Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Perfusion ; : 2676591241241422, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38537032

RESUMO

PURPOSE: To investigate the impact of direct aortic cannulation (DAC) versus femoral arterial cannulation (FAC) on clinical outcomes of surgery for acute type A aortic dissection. METHODS: PubMed/MEDLINE, Scopus, and Cochrane Central Register of Controlled Trials were searched until August 25, 2023, to conduct a meta-analysis. Primary endpoints of the study were operative mortality and postoperative stroke. Secondary endpoints were cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, temporary neurological dysfunction (TND), combined stroke and TND, re-exploration for bleeding, and need for renal replacement therapy. A random-effect model was used to estimate the pooled effect size, and a leave-one-out method was used for the primary endpoints for sensitivity analysis. RESULTS: 15 studies met our eligibility criteria, including a total of 7941 samples. Operative mortality was significantly lower in the DAC group with a pooled odds ratio (OR) of 0.72 [95% confidence interval (CI): 0.61-0.85)]. Incidence of postoperative stroke was also lower in the DAC group with a pooled OR of 0.79 (95% CI: 0.66-0.94). However, after excluding one study with the greatest weight, the difference became nonsignificant. DAC was also associated with a lower incidence of postoperative TND, and re-exploration for bleeding with a pooled OR of 0.52 (95% CI: 0.37-0.73), and 0.60 (95% CI: 0.47-0.77), respectively. CONCLUSIONS: This meta-analysis showed that patients who underwent ATAAD repair with DAC had a lower incidence of operative mortality, postoperative stroke, TND, and re-exploration for bleeding compared to those who underwent FAC.

2.
Clin Chem ; 67(12): 1618-1627, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34718463

RESUMO

BACKGROUND: Chromogranin A (CgA) is a 48 kDa protein that serves as a diagnostically sensitive, but nonspecific, serum biomarker for neuroendocrine tumors. Immunoassays for CgA are not standardized and have a narrow dynamic range, which requires dilution of concentrated specimens. We developed and validated an antibody-free, liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for CgA without these limitations. METHODS: CgA was extracted from serum using a mixed-mode anion exchange solid-phase extraction plate, digested with trypsin, and analyzed by LC-MS/MS using well-characterized CgA calibration standards. After validation, the mass spectrometry method was compared with the CISBIO immunoassay using 200 serum specimens previously submitted for CgA analysis. Specimens with discordant results were reanalyzed by high-resolution mass spectrometry- (HRMS) -based methods to assess the contribution of truncated and post-translationally modified forms of CgA. RESULTS: The assay had a linear range of 50 to 50 000 ng/mL, recoveries between 89% and 115%, and intra- and interassay imprecision <10%. LC-MS/MS assay results showed a Pearson's correlation of r = 0.953 with the CISBIO immunoassay, with CgA values being a mean 2- to 4-fold higher. Concordance for CgA between the 2 assays was 80.9% (95% CI 72.8%-89.2%), showing substantial agreement. Truncation and posttranslational modification, including 2 phosphorylation sites that had not been previously observed or predicted to our knowledge, did not appear to contribute directly to discordance between the 2 assays. CONCLUSION: Quantification of CgA by LC-MS/MS provides an analytically sensitive and reproducible alternative to commercially available immunoassays.


Assuntos
Cromogranina A , Tumores Neuroendócrinos , Espectrometria de Massas em Tandem , Cromatografia Líquida , Cromogranina A/sangue , Humanos , Imunoensaio , Tumores Neuroendócrinos/diagnóstico , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
3.
J Card Surg ; 36(2): 493-500, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33283359

RESUMO

BACKGROUND: Transcatheter valve-in-valve implantation (TViV) and minimally invasive reoperative aortic valve replacement (MIrAVR) have rapidly increased as alternatives to conventional reoperative surgical AVR. This study reports a single-center experience of patients undergoing TViV and MIrAVR after bioprosthetic valve failure. METHODS: In this retrospective review between March 2009 and October 2018, 68 patients without reoperative full sternotomies, concomitant procedures, active endocarditis, and prior homografts or coronary artery bypass grafting underwent isolated AVR for degenerated aortic bioprostheses. Society of Thoracic Surgeons (STS) risk scores and age are reported as median (interquartile range [IQR]) and length of stay is reported as mean (standard deviation [SD]) due to their characteristics of the distribution. RESULTS: Forty-one (60.3%) patients underwent TViV, and 27 (39.7%) patients underwent MIrAVR. Median [IQR] STS risk scores were 5.7 [4.0-7.8] and 2.0 [1.5-3.4] for TViV and MIrAVR, respectively (p ≤ .001). The median [IQR] age for TViV patients was higher (78 [71-84] vs. 66 [53-72] years, p ≤ 0.001). More permanent pacemakers were implanted (22.2% vs. 9.8%) following MIrAVR. The MIrAVR group had a higher rate of atrial fibrillation (18.5% vs. 9.8%, p = .466). Average (SD) length of stay was less in TViV (5.3 days, SD: 3.4 vs. 8.6 days, SD: 7.4, p = .001). Survival at 1 year was not significantly different for TViV and MIrAVR (94.9% [95% confidence interval [CI]: 81.0%, 98.7%] and 86.9% [95% CI: 64.0%, 95.7%], respectively [p = .969]). CONCLUSIONS: Despite being at higher-risk, patients undergoing TViV had reduced rates of permanent pacemaker implantations and atrial fibrillation, and a shorter hospital stay as compared to MIrAVR. Survival at 1-year was similar between the two groups.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
4.
Clin Chem ; 65(12): 1572-1580, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31628138

RESUMO

BACKGROUND: The ratio of ß-amyloid 1-42 (Aß42) to Aß40 in cerebrospinal fluid (CSF) may be useful for evaluating Alzheimer disease (AD), but quantification is limited by factors including preanalytical analyte loss. We developed an LC-MS/MS assay that limits analyte loss. Here we describe the analytical characteristics of the assay and its performance in differentiating patients with AD from non-AD dementia and healthy controls. METHODS: To measure Aß42/Aß40, we used unique proteolytically derived C-terminal peptides as surrogate markers of Aß40 and Aß42, which were analyzed and quantified by LC-MS/MS. The assay was analytically validated and applied to specimens from individuals with clinically diagnosed AD (n = 102), mild cognitive impairment (n = 37), and non-AD dementias (n = 22), as well as from healthy controls (n = 130). Aß42/Aß40 values were compared with APOE genotype inferred from phenotype, also measured by LC-MS/MS. RESULTS: The assay had a reportable range of 100 to 25000 pg/mL, a limit of quantification of 100 pg/mL, recoveries between 93% and 111%, and intraassay and interassay CV <15% for both peptides. An Aß42/Aß40 ratio cutoff of <0.16 had a clinical sensitivity of 78% for distinguishing patients with AD from non-AD dementia (clinical specificity, 91%) and from healthy controls (clinical specificity, 81%). The Aß42/Aß40 ratio decreased significantly (P < 0.001) with increasing dose of APOE4 alleles. CONCLUSIONS: This assay can be used to determine Aß42/Aß40 ratios, which correlate with the presence of AD.


Assuntos
Peptídeos beta-Amiloides/análise , Fragmentos de Peptídeos/análise , Espectrometria de Massas em Tandem/métodos , Idoso , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Cromatografia Líquida/métodos , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/metabolismo , Demência/diagnóstico , Demência/metabolismo , Feminino , Ensaios de Triagem em Larga Escala/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/líquido cefalorraquidiano , Sensibilidade e Especificidade , Proteínas tau/líquido cefalorraquidiano
6.
J Strength Cond Res ; 32(9): 2425-2434, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29985225

RESUMO

Fragala, MS, Goldman, SM, Goldman, MM, Bi, C, Colletti, JD, Arent, SM, Walker, AJ, and Clarke, NJ. Measurement of cortisol and testosterone in athletes: Accuracy of LC-MS/MS assays for cortisol and testosterone measurement in whole-blood microspecimens. J Strength Cond Res 32(9): 2425-2434, 2018-Biomarker monitoring provides insight into athletes' training tolerance but is limited by the need for office-based specimen collection. To facilitate self-collection during training, we developed liquid chromatography-tandem mass spectrometry-based tests that measure circulating total cortisol and testosterone using a finger stick volumetric absorptive microsampler. Here, we describe the analytical validation of these tests. Forty-six Division I athletes (18-22 years, 30 women, 16 men) provided a 20-µL finger stick microspecimen and a 5-ml venous blood specimen from the forearm; the venous blood sample was analyzed using both normal volume serum analysis and analysis of dried whole blood (from the microsampler). Liquid chromatography-tandem mass spectrometry on standard serum specimens obtained by venipuncture yielded total cortisol levels of 26.2 ± 11.6 µg·dl (women and men), and total testosterone levels of 37 ± 17 ng·dl in women and 564 ± 171 ng·dl in men. Analytical measurement ranges of the microspecimen assay were 0.3-440 µg·dl (CV <9%) for cortisol and 15 to 20,000 ng·dl (CV <9%) for testosterone. Deming regression and Pearson correlation indicated good test accuracy for the microspecimen tests compared with venipuncture tests for cortisol (y = 0.98x + 1.34, 95% CI of slope = 0.83-1.14; r = 0.92, p < 0.0001) and testosterone (y = 1.06x - 0.01, 95% CI of slope = 0.99-1.14; r = 0.99, p < 0.0001). Similarly, high agreement was observed between finger stick and venous microspecimens for cortisol (y = 1.00x + 0.65, 95% CI of slope = 0.9-1.11; r = 0.96, p < 0.001) and testosterone (y = 0.97x + 2.75, 95% CI of slope = 0.9-1.03; r = 0.99, p < 0.001). These findings suggest the viability of finger stick collection whole-blood microspecimens for assessment of total cortisol and testosterone in athletes.


Assuntos
Cromatografia Líquida/métodos , Hidrocortisona/sangue , Espectrometria de Massas em Tandem/métodos , Testosterona/sangue , Adolescente , Atletas , Cromatografia Líquida/normas , Feminino , Humanos , Masculino , Espectrometria de Massas em Tandem/normas , Adulto Jovem
7.
Cytotherapy ; 18(6): 729-39, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27173749

RESUMO

BACKGROUND AIMS: The use of bone marrow-derived mesenchymal stromal cells (MSCs) in cell-based therapies is currently being developed for a number of diseases. Thus far, the clinical results have been inconclusive and variable, in part because of the variety of cell isolation procedures and culture conditions used in each study. A new isolation technique that streamlines the method of concentration and demands less time and attention could provide clinical and economic advantages compared with current methodologies. In this study, we evaluated the concentrating capability of an integrated centrifuge-based technology compared with standard Ficoll isolation. METHODS: MSCs were concentrated from bone marrow aspirate using the new device and the Ficoll method. The isolation capabilities of the device and the growth characteristics, secretome production, and differentiation capacity of the derived cells were determined. RESULTS: The new MSC isolation device concentrated the bone marrow in 90 seconds and resulted in a mononuclear cell yield 10-fold higher and with a twofold increase in cell retention compared with Ficoll. The cells isolated using the device were shown to exhibit similar morphology and functional activity as assessed by growth curves and secretome production compared to the Ficoll-isolated cells. The surface marker and trilineage differentiation profile of the device-isolated cells was consistent with the known profile of MSCs. DISCUSSION: The faster time to isolation and greater cell yield of the integrated centrifuge-based technology may make this an improved approach for MSC isolation from bone marrow aspirates.


Assuntos
Células da Medula Óssea/citologia , Separação Celular/métodos , Centrifugação/métodos , Células-Tronco Mesenquimais/citologia , Medula Óssea , Diferenciação Celular/fisiologia , Proliferação de Células , Terapia Baseada em Transplante de Células e Tecidos/métodos , Ficoll , Humanos , Osteoblastos/citologia
8.
Asian Cardiovasc Thorac Ann ; 32(4): 234-243, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38343086

RESUMO

BACKGROUND: Research comparing the effectiveness of central aortic cannulation to axillary artery cannulation in repairing acute type A aortic dissection is limited and controversial. This meta-analysis aimed to compare early outcomes of central aortic cannulation versus axillary artery cannulation for surgery for acute aortic dissection type A. METHODS: A comprehensive systematic search was conducted across PubMed/MEDLINE, Scopus, and the Cochrane Central Register of Controlled Trials up to September 1, 2023. The primary endpoints were operative mortality and incidence of postoperative stroke. Secondary endpoints encompassed cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, postoperative temporary neurological dysfunction, combination of stroke and temporary neurological dysfunction, as well as the need for reexploration for bleeding, renal replacement therapy, and tracheotomy. A random-effect model was utilized to calculate the pooled effect size. RESULTS: Eleven studies met our eligibility criteria, enrolling a total of 7204 patients (2760 underwent aortic cannulation and 4444 underwent axillary cannulation). The operative mortality and incidence of postoperative stroke did not show statistical differences between the two groups, with a pooled odds ratio of 1.07 (95% confidence interval: 0.73-1.55) and 1.17 (0.95-1.42), respectively. Similarly, none of the secondary endpoints exhibited significant statistical differences between the two groups. CONCLUSIONS: Aortic cannulation can be a viable alternative to axillary artery cannulation for repair of acute aortic dissection type A, as both approaches present similar early clinical outcomes.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Artéria Axilar , Cateterismo Periférico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Aguda , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Dissecção Aórtica/mortalidade , Dissecção Aórtica/diagnóstico por imagem , Artéria Axilar/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
9.
J Investig Med ; 72(5): 465-474, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38548482

RESUMO

Early detection of Alzheimer's disease (AD) represents an unmet clinical need. Beta-amyloid (Aß) plays an important role in AD pathology, and the Aß42/40 peptide ratio is a good indicator for amyloid deposition. In addition, variants of the apolipoprotein E (APOE) gene are associated with variable AD risk. Here, we describe the development and validation of high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for plasma Aß40 and Aß42 quantitation, as well as apolipoprotein E (ApoE) proteotype determination as a surrogate for APOE genotype. Aß40 and Aß42 were simultaneously immunoprecipitated from plasma, proteolytically digested, and quantitated by LC-MS/MS. ApoE proteotype status was qualitatively assessed by targeting tryptic peptides from the ApoE2, ApoE3, and ApoE4 proteoforms. Both assays were validated according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Within-run precision was 1.8%-4.2% (Aß40), 1.9%-7.2% (Aß42), and 2.6%-8.3% (Aß42/40 ratio). Between-run precision was 3.5%-5.9% (Aß40), 3.8%-8.0% (Aß42), and 3.3%-8.7% (Aß42/40 ratio). Both Aß40 and Aß42 were linear from 10 to 2500 pg/mL. Identified ApoE proteotypes had 100% concordance with APOE genotypes. We have developed a precise, accurate, and sensitive high-throughput LC-MS/MS assay for plasma Aß40, Aß42, and proteoforms of ApoE.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Apolipoproteínas E , Espectrometria de Massas em Tandem , Peptídeos beta-Amiloides/sangue , Humanos , Apolipoproteínas E/genética , Apolipoproteínas E/sangue , Doença de Alzheimer/sangue , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/genética , Cromatografia Líquida , Medição de Risco , Reprodutibilidade dos Testes , Feminino , Masculino , Fragmentos de Peptídeos/sangue , Idoso , Espectrometria de Massa com Cromatografia Líquida
10.
Front Neurol ; 15: 1364658, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38595851

RESUMO

Introduction: Plasma Aß42/40 ratio can help predict amyloid PET status, but its clinical utility in Alzheimer's disease (AD) assessment is unclear. Methods: Aß42/40 ratio was measured by LC-MS/MS for 250 specimens with associated amyloid PET imaging, diagnosis, and demographic data, and for 6,192 consecutive clinical specimens submitted for Aß42/40 testing. Results: High diagnostic sensitivity and negative predictive value (NPV) for Aß-PET positivity were observed, consistent with the clinical performance of other plasma LC-MS/MS assays, but with greater separation between Aß42/40 values for individuals with positive vs. negative Aß-PET results. Assuming a moderate prevalence of Aß-PET positivity, a cutpoint was identified with 99% NPV, which could help predict that AD is likely not the cause of patients' cognitive impairment and help reduce PET evaluation by about 40%. Conclusion: High-throughput plasma Aß42/40 LC-MS/MS assays can help identify patients with low likelihood of AD pathology, which can reduce PET evaluations, allowing for cost savings.

11.
J Invasive Cardiol ; 36(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38422528

RESUMO

OBJECTIVES: To assess the impact of concomitant mitral stenosis (MS) on early and late outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS: This study involved 952 patients undergoing TAVR for severe tricuspid aortic stenosis. The patients were classified into 3 groups: without MS, with progressive MS, and severe MS (mitral valve area ≤ 1.5 cm2). Clinical outcomes between these groups were compared. RESULTS: The median age of the overall cohort was 82 years, and patients in the progressive (n = 49) and severe (n = 24) MS groups were more likely to be female than those in the no-MS group (n = 879). Periprocedural mortality rate was lowest in the no-MS group (1.8%) compared with the progressive (4.1%) and severe (4.2%) MS groups, which were not significantly different (P = .20). During 5 years of follow-up (median: 27, range: 0-72 months), there was no significant difference in all-cause mortality (log-rank P = .99), a composite of all-cause mortality or rehospitalization for heart failure (log-rank P = .84), or cardiovascular death (log-rank P = .57) between groups. Although crude analysis showed a significant difference in rehospitalization for heart failure in the severe MS group compared with the no-MS group (P = .049), the difference was not significant in the multivariate analysis (adjusted hazard ratio: 1.36 [95% CI, 0.66-2.80], P = .41). CONCLUSIONS: TAVR can be safely performed in patients with severe tricuspid aortic stenosis and concomitant MS, with early and mid-term outcomes comparable to those in patients without MS.


Assuntos
Estenose da Valva Aórtica , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/complicações , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Seguimentos , Índice de Gravidade de Doença , Resultado do Tratamento , Idoso , Taxa de Sobrevida/tendências , Fatores de Tempo , Fatores de Risco , Complicações Pós-Operatórias/epidemiologia
12.
Am J Cardiol ; 221: 9-18, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636627

RESUMO

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Pontuação de Propensão , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Idoso , Ecocardiografia
13.
Coron Artery Dis ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38739467

RESUMO

OBJECTIVE: To investigate the impact of prior coronary artery bypass grafting (CABG) and coronary lesion complexity on transcatheter aortic valve replacement (TAVR) outcomes for aortic stenosis. METHODS: Clinical outcomes of TAVR were retrospectively compared between patients with and without prior CABG, and between patients with prior CABG and without coronary artery disease (CAD). The impact of the CABG SYNTAX score was also evaluated in patients with prior CABG. RESULTS: The study included 1042 patients with a median age and follow-up of 82 years and 25 (range: 0-72) months, respectively. Of these, 175 patients had a history of CABG, while 401 were free of CAD. Patients with prior CABG were more likely to be male and had higher rates of diabetes, peripheral artery disease and atrial fibrillation compared with patients without prior CABG. After 2 : 1 propensity score matching, all-cause mortality (P = 0.17) and the composite of all-cause mortality, stroke and coronary intervention (P = 0.16) were similar between patients with (n = 166) and without (n = 304) prior CABG. A 1 : 1 propensity score-matched analysis, however, showed lower rates of all-cause mortality (P = 0.04) and the composite outcome (P = 0.04) in patients with prior CABG (n = 134) compared with patients without CAD (n = 134). The median CABG SYNTAX score was 16 (interquartile range: 9.0-23), which was not associated with better/worse clinical outcomes in patients with prior CABG. CONCLUSION: Prior CABG may positively affect mid-term TAVR outcomes for aortic stenosis compared with no CAD when adjusted for other comorbidities. The CABG SYNTAX score did not influence the prognosis after TAVR.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38719630

RESUMO

BACKGROUND/PURPOSE: To evaluate the impact of coronary artery disease (CAD), percutaneous coronary intervention (PCI), and coronary lesion complexity on outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS/MATERIALS: This retrospective study included 1042 patients divided into two groups by the presence or absence of CAD (SYNTAX score 0, no history of revascularization). Propensity score matching was used to compare the two groups. The effect of PCI, SYNTAX score, and residual SYNTAX score was also analyzed. RESULTS: The median age of the cohort was 82 years, and 641 patients had CAD. After propensity score matching, 346 pairs were analyzed. During 5 years of follow-up (median: 25, range 0-72 months), the rate of coronary intervention was significantly higher in CAD patients (p = 0.018). However, all-cause mortality, composite of all-cause mortality, stroke, and coronary intervention, and overt bleeding defined by VARC-3 were comparable. After stratification, in patients with creatinine ≥1.5 mg/dl, CAD was associated with a worse composite outcome (p = 0.016). Neither PCI nor SYNTAX score was associated with all-cause mortality in CAD patients. Similarly, residual SYNTAX score showed no association with mortality in patients undergoing PCI (all p values >0.7). PCI did not reach a significant difference in overt bleeding in CAD patients (adjusted p = 0.06). CONCLUSIONS: Despite a higher incidence of coronary interventions, major clinical outcomes were similar between patients with and without CAD after TAVR. In patients with chronic kidney disease, CAD may be associated with an adverse composite outcome. Neither PCI nor SYNTAX/residual SYNTAX score influenced all-cause mortality.

15.
medRxiv ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38168329

RESUMO

INTRODUCTION: Plasma Aß42/40 ratio can be used to help predict amyloid PET status, but its clinical utility in Alzheimer's disease (AD) assessment is unclear. METHODS: Aß42/40 ratio was measured by LC-MS/MS in 250 specimens with associated amyloid PET imaging, diagnosis, and demographic data, and 6,192 consecutive clinical specimens submitted for Aß42/40 testing. RESULTS: High diagnostic sensitivity and negative predictive value (NPV) for Aß-PET positivity were observed, consistent with the clinical performance of other plasma LC-MS/MS assays, but with greater separation between Aß42/40 values for individuals with positive vs negative Aß-PET results. Assuming a moderate prevalence of Aß-PET positivity, a cutpoint was identified with 99% NPV, which could help predict that AD is likely not the cause of patients' cognitive impairment and help reduce PET evaluation by about 40%. DISCUSSION: Using high-throughput plasma Aß42/40 LC-MS/MS assays can help reduce PET evaluations in patients with low likelihood of AD pathology, allowing for cost savings.

16.
J Cardiothorac Vasc Anesth ; 24(5): 780-4, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20650657

RESUMO

OBJECTIVE: To determine if lengths of stay in intensive care and the hospital are associated with extubation in the operating room at the conclusion of cardiac surgery. DESIGN: A nonrandomized, observational study with propensity score-guided case-control matching of prospectively collected data. SETTING: Three interrelated, university-affiliated, community hospitals. PARTICIPANTS: Three thousand three hundred seventeen patients undergoing elective or urgent coronary artery, valve repair or replacement, or combined surgery between 2000 and 2006. INTERVENTIONS: Tracheal extubation occurred, based on history and intraoperative events, either immediately in the operating room or in the intensive care unit. MEASUREMENTS AND MAIN RESULTS: Of 3,317 patients in the institutions' Society of Thoracic Surgeons database, 3,089 were extubated within 24 hours, 69% of them in the operating room. Only 0.6% of patients extubated in the operating room required reintubation, compared with 5.9% extubated in the intensive care unit (p < 0.0001). By logistic regression, 12 of 25 preoperative and intraoperative factors generated a propensity score for each of the 2,595 patients with complete data, representing the likelihood of immediate extubation (c-statistic = 0.727). A "greedy 5 to 1" propensity score-matching technique created 713 matched pairs of patients by extubation pathway. Those undergoing immediate extubation had reductions in intensive care duration by 23 hours on average (median from 46 to 27 hours, p < 0.0001) and in hospital length of stay by 0.8 days on average (median = 6 for each, p < 0.0001). Cox regression, using matched pairs as strata, identified the following independent predictors of length of stay in the intensive care unit and hospital: immediate extubation in the operating room, need for reintubation, postoperative renal failure, and postoperative atrial fibrillation. CONCLUSIONS: Selection of patients for immediate extubation in the operating room by experienced clinicians was associated with shorter ICU and hospital stays. Immediate extubation rarely resulted in tracheal re-intubation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cuidados Críticos/métodos , Remoção de Dispositivo/métodos , Tempo de Internação , Salas Cirúrgicas/métodos , Cuidados Pós-Operatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Casos e Controles , Estudos de Coortes , Cuidados Críticos/tendências , Remoção de Dispositivo/tendências , Feminino , Humanos , Intubação Intratraqueal/métodos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas/tendências , Cuidados Pós-Operatórios/tendências , Estudos Prospectivos , Fatores de Tempo
17.
Innovations (Phila) ; 14(6): 519-530, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31496371

RESUMO

Objective: Our study investigates the incidence, cumulative incidence, natural history, and factors associated with intraoperative paravalvular leak (PVL) and the development of a postoperative PVL in a contemporary consecutive cohort of patients following surgical aortic valve replacement. Methods: A total of 636 patients underwent surgical aortic valve replacement from 2006 to 2016; 410 (64.5%) underwent minimally invasive aortic valve replacement and 226 (35.5%) underwent conventional aortic valve replacement. Primary outcomes were the incidence of intraoperative PVL and cumulative incidence of postoperative PVL. Secondary outcomes were the incidence of in-hospital and long-term death and need for reoperation. Results: The overall incidence of intraoperative PVL was 1.4% (95% confidence interval [CI]: 1% to 3%). All intraoperative PVLs developed in the hand-tied group. The overall incidence of postoperative PVL was 5.3% (95% CI: 4% to 7%). In the univariable and multivariable analyses, postoperative renal failure was the only factor significantly associated with the development of a postoperative PVL. Conclusions: The incidence of intraoperative PVL is low. Cumulative incidence of postoperative PVL was 3.1% (95% CI: 1.0% to 13.6%), 4.3% (95% CI: 1.3% to 16.5%), and 5.0% (95% CI: 1.4% to 17.9%) at 1, 3, and 5 years, respectively. All intraoperative PVLs occurred with hand-tied knots. A larger cohort may identify additional risk factors.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Ecocardiografia Transesofagiana/normas , Feminino , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco
18.
Eur J Cardiothorac Surg ; 55(6): 1174-1179, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649235

RESUMO

OBJECTIVES: Patients with patent internal thoracic artery (ITA) grafts after prior coronary artery bypass grafting surgery who require aortic valve replacement (AVR) pose unique technical challenges for safe and optimal myocardial protection. The purpose of this study is to review our short- and long-term outcomes with redo minimally invasive AVR in patients with patent in situ ITA grafts. METHODS: From 2008 to 2016, 48 patients with at least 1 patent in situ mammary artery graft underwent minimally invasive AVR. Preoperative computed tomography was performed in all patients to evaluate the relationship of patent grafts to the sternum. Retrograde coronary sinus and pulmonary vent catheters were placed via the right internal jugular vein. The in situ ITA grafts were not clamped during AVR. Transverse aortotomy, taking care to avoid the grafts arising from the aorta, was performed to expose the aortic valve. RESULTS: The median age of the patients was 78 years [Quartile 1 (Q1)-Quartile 3 (Q3): 71-81]. Thirty-nine (81%) patients were men, and 46 (96%) patients had aortic stenosis. The median cardiopulmonary bypass and cross-clamp times were 124 (Q1-Q3: 108-164) and 92 (Q1-Q3: 83-116) min, respectively. Moderate hypothermia at 28-30°C was used in all patients. Most patients received cold blood cardioplegia with antegrade induction and continuous retrograde delivery. Four patients received only retrograde delivery due to some degree of aortic insufficiency. Thirty-day mortality was 4% (2 of 48 patients). There was no conversion to full sternotomy, and no reoperations were performed for postoperative bleeding or sternal wound infection. Excluding the 2 patients who died in the hospital, the median postoperative length of stay was 7 days (Q1-Q3: 5-8). Overall survival at 1, 5 and 10 years was 94%, 87% and 44%, respectively. CONCLUSIONS: Percutaneous retrograde cardioplegia combined with antegrade cardioplegia and moderate hypothermia, without interruption of ITA flow, is a safe and reliable strategy in patients with patent ITA grafts undergoing aortic valve replacement. This strategy combined with a minimally invasive approach may reduce surgical trauma, and is a safe and effective technique in these challenging patients.


Assuntos
Valva Aórtica/cirurgia , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Artéria Torácica Interna/transplante , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Esternotomia/métodos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Reoperação , Estudos Retrospectivos , Federação Russa/epidemiologia , Taxa de Sobrevida/tendências , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
J Biomater Appl ; 33(8): 1070-1079, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30651054

RESUMO

Extracellular matrix materials mechanically dissociated into submillimeter particles have a larger surface area than sheet materials and enhanced cellular attachment. Decellularized porcine mesothelial extracellular matrix microparticles were seeded with bone marrow-derived mesenchymal stromal cells and cultured in a rotating bioreactor. The mesenchymal stromal cells attached and grew to confluency on the microparticles. The cell-seeded microparticles were then encapsulated in varying concentrations of fibrin glue, and the cells migrated rapidly off the microparticles. The combination of microparticles and mesenchymal stromal cells was then applied to a splinted full-thickness cutaneous in vivo wound model. There was evidence of increased cell infiltration and collagen deposition in mesenchymal stromal cells-treated wounds. Cell-seeded microparticles have potential as a cell delivery and paracrine therapy in impaired healing environments.


Assuntos
Matriz Extracelular/química , Transplante de Células-Tronco Mesenquimais , Pele/lesões , Alicerces Teciduais/química , Cicatrização , Adulto , Animais , Adesão Celular , Movimento Celular , Células Cultivadas , Matriz Extracelular/ultraestrutura , Fibrina/química , Humanos , Células-Tronco Mesenquimais/citologia , Camundongos , Pele/ultraestrutura
20.
J Biomed Mater Res B Appl Biomater ; 106(2): 716-725, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28323397

RESUMO

Biological surgical scaffolds are used in plastic and reconstructive surgery to support structural reinforcement and regeneration of soft tissue defects. Macrophage and fibroblast cell populations heavily regulate scaffold integration into host tissue following implantation. In the present study, the biological host response to a commercially available surgical scaffold (Meso BioMatrix Surgical Mesh (MBM)) was investigated for up to 9 weeks after subcutaneous implantation; this scaffold promoted superior cell migration and infiltration previously in in vitro studies relative to other commercially available scaffolds. Infiltrating macrophages and fibroblasts phenotypes were assessed for evidence of inflammation and remodeling. At week 1, macrophages were the dominant cell population, but fibroblasts were most abundant at subsequent time points. At week 4, the scaffold supported inflammation modulation as indicated by M1 to M2 macrophage polarization; the foreign body giant cell response resolved by week 9. Unexpectedly, a fibroblast subpopulation expressed macrophage phenotypic markers, following a similar trend in transitioning from a proinflammatory to anti-inflammatory phenotype. Also, α-smooth muscle actin-expressing myofibroblasts were abundant at weeks 4 and 9, mirroring collagen expression and remodeling activity. MBM supported physiologic responses observed during normal wound healing, including cellular infiltration, host tissue ingrowth, remodeling of matrix proteins, and immune modulation. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 716-725, 2018.


Assuntos
Epitélio/química , Teste de Materiais , Telas Cirúrgicas , Alicerces Teciduais/química , Cicatrização , Animais , Feminino , Fibroblastos/metabolismo , Reação a Corpo Estranho/metabolismo , Células Gigantes de Corpo Estranho/metabolismo , Macrófagos/metabolismo , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA