Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Exp Ophthalmol ; 50(5): 490-499, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35420244

RESUMO

BACKGROUND: To investigate repair of iris defects by endocapsular implantation of an artificial iris, in relation to visual outcomes, safety profile and patient satisfaction. METHODS: Retrospective, consecutive case series from Greenlane tertiary teaching hospital and Eye Institute, Auckland, New Zealand. Medical records of patients implanted with an endocapsular artificial iris were reviewed and followed for minimum 3 months. Patient characteristics, surgical management, clinical outcomes and subjective responses were recorded. RESULTS: Nineteen artificial irises were implanted in 18 patients. Etiologies were iris melanotic lesion excision (73.7%), trauma (10.5%), congenital aniridia (10.5%) and Urrets-Zavalia syndrome (5.3%). During postoperative follow-up [14.1 ± 12.4 months (range: 3 to 59 months)], best corrected visual acuity (BCVA) and intraocular pressure (IOP) did not change significantly [BCVA, 0.23 logarithm of the minimum angle of resolution (logMAR) (20/32 Snellen) preoperatively vs. 0.18 logMAR postoperatively (20/25 Snellen) (Z = -0.222, p = 0.824); IOP, 15 mmHg preoperatively vs. 17 mmHg postoperatively (Z = 1.377, p = 0.1447)]. Mild or self-limiting complications included: elevated IOP (42.1%), cystoid macular oedema (15.8%); persisting postoperative uveitis (15.8%) and minor vaulting of the prosthesis (15.7%). Moderate or severe complications included significant vaulting of prosthesis requiring surgical revision (5.3%) and a single eye (5.3%) with trabeculectomy and corneal graft failure. 94.4% of patients were very satisfied with the cosmesis and would be highly likely to have the procedure again. CONCLUSIONS: This study confirms that endocapsular insertion of an artificial iris is typically associated with good functional and cosmetic results and a relatively low risk of significant complications.


Assuntos
Aniridia , Lentes Intraoculares , Aniridia/cirurgia , Humanos , Iris/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Implantação de Prótese , Estudos Retrospectivos , Acuidade Visual
2.
Clin Exp Ophthalmol ; 48(6): 739-748, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32335997

RESUMO

IMPORTANCE: Improving the representation of indigenous ophthalmologists in New Zealand. BACKGROUND: Maori, indigenous to New Zealand/Aotearoa and Pacific Peoples indigenous to Pacific Island Nations living in New Zealand, experience poorer health outcomes across several ophthalmic conditions. The Royal Australian and New Zealand College of Ophthalmologists have identified indigenous workforce development as a priority. DESIGN: Mixed-methods study, utilizing retrospective analysis of Medical Schools Outcomes Database and Longitudinal Tracking Project responses, and prospective interviews with Maori/Pasifika medical graduates. PARTICIPANTS: This study involved 64 medical graduates from the University of Auckland (UoA) and the University of Otago, and six Maori/Pasifika medical postgraduates in New Zealand. METHODS: Retrospective analysis of medical graduate responses who ranked ophthalmology among their top-three preferred specialties in the Medical Schools Outcomes Database and Longitudinal Tracking Project. Prospective semi-structured interviews with Maori/Pasifika medical postgraduates. MAIN OUTCOME MEASURES: Specialty training influencing factors and prevocational ophthalmology experience. RESULTS: A total of 64 (6.7%) out of 954 medical graduates from the UoA and University of Otago ranked ophthalmology among their top-three preferred training specialties (2012-2017). Of the 64 graduates, six (9.3%) identified as Maori/Pasifika. No significant difference in influencing factors between Maori/Pasifika and non-Maori/Pasifika students was identified. Both groups ranked intellectual content, procedural skills, specialty exposure and mentorship as highly influential. Qualitative interviews with Maori/Pasifika graduates highlighted positive experiences in ophthalmology but limited exposure overall. Negative anecdotes and unclear training pathways discouraged Maori/Pasifika interest in Ophthalmology training. CONCLUSIONS AND RELEVANCE: Maori/Pasifika graduate interest in ophthalmology training was relatively low. Valuable insights include enhancing specialty exposure, mentor development, promoting Maori/Pasifika connections and clarifying training pathways for future graduates.


Assuntos
Oftalmologia , Austrália , Humanos , Havaiano Nativo ou Outro Ilhéu do Pacífico , Nova Zelândia , Estudos Prospectivos , Estudos Retrospectivos
3.
Clin Exp Ophthalmol ; 48(9): 1168-1174, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32949452

RESUMO

IMPORTANCE: Determine phacoemulsification cataract surgery risk in a Covid-19 era. BACKGROUND: SARS-CoV-2 (Covid-19) transmission via microdroplet and aerosol-generating procedures presents risk to medical professionals. As the most common elective surgical procedure performed globally; determining contamination risk from phacoemulsification cataract surgery may guide personal protection equipment use. DESIGN: Pilot study involving phacoemulsification cataract surgery on enucleated porcine eyes by experienced ophthalmologists in an ophthalmic operating theatre. PARTICIPANTS: Two ophthalmic surgical teams. METHODS: Standardized phacoemulsification of porcine eyes by two ophthalmologists accompanied by an assistant. Fluorescein incorporated into phacoemulsification irrigation fluid identifying microdroplets and spatter. Contamination documented using a single-lens reflex camera with a 532 nm narrow bandpass (fluorescein) filter, in-conjunction with a wide-field blue light and flat horizontal laser beam (wavelength 532 nm). Quantitative image analysis using Image-J software. MAIN OUTCOME MEASURES: Microdroplet and spatter contamination from cataract phacoemulsification. RESULTS: With phacoemulsification instruments fully within the eye, spatter contamination was limited to <10 cm. Insertion and removal of the phacoemulsification needle and bimanual irrigation/aspiration, with irrigation active generated spatter on the surgeons' gloves and gown extending to >16 cm below the neckline in surgeon 1 and > 5.5 cm below the neckline of surgeon 2. A small tear in the phacoemulsification irrigation sleeve, presented a worse-case scenario the greatest spatter. No contamination above the surgeons' neckline nor contamination of assistant occurred. CONCLUSIONS AND RELEVANCE: Cataract phacoemulsification generates microdroplets and spatter. Until further studies on SARS-CoV-2 transmission via microdroplets or aerosolisation of ocular fluid are reported, this pilot study only supports standard personal protective equipment.


Assuntos
COVID-19/epidemiologia , Catarata/epidemiologia , Transmissão de Doença Infecciosa/estatística & dados numéricos , Contaminação de Equipamentos/estatística & dados numéricos , Facoemulsificação/efeitos adversos , SARS-CoV-2 , Comorbidade , Feminino , Humanos , Período Intraoperatório , Masculino , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA