Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 115(49): 12501-12506, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30420506

RESUMO

Clearance of intrapulmonary mucus by the high-velocity airflow generated by cough is the major rescue clearance mechanism in subjects with mucoobstructive diseases and failed cilial-dependent mucus clearance, e.g., subjects with cystic fibrosis (CF) or chronic obstructive pulmonary disease (COPD). Previous studies have investigated the mechanical forces generated at airway surfaces by cough but have not considered the effects of mucus biophysical properties on cough efficacy. Theoretically, mucus can be cleared by cough from the lung by an adhesive failure, i.e., breaking mucus-cell surface adhesive bonds and/or by cohesive failure, i.e., directly fracturing mucus. Utilizing peel-testing technologies, mucus-epithelial surface adhesive and mucus cohesive strengths were measured. Because both mucus concentration and pH have been reported to alter mucus biophysical properties in disease, the effects of mucus concentration and pH on adhesion and cohesion were compared. Both adhesive and cohesive strengths depended on mucus concentration, but neither on physiologically relevant changes in pH nor bicarbonate concentration. Mucus from bronchial epithelial cultures and patient sputum samples exhibited similar adhesive and cohesive properties. Notably, the magnitudes of both adhesive and cohesive strength exhibited similar velocity and concentration dependencies, suggesting that viscous dissipation of energy within mucus during cough determines the efficiency of cough clearance of diseased, hyperconcentrated, mucus. Calculations of airflow-induced shear forces on airway mucus related to mucus concentration predicted substantially reduced cough clearance in small versus large airways. Studies designed to improve cough clearance in subjects with mucoobstructive diseases identified reductions of mucus concentration and viscous dissipation as key therapeutic strategies.


Assuntos
Tosse/patologia , Muco/fisiologia , Bicarbonatos , Adesão Celular , Fibrose Cística , Células Epiteliais , Humanos , Concentração de Íons de Hidrogênio , Pneumopatias , Depuração Mucociliar/fisiologia , Muco/química , Fenômenos Fisiológicos Respiratórios , Reologia , Escarro
2.
Sci Adv ; 8(13): eabm9718, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35363522

RESUMO

Cystic fibrosis (CF) is characterized by abnormal transepithelial ion transport. However, a description of CF lung disease pathophysiology unifying superficial epithelial and submucosal gland (SMG) dysfunctions has remained elusive. We hypothesized that biophysical abnormalities associated with CF mucus hyperconcentration provide a unifying mechanism. Studies of the anion secretion-inhibited pig airway model of CF revealed elevated SMG mucus concentrations, osmotic pressures, and SMG mucus accumulation. Human airway studies revealed hyperconcentrated CF SMG mucus with raised osmotic pressures and cohesive forces predicted to limit SMG mucus secretion/release. Using proline-rich protein 4 (PRR4) as a biomarker of SMG secretion, CF sputum proteomics analyses revealed markedly lower PRR4 levels compared to healthy and bronchiectasis controls, consistent with a failure of CF SMGs to secrete mucus onto airway surfaces. Raised mucus osmotic/cohesive forces, reflecting mucus hyperconcentration, provide a unifying mechanism that describes disease-initiating mucus accumulation on airway surfaces and in SMGs of the CF lung.


Assuntos
Fibrose Cística , Animais , Fibrose Cística/metabolismo , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Muco/metabolismo , Sistema Respiratório/metabolismo , Escarro/metabolismo , Suínos
3.
Bio Protoc ; 9(13)2019 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-31687423

RESUMO

In health, the high-speed airflow associated with cough represents a vital backup mechanism for clearing accumulated mucus from our airways. However, alterations in the mucus layer in cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD) leads to the mucus layer adhered to the airway surfaces, representing the nidus of chronic lung infection. To understand what is different about diseased mucus and why cough clearance is defective, there is a need for techniques to quantify the strength of the interactions limiting the ability of airflow to strip mucus from the airway surface (i.e., adhesive strength) or tear mucus apart (i.e., cohesive strength). To overcome the issues with measuring these properties in a soft (i.e., low elastic modulus) mucus layer, we present here novel peel-testing technologies capable of quantifying the mucus adhesive strength on cultured airway cells and cohesive strength of excised mucus samples. While this protocol focuses on measurements of airway mucus, this approach can easily be adapted to measuring adhesive/cohesive properties of other soft biological materials.

4.
Sci Rep ; 7(1): 7459, 2017 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-28785072

RESUMO

In the past 5 years, e-cigarette use has been increasing rapidly, particularly in youth and young adults. Due to the novelty of e-cigarettes (e-cigs) and e-cigarette liquids (e-liquids), research on their chemo-physical properties is still in its infancy. Here, we describe a previously unknown and potentially useful property of e-liquids, namely their autofluorescence. We performed an emission scan at 9 excitation wavelengths common to fluorescent microscopy and found (i) that autofluorescence differs widely between e-liquids, (ii) that e-liquids are most fluorescent in the UV range (between 350 and 405 nm) and (iii) fluorescence intensity wanes as the emission wavelength increases. Furthermore, we used the autofluorescence of e-liquids as a marker for tracking e-cig aerosol deposition in the laboratory. Using linear regression analysis, we were able to quantify the deposition of a "vaped" e-liquid onto hard surfaces. Using this technique, we found that every 70 mL puff of an e-cigarette deposited 0.019% e-liquid (v/v) in a controlled environment. Finally, we vaped a surface in the laboratory and used our method to detect e-cig aerosol third-hand exposure. In conclusion, our data suggest that e-cigarette autofluorescence can be used as a marker of e-cigarette deposition.


Assuntos
Aerossóis/análise , Poluição por Fumaça de Tabaco/análise , Vaping/efeitos adversos , Sistemas Eletrônicos de Liberação de Nicotina , Humanos , Modelos Lineares , Microscopia de Fluorescência
5.
IEEE J Biomed Health Inform ; 20(5): 1251-1264, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27249840

RESUMO

We present our efforts toward enabling a wearable sensor system that allows for the correlation of individual environmental exposures with physiologic and subsequent adverse health responses. This system will permit a better understanding of the impact of increased ozone levels and other pollutants on chronic asthma conditions. We discuss the inefficiency of existing commercial off-the-shelf components to achieve continuous monitoring and our system-level and nano-enabled efforts toward improving the wearability and power consumption. Our system consists of a wristband, a chest patch, and a handheld spirometer. We describe our preliminary efforts to achieve a submilliwatt system ultimately powered by the energy harvested from thermal radiation and motion of the body with the primary contributions being an ultralow-power ozone sensor, an volatile organic compounds sensor, spirometer, and the integration of these and other sensors in a multimodal sensing platform. The measured environmental parameters include ambient ozone concentration, temperature, and relative humidity. Our array of sensors also assesses heart rate via photoplethysmography and electrocardiography, respiratory rate via photoplethysmography, skin impedance, three-axis acceleration, wheezing via a microphone, and expiratory airflow. The sensors on the wristband, chest patch, and spirometer consume 0.83, 0.96, and 0.01 mW, respectively. The data from each sensor are continually streamed to a peripheral data aggregation device and are subsequently transferred to a dedicated server for cloud storage. Future work includes reducing the power consumption of the system-on-chip including radio to reduce the entirety of each described system in the submilliwatt range.


Assuntos
Asma/diagnóstico , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Doença Crônica , Impedância Elétrica , Eletrocardiografia , Desenho de Equipamento , Humanos , Fotopletismografia , Pele/fisiopatologia , Espirometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA