Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cytotherapy ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38043052

RESUMO

BACKGROUND AIMS: Culture-derived mesenchymal stromal cells (MSCs) exhibit variable characteristics when manufactured using different methods, source material and culture media. The purpose of this multicenter study was to assess the impact on MSC expansion, gene expression and other characteristics when different laboratories expanded MSCs from cultures initiated with bone marrow-MSC aliquots derived from the same donor source material yet with different growth media. METHODS: Eight centers expanded MSCs using four human platelet lysate (HPL) and one fetal bovine serum (FBS) products as media supplements. The expanded cells were taken through two passages then assessed for cell count, viability, doubling time, immunophenotype, cell function, immunosuppression and gene expression. Results were analyzed by growth media and by center. RESULTS: Center methodologies varied by their local seeding density, feeding regimen, inoculation density, base media and other growth media features (antibiotics, glutamine, serum). Doubling times were more dependent on center than on media supplements. Two centers had appropriate immunophenotyping showing all MSC cultures were positive for CD105, CD73, CD90 and negative for CD34, CD45, CD14, HLA-DR. MSCs cultured in media supplemented with FBS compared with HPL featured greater T-cell inhibition potential. Gene expression analysis showed greater impact of the type of media supplement (HPL versus FBS) than the manufacturing center. Specifically, nine genes were decreased in expression and six increased when combining the four HPL-grown MSCs versus FBS (false discovery rate [FDR] <0.01), however, without significant difference between different sources of HPL (FDR <0.01). CONCLUSIONS: Local manufacturing process plays a critical role in MSC expansion while growth media may influence function and gene expression. All HPL and FBS products supported cell growth.

2.
Transfusion ; 63(4): 782-790, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36924403

RESUMO

BACKGROUND: The success of allogeneic hematopoietic stem cell transplantation is dependent on a world-wide network of collection centers providing donations that predominantly have been infused as fresh cells. The logistics chain that supports the just-in-time delivery model for stem cell and immunotherapy products was severely stressed by the COVID pandemic, and in early 2020 a number of national and international bodies recommended that cells should be cryopreserved at the collection or transplant center to avoid interruptions in their acquisition or delivery to patients who had started conditioning. STUDY DESIGN: To assess the potential consequences of such pandemic-related deviations to normal practice, we surveyed nine international laboratories to determine if the characteristics or transplant outcomes of allogeneic stem cell donations differed in the immediate periods before and after the switch to routine cryopreservation. RESULTS: Nine centers on two continents provided data for 72 HSC donations just before, and 71 just after, switching to cryopreservation for allogeneic HSC products. No statistically significant differences between the period before and after cryopreservation were noted for time from product collection to receipt, product temperature at receipt, or CD34+ cell viability at receipt. There was an indication of slower absolute neutrophil count recovery after cryopreservation was required (mean time of 15 vs. 17.6 days). DISCUSSION: While there were no apparent changes to most parameters studied, there was an indication of slower neutrophil engraftment that will need to be examined in larger, longer term studies.


Assuntos
COVID-19 , Transplante de Células-Tronco Hematopoéticas , Humanos , COVID-19/terapia , Células-Tronco Hematopoéticas , Pandemias , Transplante Homólogo
3.
Transfusion ; 62(1): 217-226, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34796962

RESUMO

BACKGROUND: Both M and N alleles encode antigens on Glycophorin A (GPA), a red blood cell (RBC) surface sialoglycoprotein. Interaction between RBC GPA and leukocyte surface lectins may downregulate their activation. The current study investigates if RBC autoantibodies against GPA, such as auto-anti-M/N, prime an activated phenotype in peripheral blood leukocytes. METHODS: Leukocyte activation was assessed in whole blood from patients with auto-anti-GPA (anti-M/N) and compared to those with allo-anti-M/N and healthy subjects. Control samples from healthy subjects with no antibodies incubated in vitro with either anti-GPA or anti-Rh were analyzed for neutrophil and monocyte surface activation marker expression, reactive oxygen species (ROS) content, and formation of aggregates with RBCs. Samples incubated with an IgG1 isotype antibody served as controls. RESULTS: Ex vivo, neutrophil CD66b and monocyte CD63 surface expression was increased in patients with auto-anti-M/N compared to those with allo anti-M/N (p = .1757; p = .0698) and to healthy subjects (p = .0186; p = .013). In vitro, neutrophil CD66b and monocyte CD63 surface expression was increased following incubation with anti-GPA compared to anti-Rh (p = .0003; p = .0328) and isotype control (p = .000; p = .0062). Intracellular ROS content increased in both neutrophils and monocytes incubated with anti-GPA compared to anti-Rh (p = .0012; p = .0693) and isotype control (p = .001; p = .0021). Percentage of neutrophil-RBC aggregates was decreased when incubated with anti-GPA compared to isotype control (p < .01). CONCLUSIONS: Neutrophils and monocytes in peripheral blood exposed to an antibody directed against GPA on RBC surfaces, such as M or N antigens, may be primed towards an activated phenotype.


Assuntos
Antígenos de Grupos Sanguíneos , Glicoforinas , Autoanticorpos , Eritrócitos/metabolismo , Humanos , Leucócitos , Espécies Reativas de Oxigênio/metabolismo
4.
Transfusion ; 62(8): 1595-1601, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35770742

RESUMO

BACKGROUND: The IL-3-pSTAT5 assay, a new, rapid, and standardized flow-cytometry-based assay may compensate for several limitations of the colony-forming unit (CFU) assay typically used for stem cell potency assessments of cord blood units (CBU). We performed an inter-laboratory evaluation of the performance of this new assay. STUDY DESIGN AND METHODS: This Biomedical Excellence for Safer Transfusion (BEST) Collaborative multicenter, international study included 15 participants from public cord blood banks (CBBs), CBB-supporting research laboratories, and stem cell laboratories. To perform the IL-3-pSTAT5 assay, participating centers received reagents, instructions, and 10 blind CBU samples, including eight normal samples and two samples exposed to a transient warming event. We measured inter-laboratory agreement qualitatively (proportion of correctly classified samples) and quantitatively (coefficient of variation [CV], correlation coefficients, receiver operating characteristics (ROC) curve, and intraclass correlation coefficient [ICC]). RESULTS: The qualitative agreement was 97.3% (i.e., 107/110; Fleiss' kappa = 0.835). The average CV on a per-sample basis was 11.57% among all samples, 8.99% among normal samples, and on a per-center basis was 9.42% among normal samples. In a correlation matrix that compared results across centers, the mean Pearson's correlation coefficient was 0.88 (standard deviation = 0.04). The ICC was 0.83 (95% confidence interval = 0.68-0.95). The area under the curve (AUC) from the ROC curve was 0.9974. DISCUSSION: Excellent qualitative and quantitative agreement was exhibited across laboratories. The IL-3-pSTAT5 assay may therefore be implemented in flow cytometry laboratories to rapidly and reliably provide standardized measures of stem cell potency in CBUs.


Assuntos
Sangue Fetal , Interleucina-3 , Armazenamento de Sangue/métodos , Ensaio de Unidades Formadoras de Colônias , Humanos , Fator de Transcrição STAT5/metabolismo , Células-Tronco
5.
Transfusion ; 62(8): 1559-1570, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35808950

RESUMO

BACKGROUND: At the start of the coronavirus disease 2019 (COVID-19) pandemic, widespread blood shortages were anticipated. We sought to determine how hospital blood supply and blood utilization were affected by the first wave of COVID-19. STUDY DESIGN AND METHODS: Weekly red blood cell (RBC) and platelet (PLT) inventory, transfusion, and outdate data were collected from 13 institutions in the United States, Brazil, Canada, and Denmark from March 1st to December 31st of 2020 and 2019. Data from the sites were aligned based on each site's local first peak of COVID-19 cases, and data from 2020 (pandemic year) were compared with data from the corresponding period in 2019 (pre-pandemic baseline). RESULTS: RBC inventories were 3% lower in 2020 than in 2019 (680 vs. 704, p < .001) and 5% fewer RBCs were transfused per week compared to 2019 (477 vs. 501, p < .001). However, during the first COVID-19 peak, RBC and PLT inventories were higher than normal, as reflected by deviation from par, days on hand, and percent outdated. At this time, 16% fewer inpatient beds were occupied, and 43% fewer surgeries were performed compared to 2019 (p < .001). In contrast to 2019 when there was no correlation, there was, in 2020, significant negative correlations between RBC and PLT days on hand and both percentage occupancy of inpatient beds and percentage of surgeries performed. CONCLUSION: During the COVID-19 pandemic in 2020, RBC and PLT inventories remained adequate. During the first wave of cases, significant decreases in patient care activities were associated with excess RBC and PLT supplies and increased product outdating.


Assuntos
COVID-19 , Pandemias , COVID-19/epidemiologia , Transfusão de Eritrócitos , Eritrócitos , Hospitais , Humanos , Estados Unidos
6.
Ann Hematol ; 101(9): 2045-2052, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35763062

RESUMO

Despite the low risk of peripherally inserted central catheter (PICC) insertion-related bleeding, the practice of administering prophylactic platelets varies greatly. Limiting unnecessary blood product transfusions reduces transfusion-related adverse events, financial cost, and delays in care. We assessed the impact of lowering prophylactic platelet administration threshold on blood product utilization patterns and bleeding events. This quasi-experimental study was conducted in an urban academic tertiary medical center. The study population included patients with platelet counts ≥ 10,000/µL and < 50,000/µL undergoing PICC placement in 2018 and 2019 when the minimum platelet thresholds were 50,000/µL and 10,000/µL, respectively. The primary outcome was blood product utilization and the secondary outcome was PICC insertion-related bleeding complications. Thirty-five patients using the 10,000/µL (10 K) platelet threshold and 46 patients using the 50,000/µL (50 K) platelet threshold were enrolled. The 50 K group received more platelets before PICC insertion (0.870 ± 0.885 and 0.143 ± 0.430 pools of platelets-per-person, p < 0.001). No patients experienced clinically significant bleeding. Immediately following PICC insertion, minor bleeding occurred in five patients (two [4.3%] and three [8.6%] in the 50 K and 10 K groups, respectively). Bleeding rates between the two cohorts did not differ (p = 0.647). Lowering the minimum platelet threshold from 50,000/µL to 10,000/µL resulted in less prophylactic platelet and total blood product administration with no appreciable difference in PICC insertion-related bleeding.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Trombocitopenia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Catéteres/efeitos adversos , Hemorragia/complicações , Hemorragia/prevenção & controle , Humanos , Contagem de Plaquetas , Transfusão de Plaquetas/efeitos adversos , Trombocitopenia/etiologia
7.
Transfusion ; 61(8): 2414-2420, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34181247

RESUMO

BACKGROUND: In the setting of suspected septic transfusion reactions, bacterial culture of both the transfused patient and the residual blood component is recommended. Primary bacterial contamination can occur at the time of component collection. Clinically insignificant "secondary contamination" can occur during post-transfusion component discard, retrieval for culture, or manipulation of the bag at the time of culture sampling. STUDY DESIGN AND METHODS: This retrospective, multi-center study analyzes positive residual component culture results and companion patient blood cultures from 15 hospitals, 1 blood center, and all cultured transfusion reactions within the province of Quebec, Canada, over a 5-year period. Imputability was assigned as "definite" (concordant growth), "possible" (discordant growth or lack of growth in patient culture), or "unable to assess" (patient not cultured). RESULTS: There were 373 positive component cultures from 360 unique transfusion reactions, with 276 (76.7%) companion patient blood cultures performed, of which 10 (2.8%) yielded the pathogen detected in the positive component. Of these 10 definite pathogens, 7 (2 Staphylococcus aureus, 3 other staphylococci, and 1 Streptococcus pyogenes and 1 Bacillus sp.) were associated with platelet and 3 (Aeromonas veronii, Staphylococcus epidermidis, and Enterococcus faecalis) with RBC transfusions. RBC and plasma components comprised 70% of positive component cultures. DISCUSSION: The process of performing residual component culture is vulnerable to secondary contamination. The significance of microorganisms recovered from component culture cannot be interpreted in isolation. In the context of low prevalence of primary contamination of blood components, the positive predictive value of a positive component culture result is very low.


Assuntos
Bactérias/isolamento & purificação , Infecções Bacterianas/etiologia , Transfusão de Componentes Sanguíneos/efeitos adversos , Segurança do Sangue , Sepse/etiologia , Reação Transfusional/etiologia , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Hemocultura , Estudos Transversais , Humanos , Estudos Retrospectivos , Sepse/diagnóstico , Sepse/microbiologia , Reação Transfusional/diagnóstico , Reação Transfusional/microbiologia
8.
Cytotherapy ; 22(6): 337-342, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32223996

RESUMO

BACKGROUND AIMS: At the frontier of transfusion medicine and transplantation, the field of cellular therapy is emerging. Most novel cellular therapy products are produced under investigational protocols with no clear standardization across cell processing centers. Thus, the purpose of this study was to uncover any variations in manufacturing practices for similar cellular therapy products across different cell processing laboratories worldwide. METHODS: An exploratory survey that was designed to identify variations in manufacturing practices in novel cellular therapy products was sent to cell processing laboratory directors worldwide. The questionnaire focused on the manufacturing life cycle of different cell therapies (i.e., collection, purification, in vitro expansion, freezing and storage, and thawing and washing), as well as the level of regulations followed to process each product type. RESULTS: The majority of the centers processed hematopoietic progenitor cells (HPCs) from peripheral blood (n = 18), bone marrow (n = 16) or cord blood (n = 19), making HPCs the most commonly processed cells. The next most commonly produced cellular therapies were lymphocytes (n = 19) followed by mesenchymal stromal cells (n = 14), dendritic cells (n = 9) and natural killer (NK) cells (n = 9). A minority of centers (<5) processed pancreatic islet cells (n = 4), neural cells (n = 3) and induced-pluripotent stem cells (n = 3). Thirty-two laboratories processed products under an investigational status, for either phase I/II (n = 27) or phase III (n = 17) clinical trials. If purification methods were used, these varied for the type of product processed and by institution. Environmental monitoring methods also varied by product type and institution. CONCLUSION: This exploratory survey shows a wide variation in cellular therapy manufacturing practices across different cell processing laboratories. A better understanding of the effect of these variations on the quality of these cell-based therapies will be important to assess for further process evaluation and development.


Assuntos
Biotecnologia/métodos , Terapia Baseada em Transplante de Células e Tecidos/métodos , Biotecnologia/normas , Medula Óssea , Sangue Fetal , Células-Tronco Hematopoéticas , Humanos , Células Matadoras Naturais , Laboratórios/normas , Células-Tronco Mesenquimais
9.
Transfusion ; 60 Suppl 3: S45-S52, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32478953

RESUMO

BACKGROUND: Whole blood (WB) is rapidly emerging as the treatment modality of choice for the initial resuscitation of civilian trauma patients across the United States. The reemergence of WB has been rapid and driven in part by recognition of the importance of early plasma transfusion in the resuscitation process. STUDY DESIGN AND METHODS: The study was designed as a critical analysis of the available literature on WB transfusion in civilian trauma patients. Studies were included if they reported on transfusion of cold-stored WB used in a civilian setting and measured safety, feasibility, or a direct clinical outcome. RESULTS: Examination of the available literature supports the feasibility and safety of WB used in treatment of civilian trauma patients. The evidence regarding clinical outcomes, particularly with direct comparison to equivalent doses of component therapy, is more limited. The literature is predominantly descriptive and retrospective in nature and limited by the heterogeneity of clinical WB protocols being used. Based on this limited data set, there are limited conclusions that can be used to definitely support or refute the clinical superiority of WB to component therapy. CONCLUSION: Current literature supports the safety and feasibility of WB, but prospective randomized trials comparing WB to component therapy are needed to provide the definitive evidence on this topic.


Assuntos
Transfusão de Sangue/métodos , Ressuscitação , Ferimentos e Lesões/terapia , Sistema ABO de Grupos Sanguíneos , Temperatura Baixa , Bases de Dados Factuais , Humanos , Ferimentos e Lesões/mortalidade
10.
Transfusion ; 60(8): 1811-1820, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32654200

RESUMO

BACKGROUND: Growth in size and complexity of clinical hematopoietic progenitor cell (HPC) transplant programs necessitates parallel increases in cellular therapy laboratory (CTL) workload. Typically individually developed, HPC product processing is labor and time intensive. Variation in procedure type and numbers across CTLs complicates direct comparisons, and benchmark data are not readily available. STUDY DESIGN AND METHODS: Studies were undertaken at seven CTLs. Transplant volume and staff numbers were determined. Staff recorded time performing tasks broken down into steps: paperwork, product acceptance, transport/infusion, processing, and cryopreservation. Times were added to obtain total times for 15 common CTL procedures. RESULTS: Annual transplant volume ranged from 53.4 to 463.2, with products processed by a range of 2 to 10 dedicated CTL staff. Paperwork time constituted 23.7% to 62.3% total time; product processing time accounted for 1.8 (for National Marrow Donor Program product receipt) to 62.6% (for red blood cell reduction of allogeneic HPC products from bone marrow) of total processing time. Mean time for 15 procedures ranged from 1.27 to 8.28 hours (standard deviation range, 0.35-2.71 hr). Mean time for products from bone marrow versus peripheral blood was 6.6 ± 2.0 versus 5.5 ± 1.1 hours (p = 0.02). Cryopreservation (6.5 ± 1.6 vs. 4.4 ± 0.85 hr; p < 0.01) and manipulation (6.4 ± 1.5 vs. 4.4 ± 0.85 hr; p < 0.01) added time. CONCLUSION: CTL procedures are time intensive, with wide intra- and inter-CTL variation. Paperwork accounted for substantial portion of total time across procedures. Bone marrow source, cryopreservation, and manipulation contributed to longer times. These findings provide concrete data on which to build regarding CTL workload capacity.


Assuntos
Transplante de Medula Óssea , Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas , Laboratórios Hospitalares , Carga de Trabalho , Aloenxertos , Humanos
11.
Transfusion ; 59(7): 2292-2300, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31013368

RESUMO

BACKGROUND: Culturing residual blood components after suspected septic transfusion reactions guides management of patients and cocomponents. Current practice, accuracy of provider vital sign assessment, and performance of the AABB culture criteria are unknown. A multicenter international study was undertaken to investigate these issues and develop improved culture criteria. STUDY DESIGN AND METHODS: Retrospective data for all transfusion reactions resulting in residual blood component culture in 2016 were collected from participating hospitals. The performance of the AABB culture criteria were assessed for detection of positive culture results. Modifications to the AABB criteria including 1) recommending culturing in the setting of isolated high fevers, 2) defining hypotension and tachycardia using objective parameters, and 3) incorporating antipyretic use were tested to determine if modifications improved performance. Modifications associated with improvement were incorporate into the BEST criteria. The AABB and the BEST criteria were then tested against a data set enriched for positive culture results to determine which criteria were superior. RESULTS: Data were collected from 20 centers encompassing 779,143 transfusions, 3,187 reported transfusion reactions, and 1,104 cultured components. There was marked variation in reaction reporting and culturing rates (0.0%-100.0%). Of 35 total positive component cultures, only one of 35 (2.9%) had concordant patient cultures; 12 of 34 (35.3%) did not have patient cultures performed. The BEST criteria had better sensitivity for detection of a positive culture result compared to the AABB criteria (74% vs. 41%), although specificity decreased (45% vs. 65%). CONCLUSION: Compared to the AABB criteria, the BEST criteria have improved sensitivity for positive culture detection.


Assuntos
Transfusão de Componentes Sanguíneos , Hemocultura , Reação Transfusional , Estudos Transversais , Humanos , Estudos Retrospectivos , Reação Transfusional/epidemiologia , Reação Transfusional/microbiologia
12.
Transfusion ; 58(9): 2184-2191, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30204955

RESUMO

BACKGROUND: Viability testing is a common practice in laboratories. The goal of this study was to ascertain current laboratory practices internationally for performing viability testing for cryopreserved cord blood (CB) products and glean information about how to standardize the method to improve interlaboratory reproducibility. STUDY DESIGN AND METHODS: A survey to evaluate current laboratory practices for viability testing was designed and distributed internationally. The question topics included sampling and testing methods, responses to unexpected results, and the rating of the reliability of the CB quality tests, together with expectations for standardization. RESULTS: There were 32 respondents to the survey, of whom 28 responded to the more detailed questionnaire about viability methods. Overall, responses indicated that various stains were used among the laboratories, and when multiple sites used the same viability stain the methods differed. The majority of the respondents were in favor of standardizing the viability testing methods. A wide variety of preferences were communicated about how to standardize the method, but a majority did advocate the use of 7-aminoactinomycin D (7-AAD) with flow cytometry. CONCLUSIONS: The survey results revealed a variety of tests and inconsistent interlaboratory practices for performing the viability assay. Flow cytometry with a 7-AAD dye was suggested as a first step toward standardization.


Assuntos
Preservação de Sangue/métodos , Segurança do Sangue , Transplante de Células-Tronco de Sangue do Cordão Umbilical , Criopreservação/métodos , Sangue Fetal/citologia , Células-Tronco Hematopoéticas/citologia , Núcleo Celular/ultraestrutura , Separação Celular/métodos , Sobrevivência Celular , Transplante de Células-Tronco de Sangue do Cordão Umbilical/métodos , Transplante de Células-Tronco de Sangue do Cordão Umbilical/normas , Dactinomicina/análogos & derivados , Citometria de Fluxo/métodos , Corantes Fluorescentes , Pesquisas sobre Atenção à Saúde , Células-Tronco Hematopoéticas/ultraestrutura , Humanos , Recém-Nascido , Cooperação Internacional , Internet , Laboratórios/normas , Utilização de Procedimentos e Técnicas , Reprodutibilidade dos Testes
13.
Transfusion ; 57(11): 2639-2648, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28880378

RESUMO

BACKGROUND: Allergic transfusion reactions are drawbacks to the benefits of transfusion. Classically, allergic transfusion reactions depend on histamine release from mast cells or basophils, but other leukocyte subsets may also be important. Thus, we propose to better define the exact leukocyte subsets involved in allergic transfusion reactions. STUDY DESIGN AND METHODS: The overall objective of the current study was to compare the activation of specific peripheral blood leukocyte subsets (monocytes, neutrophils, eosinophils, and basophils) in a cohort of 13 patients who received chronic transfusions and had a history of allergic transfusion reactions compared with a control group of patients who received chronic transfusions and had no history of allergic transfusion reactions. Leukocyte subsets were analyzed by flow cytometry at baseline and after red blood cell transfusion, and cytokine levels in platelet-free plasma collected at the same time points were measured by Luminex assay. RESULTS: Flow cytometry and cytokine profiles before and after transfusion did not differ significantly between patients who did and did not have a history of allergic transfusion reactions (p > 0.05). However, post-transfusion samples from both groups showed a decrease in CD63 expression in basophils, monocytes, and eosinophils and a decrease in CD45 expression in all leukocyte subsets compared with pretransfusion samples. Interleukin 10 levels increased after transfusion in the group with a history of allergic transfusion reactions (p = 0.0469), and RANTES (regulated upon activation, normal T-cell expressed and secreted) was significantly decreased post-transfusion in all patients (p = 0.0122). CONCLUSION: None of the leukocyte subsets from patients who had a history of allergic transfusion reactions significantly increased in activation either before or after transfusion. All leukocyte subsets from patients who did and did not have a history of allergic transfusion reactions decreased in their activation profile upon transfusion challenge.


Assuntos
Hipersensibilidade , Transfusão de Leucócitos/efeitos adversos , Leucócitos/metabolismo , Plasma/metabolismo , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Antígenos Comuns de Leucócito/análise , Leucócitos/citologia , Ativação Linfocitária , Masculino , Plasma/citologia , Tetraspanina 30/análise , Adulto Jovem
14.
Transfusion ; 57(10): 2348-2354, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28782120

RESUMO

BACKGROUND: Transfusion-transmitted babesiosis (TTB) has been rapidly increasing in incidence since the beginning of the 21st century. Asymptomatic individuals with Babesia infection are able to donate blood in the United States because of the lack of specific blood donation testing. Blood products collected in Babesia-endemic areas are distributed nationally; thus, clinicians in nonendemic states may fail to include babesiosis in the differential diagnosis of a patient who had a recent transfusion history and a fever of unknown origin. STUDY DESIGN AND METHODS: We report the details of two cases of clinical transfusion-transmitted babesiosis and one asymptomatic infection identified in red blood cell recipients in two nonendemic states (South Carolina and Maryland), which, when combined with three recent additional cases in nonendemic states, totals six recipient infections in three nonendemic states. RESULTS: Delayed diagnosis of transfusion-transmitted babesiosis places patients at risk for increased morbidity and mortality and may result in clinical mismanagement or unnecessary treatments. A peripheral blood smear should be reviewed in any patient with a recent transfusion and a fever of unknown origin. Prompt communication of the diagnosis among physicians is key to ensuring that patients with transfusion-transmitted babesiosis are treated expeditiously, and a transfusion service investigation is necessary to identify additional recipients from the same donor. CONCLUSION: TTB is appearing in traditionally nonendemic states because of blood product distribution patterns. Clinicians should include TTB on the differential diagnosis in any patient presenting who had a recent transfusion history and a fever of unknown origin, regardless of where the transfusion took place.


Assuntos
Babesiose/transmissão , Reação Transfusional , Adulto , Antibacterianos/uso terapêutico , Babesiose/diagnóstico , Doadores de Sangue , Diagnóstico Diferencial , Transfusão de Eritrócitos , Febre/etiologia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Lactente , Masculino , Estados Unidos
15.
Transfusion ; 57(2): 357-366, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28019009

RESUMO

BACKGROUND: Red blood cell transfusion related to select surgical procedures accounts for approximately 2.8 million transfusions in the United States yearly and occurs commonly after hip fracture surgeries. Randomized controlled trials have demonstrated lack of clinical benefit with higher versus lower transfusion thresholds in postoperative hip fracture repair patients with cardiac disease or risk factors for cardiac disease. The economic implications of a higher versus lower hemoglobin (Hb) threshold have not yet been investigated. STUDY DESIGN AND METHODS: A decision tree analysis was constructed to estimate differences in healthcare costs and charges between a Hb transfusion threshold strategy of 8 g/dL versus 10 g/dL from the perspective of both Centers for Medicare and Medicaid Services (CMS) as well as hospitals. Secondary outcome measures included differences in transfusion-related adverse events. RESULTS: Among the 133,697 Medicare beneficiaries undergoing hip fracture repair in 2012, we estimated that 45,457 patients would be anemic and at risk for transfusion. CMS would save an estimated $11.3 million to $24.3 million in payments, while hospitals would reduce charges by an estimated $52.7 million to $93.6 million if the restrictive transfusion strategy were to be implemented nationally. Additionally, rates of transfusion-associated circulatory overload, transfusion-related acute lung injury, acute transfusion reactions, length of stay, and mortality would be reduced. CONCLUSIONS: This model suggests that the uniform adoption of a restrictive transfusion strategy among patients with cardiac disease and risk factors for cardiac disease undergoing hip fracture repair would result in significant reductions in clinically important outcomes with significant cost savings.


Assuntos
Tomada de Decisões , Transfusão de Eritrócitos/economia , Fraturas do Quadril/economia , Fraturas do Quadril/cirurgia , Modelos Econômicos , Custos e Análise de Custo , Feminino , Cardiopatias/economia , Cardiopatias/terapia , Humanos , Masculino , Medicaid , Medicare , Fatores de Risco , Estados Unidos
18.
Transfusion ; 55(12): 2783-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26448376

RESUMO

BACKGROUND: Plasma volume reduction (PVR) may reduce the risk of hemolysis associated with transfusion of plateletpheresis blood products (PLTs) containing ABO-incompatible plasma. But PVR may delay PLT issue. In collaboration with our blood donor center we evaluated an automated screen of PLT for high-titer ABO antibody and to apply PVR to high-titer PLTs. STUDY DESIGN AND METHODS: At the donor center, plasma from PLT donors was tested using an automated microplate system (PK7300, Beckman). PK settings were set for a detection cutoff equivalent to 1 in 256 using a manual tube method. The donors associated with high-titer PLTs were characterized by sex and age. In the transfusion service, the number of PVR procedures was evaluated before and after implementation of the high-titer screen. RESULTS: During validation, 157 of 1008 PLT units (15%) were positive by the automated method versus 121 (12%) by manual method. After implementation, 2112 of 15,240 PLT units were high-titer, with higher frequency in donations from females versus males (18% vs. 12%, p < 0.0001). The PLT PVR rate was reduced by 50%. CONCLUSION: Implementation of an automated method to screen PLTs for high-titer ABO antibody at the donor center improves the inventory management of PLTs containing ABO-incompatible plasma at the hospital transfusion service.


Assuntos
Sistema ABO de Grupos Sanguíneos/imunologia , Incompatibilidade de Grupos Sanguíneos/diagnóstico , Plaquetas/imunologia , Isoanticorpos/sangue , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Plasmático
19.
Transfusion ; 55(6): 1331-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25823522

RESUMO

BACKGROUND: The Pragmatic, Randomized Optimal Platelets and Plasma Ratios (PROPPR) trial was a randomized clinical trial comparing survival after transfusion of two different blood component ratios for emergency resuscitation of traumatic massive hemorrhage. Transfusion services supporting the study were expected to provide thawed plasma, platelets, and red blood cells within 10 minutes of request. STUDY DESIGN AND METHODS: At the 12 Level 1 trauma centers participating in PROPPR, blood components transfused and delivery times were tabulated, with a focus on universal donor (UD) plasma management. The adequacy of site plans was assessed by comparing the bedside blood availability times to study goals and the new American College of Surgeons guidelines. RESULTS: Eleven of 12 sites were able to consistently deliver 6 units of thawed UD plasma to their trauma-receiving unit within 10 minutes and 12 units in 20 minutes. Three sites used blood group A plasma instead of AB for massive transfusion without complications. Approximately 4700 units of plasma were given to the 680 patients enrolled in the trial. No site experienced shortages of AB plasma that limited enrollment. Two of 12 sites reported wastage of thawed AB plasma approaching 25% of AB plasma prepared. CONCLUSION: Delivering UD plasma to massively hemorrhaging patients was accomplished consistently and rapidly and without excessive wastage in high-volume trauma centers. The American College of Surgeons Trauma Quality Improvement Program guidelines for massive transfusion protocol UD plasma availability are practicable in large academic trauma centers. Use of group A plasma in trauma resuscitation needs further study.


Assuntos
Transfusão de Componentes Sanguíneos , Hemorragia/terapia , Estudos Multicêntricos como Assunto/estatística & dados numéricos , Plasma , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Ferimentos e Lesões/complicações , Sistema ABO de Grupos Sanguíneos/sangue , Bancos de Sangue/estatística & dados numéricos , Transfusão de Componentes Sanguíneos/estatística & dados numéricos , Preservação de Sangue , Criopreservação , Feminino , Hemorragia/etiologia , Humanos , Masculino , Ressuscitação , Fatores de Tempo , Centros de Traumatologia/estatística & dados numéricos , Estados Unidos , Armazenamento de Sangue/métodos
20.
J Clin Apher ; 30(6): 340-6, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25739580

RESUMO

Blood group incompatibility remains a significant barrier to kidney transplantation. Approximately, one-third of donors are blood group incompatible with their intended recipient. Options for these donor-recipient pairs include blood group incompatible transplantation or kidney paired donation. However, the optimal protocol for blood group incompatible transplantation is unknown. Protocols differ in techniques to remove ABO antibodies, titer targets, and immunosuppression regimens. In addition, the mechanisms of graft accommodation to blood group antigens remain poorly understood. We describe a blood group incompatible protocol using pretransplant therapeutic plasma exchange (TPE), high-dose intravenous immunoglobulin, and rituximab in addition to prednisone, mycophenolate mofetil, and tacrolimus. In this protocol, we do not exclude patients based on a high initial titer and do not implement post-transplant TPE. All 16 patients who underwent this protocol received a living donor transplant with 100% patient and graft survival, and no reported episodes of antibody-mediated rejection to date with a median follow-up of 2.6 years (range 0.75-4.7 years). We conclude that blood group incompatible transplantation can be achieved without post-transplant TPE.


Assuntos
Sistema ABO de Grupos Sanguíneos , Incompatibilidade de Grupos Sanguíneos , Transplante de Rim/métodos , Doadores Vivos , Adulto , Idoso , Incompatibilidade de Grupos Sanguíneos/imunologia , Protocolos Clínicos , Feminino , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto , Humanos , Imunoglobulinas Intravenosas/uso terapêutico , Imunossupressores/uso terapêutico , Isoanticorpos/sangue , Transplante de Rim/efeitos adversos , Masculino , Pessoa de Meia-Idade , Troca Plasmática , Rituximab/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA