Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nature ; 619(7971): 724-732, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37438522

RESUMO

The presence and distribution of preserved organic matter on the surface of Mars can provide key information about the Martian carbon cycle and the potential of the planet to host life throughout its history. Several types of organic molecules have been previously detected in Martian meteorites1 and at Gale crater, Mars2-4. Evaluating the diversity and detectability of organic matter elsewhere on Mars is important for understanding the extent and diversity of Martian surface processes and the potential availability of carbon sources1,5,6. Here we report the detection of Raman and fluorescence spectra consistent with several species of aromatic organic molecules in the Máaz and Séítah formations within the Crater Floor sequences of Jezero crater, Mars. We report specific fluorescence-mineral associations consistent with many classes of organic molecules occurring in different spatial patterns within these compositionally distinct formations, potentially indicating different fates of carbon across environments. Our findings suggest there may be a diversity of aromatic molecules prevalent on the Martian surface, and these materials persist despite exposure to surface conditions. These potential organic molecules are largely found within minerals linked to aqueous processes, indicating that these processes may have had a key role in organic synthesis, transport or preservation.

2.
Proc Natl Acad Sci U S A ; 117(41): 25310-25318, 2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-32989146

RESUMO

The origin of diamonds in ureilite meteorites is a timely topic in planetary geology as recent studies have proposed their formation at static pressures >20 GPa in a large planetary body, like diamonds formed deep within Earth's mantle. We investigated fragments of three diamond-bearing ureilites (two from the Almahata Sitta polymict ureilite and one from the NWA 7983 main group ureilite). In NWA 7983 we found an intimate association of large monocrystalline diamonds (up to at least 100 µm), nanodiamonds, nanographite, and nanometric grains of metallic iron, cohenite, troilite, and likely schreibersite. The diamonds show a striking texture pseudomorphing inferred original graphite laths. The silicates in NWA 7983 record a high degree of shock metamorphism. The coexistence of large monocrystalline diamonds and nanodiamonds in a highly shocked ureilite can be explained by catalyzed transformation from graphite during an impact shock event characterized by peak pressures possibly as low as 15 GPa for relatively long duration (on the order of 4 to 5 s). The formation of "large" (as opposed to nano) diamond crystals could have been enhanced by the catalytic effect of metallic Fe-Ni-C liquid coexisting with graphite during this shock event. We found no evidence that formation of micrometer(s)-sized diamonds or associated Fe-S-P phases in ureilites require high static pressures and long growth times, which makes it unlikely that any of the diamonds in ureilites formed in bodies as large as Mars or Mercury.

3.
Appl Spectrosc ; : 37028241280081, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39359239

RESUMO

The Perseverance rover landed at Jezero crater, Mars, on 18 February 2021, with a payload of scientific instruments to examine Mars' past habitability, look for signs of past life, and process samples for future return to Earth. The instrument payload includes the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) deep ultraviolet Raman and fluorescence imaging spectrometer designed to detect, characterize, and map the presence of organics and minerals on the Martian surface. Operation and engineering constraints sometimes result in the acquisition of spectra with features near the detection limit. It is therefore important to separate instrumental (background) spectral components and spectral components inherent to Martian surface materials. For SHERLOC, the instrumental background is assessed by collecting spectra in the stowed-arm configuration where the instrument is pointed at the Martian nighttime sky with no surface sample present in its optical path. These measurements reveal weak Raman and fluorescence background spectral signatures as well as charged-coupled device pixels prone to erroneous intensity spikes separate from cosmic rays. We quantitatively describe these features and provide a subtraction procedure to remove the spectral background from surface spectra. By identifying and accounting for the SHERLOC Raman background features within the median Raman spectra of Martian target scans, we find that the undefined silicate spectral feature interpreted to be either amorphous silicate or plagioclase feldspar is ubiquitously found in every Mars target Raman scan collected through Sol 751.

4.
Appl Spectrosc ; : 37028231210885, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37964538

RESUMO

In this work, we derive a simple method for calibrating Raman bandwidths for the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument onboard NASA's Perseverance rover. Raman bandwidths and shapes reported by an instrument contain contributions from both the intrinsic Raman band (IRB) and instrumental artifacts. To directly correlate bandwidth to sample properties and to compare bandwidths across instruments, the IRB width needs to be separated from instrumental effects. Here, we use the ubiquitous bandwidth calibration method of modeling the observed Raman bands as a convolution of a Lorentzian IRB and a Gaussian instrument slit function. Using calibration target data, we calculate that SHERLOC has a slit function width of 34.1 cm-1. With a measure of the instrument slit function, we can deconvolve the IRB from the observed band, providing the width of the Raman band unobscured by instrumental artifact. We present the correlation between observed Raman bandwidth and intrinsic Raman bandwidth in table form for the quick estimation of SHERLOC Raman intrinsic bandwidths. We discuss the limitations of using this model to calibrate Raman bandwidth and derive a quantitative method for calculating the errors associated with the calibration. We demonstrate the utility of this method of bandwidth calibration by examining the intrinsic bandwidths of SHERLOC sulfate spectra and by modeling the SHERLOC spectrum of olivine.

5.
J Raman Spectrosc ; 52(6): 1155-1166, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34163097

RESUMO

Carbonate rocks record the oldest forms of life on Earth, and their geologic reconstruction requires multiple methods to determine physical and chemical processes before conclusions of ancient biosignatures are made. Since crystal orientation within rock fabric may be used to infer geologic settings, we present here a complementary Raman method to study the orientation of calcite (CaCO3) and dolomite [CaMg (CO3)2] minerals. The relative peak intensity ratio of the carbonate lattice Eg modes T and L reveals the crystallographic orientation of calcite and dolomite with respect to the incident light polarization. Our results for calcite show that when the incident laser light propagates down the crystallographic a/b axis: (1) the L mode is always greater in intensity than the T mode (I T < I L), and (2) the spectra are most intense at 45° and least intense at 90° polarization angles measured from around the c axis. Our results for dolomite show that (1) I T > I L when the incident light propagation is down the crystallographic c axis and (2) I T < I L when the incident light propagation is down the crystallographic a/b axis. This study reveals mineral orientation variation related to deposition and paragenesis within limestone and dolostone samples. The method presented yields information related to growth and deformation during diagenetic and metamorphic alteration and may be used in research seeking to identify the fabric parameters of any calcite or dolomite containing rock. The compositional and structural data obtained from Raman mapping is useful in structural geology, materials science, and biosignature research.

6.
Appl Spectrosc ; 75(7): 763-773, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33876994

RESUMO

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA's Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (∼200 cm-1 to 12 000 cm-1) (with a spectral resolution of 0.296 nm (∼40 cm-1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

7.
J Nanosci Nanotechnol ; 2(3-4): 293-312, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12908255

RESUMO

Recent progress in the synthesis, characterization, and biological compatibility of nanostructured ceramics for biomedical implants is reviewed. A major goal is to develop ceramic coating technology that can reduce the friction and wear in mating total joint replacement components, thus contributing to their significantly improved function and longer life span. Particular attention is focused on the enhancement of mechanical properties such as hardness, toughness, and friction coefficient and on the bioactivity as they pertain to the nanostructure of the material. The development of three nanostructured implant coatings is discussed: diamond, hydroxyapatite, and functionally graded metalloceramics based on the Cr-Ti-N ternary system. Nanostructured diamond produced by chemical vapor deposition (CVD) techniques and composed of nano-size diamond grains have particular promise because of the combination of ultrahigh hardness, improved toughness over conventional microcrystalline diamond, low friction, and good adhesion to titanium alloys. Nanostructured processing applied to hydroxyapatite coatings is used to achieve the desired mechanical characteristics and enhanced surface reactivity and has been found to increase osteoblast adhesion, proliferation, and mineralization. Finally, nanostructured metalloceramic coatings provide continuous variation from a nanocrystalline metallic bond at the interface to the hard ceramic bond on the surface and have the ability to overcome adhesion problems associated with ceramic hard coatings on metallic substrates.


Assuntos
Cerâmica/química , Materiais Revestidos Biocompatíveis/química , Implantes Dentários , Prótese Articular , Nanotecnologia/instrumentação , Animais , Cerâmica/síntese química , Materiais Revestidos Biocompatíveis/síntese química , Corrosão , Cristalização/métodos , Diamante/química , Durapatita/síntese química , Durapatita/química , Análise de Falha de Equipamento/métodos , Dureza , Humanos , Teste de Materiais , Metais/química , Nanotecnologia/métodos , Tamanho da Partícula , Próteses e Implantes , Desenho de Prótese , Falha de Prótese
8.
Science ; 338(6114): 1583-7, 2012 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-23258889

RESUMO

Doppler weather radar imaging enabled the rapid recovery of the Sutter's Mill meteorite after a rare 4-kiloton of TNT-equivalent asteroid impact over the foothills of the Sierra Nevada in northern California. The recovered meteorites survived a record high-speed entry of 28.6 kilometers per second from an orbit close to that of Jupiter-family comets (Tisserand's parameter = 2.8 ± 0.3). Sutter's Mill is a regolith breccia composed of CM (Mighei)-type carbonaceous chondrite and highly reduced xenolithic materials. It exhibits considerable diversity of mineralogy, petrography, and isotope and organic chemistry, resulting from a complex formation history of the parent body surface. That diversity is quickly masked by alteration once in the terrestrial environment but will need to be considered when samples returned by missions to C-class asteroids are interpreted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA