Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 310(1): e231405, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38193842

RESUMO

Background Deep learning (DL)-based MRI reconstructions can reduce imaging times for turbo spin-echo (TSE) examinations. However, studies that prospectively use DL-based reconstructions of rapidly acquired, undersampled MRI in the shoulder are lacking. Purpose To compare the acquisition time, image quality, and diagnostic confidence of DL-reconstructed TSE (TSEDL) with standard TSE in patients indicated for shoulder MRI. Materials and Methods This prospective single-center study included consecutive adult patients with various shoulder abnormalities who were clinically referred for shoulder MRI between February and March 2023. Each participant underwent standard TSE MRI (proton density- and T1-weighted imaging; conventional TSE sequence was used as reference for comparison), followed by a prospectively undersampled accelerated TSEDL examination. Six musculoskeletal radiologists evaluated images using a four-point Likert scale (1, poor; 4, excellent) for overall image quality, perceived signal-to-noise ratio, sharpness, artifacts, and diagnostic confidence. The frequency of major pathologic features and acquisition times were also compared between the acquisition protocols. The intergroup comparisons were performed using the Wilcoxon signed rank test. Results Overall, 135 shoulders in 133 participants were evaluated (mean age, 47.9 years ± 17.1 [SD]; 73 female participants). The median acquisition time of the TSEDL protocol was lower than that of the standard TSE protocol (288 seconds [IQR, 288-288 seconds] vs 926 seconds [IQR, 926-950 seconds], respectively; P < .001), achieving a 69% lower acquisition time. TSEDL images were given higher scores for overall image quality, perceived signal-to-noise ratio, and artifacts (all P < .001). Similar frequency of pathologic features (P = .48 to > .99), sharpness (P = .06), or diagnostic confidence (P = .05) were noted between images from the two protocols. Conclusion In a clinical setting, TSEDL led to reduced examination time and higher image quality with similar diagnostic confidence compared with standard TSE MRI in the shoulder. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Chang and Chow in this issue.


Assuntos
Aprendizado Profundo , Ombro , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Ombro/diagnóstico por imagem , Imageamento por Ressonância Magnética , Artefatos , Exame Físico
2.
NMR Biomed ; 37(2): e5049, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37767723

RESUMO

Magnetic resonance imaging (MRI)/magnetic resonance spectroscopy (MRS) employing proton nuclear resonance has emerged as a pivotal modality in clinical diagnostics and fundamental research. Nonetheless, the scope of MRI/MRS extends beyond protons, encompassing nonproton nuclei that offer enhanced metabolic insights. A notable example is phosphorus-31 (31 P) MRS, which provides valuable information on energy metabolites within the skeletal muscle and cardiac tissues of individuals affected by diabetes. This study introduces a novel double-tuned coil tailored for 1 H and 31 P frequencies, specifically designed for investigating cardiac metabolism in rabbits. The proposed coil design incorporates a butterfly-like coil for 31 P transmission, a four-channel array for 31 P reception, and an eight-channel array for 1 H reception, all strategically arranged on a body-conformal elliptic cylinder. To assess the performance of the double-tuned coil, a comprehensive evaluation encompassing simulations and experimental investigations was conducted. The simulation results demonstrated that the proposed 31 P transmit design achieved acceptable homogeneity and exhibited comparable transmit efficiency on par with a band-pass birdcage coil. In vivo experiments further substantiated the coil's efficacy, revealing that the rabbit with experimentally induced diabetes exhibited a lower phosphocreatine/adenosine triphosphate ratio compared with its normal counterpart. These findings emphasize the potential of the proposed coil design as a promising tool for investigating the therapeutic effects of novel diabetes drugs within the context of animal experimentation. Its capability to provide detailed metabolic information establishes it as an indispensable asset within this realm of research.


Assuntos
Diabetes Mellitus , Imageamento por Ressonância Magnética , Animais , Coelhos , Imageamento por Ressonância Magnética/métodos , Prótons , Desenho de Equipamento , Espectroscopia de Ressonância Magnética/métodos , Imagens de Fantasmas
3.
Chemistry ; 30(1): e202302624, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37806959

RESUMO

A pair of isomers, IDT-BOF containing S⋅⋅⋅O/F⋅⋅⋅H noncovalently configurational locks and IDT-BFO containing F⋅⋅⋅H/O⋅⋅⋅H noncovalently configurational locks, with an acceptor-π-donor-π-acceptor (A-π-D-π-A) structure have been designed and synthesized by choosing 4,9-dihydro-s-indaceno[1,2-b : 5,6-b']dithiophene (IDT) as the D unit, an F/n-hexyloxy substituted phenyl ring as π bridge, and 3-(dicyanomethylidene)indan-1-one as the A unit. Owing to the S⋅⋅⋅O/F⋅⋅⋅H or F⋅⋅⋅H/O⋅⋅⋅H noncovalently configurational locks, both IDT-BOF and IDT-BFO have a completely planar structure. IDT-BOF exhibits a similar LUMO to IDT-BFO, but higher HOMO energy levels, leading to a smaller optical bandgap and red-shifted absorption. However, IDT-BOF-based bulk-heterojunction organic solar cells (BHJ-OSCs) coupled with PBDB-T, and PCE-10 as donor materials both exhibited a lower PCE than that of IDT-BFO (PBDB-T: 5.2 vs. 6.1 %; PCE-10: 1.7 vs. 3.2 %). Comprehensively comparing and investigating IDT-BOF : PBDB-T and IDT-BFO : PBDB-T OSCs suggested that the large phase separation and serious charge recombination of IDT-BOF-based OSCs contributed to its lower power conversion efficiency. Importantly, ternary solar cells based on PBDB-T : Y5 as control devices with an additional 10 % IDT-BFO exhibited a 5 % enhancement in the PCE compared to the control device (14.3 vs. 13.46 %).

4.
J Magn Reson Imaging ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38376448

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI)-based virtual MR elastography (DWI-vMRE) in the assessment of breast lesions is still in the research stage. PURPOSE: To investigate the usefulness of elasticity values on DWI-vMRE in the evaluation of breast lesions, and the correlation with the values calculated from shear-wave elastography (SWE). STUDY TYPE: Prospective. POPULATION/SUBJECTS: 153 patients (mean age ± standard deviation: 55 ± 12 years) with 153 pathological confirmed breast lesions (24 benign and 129 malignant lesions). FIELD STRENGTH/SEQUENCE: 1.5-T MRI, multi-b readout segmented echo planar imaging (b-values of 0, 200, 800, and 1000 sec/mm2 ). ASSESSMENT: For DWI-vMRE assessment, lesions were manually segmented using apparent diffusion coefficient (ADC0-1000 ) map, then the region of interests were copied to the map of shifted-ADC (sADC200-800 , sADC 200-1500 ). For SWE assessment, the shear modulus of the lesions was measured by US elastic modulus (µUSE ). Intraclass/interclass kappa coefficients were calculated to measure the consistency. STATISTICAL TESTS: Pearson's correlation was used to assess the relationship between sADC and µUSE . A receiver operating characteristic analysis with the area under the curve (AUC) was performed to compare the diagnostic accuracy between benign and malignant breast lesions of sADC and µUSE . A P value <0.05 was considered statistically significant. RESULTS: There were significant differences between benign and malignant breast lesions of µUSE (24.17 ± 10.64 vs. 37.20 ± 12.61), sADC200-800 (1.38 ± 0.31 vs. 0.97 ± 0.18 × 10-3 mm2 /sec), and sADC200-1500 (1.14 ± 0.30 vs. 0.78 ± 0.13 × 10-3 mm2 /sec). In all breast lesions, a moderate but significant correlation was observed between µUSE and sADC200-800 /sADC200-1500 (r = -0.49/-0.44). AUC values to differentiate benign from malignant lesions were as follows: µUSE , 0.78; sADC200-800 , 0.89; sADC200-1500 , 0.89. DATA CONCLUSIONS: Both SWE and DWI-vMRE could be used for the differentiation of benign versus malignant breast lesions. Furthermore, DWI-vMRE with the use of sADC show relatively higher AUC values than SWE. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.

5.
J Magn Reson Imaging ; 59(3): 954-963, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37312270

RESUMO

BACKGROUND: Gamma-aminobutyric acid (GABA) is an inhibitory neurotransmitter in human brains, playing a role in the pathogenesis of various psychiatric disorders. Current methods have some non-neglectable shortcomings and noninvasive and accurate detection of GABA in human brains is long-term challenge. PURPOSE: To develop a pulse sequence capable of selectively detecting and quantifying the 1 H signal of GABA in human brains based on optimal controlled spin singlet order. STUDY TYPE: Prospective. SUBJECTS/PHANTOM: A phantom of GABA (pH = 7.3 ± 0.1) and 11 healthy subjects (5 females and 6 males, body mass index: 21 ± 3 kg/m2 , age: 25 ± 4 years). FIELD STRENGTH/SEQUENCE: 7 Tesla, 3 Tesla, GABA-targeted magnetic resonance spectroscopy (GABA-MRS-7 T, GABA-MRS-3 T), magnetization prepared two rapid acquisition gradient echoes sequence. ASSESSMENT: By using the developed pulse sequences applied on the phantom and healthy subjects, the signals of GABA were successfully selectively probed. Quantification of the signals yields the concentration of GABA in the dorsal anterior cingulate cortex (dACC) in human brains. STATISTICAL TESTS: Frequency. RESULTS: The 1 H signals of GABA in the phantom and in the human brains of healthy subjects were successfully detected. The concentration of GABA in the dACC of human brains was 3.3 ± 1.5 mM. DATA CONCLUSION: The developed pulse sequences can be used to selectively probe the 1 H MR signals of GABA in human brains in vivo. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Estudos Prospectivos , Espectroscopia de Ressonância Magnética/métodos , Ácido gama-Aminobutírico
6.
J Magn Reson Imaging ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38826142

RESUMO

BACKGROUND: The number of focal liver lesions (FLLs) detected by imaging has increased worldwide, highlighting the need to develop a robust, objective system for automatically detecting FLLs. PURPOSE: To assess the performance of the deep learning-based artificial intelligence (AI) software in identifying and measuring lesions on contrast-enhanced magnetic resonance imaging (MRI) images in patients with FLLs. STUDY TYPE: Retrospective. SUBJECTS: 395 patients with 1149 FLLs. FIELD STRENGTH/SEQUENCE: The 1.5 T and 3 T scanners, including T1-, T2-, diffusion-weighted imaging, in/out-phase imaging, and dynamic contrast-enhanced imaging. ASSESSMENT: The diagnostic performance of AI, radiologist, and their combination was compared. Using 20 mm as the cut-off value, the lesions were divided into two groups, and then divided into four subgroups: <10, 10-20, 20-40, and ≥40 mm, to evaluate the sensitivity of radiologists and AI in the detection of lesions of different sizes. We compared the pathologic sizes of 122 surgically resected lesions with measurements obtained using AI and those made by radiologists. STATISTICAL TESTS: McNemar test, Bland-Altman analyses, Friedman test, Pearson's chi-squared test, Fisher's exact test, Dice coefficient, and intraclass correlation coefficients. A P-value <0.05 was considered statistically significant. RESULTS: The average Dice coefficient of AI in segmentation of liver lesions was 0.62. The combination of AI and radiologist outperformed the radiologist alone, with a significantly higher detection rate (0.894 vs. 0.825) and sensitivity (0.883 vs. 0.806). The AI showed significantly sensitivity than radiologists in detecting all lesions <20 mm (0.848 vs. 0.788). Both AI and radiologists achieved excellent detection performance for lesions ≥20 mm (0.867 vs. 0.881, P = 0.671). A remarkable agreement existed in the average tumor sizes among the three measurements (P = 0.174). DATA CONCLUSION: AI software based on deep learning exhibited practical value in automatically identifying and measuring liver lesions. TECHNICAL EFFICACY: Stage 2.

7.
J Magn Reson Imaging ; 59(1): 297-308, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37165908

RESUMO

BACKGROUND: Computed diffusion-weighted images (cDWI) of random b value could be derived from acquired DWI (aDWI) with at least two different b values. However, its comparison between aDWI and cDWI images in locally advanced rectal cancer (LARC) patients after neoadjuvant therapy (NT) is needed. PURPOSE: To compare the cDWI and aDWI in image quality, restaging, and treatment response of LARC after NT. STUDY TYPE: Retrospective. POPULATION: Eighty-seven consecutive patients. FIELD STRENGTH/SEQUENCE: 3.0 T/DWI. ASSESSMENT: All patients underwent two DWI sequences, including conventional acquisition with b = 0 and 1000 s/mm2 (aDWIb1000 ) and another with b = 0 and 700 s/mm2 on a 3.0-T MR scanner. The images of the latter were used to compute the diffusion images with b = 1000 s/mm2 (cDWIb1000 ). Four radiologists with 3, 4, 14, and 25 years of experience evaluated the images to compare the image quality, TN restaging performance, and treatment response between aDWIb1000 and cDWIb1000 . STATISTICAL TESTS: Interclass correlation coefficients, weighted κ coefficient, paired Wilcoxon, and McNemar or Fisher test were used. A significance level of 0.05 was used. RESULTS: The cDWIb1000 images were superior to the aDWIb1000 ones in both subjective and objective image quality. In T restaging, the overall diagnostic accuracy of cDWIb1000 images was higher than that of aDWIb1000 images (57.47% vs. 49.43%, P = 0.289 for the inexperienced radiologist; 77.01% vs. 63.22%, significant for the experienced radiologist), with better sensitivity in determining ypT0-Tis tumors. Additionally, it increased the sensitivity in detecting ypT2 tumors for the inexperienced radiologist and ypT3 tumors for the experienced radiologist. N restaging and treatment response were found to be similar between two sequences for both radiologists. DATA CONCLUSION: Compared to aDWIb1000 images, the computed ones might serve as a wise approach, providing comparable or better image quality, restaging performance, and treatment response assessment for LARC after NT. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Humanos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Reto/patologia
8.
Angew Chem Int Ed Engl ; 63(4): e202312534, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-37968890

RESUMO

Currently, purely organic compounds showing ambient phosphorescence with high efficiency (ΦP ) and ultra-long lifetime (τP ) are quite rare and often need to be achieved in hydrophilic poly(vinyl alcohol)-based hosts. This severely limits their applications. Here, we provide a solution to this issue by constructing an ortho-linked donor-acceptor (D-A) dyad whose D moiety has not only a long-lived T1 state to achieve a long τP , but also a Tn state that is close to the S1 state of the dyad to trigger effective spin-orbit charge transfer intersystem crossing (SOCT-ISC). The rationality of this strategy was validated by a new phosphor OF-BCz that is able to show a τP of 1.92 s and a ΦP of 30 % even in a less rigid matrix of poly(methyl methacrylate) (PMMA). Excitingly, OF-BCz exhibited its potential as both a photocuring initiator and an in situ quality indicator, allowing for the visual detection of defects in photolithographic patterning.

9.
Angew Chem Int Ed Engl ; 63(1): e202314447, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37968894

RESUMO

Although long-lived triplet charge-transfer (3 CT) state with high energy level has gained significant attention, the development of organic small molecules capable of achieving such states remains a major challenge. Herein, by using the through-space electronic coupling effect, we have developed a compound, namely NIC-DMAC, which has a long-lived 3 CT state at the single-molecule level with a lifetime of 210 ms and a high energy level of up to 2.50 eV. Through a combination of experimental and computational approaches, we have elucidated the photophysical processes of NIC-DMAC, which involve sequential transitions from the first singlet excited state (S1 ) that shows a 1 CT character to the first triplet excited state (T1 ) that exhibits a local excited state feature (3 LE), and then to the second triplet excited state (T2 ) that shows a 3 CT character (i.e., S1 (1 CT)→T1 (3 LE)→T2 (3 CT)). The long lifetime and high energy level of its 3 CT state have enabled NIC-DMAC as an initiator for photocuring in double patterning applications.

10.
Magn Reson Med ; 90(2): 722-736, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37052377

RESUMO

PURPOSE: To propose a novel Numerical fitting method of the Extrapolated semisolid Magnetization transfer Reference (NEMR) signal for quantifying the CEST effect. THEORY AND METHODS: Modified two-pool Bloch-McConnell equations were used to numerically fit the magnetization transfer (MT) and direct water saturation (DS) signals at far off-resonance frequencies, which was subsequently extrapolated into the frequency range of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) pools. Then the subtraction of the fitted two-pool z-spectrum and the experimentally acquired z-spectrum yielded APT# and NOE# signals mostly free of MT and DS contamination. Several strategies were used to accelerate the NEMR fitting. Furthermore, the proposed NEMR method was compared with the conventional extrapolated semisolid magnetization transfer reference (EMR) and magnetization transfer ratio asymmetry (MTRasym ) methods in simulations and stroke patients. RESULTS: The combination of RF downsampling, MT lineshape look-up table, and conversion of MATLAB code to C code accelerated the NEMR fitting by over 2700-fold. Monte-Carlo simulations showed that NEMR had higher accuracy than EMR and eliminated the requirement of the steady-state condition. In ischemic stroke patients, the NEMR maps at 1 µT removed hypointense artifacts seen on EMR and MTRasym images, and better depicted stroke lesions than EMR. For NEMR, NOE# yielded significantly (p < 0.05) stronger signal contrast between stroke and normal tissues than APT# at 1 µT. CONCLUSION: The proposed NEMR method is suitable for arbitrary saturation settings and can remove MT and DS contamination from the CEST signal for improved detection of ischemic stroke.


Assuntos
Neoplasias Encefálicas , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética/métodos , Algoritmos , Acidente Vascular Cerebral/diagnóstico por imagem , Prótons , Amidas
11.
Magn Reson Med ; 89(5): 1728-1740, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36572961

RESUMO

PURPOSE: The signals of glutamate (Glu) and glutamine (Gln) are often significantly overlapped in routine 1 H-MR spectra of human brain in vivo. Selectively probing the signals of Glu and Gln in vivo is very important for the study of the metabolisms in which Glu and Gln are involved. METHODS: The Glu-/Gln- targeted pulse sequences are developed to selectively probe the signals of Glu and Gln. The core part of the Glu-/Gln- targeted pulse sequences lies on the preparation of the nuclear spin singlet orders (SSOs) of the five-spin systems of Glu and Gln. The optimal control method is used to prepare the SSOs of Glu and Gln with high efficiency. RESULTS: The Glu-/Gln- targeted pulse sequences have been applied on phantoms to selectively probe the signals of Glu and Gln. Moreover, in the in vivo experiments, the signals of Glu and Gln in human brains of healthy subjects have been successfully probed separately. CONCLUSION: The developed Glu-/Gln- targeted pulse sequences can be used to distinguish the 1 H-MR signals of Glu and Gln in human brains in vivo. The optimal control method provides an effective way to prepare the SSO of a specific spin system with high efficiency and in turn selectively probe the signals of a targeted molecule.


Assuntos
Ácido Glutâmico , Glutamina , Humanos , Glutamina/metabolismo , Ácido Glutâmico/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Imagens de Fantasmas
12.
NMR Biomed ; 36(6): e4689, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34994025

RESUMO

Chemical exchange saturation transfer (CEST) imaging benefits from a longer saturation duration and a higher saturation duty cycle. Dielectric shading effects occur when the radiofrequency (RF) wavelength approaches the object size. Here, we proposed a simultaneous parallel transmission-based CEST (pTx-CEST) sequence to prolongate the saturation duration at a 100% duty cycle and improve the RF saturation homogeneity in CEST imaging. The simultaneous pTx-CEST sequence was implemented by switching the CEST saturation module from the non-pTx to pTx mode, using the pTx functionality with both transmit channels being driven simultaneously (instead of time-interleaved). The optimization of amplitude ratio and phase difference settings between RF channels for best B1 homogeneity was performed in phantoms of two different sizes mimicking the human brain and abdomen. The optimal amplitude and phase settings generating the best B1 homogeneity in the phantoms were used in pTx-CEST scans of the human study. The comparison of the maximum achievable saturation duration between the non-pTx-CEST and pTx-CEST sequences was performed in a protein phantom, healthy volunteers, and a metastatic brain tumor patient. The optimal amplitude ratio and phase difference setting between transmit channels manifested circular and elliptical polarization in the head-sized and abdomen-sized phantoms. In the brain, the maximum saturation durations achieved at a 100% duty cycle using the simultaneous pTx-CEST sequence were prolonged to 2240, 3220, and 4200 ms compared with 980 ms using the non-pTx-CEST sequence at repetition times of 3, 4, and 5 s, respectively. The longer saturation duration helped improve the image contrast between the tumor and the normal tissue in the patient. The optimized elliptical polarization mode saturation pulses yielded improved uniformity of CEST signals acquired from the human abdomen. The proposed simultaneous pTx-CEST sequence enabled essentially arbitrarily long saturation duration at a 100% duty cycle and helped reduce the dielectric shading effects with the optimized RF setting.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Aumento da Imagem/métodos , Concentração de Íons de Hidrogênio , Imagens de Fantasmas , Algoritmos
13.
J Magn Reson Imaging ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37994206

RESUMO

BACKGROUND: The uterus undergoes dynamic changes throughout the menstrual cycle. Diffusion kurtosis imaging (DKI) is based on the non-Gaussian distribution of water molecules and can perhaps represent the changes of uterine microstructure. PURPOSE: To investigate the temporal changes in DKI-parameters of the normal uterine corpus and cervix during the menstrual cycle. STUDY TYPE: Prospective. POPULATION: 21 healthy female volunteers (26.64 ± 4.72 years) with regular menstrual cycles (28 ± 7 days). FIELD STRENGTH/SEQUENCE: Readout segmentation of long variable echo-trains (RESOLVE)-based DKI and fast spin-echo T2-weighted sequences at 3.0T. ASSESSMENT: Each volunteer was scanned during the menstrual phase, ovulatory phase, and luteal phase. Regions of interest (ROI) were manually delineated in the endometrium, junctional zone, and myometrium of the uterine body, and in the mucosal layer, fibrous stroma layer, and loose stroma layer of the cervix. The mean Kapp (diffusion kurtosis coefficient), Dapp (diffusion coefficient), and ADC (apparent diffusion coefficient) values were measured in the ROI. STATISTICAL TESTS: ANOVA with Bonferroni or Tamhane correction. Intraclass correlation coefficient (ICC) for assessing agreement. P < 0.05 was considered statistically significant. RESULTS: During the menstrual cycle, the highest Kapp (0.848 ± 0.184) and lowest Dapp (1.263 ± 0.283 *10-3 mm2 /sec) values were found in the endometrium during the menstrual phase. The Dapp values for the myometrium were significantly higher than those of the endometrium and the junctional zone in every phase. Meanwhile, the Dapp values for the three zonal structures of the cervix during ovulation were significantly higher than those during the luteal phase. However, there was no significant difference in the ADC values of the loose stroma between ovulation and the luteal phase (P = 0.568). The reproducibility of DKI parameters was good (ICC, 0.857-0.944). DATA CONCLUSION: DKI can show dynamic changes of the normal uterus during the menstrual cycle. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

14.
J Magn Reson Imaging ; 58(1): 81-92, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36433714

RESUMO

BACKGROUND: CAIPIRINHA-Dixon-TWIST-VIBE (CDTV) dynamic contrast-enhanced MRI (DCE-MRI) can be used to characterize breast cancer. However, the influence of the clinicopathologic factors and molecular subtypes of invasive breast carcinoma (IDC) on the model-free and model-based parameters has not been investigated. PURPOSE: To compare model-free and model-based parameters of CDTV DCE-MRI with both clinicopathologic factors and molecular subtypes of IDC. STUDY TYPE: Prospective. POPULATION: A total of 152 patients (mean age, 52 years) with IDC including 42 luminal A, 64 luminal B, 22 human epidermal growth factor receptor-2 (HER2) positive, and 24 triple-negative subtypes. FIELD STRENGTH/SEQUENCE: A 3 T; turbo-FLASH, Dixon VIBE, and CDTV. ASSESSMENT: Model-free parameters (initial enhancement rate [IER] and maximum slope [MS]) were estimated from the time-intensity curve. The mean, minimum, maximum, and range between the minimum and maximum values of inline model-based parameters (Ktrans , kep , and ve ) were measured to assess intratumoral heterogeneity of IDC lesions. STATISTICAL TESTS: Student's t tests, Mann-Whitney U tests, Kruskal-Wallis tests, post hoc Steel-Dwass tests, and receiver operating characteristic (ROC) curves. P < 0.05 was considered significant. RESULTS: No significant differences in IER and MS values were seen among the clinicopathologic factors and molecular subtypes (Bonferroni-corrected P = 0.011-0.862, P = 0.145-0.601, respectively). The minimum kep values in HER2-positive IDC were significantly lower than those in HER2-negative IDC. The mean and range kep values were independent predictors for distinguishing the high (grade 3) and low (grade 1 or 2) nuclear grade groups according to multivariable analyses. The post hoc test showed that the kep minimum and kep range values were significantly different between luminal A and HER2-positive tumor subtypes, yielding an area-under-the-curve of 0.820. DATA CONCLUSION: Compared with the model-free parameters, inline kep related model-based parameters on CDTV DCE-MRI can be applied as a feasible tool to differentiate luminal A from HER2-positive breast cancers. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias da Mama , Humanos , Pessoa de Meia-Idade , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Prognóstico , Estudos Prospectivos , Meios de Contraste , Imageamento por Ressonância Magnética , Estudos Retrospectivos
15.
Eur Radiol ; 33(5): 3286-3294, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36512040

RESUMO

OBJECTIVES: To prospectively investigate the capability of arterial spin labeling (ASL) and intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) for the identification of early kidney injury in chronic kidney disease (CKD) patients with normal estimated glomerular filtration rate (eGFR). METHODS: Fifty-four CKD patients confirmed by renal biopsy (normal eGFR group [eGFR ≥ 90 mL/min/1.73 m2]: n = 26; abnormal eGFR group [eGFR < 90 mL/min/1.73 m2]: n = 28) and 20 healthy volunteers (HV) were recruited. All subjects were examined by IVIM-DWI and ASL imaging. Renal blood flow (RBF) derived from ASL, true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) derived from IVIM-DWI were measured from the renal cortex. One-way analysis of variance was used to compare MRI parameters among the three groups. The correlation between eGFR and MRI parameters was evaluated by Spearman correlation analysis. Diagnostic performances of MRI parameters for detecting kidney injury were assessed by receiver operating characteristic (ROC) curves. RESULTS: The renal cortical D, D*, f, and RBF values showed statistically significant differences among the three groups. eGFR was positively correlated with MRI parameters (D: r = 0.299, D*: r = 0.569, f: r = 0.733, RBF: r = 0.586). The areas under the curve (AUCs) for discriminating CKD patients from HV were 0.725, 0.752, 0.947, and 0.884 by D, D*, f, and RBF, respectively. D, D*, f, RBF, and eGFR identified CKD patients with normal eGFR with AUCs of 0.735, 0.612, 0.917, 0.827, and 0.733, respectively, and AUC of f value was significantly larger than that of eGFR. CONCLUSION: IVIM-DWI and ASL were useful for detecting underlying pathologic injury in early CKD patients with normal eGFR. KEY POINTS: • The renal cortical f and RBF values in the control group were significantly higher than those in the normal eGFR group. • A negative correlation was observed between the renal cortical D, D*, f, and RBF values and SCr and 24 h-UPRO, while eGFR was significantly positively correlated with renal cortical D, D*, f, and RBF values. • The AUC of renal cortical f values was statistically larger than that of eGFR for the discrimination between the CKD with normal eGFR group and the control group.


Assuntos
Rim , Insuficiência Renal Crônica , Humanos , Marcadores de Spin , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Movimento (Física)
16.
Eur Radiol ; 33(6): 4138-4147, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36502460

RESUMO

OBJECTIVES: To investigate the diagnostic value of functional MRI to assess renal interstitial fibrosis in patients with chronic kidney disease (CKD). METHODS: We prospectively recruited 80 CKD patients who underwent renal biopsies and 16 healthy volunteers to undergo multiparametric functional MRI examinations. The Oxford MEST-C classification was used to score the interstitial fibrosis. The diagnostic performance of functional MRI to discriminate interstitial fibrosis was evaluated by calculating the area under the receiver operating characteristic (ROC) curves. RESULTS: IgA nephropathy (60%) accounted for the majority of pathologic type in the CKD patients. Apparent diffusion coefficient (ADC) from diffusion-weighted imaging (DWI) was correlated with interstitial fibrosis (rho = -0.73). Decreased renal blood flow (RBF) derived from arterial spin labeling (rho = -0.78) and decreased perfusion fraction (f) derived from DWI (rho = -0.70) were accompanied by increased interstitial fibrosis. The T1 value from T1 mapping correlated with interstitial fibrosis (rho = 0.67) (all p < 0.01). The areas under the ROC curve for the discrimination of ≤ 25% vs. > 25% and ≤ 50% vs. > 50% interstitial fibrosis were 0.87 (95% confidence interval, 0.78 to 0.94) and 0.93 (0.86 to 0.98) by ADC, 0.84 (0.74 to 0.91) and 0.94 (0.86 to 0.98) by f, 0.93 (0.85 to 0.98) and 0.90 (0.82 to 0.96) by RBF, and 0.91 (0.83 to 0.96) and 0.77 (0.66 to 0.85) by T1, respectively. CONCLUSIONS: Functional MRI parameters were strongly correlated with the interstitial fibrosis of CKD. Therefore, it might a powerful tool to assess interstitial fibrosis of CKD noninvasively. KEY POINTS: • In CKD patients, the renal cortical ADC value decreased and T1 value increased significantly compared with healthy volunteers. • Functional MRI revealed significantly decreased renal perfusion in CKD patients compared with healthy volunteers. • The renal cortical ADC, f, RBF, and T1 values were strongly correlated with the interstitial fibrosis of CKD.


Assuntos
Insuficiência Renal Crônica , Humanos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/patologia , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Fibrose
17.
Eur Radiol ; 33(6): 4115-4126, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36472695

RESUMO

OBJECTIVES: Carotid artery stenting (CAS) is an established treatment for local stenosis. The most common complication is new ipsilateral ischemic lesions (NIILs). This study aimed to develop models considering lesion morphological and compositional features, and radiomics to predict NIILs. MATERIALS AND METHODS: One hundred and forty-six patients who underwent brain MRI and high-resolution vessel wall MR imaging (hrVWI) before and after CAS were retrospectively recruited. Lumen and outer wall boundaries were segmented on hrVWI as well as atherosclerotic components. A traditional model was constructed with patient clinical information, and lesion morphological and compositional features. Least absolute shrinkage and selection operator algorithm was performed to determine key radiomics features for reconstructing a radiomics model. The model in predicting NIILs was trained and its performance was tested. RESULTS: Sixty-one patients were NIIL-positive and eighty-five negative. Volume percentage of intraplaque hemorrhage (IPH) and patients' clinical presentation (symptomatic/asymptomatic) were risk factors of NIILs. The traditional model considering these two features achieved an area under the curve (AUC) of 0.778 and 0.777 in the training and test cohorts, respectively. Twenty-two key radiomics features were identified and the model based on these features achieved an AUC of 0.885 and 0.801 in the two cohorts. The AUCs of the combined model considering IPH volume percentage, clinical presentation, and radiomics features were 0.893 and 0.842 in the training and test cohort respectively. CONCLUSIONS: Compared with traditional features (clinical and compositional features), the combination of traditional and radiomics features improved the power in predicting NIILs after CAS. KEY POINTS: • Volume percentage of IPH and symptomatic events were independent risk factors of new ipsilateral ischemic lesions (NIILs). • Radiomics features derived from carotid artery high-resolution vessel wall imaging had great potential in predicting NIILs after CAS. • The combination model with radiomics and traditional features further improved the diagnostic performance than traditional features alone.


Assuntos
Estenose das Carótidas , Humanos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Estenose das Carótidas/complicações , Estudos Retrospectivos , Stents/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Artérias Carótidas/patologia , Hemorragia/etiologia
18.
Eur Radiol ; 33(2): 1353-1363, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35997838

RESUMO

OBJECTIVE: To investigate the feasibility of b-value threshold (bThreshold) map in preoperative evaluation of tumor budding (TB) in patients with locally advanced rectal cancer (LARC). METHODS: Patients with LARC were enrolled and underwent diffusion-weighted imaging (DWI). Contrast-to-noise ratio (CNR) between the lesions and normal tissues was assessed using DWI and bThreshold maps. TB was counted and scored using hematoxylin and eosin staining. Reproducibility for the apparent diffusion coefficient (ADC), bThreshold values, and region-of-interest (ROI) sizes were compared. Differences in ADC and bThreshold values with low-intermediate and high TB grades and the correlations between mean ADC and bThreshold values with TB categories were analyzed. Diagnostic performance of ADC and bThreshold values was assessed using area under the curve (AUC) and decision curve analysis. RESULTS: Fifty-one patients were evaluated. The CNR on bThreshold maps was significantly higher than that on DW images (9.807 ± 4.811 vs 7.779 ± 3.508, p = 0.005). Reproducibility was excellent for the ADC (ICC 0.933; CV 8.807%), bThreshold values (ICC 0.958; CV 7.399%), and ROI sizes (ICC 0.934; CV 8.425%). Significant negative correlations were observed between mean ADC values and TB grades and positive correlations were observed between mean bThreshold values and TB grades (p < 0.05). bThreshold maps showed better diagnostic performance than ADC maps (AUC, 0.914 vs 0.726; p = 0.048). CONCLUSIONS: In LARC patients, bThreshold values could distinguish different TB grades better than ADC values, and bThreshold maps may be a preoperative, non-invasive approach to evaluate TB grades. KEY POINTS: • Compared with diffusion-weighted images, bThreshold maps improved visualization and detection of rectal tumors. • Agreement and diagnostic performance of bThreshold values are superior to apparent diffusion coefficient in assessing tumor budding grades in patients with locally advanced rectal cancer. • bThreshold maps could be used to evaluate tumor budding grades non-invasively before operation.


Assuntos
Adenocarcinoma , Segunda Neoplasia Primária , Neoplasias Retais , Humanos , Reprodutibilidade dos Testes , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Reto/patologia , Adenocarcinoma/diagnóstico por imagem
19.
Eur Radiol ; 33(10): 7238-7249, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37145148

RESUMO

OBJECTIVES: We applied a fully automated pixel-wise post-processing framework to evaluate fully quantitative cardiovascular magnetic resonance myocardial perfusion imaging (CMR-MPI). In addition, we aimed to evaluate the additive value of coronary magnetic resonance angiography (CMRA) to the diagnostic performance of fully automated pixel-wise quantitative CMR-MPI for detecting hemodynamically significant coronary artery disease (CAD). METHODS: A total of 109 patients with suspected CAD were prospectively enrolled and underwent stress and rest CMR-MPI, CMRA, invasive coronary angiography (ICA), and fractional flow reserve (FFR). CMRA was acquired between stress and rest CMR-MPI acquisition, without any additional contrast agent. Finally, CMR-MPI quantification was analyzed by a fully automated pixel-wise post-processing framework. RESULTS: Of the 109 patients, 42 patients had hemodynamically significant CAD (FFR ≤ 0.80 or luminal stenosis ≥ 90% on ICA) and 67 patients had hemodynamically non-significant CAD (FFR ˃ 0.80 or luminal stenosis < 30% on ICA) were enrolled. On the per-territory analysis, patients with hemodynamically significant CAD had higher myocardial blood flow (MBF) at rest, lower MBF under stress, and lower myocardial perfusion reserve (MPR) than patients with hemodynamically non-significant CAD (p < 0.001). The area under the receiver operating characteristic curve of MPR (0.93) was significantly larger than those of stress and rest MBF, visual assessment of CMR-MPI, and CMRA (p < 0.05), but similar to that of the integration of CMR-MPI with CMRA (0.90). CONCLUSIONS: Fully automated pixel-wise quantitative CMR-MPI can accurately detect hemodynamically significant CAD, but the integration of CMRA obtained between stress and rest CMR-MPI acquisition did not provide significantly additive value. KEY POINTS: • Full quantification of stress and rest cardiovascular magnetic resonance myocardial perfusion imaging can be postprocessed fully automatically, generating pixel-wise myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) maps. • Fully quantitative MPR provided higher diagnostic performance for detecting hemodynamically significant coronary artery disease, compared with stress and rest MBF, qualitative assessment, and coronary magnetic resonance angiography (CMRA). • The integration of CMRA and MPR did not significantly improve the diagnostic performance of MPR alone.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico , Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Constrição Patológica , Valor Preditivo dos Testes , Perfusão , Imagem de Perfusão do Miocárdio/métodos
20.
Environ Res ; 237(Pt 1): 116942, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37633631

RESUMO

Harmful algal blooms pose an emerging threat to freshwater ecological security and human health, necessitating further study in offshore areas. In this work, boron-doped diamond electro-oxidation (BDD/EO) coupled with a ceramic membrane filtration was employed aiming to assess the salt tide affecting algae-laden water treatment involving with various natural organic matters (e.g., HA, SA, and BSA). The results have demonstrated that BDD/EO remove chlorophyll from the algae-laden water effectively due to the inactivation of algal cells. Moreover, considering the influence of salt tide, NH3-N would be mainly oxidized through the in-situ generated active chlorine at the electrode-liquid interface. In addition, in three kinds of salt tide affecting algae-laden water, TOC content in BSA group was decreasing remarkably after BDD/EO with TOC removal efficiency above 80%; while those in HA and SA groups had no obvious reducing due to the more algae cells breakage synchronous with HA and SA removal. Based on the fluorescent characteristics and particle size distribution, the generated small molecular organics after electro-oxidation might raise the pore blockage probability and the hydrophobic organic and fluorescent substances were preferentially oxidized in BDD/EO process being beneficial to reducing membrane fouling. Besides, the membrane special flux in three groups were decreasing significantly and the irreversible fouling resistance in SA group accounted for a larger proportion of the total resistance than those of HA and BSA. At last, in BDD/EO-CM process, macromolecular substances degradation rate was greater than that of small molecules based on the molecular weight distribution in three groups of salt tide affected algae-laden water treatment. In a word, this work provides effective and innovative strategies for the harmful algal bloom control and contributes interesting insights of membrane fouling performance of electrochemical coupled ultrafiltration membrane process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA