Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am Surg ; 71(9): 738-43, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16468509

RESUMO

Laparoscopic adjustable gastric banding (LAGB) is considered a relatively safe weight loss procedure with low morbidity. When complications occur, obstruction, erosion, and port malfunction require reoperation. We retrospectively reviewed our experience with 270 consecutive patients who underwent LAGB. Device-related reoperations were performed in 26 (10%) patients. Reoperations were related to the band in 13, to port/tubing in 11, and related to both in 2 patients. Of the 15 band-related problems, it was removed in 5 (2%): slippage (3), intra-abdominal abscess (1), and during emergent operation for bleeding duodenal ulcer (1). Revision or immediate replacement was performed in 10 (4%): slippage (5), obstruction (4), and leak from the reservoir (1). Port/tubing problems were the reason for reoperations in 13 (5%): infection (5), crack at tubing-port connection (6), and port rotation (2). Port removal for infection was followed later by port replacement (average 9 months). Overall, slippage occurred in 8 (3%), obstruction in 4 (1.5%), leak from reservoir in 7 (3%), and infection in 5 (2%) patients. Fifteen device-related problems occurred during our first 100 cases and 12 subsequently (P = 0.057). Permanent LapBand loss was only 5 per cent, leading to overall rate of 95 per cent of LapBand preservation as a restrictive device.


Assuntos
Gastroplastia/instrumentação , Falha de Prótese , Humanos , Laparoscopia , Obesidade Mórbida/cirurgia , Implantação de Prótese/instrumentação , Reoperação , Estudos Retrospectivos
2.
Am Surg ; 70(10): 918-21, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15529851

RESUMO

Early detection of complications after laparoscopic Roux-en-Y gastric bypass (LRYGB) can be difficult because of the subtle clinical findings in obese patients. Consequently, routine postoperative upper gastrointestinal contrast studies (UGI) have been advocated for detection of leak from the gastrojejunostomy. The medical records of 368 consecutive patients undergoing LRYGB were analyzed to determine the efficacy of selective use of radiological studies after LRYGB. Forty-one patients (11%) developed signs suggestive of complications. Of the 41 symptomatic patients, two were explored urgently, 39 (10%) had radiological studies, and 16 of them (41%) were diagnosed with postoperative complications. Overall morbidity of the series was 4.8 per cent. Four patients (1.1%) developed a leak from the gastrojejunostomy and were correctly diagnosed by computerized tomography (CT). The sensitivity and specificity of CT in determining leak was 100 per cent, with positive and negative predictive value of 100 per cent. The mortality of the series was 0 per cent. No radiologic studies were performed in asymptomatic patients, and no complications developed in these patients. Our results show that selective radiological evaluation in patients with suspected complications after LRYGB is safe. High sensitivity makes CT the test of choice in patients with suspected complication after LRYGB. Routine radiological studies are not warranted.


Assuntos
Anastomose em-Y de Roux , Derivação Gástrica , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste/farmacologia , Humanos , Laparoscopia , Obesidade Mórbida/cirurgia , Cuidados Pós-Operatórios , Estudos Retrospectivos , Resultado do Tratamento , Trato Gastrointestinal Superior/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA