Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Thorax ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914469

RESUMO

RATIONALE: Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm function is not well understood. We hypothesised that endoscopic lung volume reduction increases its strength by modifying its shape. OBJECTIVES: To investigate changes in both diaphragm shape and strength induced by the insertion of endobronchial valves. METHODS: In 19 patients, both the diaphragm shape and strength were investigated respectively by 3D Slicer software applied on CT scans acquired at functional residual capacity and by transdiaphragmatic pressure measurements by bilateral magnetic stimulation of the phrenic nerves before and 3 months after unilateral valves insertion. MEASUREMENTS AND MAIN RESULTS: After lung volume reduction (median (IQR), 434 mL (-597 to -156], p<0.0001), diaphragm strength increased (transdiaphragmatic pressure: 3 cmH2O (2.3 to 4.2), p<0.0001). On the treated side, this increase was associated with an increase in the coronal (16 mm (13 to 24), p<0.0001) and sagittal (26 mm (21 to 30), p<0.0001) lengths as well as in the area of the zone of apposition (62 cm2 (3 to 100), p<0.0001) with a decrease in the coronal (8 mm (-12 to -4), p<0.0001) and sagittal (9 mm (-18 to -2), p=0.0029) radii of curvature. CONCLUSIONS: Endoscopic lung volume reduction modifies the diaphragm shape by increasing its length and its zone of apposition and by decreasing its radius of curvature on the treated side, resulting in an increase in its strength. TRIAL REGISTRATION NUMBER: NCT05799352.

2.
Radiology ; 310(2): e232558, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38411514

RESUMO

Members of the Fleischner Society have compiled a glossary of terms for thoracic imaging that replaces previous glossaries published in 1984, 1996, and 2008, respectively. The impetus to update the previous version arose from multiple considerations. These include an awareness that new terms and concepts have emerged, others have become obsolete, and the usage of some terms has either changed or become inconsistent to a degree that warranted a new definition. This latest glossary is focused on terms of clinical importance and on those whose meaning may be perceived as vague or ambiguous. As with previous versions, the aim of the present glossary is to establish standardization of terminology for thoracic radiology and, thereby, to facilitate communications between radiologists and clinicians. Moreover, the present glossary aims to contribute to a more stringent use of terminology, increasingly required for structured reporting and accurate searches in large databases. Compared with the previous version, the number of images (chest radiography and CT) in the current version has substantially increased. The authors hope that this will enhance its educational and practical value. All definitions and images are hyperlinked throughout the text. Click on each figure callout to view corresponding image. © RSNA, 2024 Supplemental material is available for this article. See also the editorials by Bhalla and Powell in this issue.


Assuntos
Comunicação , Diagnóstico por Imagem , Humanos , Bases de Dados Factuais , Radiologistas
3.
Eur Radiol ; 31(9): 6605-6611, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33569623

RESUMO

OBJECTIVES: To investigate the proportion of clinical scenarios covered by EURO-2000 Guidelines and ESR iGuide, and assess compliance with both guidelines. METHODS: The clinical indication on archived request forms for head, chest, abdomen-pelvis, and spine CT examinations performed in three hospitals in January 2018 was retrospectively matched with EURO-2000 Guidelines and ESR iGuide. For clinical scenarios addressed in the guidelines, the compliance with the guidelines was assessed. Analysis was performed on pooled data from the three centres and further stratified by centre, body region, and prescriber's specialisation. The differences in categorical data distributions between centres, body regions, and prescribers' specialisations were assessed with paired McNemar's χ2 tests. RESULTS: A total of 6,812 requests for 7,217 CT examinations were analysed. Sixty-five percent of clinical situations that lead to prescribing CT examinations were addressed in EURO-2000 Guidelines compared with 81% for ESR iGuide. Proportions of clinical scenarios covered by the guidelines were statistically different between centres and body regions (p < 0.001) and varied according to prescribers' specialisations (p ranging from < 0.001 to 0.531). Both EURO-2000 Guidelines and ESR iGuide encompassed more clinical scenarios in certain body regions, favouring, e.g. spine and head over abdomen and chest. The proportion of "unjustified examinations" was greater according to EURO-2000 Guidelines (46%) than ESR iGuide (23%) (p < 0.001). CONCLUSIONS: Both EURO-2000 Guidelines and ESR iGuide do not address numerous common clinical scenarios. The proportions of scenarios addressed differ according to the centre, body region, and prescribers' specialisation. Any estimation of compliance with referral guidelines is therefore of relative significance. KEY POINTS: • ESR iGuide performs better than earlier EURO-2000 Guidelines for the coverage of all possible clinical scenarios leading to CT referrals. • Differences in coverage of clinical scenarios by both referral guidelines are observed for different body regions and/or prescribers' subspecialties. • As referral guidelines are incomplete, any estimation of justified or unjustified CT requests is of relative significance.


Assuntos
Exame Físico , Tomografia Computadorizada por Raios X , Abdome , Humanos , Encaminhamento e Consulta , Estudos Retrospectivos
4.
BMC Pulm Med ; 21(1): 135, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33902504

RESUMO

BACKGROUND: The surgical lung biopsy (SLB) is the recommended sampling technique when the pathological analysis of the lung is required in the work-up of an interstitial lung disease (ILD) but trans-bronchial lung cryobiopsy (TBLC) is increasingly recognized as an alternative approach. As TBLCs have lower mortality and morbidity risks than SLB, this study aimed to investigate the safety of TBLCs in patients at higher risk of complications and for whom SLB was not considered as an alternative. METHOD: This prospective study was conducted in two hospitals in which TBLCs were performed in patients with body mass index (BMI) > 35, and/or older than 75 years, and/or with severely impaired lung function (FVC < 50% or DLCO < 30%), and/or systolic pulmonary artery pressure > 45 mmHg, and/or a clinically significant cardiac disease. Patients with any of these risk factors constituted the high-risk group. Clinical outcomes were compared with those obtained in patients without these risk factors (low-risk group). RESULTS: Ninety-six patients were included between April 2015 and April 2020, respectively 38 and 58 in the high-risk or the low-risk group. No statistically significant difference was observed between both groups in terms of severity and rate of bleeding, pneumothorax, or duration of hospital stay (p value ranging from 0.419 to 0.914). CONCLUSION: This preliminary study on a limited number of patients suggests that TBLC appears safe in those in whom lung biopsy is at high-risk of complications according to their age, BMI, lung impairment, and cardiac comorbidities.


Assuntos
Doenças Pulmonares Intersticiais/patologia , Pulmão/patologia , Idoso , Biópsia/efeitos adversos , Biópsia/métodos , Brônquios , Criocirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Fatores de Risco
5.
Crit Care Med ; 48(11): e1087-e1090, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32769623

RESUMO

OBJECTIVES: To assess the role of thromboprophylaxis regimens on the occurrence of pulmonary embolism in coronavirus disease 2019 patients. DESIGN: Retrospective analysis of prospectively collected data on coronavirus disease 2019 patients, included between March 10, and April 30, 2020. SETTING: ICU of an University Hospital in Belgium. PATIENTS AND INTERVENTIONS: Critically ill adult mechanically ventilated coronavirus disease 2019 patients were eligible if they underwent a CT pulmonary angiography, as part of the routine management in case of persistent hypoxemia or respiratory deterioration. The primary endpoint of this study was the occurrence of pulmonary embolism according to the use of standard thromboprophylaxis (i.e. subcutaneous enoxaparin 4,000 international units once daily) or high regimen thromboprophylaxis (i.e. subcutaneous enoxaparin 4,000 international units bid or therapeutic unfractioned heparin). MEASUREMENTS AND MAIN RESULTS: Of 49 mechanically ventilated coronavirus disease 2019, 40 underwent CT pulmonary angiography after a median of 7 days (4-8 d) since ICU admission and 12 days (9-16 d) days since the onset of symptoms. Thirteen patients (33%) were diagnosed of pulmonary embolism, which was bilateral in six patients and localized in the right lung in seven patients. D-dimers on the day of CT pulmonary angiography had a predictive accuracy of 0.90 (95% CIs: 0.78-1.00) for pulmonary embolism. The use of high-regimen thromboprophylaxis was associated with a lower occurrence of pulmonary embolism (2/18; 11%) than standard regimen (11/22, 50%-odds ratio 0.13 [0.02-0.69]; p = 0.02); this difference remained significant even after adjustment for confounders. Six patients with pulmonary embolism (46%) and 14 patients without pulmonary embolism (52%) died at ICU discharge (odds ratio 0.79 [0.24-3.26]; p = 0.99). CONCLUSIONS: In this study, one third of coronavirus disease 2019 mechanically ventilated patients have a pulmonary embolism visible on CT pulmonary angiography. High regimen thromboprophylaxis may decrease the occurrence of such complication.


Assuntos
Anticoagulantes/uso terapêutico , Infecções por Coronavirus/tratamento farmacológico , Estado Terminal/terapia , Pneumonia Viral/tratamento farmacológico , Embolia Pulmonar/prevenção & controle , Trombose Venosa/prevenção & controle , Adulto , Betacoronavirus , COVID-19 , Infecções por Coronavirus/complicações , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Embolia Pulmonar/etiologia , Estudos Retrospectivos , SARS-CoV-2 , Resultado do Tratamento , Trombose Venosa/etiologia
6.
Eur Radiol ; 30(8): 4641-4647, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32270316

RESUMO

OBJECTIVES: To estimate the variability of X-ray diagnostic reference levels (DRLs) depending on the number of X-ray devices and data per device. METHODS: Dose-area products (DAP) were collected by the national nuclear control agency from the 590 devices installed in 345 medical centers in the country. From 2015 to 2017, the number of chest (postero-anterior (PA) view alone, and both postero-anterior and lateral views (PA/LAT)), abdomen, pelvis, and lumbar spine examinations collected in these centers ranged from 23,000 to 77,000. The impact of the number of devices and DAP data per device on DRLs' variabilities (95th confidence intervals divided by medians) is estimated using a bootstrapping method as a function of the number of devices and DAP per device. RESULTS: The DRLs' variabilities ranged from 30 to 200% depending on the number of devices and DAP data per device but stabilized at 30% when the number of devices was higher than 200 for chest PA and abdomen examinations, 300 for lumbar spine and pelvis examinations, and 400 for chest PA/LAT examinations, regardless of the number of DAP data per device. Extrapolations of our results suggest that thousands of devices are necessary to reduce DRLs' variabilities to 10%. CONCLUSION: DAP-related DRL variabilities are high but only moderately influenced by the number of DAP data per device and of devices provided this number is higher than 200 to 400 devices according to the type of examination. Harmonization of methods of data collection between the authorities of the EU states should be recommended. KEY POINTS: • DAP-related DRLs are not fixed values but ranges of values with at least 30% variability. • DAP-related DRLs strongly depend on the number of devices included when lower than 100. • If the number of devices included exceeds 200 to 400, the DRLs' variabilities do not depend on the number of DAP per device and should not exceed 30%.


Assuntos
Níveis de Referência de Diagnóstico , Radiografia/normas , Humanos , Doses de Radiação
7.
Eur Radiol ; 30(11): 6204-6212, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32548647

RESUMO

OBJECTIVES: To evaluate how pulmonary artery (PA) distensibility performs in detecting pulmonary hypertension due to left heart disease (PH-LHD) in comparison with parameters from ungated computed tomography (CT) and echocardiography. METHODS: One hundred patients (79 men, mean age = 63 ± 17 years) with either severe heart failure with reduced ejection fraction (HFrEF), aortic stenosis, or primary mitral regurgitation prospectively underwent right heart catheterization, ungated CT, ECG-gated CT, and echocardiography. During the ECG-gated CT, the right PA distensibility was calculated. In ungated CT, dPA, dPA/AA, the ratio of dPA to the diameter of the vertebra, segmental PA diameter, segmental PA-to-bronchus ratio, and the main PA volume were measured; the egg-and-banana sign was recorded. During echocardiography, the tricuspid regurgitation (TR) gradient was measured. The areas under the ROC curves (AUC) of these signs were computed and compared with DeLong test. Correlation between PA distensibility and PA pressure (PAP) was investigated through Pearson's coefficient. RESULTS: PA distensibility was lower in patients with PH than in those without PH (11.4 vs. 21.2%, p < 0.001) and correlated negatively with mean PAP (r = - 0.72, p < 0.001). Age, PA size, and mean PAP were independent predictors of PA distensibility. PA distensibility < 18% detected PH-LHD with 96% sensitivity and 73% specificity; its AUC was 0.92, larger than that of any other sign at ungated CT and TR gradient (AUC ranging from 0.54 to 0.83, DeLong: p ranging from 0.020 to < 0.001). CONCLUSION: PA distensibility on an ECG-gated CT can detect PH-LHD better than the parameters reflecting PA dilatation in ungated CT or TR gradient in the echocardiography of patients with severe HFrEF, aortic stenosis, or mitral regurgitation. KEY POINTS: • In left heart disease, pulmonary artery distensibility is lower in patients with PH than in those without pulmonary hypertension (11.4 vs. 21.2%, p < 0.001). • In left heart disease, pulmonary artery distensibility detects pulmonary hypertension with an area under the receiver operating curve of 0.92. • In left heart disease, the area under the receiver operating curve of pulmonary artery distensibility for detecting pulmonary hypertension is larger than that of all other signs at ungated CT (p from 0.019 to < 0.001) and tricuspid regurgitation gradient at echocardiography (p = 0.020).


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Técnicas de Imagem de Sincronização Cardíaca , Ecocardiografia/métodos , Feminino , Coração/fisiopatologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Tamanho do Órgão , Artéria Pulmonar/patologia , Artéria Pulmonar/fisiopatologia , Volume Sistólico , Tomografia Computadorizada por Raios X/métodos
8.
Skeletal Radiol ; 49(7): 1141-1147, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32103296

RESUMO

OBJECTIVE: To prospectively compare the prevalence and frequency of subchondral bone marrow edema (BME) in the lumbar facet joints of low back pain patients and healthy subjects. MATERIALS AND METHODS: Lumbar magnetic resonance imaging (MRI) examinations were performed on 55 asymptomatic participants (18 men; age range 21-63; mean 36 ± 12 years; body mass index (BMI) range 16-31; mean 22.6 ± 3.2 kg/m2) and 79 low back pain patients (36 men; age range 18-77; mean 47 ± 14 years; BMI range 18-40; mean 27.8 ± 4.4 kg/m2). In both groups, facet joint subchondral BME signal was evaluated using T2-weighted STIR imaging, and facet joint osteoarthritis was characterized as mild, moderate, and severe. RESULTS: The BME signal was found in seven asymptomatic participants (12.7%) and 28 low back pain patients (35.4%) (P = 0.003). A significant portion of the patients (15.2%) presented more than one BME signal (P = 0.011). By pooling the ten facet joints of all subjects in each group, a significant difference in osteoarthritis grade distribution was observed between the two groups (P < 0.001). When adjusted for low back pain status, age, BMI, Modic type 1, disk herniation, and facet joint osteoarthritis maximal grade, only the latter was significantly associated with the facet joint BME signal (P < 0.001). CONCLUSION: Despite the higher prevalence and frequency of the BME signal in facet joints of low back pain patients compared to that in healthy subjects, the signal was found to be associated with the severity of the patients' osteoarthritis and not with their low back pain status.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Dor Lombar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoartrite da Coluna Vertebral/diagnóstico por imagem , Articulação Zigapofisária/diagnóstico por imagem , Adolescente , Adulto , Idoso , Doenças Assintomáticas , Doenças da Medula Óssea/epidemiologia , Edema/epidemiologia , Feminino , Humanos , Dor Lombar/epidemiologia , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite da Coluna Vertebral/epidemiologia , Prevalência , Estudos Prospectivos
9.
Eur Radiol ; 29(10): 5264-5271, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30963277

RESUMO

OBJECTIVES: To estimate the variability of CT diagnostic reference levels (DRLs) according to the methods used for computing collected data. METHODS: Dose-length products (DLP) were collected by our national nuclear control agency from the 250 devices installed in 140 medical centers in the country. In 2015, the number of head, thorax, abdomen, and lumbar spine examinations collected in these centers ranged from approximately 20,000 to 42,000. The impact on DRLs of the number of devices considered, as well as the differences in descriptive statistics (mean vs. median DLP) or methods of pooling DLP data (all devices vs. all patients), was investigated. Variability in DRLs was investigated using a bootstrapping method as a function of the numbers of devices and examinations per device. RESULTS: As expected, DRLs derived from means were higher than those from medians, with substantial differences between device- and patient-related DRLs. Depending on the numbers of devices and DLP data per device, the variability ranged from 10 to 40% but was stabilized at a level of 10-20% if the number of devices was higher than 50 to 60, regardless of the number of DLP data per device. CONCLUSION: Number of devices and of DLP data per device, descriptive statistics, and pooling data influence DRLs. As differences in methods of computing survey data can artificially influence DRLs, harmonization among national authorities should be recommended. KEY POINTS: • Due to CT dose variability, that of DRLs is at least of 10%. • DRLs derived from medians are lower than from means and differ from those obtained by pooling all patient data. • Fifty to 60 devices should be sufficient for estimating national DRLs, regardless of the number of data collected per device.


Assuntos
Abdome/efeitos da radiação , Cabeça/efeitos da radiação , Vértebras Lombares/efeitos da radiação , Tórax/efeitos da radiação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Biometria , Europa (Continente) , Humanos , Exame Físico , Doses de Radiação , Valores de Referência , Projetos de Pesquisa , Inquéritos e Questionários
10.
Eur Radiol ; 29(10): 5307-5313, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30877467

RESUMO

OBJECTIVES: To determine the variabilities of dose-area-products (DAP) of frequent X-ray examinations collected for comparison with diagnostic reference levels (DRLs). METHODS: DAP values of chest, abdomen, and lumbar spine examinations obtained on devices from two manufacturers were collected in three centers over 1 to 2 years. The variability of the average DAP results defined as the 95% confidence interval in percentage of their median value was calculated for increasing sample sizes, each examination and center. We computed the sample sizes yielding variabilities lower or equal to 25% and 10%. The effect of narrowing patient selection based on body weight was also investigated (ranges of 67-73 Kg, or 60-80 Kg). RESULTS: DAP variabilities ranged from 75 to 170% of the median value when collecting small samples (10 to 20 DAP). To reduce this variability, larger samples are needed, collected over up to 2 years, regardless of the examination and center. A variability ≤ 10% could only be reached for chest X-rays, requiring up to 800 data. For the abdomen and lumbar spine, the lowest achievable variability was 25%, regardless of the body weight selection, requiring up to 400 data. CONCLUSION: Variabilities in DAP collected through small samples of ten data as recommended by authorities are very high, but can be reduced down to 25% (abdomen and lumbar spine) or even 10% (chest) through a substantial increase in sample sizes. Our findings could assist radiologists and regulatory authorities in estimating the reliability of the data obtained when performing X-ray dose surveys. KEY POINTS: • Low but reasonable variabilities cannot be reached with samples sized as recommended by regulatory authorities. Higher numbers of DAP values are required to reduce the variability. • Variabilities of 10% for the chest and 25% for abdomen and lumbar spine examinations are achievable, provided large samples of data are collected over 1 year. • Our results could help radiologists and authorities interpret X-rays dose surveys.


Assuntos
Abdome/efeitos da radiação , Vértebras Lombares/efeitos da radiação , Tórax/efeitos da radiação , Algoritmos , Peso Corporal , Humanos , Exame Físico/métodos , Doses de Radiação , Proteção Radiológica , Radiografia/estatística & dados numéricos , Reprodutibilidade dos Testes , Tamanho da Amostra , Inquéritos e Questionários , Raios X
11.
Eur Radiol ; 28(4): 1420-1426, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29079913

RESUMO

OBJECTIVES: To test the hypothesis that referral guidelines are not sufficiently known by prescribers and that medico-legal concerns could influence the prescription of radiographs in minor chest trauma. METHODS: We submitted a questionnaire including a typical clinical history and questions on reasons for prescribing radiographs of the ribs in minor chest trauma to 112 prescriptors (33 residents, 18 surgeons, 7 internists, 24 general practitioners and 30 ER physicians). All accepted to participate. Comparisons were performed by Fisher's exact test followed by a post-hoc analysis and by a McNemar test. RESULTS: Fifty-eight percent of prescriptors proposed rib radiographs, most (89%) being unaware of the guidelines. Only 11% of them changed their intention to order radiographs after information on referral guidelines and radiation dose (P=0.057). The mean dose delivered by rib radiographs was 38 times higher than that of a chest X-ray. Legal and medico-legal concerns (requirements from insurance policies and avoidance of lawsuits) were the main reasons for requesting radiographs. CONCLUSION: Unsharpness of guidelines in addition to social and medico-legal issues, rather than medical reasons or the lack of knowledge of the guidelines, strongly influence the prescription of radiographs of the ribs in minor chest trauma. KEY POINTS: • Most prescriptors order radiographs of the ribs in minor chest trauma. • Only few prescriptors are aware of referral guidelines. • Information on guidelines does not change their need for radiographs. • Motivations for ordering radiographs are rather legal than medical, but poor compliance to guidelines could also be explained by their unsharpness. • Radiation dose of rib radiographs was 38 times that of a PA chest radiograph.


Assuntos
Fidelidade a Diretrizes/estatística & dados numéricos , Proteção Radiológica/métodos , Proteção Radiológica/estatística & dados numéricos , Radiografia/estatística & dados numéricos , Encaminhamento e Consulta/estatística & dados numéricos , Traumatismos Torácicos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia/métodos , Inquéritos e Questionários , Adulto Jovem
12.
AJR Am J Roentgenol ; 210(5): 1042-1058, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29528711

RESUMO

OBJECTIVE: The purpose of this study is to investigate the magnitude of differences between attenuation values measured on virtual unenhanced images and true unenhanced images obtained using third-generation dual-source dual-energy CT (DECT). SUBJECTS AND METHODS: A total of 83 patients requiring thoracoabdominal CT for cancer workup were included in this prospective study. CT examinations included true unenhanced acquisitions (tube potential, 120 kVp) and arterial and portal phase dual-energy CT (DECT) acquisitions (tube potential, 100 kVp and Sn 150 kVp [where Sn denotes the interposition of a tin filter in the high-energy beam]; tube current-exposure time product, 190 and 95 mAs). Virtual unenhanced images were created using two commercially available DECT postprocessing algorithms, one of which was designed to create liver images (hereafter referred to as VNC1 images) and the other of which was designed to create images of organs containing minor amounts of fat (hereafter referred to as VNC2 images). Attenuation values on the liver, spleen, paraspinal muscles, retroperitoneal fat, renal cortex and medulla, and gallbladder and bladder lumens were measured. RESULTS: The attenuation values of all tissues were significantly different between virtual unenhanced and true unenhanced images (p = < 0.001-0.042), except for the liver and spleen in the portal phase and muscles in both phases. When statistically significant, correlations between these differences and body mass index (weight in kilograms divided by the square of height in meters) depended on the tissue imaged and algorithm used. The percentage of cases in which these differences were 10 HU or greater was 1% for the liver and approximately 5% for the spleen and muscles, regardless of the algorithm and phase, but on VNC1 images it reached approximately 30% for the kidney, 70% for the gallbladder and bladder, and depending on the phase, 40-70% for fat. On VNC2 images, the percentage of cases in which these differences were 20 HU or greater was approximately 90% for fat. CONCLUSION: Abdominal virtual unenhanced images obtained with third-generation dual-source DECT still should not replace true unenhanced images because of substantial differences in attenuation measurements for fluid, fat, and renal tissues.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
AJR Am J Roentgenol ; 210(2): 358-363, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29166148

RESUMO

OBJECTIVE: The objective of our study was to evaluate in vivo urinary calculus characterization with third-generation dual-source dual-energy CT (DECT) at reduced versus standard radiation dose. SUBJECTS AND METHODS: One hundred fifty-three patients requiring unenhanced CT for suspected or known urolithiasis were prospectively included in our study. They underwent two acquisitions at reduced-dose CT (90 kV and 50 mAsref; Sn150 kV and 31 mAsref, where Sn denotes the interposition of a tin filter in the high-energy beam) and standard-dose CT (90 kV and 50 mAsref; Sn150 kV and 94 mAsref). One radiologist interpreted the reduced-dose examinations before the standard-dose examinations during the same session. Among 103 patients (23 women, 80 men; mean age ± SD, 50 ± 15 years; age range, 18-82 years) with urolithiasis, dedicated DECT software measured the maximal diameter and CT numbers, calculated the DECT number ratio, and labeled with a color code each calculus visualized by the radiologist as uric acid (UA) or non-UA. Volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded. RESULTS: The radiologist visualized 279 calculi on standard-dose CT and 262 on reduced-dose CT; 17 calculi were missed on reduced-dose CT, all of which were ≤ 3 mm. Among the 262 calculi visualized at both doses, the CT number ratio was obtained with the software for 227 calculi and was not different between the doses (p = 0.093). Among these 262 calculi, 197 were labeled at both doses; 194 of the 197 labeled calculi were labeled with the same color code. Among the 65 remaining calculi, 48 and 61 (all ≤ 5 mm) were not labeled at standard-dose and reduced-dose CT (p = 0.005), respectively. At reduced-dose CT, the mean CTDIvol was 2.67 mGy and the mean DLP was 102.2 mGy × cm. CONCLUSION: With third-generation dual-source DECT, a larger proportion of calculi ≤ 5 mm are not characterized as UA or non-UA at a reduced dose.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Software , Ácido Úrico , Cálculos Urinários/química
14.
Eur Radiol ; 27(1): 365-373, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27048530

RESUMO

OBJECTIVES: To determine variability of volume computed tomographic dose index (CTDIvol) and dose-length product (DLP) data, and propose a minimum sample size to achieve an expected precision. METHODS: CTDIvol and DLP values of 19,875 consecutive CT acquisitions of abdomen (7268), thorax (3805), lumbar spine (3161), cervical spine (1515) and head (4106) were collected in two centers. Their variabilities were investigated according to sample size (10 to 1000 acquisitions) and patient body weight categories (no weight selection, 67-73 kg and 60-80 kg). The 95 % confidence interval in percentage of their median (CI95/med) value was calculated for increasing sample sizes. We deduced the sample size that set a 95 % CI lower than 10 % of the median (CI95/med ≤ 10 %). RESULTS: Sample size ensuring CI95/med ≤ 10 %, ranged from 15 to 900 depending on the body region and the dose descriptor considered. In sample sizes recommended by regulatory authorities (i.e., from 10-20 patients), mean CTDIvol and DLP of one sample ranged from 0.50 to 2.00 times its actual value extracted from 2000 samples. CONCLUSIONS: The sampling error in CTDIvol and DLP means is high in dose surveys based on small samples of patients. Sample size should be increased at least tenfold to decrease this variability. KEY POINTS: • Variability of dose descriptors is high regardless of the body region. • Variability of dose descriptors depends on weight selection and the region scanned. • Larger samples would reduce sampling errors of radiation dose data in surveys. • Totally or partially disabling AEC reduces dose variability and increases patient dose. • Median values of dose descriptors depend on the body weight selection.


Assuntos
Doses de Radiação , Inquéritos e Questionários , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tamanho da Amostra , Tomografia Computadorizada por Raios X/métodos
15.
Radiology ; 278(3): 888-96, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26458208

RESUMO

PURPOSE: To quantify the reproducibility and accuracy of experienced thoracic radiologists in differentiating between subsolid and solid pulmonary nodules at CT. MATERIALS AND METHODS: The institutional review board of Beth Israel Deaconess Medical Center approved this multicenter study. Six thoracic radiologists, with a mean of 21 years of experience in thoracic radiology (range, 17-22 years), selected images of 10 solid and 10 subsolid nodules to create a database of 120 nodules; this selection served as the reference standard. Each radiologist then interpreted 120 randomly ordered nodules in two different sessions that were separated by a minimum of 3 weeks. The radiologists classified whether or not each nodule was subsolid. Inter- and intraobserver agreement was assessed with a κ statistic. The number of correct classifications was calculated and correlated with nodule size by using Bland-Altman plots. The relationship between disagreement and nodule morphologic characteristics was analyzed by calculating the intraclass correlation coefficient. RESULTS: Interobserver agreement (κ) was 0.619 (range, 0.469-0.745; 95% confidence interval (CI): 0.576, 0.663) and 0.670 (range, 0.440-0.839; 95% CI: 0.608, 0.733) for interpretation sessions 1 and 2, respectively. Intraobserver agreement (κ) was 0.792 (95% CI: 0.750, 0.833). Averaged for interpretation sessions, correct classification was achieved by all radiologists for 58% (70 of 120) of nodules. Radiologists agreed with their initial determination (the reference standard) in 77% of cases (range, 45%-100%). Nodule size weakly correlated with correct classification (long axis: Spearman rank correlation coefficient, rs = 0.161 and P = .049; short axis: rs = 0.128 and P = .163). CONCLUSION: The reproducibility and accuracy of thoracic radiologists in classifying whether or not a nodule is subsolid varied in the retrospective study. This inconsistency may affect surveillance recommendations and prognostic determinations.


Assuntos
Competência Clínica , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial , Humanos , Nódulos Pulmonares Múltiplos/patologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes
16.
Eur J Nucl Med Mol Imaging ; 43(5): 832-838, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26508291

RESUMO

PURPOSE: Focal areas of FDG uptake may occur at the bronchial stump following curative lobectomy for non-small-cell lung carcinoma (NSCLC), even in the absence of suspicious CT changes. The purpose of our study was to investigate the significance of such PET/CT findings. METHODS: FDG-PET/CT scans performed in 54 patients after lobectomy for NSCLC were reviewed. The presence of focal areas of FDG uptake at the bronchial stump, associated CT abnormalities, SUVmax, and normalized SUV (SUVnorm = SUVmax/mean liver SUV) were recorded. Final diagnosis was based on biopsy or imaging follow-up. RESULTS: Focal areas of FDG uptake at the bronchial stump were detected in 30 patients (56 %). Mean SUVmax was 4.0 ± 1.9 (range; 2.2-12.1) and mean SUVnorm was 1.8 ± 0.8 (range; 0.9-4.5). Biopsy showed recurrence in two patients. In these patients, SUVnorm was respectively 4.4 and 4.5 (with SUVmax of 8.8 and 12.1), whereas SUVnorm was lower than 4.0 in those without recurrence, with mean SUVnorm of 1.6 ± 0.5 (range; 0.9-3.4) and mean SUVmax of 3.6 ± 0.9 (range; 2.2-5.8). The CT component of the PET/CT revealed ill-defined peribronchial soft tissue opacity only in both patients with recurrence. CONCLUSION: FDG uptake at the bronchial stump is a frequent finding after pulmonary lobectomy. Moderate levels of FDG uptake (i.e., SUVnorm < 4.0) without corresponding abnormal CT findings might be a dual criterion for diagnosing benign post-surgical changes.


Assuntos
Brônquios/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Compostos Radiofarmacêuticos , Idoso , Brônquios/cirurgia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Feminino , Humanos , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Período Pós-Operatório
17.
Eur Radiol ; 26(8): 2663-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26577376

RESUMO

PURPOSE: To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. MATERIALS AND METHODS: This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. RESULTS: Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). CONCLUSION: Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. KEY POINTS: • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.


Assuntos
Abdome/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Auditoria Clínica , Vértebras Lombares/diagnóstico por imagem , Melhoria de Qualidade , Tomografia Computadorizada por Raios X/normas , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Fidelidade a Diretrizes , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tempo
18.
Radiology ; 274(1): 260-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25153159

RESUMO

PURPOSE: To retrospectively determine the potential of organ-based tube current modulation ( OBTCM organ-based tube current modulation ) to reduce the radiation dose delivered to breast tissue by computed tomography (CT) by determining breast angular position in relation to the zones of decreased versus increased radiation. MATERIALS AND METHODS: The authors obtained institutional review board approval for this study and patients' written informed consent. In two academic centers (center A: Beth Israel Deaconess Medical Center, Boston, Mass; and center B: Hôpital André Vésale, Montignies-le-Tilleul, Belgium), data were collected from clinical thoracic CT examinations performed in 498 women (mean age, 60 years; age range, 18-95 years) in the supine position and 34 women (mean age, 53 years; age range, 18-84 years) in the prone position. One radiologist in each center determined breast tissue location and measured its inner and outer boundaries with respect to the isocenter of the CT examination. The percentages of women with breast tissue within and those with breast tissue outside the zone of decreased radiation delivered by OBTCM organ-based tube current modulation were determined. The location of breast tissue was correlated with patient age and with sagittal and coronal diameters of the thorax by using the Student t test, Fisher exact test, and Pearson correlation. RESULTS: None of the women lying in the supine position had the entirety of the breast tissue located within the reduced-dose zone. Breast tissue was located in the increased-dose zone in 99% of women lying supine and in 82% of women lying prone. CONCLUSION: The breast angular position of almost all women was higher than the angular limit of the reduced versus the increased dose in OBTCM organ-based tube current modulation . No woman, regardless of supine or prone position, had all breast tissue within the reduced-dose zone.


Assuntos
Mama/efeitos da radiação , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica , Boston , Feminino , Humanos , Pessoa de Meia-Idade , Posicionamento do Paciente , Imagens de Fantasmas , Proteção Radiológica , Estudos Retrospectivos
19.
Radiology ; 277(3): 853-62, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25989594

RESUMO

PURPOSE: To determine the effect of bronchodilation on airway indexes reflecting airway disease in patients with chronic obstructive pulmonary disease (COPD) and to determine the minimum number of segmental and subsegmental airways required. MATERIALS AND METHODS: This study was approved by the local ethical committee, and written informed consent was obtained from all subjects. Twenty patients with COPD who had undergone pre- and postbronchodilator pulmonary function tests and computed tomographic (CT) examinations were prospectively included. Eight healthy volunteers underwent two CT examinations. Luminal area and wall thickness (WT) of third- and fourth-generation airways were measured twice by three readers. The percentage of total airway area occupied by the wall and the square root of wall area at an internal perimeter of 10 mm (√WAPi10) were calculated. The effects of pathologic status, session, reader, bronchodilation, and CT examination were assessed by using mixed linear model analyses. The number of airways to measure for a definite percentage error of √WAPi10 was computed by using a bootstrap method. RESULTS: There were no significant session, reader, or bronchodilation effects on WT in third-generation airways and √WAPi10 in patients with COPD (P values ranging from .187 to >.999). WT in third-generation airways and √WAPi10 were significantly different in patients with COPD and control subjects (P = .018 and <.001, respectively). Measuring 12 third- or fourth-generation airways ensured a maximal 10% error of √WAPi10. CONCLUSION: WT in third-generation airways and √WAPi10 are not significantly different before and after bronchodilation and are different in patients with COPD and control subjects. Twelve is the minimum number of third- or fourth-generation airways required to ensure a maximal 10% error of √WAPi10. (©) RSNA, 2015 Clinical trial registration no. NCT01142531 Online supplemental material is available for this article.


Assuntos
Brônquios/patologia , Broncodilatadores/farmacologia , Broncografia , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Brônquios/efeitos dos fármacos , Feminino , Humanos , Ipratrópio/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Testes de Função Respiratória
20.
Radiology ; 277(1): 192-205, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25961632

RESUMO

The purpose of this statement is to describe and define the phenotypic abnormalities that can be identified on visual and quantitative evaluation of computed tomographic (CT) images in subjects with chronic obstructive pulmonary disease (COPD), with the goal of contributing to a personalized approach to the treatment of patients with COPD. Quantitative CT is useful for identifying and sequentially evaluating the extent of emphysematous lung destruction, changes in airway walls, and expiratory air trapping. However, visual assessment of CT scans remains important to describe patterns of altered lung structure in COPD. The classification system proposed and illustrated in this article provides a structured approach to visual and quantitative assessment of COPD. Emphysema is classified as centrilobular (subclassified as trace, mild, moderate, confluent, and advanced destructive emphysema), panlobular, and paraseptal (subclassified as mild or substantial). Additional important visual features include airway wall thickening, inflammatory small airways disease, tracheal abnormalities, interstitial lung abnormalities, pulmonary arterial enlargement, and bronchiectasis.


Assuntos
Doença Pulmonar Obstrutiva Crônica/classificação , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA