Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 49(2): 539-548, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36336551

RESUMO

Surgical intervention for the treatment of intracerebral hemorrhage (ICH) has been limited by inadequate lysis of the target thrombus. Adjuvant transcranial ultrasound exposure is hypothesized to improve thrombolysis, expedite hematoma evacuation and improve clinical outcomes. A juvenile porcine intracerebral hemorrhage model was established by direct infusion of autologous blood into the porcine white matter. Thrombi were either not treated (sham) or treated with recombinant tissue plasminogen activator alone (rt-PA only) or in combination with pulsed transcranial 120-kHz ultrasound (sonothrombolysis). After treatment, pigs were euthanized, the heads frozen and sectioned and the thrombi extracted. D-Dimer and thrombus density assays were used to assess degree of lysis. Both porcine and human D-dimer assays tested did not have sufficient sensitivity to detect porcine D-dimer. Thrombi treated with rt-PA with or without 120-kHz ultrasound had a significantly lower density compared with sham-treated thrombi. No enhancement of rt-PA-mediated thrombolysis was noted with the addition of 120-kHz ultrasound (sonothrombolysis). The thrombus density assay revealed thrombolytic efficacy caused by rt-PA in an in vivo juvenile porcine model of intracerebral hemorrhage. Transcranial sonothrombolysis did not enhance rt-PA-induced thrombolysis, likely because of the lack of exogenous cavitation nuclei.


Assuntos
Trombose , Ativador de Plasminogênio Tecidual , Animais , Humanos , Hemorragia Cerebral/terapia , Fibrinolíticos/uso terapêutico , Suínos , Terapia Trombolítica , Trombose/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Ativador de Plasminogênio Tecidual/farmacologia
2.
Sci Rep ; 11(1): 3987, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-33597659

RESUMO

Adjuvant ultrasound at 2 MHz with or without an ultrasound contrast agent improves the rate of thrombus resolution by recombinant tissue plasminogen activator (rt-PA) in laboratory and clinical studies. A sub-megahertz approach can further expand this therapy to a subset of patients with an insufficient temporal bone window, improving efficacy in unselected patient populations. The aim of this study was to determine if a clinical ultrasound contrast agent (UCA), Definity, and 220 kHz pulsed ultrasound accelerated rt-PA thrombolysis in a preclinical animal model of vascular occlusion. The effect of Definity and ultrasound on thrombus clearance was first investigated in vitro and subsequently tested in a xenographic porcine cerebral thromboembolism model in vivo. Two different microcatheter designs (end-hole, multi-side-hole) were used to infuse rt-PA and Definity at the proximal edge or directly into clots, respectively. Sonothrombolysis with Definity increased clot mass loss relative to saline or rt-PA alone in vitro, only when rt-PA was administered directly into clots via a multi-side-hole microcatheter. Combined treatment with rt-PA, Definity, and ultrasound in vivo increased the rate of reperfusion up to 45 min faster than clots treated with rt-PA or saline. In this porcine cerebral thromboembolism model employing retracted human clots, 220 kHz ultrasound, in conjunction with Definity increased the probability of early successful reperfusion with rt-PA.


Assuntos
Terapia Combinada/métodos , Fibrinolíticos/farmacologia , Tromboembolia/terapia , Terapia Trombolítica/métodos , Terapia por Ultrassom/métodos , Animais , Meios de Contraste/uso terapêutico , Xenoenxertos , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Suínos , Tromboembolia/diagnóstico por imagem , Trombose/metabolismo , Ativador de Plasminogênio Tecidual/farmacologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA