abuse. METHOD: The p-BNC assay methodology was applied for the detection of tetrahydrocannabinol, morphine, amphetamine, methamphetamine, cocaine, methadone and benzodiazepines, initially using spiked buffered samples and, ultimately, using oral fluid specimen collected from consented volunteers. RESULTS: Rapid (∼10min), sensitive detection (∼ng/mL) and quantitation of 12 drugs of abuse was demonstrated on the p-BNC platform. Furthermore, the system provided visibility to time-course of select drug and metabolite profiles in oral fluids; for the drug cocaine, three regions of slope were observed that, when combined with concentration measurements from this and prior impairment studies, information about cocaine-induced impairment may be revealed. CONCLUSIONS: This chip-based p-BNC detection modality has significant potential to be used in the future by law enforcement officers for roadside drug testing and to serve a variety of other settings, including outpatient and inpatient drug rehabilitation centers, emergency rooms, prisons, schools, and in the workplace.


Assuntos
Drogas Ilícitas/análise , Dispositivos Lab-On-A-Chip , Saliva/química , Detecção do Abuso de Substâncias/métodos , Humanos , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA