J Orthop Res ; 14(4): 639-46, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8764875

RESUMO

A computer controlled wrist joint motion simulator has been developed that actively moves forearms from cadavers through cyclic planar flexion-extension motions, planar radial-ulnar deviation motions, and combined motions such as circumduction. Hybrid position-force feedback control algorithms are used to determine the wrist flexor and extensor tendon forces necessary to achieve the desired motions. The simulator was used in a series of 12 fresh cadaver forearms to produce both flexion-extension and radial-ulnar deviation motions and was found to cause repeatable, physiological movements. In these experiments, the extensor tendon forces were greater than those of the flexors, typically by a factor of two.