1.
MAGMA ; 37(2): 257-272, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366129

RESUMO

OBJECTIVE: To compensate subject-specific field inhomogeneities and enhance fat pre-saturation with a fast online individual spectral-spatial (SPSP) single-channel pulse design. METHODS: The RF shape is calculated online using subject-specific field maps and a predefined excitation k-space trajectory. Calculation acceleration options are explored to increase clinical viability. Four optimization configurations are compared to a standard Gaussian spectral selective pre-saturation pulse and to a Dixon acquisition using phantom and volunteer (N = 5) data at 1.5 T with a turbo spin echo (TSE) sequence. Measurements and simulations are conducted across various body parts and image orientations. RESULTS: Phantom measurements demonstrate up to a 3.5-fold reduction in residual fat signal compared to Gaussian fat saturation. In vivo evaluations show improvements up to sixfold for dorsal subcutaneous fat in sagittal cervical spine acquisitions. The versatility of the tailored trajectory is confirmed through sagittal foot/ankle, coronal, and transversal cervical spine experiments. Additional measurements indicate that excitation field (B1) information can be disregarded at 1.5 T. Acceleration methods reduce computation time to a few seconds. DISCUSSION: An individual pulse design that primarily compensates for main field (B0) inhomogeneities in fat pre-saturation is successfully implemented within an online "push-button" workflow. Both fat saturation homogeneity and the level of suppression are improved.


Assuntos
Aumento da Imagem , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Frequência Cardíaca , Vértebras Cervicais/diagnóstico por imagem
2.
Magn Reson Med ; 89(1): 77-94, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36128895

RESUMO

PURPOSE: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. METHODS: "Universal" kT -points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. RESULTS: With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3° vs. 53.4° with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. CONCLUSION: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial.


Assuntos
Imageamento por Ressonância Magnética , Água , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Meios de Contraste , Lipídeos , Algoritmos
3.
Radiology ; 293(2): 384-393, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31573398

RESUMO

Background Commercial low-field-strength MRI systems are generally not equipped with state-of-the-art MRI hardware, and are not suitable for demanding imaging techniques. An MRI system was developed that combines low field strength (0.55 T) with high-performance imaging technology. Purpose To evaluate applications of a high-performance low-field-strength MRI system, specifically MRI-guided cardiovascular catheterizations with metallic devices, diagnostic imaging in high-susceptibility regions, and efficient image acquisition strategies. Materials and Methods A commercial 1.5-T MRI system was modified to operate at 0.55 T while maintaining high-performance hardware, shielded gradients (45 mT/m; 200 T/m/sec), and advanced imaging methods. MRI was performed between January 2018 and April 2019. T1, T2, and T2* were measured at 0.55 T; relaxivity of exogenous contrast agents was measured; and clinical applications advantageous at low field were evaluated. Results There were 83 0.55-T MRI examinations performed in study participants (45 women; mean age, 34 years ± 13). On average, T1 was 32% shorter, T2 was 26% longer, and T2* was 40% longer at 0.55 T compared with 1.5 T. Nine metallic interventional devices were found to be intrinsically safe at 0.55 T (<1°C heating) and MRI-guided right heart catheterization was performed in seven study participants with commercial metallic guidewires. Compared with 1.5 T, reduced image distortion was shown in lungs, upper airway, cranial sinuses, and intestines because of improved field homogeneity. Oxygen inhalation generated lung signal enhancement of 19% ± 11 (standard deviation) at 0.55 T compared with 7.6% ± 6.3 at 1.5 T (P = .02; five participants) because of the increased T1 relaxivity of oxygen (4.7e-4 mmHg-1sec-1). Efficient spiral image acquisitions were amenable to low field strength and generated increased signal-to-noise ratio compared with Cartesian acquisitions (P < .02). Representative imaging of the brain, spine, abdomen, and heart generated good image quality with this system. Conclusion This initial study suggests that high-performance low-field-strength MRI offers advantages for MRI-guided catheterizations with metal devices, MRI in high-susceptibility regions, and efficient imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Grist in this issue.


Assuntos
Cateterismo , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Adulto , Artefatos , Cateterismo Cardíaco/instrumentação , Meios de Contraste , Desenho de Equipamento , Feminino , Humanos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Metais , Razão Sinal-Ruído
4.
Eur Radiol ; 27(12): 5104-5112, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28698944

RESUMO

OBJECTIVES: Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time. METHODS: Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). RESULTS: Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. CONCLUSION: There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. KEY POINTS: • SEMAC is not superior to TSE in terms of artefact reduction. • MSVAT-SPACE reduces susceptibility artefacts while maintaining comparable image quality. • PETRA reduces susceptibility artefacts depending on material but offers poor image quality.


Assuntos
Artefatos , Materiais Dentários , Prótese Dentária Fixada por Implante , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Metais , Meios de Contraste , Humanos , Razão Sinal-Ruído , Zircônio
5.
Radiol Med ; 122(3): 194-203, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27896570

RESUMO

OBJECTIVE: Purpose of our study was to demonstrate the feasibility and limitations of acoustic noise reduction in a standard clinical MRI protocol for abdominal imaging. METHODS: Acoustic noise and image quality were assessed in 17 patients for a standard liver imaging protocol including TSE and GRE sequences and compared to quiet optimizations as described by Heismann et al. Two blinded readers scored artifacts, the delineation of the abdominal organs and level of diagnostic confidence. Means of the sound level measurements, the ratings and the measurement of SNR and CNR were compared. RESULTS: Significant reduction of acoustic noise was measured for T2 TSE (-30.7%), T2 HASTE (-22.6%) and less difference for T1 DIXON (-4.7%) and T1 FLASH (-2.7%). SNR and CNR were lower for quiet T2 TSE (-18.0%, -23.1%) and T2 HASTE (-46.2%, -37.7%) and higher for T1 DIXON (+32.0%, +24.4%). Inter-rater correlation was k = 0.987 with p < 0.001. CONCLUSIONS: Although sequence-based noise optimizations faces problems in T1 FLASH and DIXON sequences, there is an important acoustic benefit in T2 TSE and T2 HASTE sequences, which goes along with a maintained image quality and diagnostic confidence.


Assuntos
Abdome/diagnóstico por imagem , Artefatos , Percepção Sonora , Imageamento por Ressonância Magnética/métodos , Ruído/prevenção & controle , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade
6.
Magn Reson Med ; 75(1): 295-301, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25684192

RESUMO

PURPOSE: To quantify the accuracy of three-dimensional (3D) radial arterial spin labeled (ASL) magnetic resonance angiography (MRA) using vascular models of carotid stenosis. METHODS: Eight vascular models were imaged at 1.5 Tesla using pulsatile flow waveforms at rates found in the internal carotid arteries (100-400 mL/min). The impacts of the 3D ASL imaging readout (fast low angle shot (FLASH) versus balanced steady-state free precession (bSSFP)), ultrashort echo time imaging using a pointwise encoding time reduction with radial acquisition (PETRA), and model stenosis severity on the accuracy of vascular model display at the location of stenosis were quantified. Accuracy was computed vis-à-vis a reference bSSFP volume acquired under no flow. Comparisons were made with standard-of-care contrast-enhanced MRA (CEMRA) and Cartesian time-of-flight (TOF) MRA protocols. RESULTS: For 50% and 70% stenoses, CEMRA was most accurate (respective accuracies of 81.7% and 78.6%), followed by ASL FLASH (75.7% and 71.8%), ASL PETRA (69.6% and 70.6%), 3D TOF (66.6% and 57.1%), ASL bSSFP (68.7% and 51.2%), and 2D TOF (65.1% and 50.6%). CONCLUSION: Flow phantom imaging studies show that ASL MRA can improve the display of hemodynamically significant carotid arterial stenosis compared with TOF MRA, with FLASH and ultrashort echo time readouts being most accurate.


Assuntos
Artérias Carótidas/anatomia & histologia , Artérias Carótidas/fisiologia , Circulação Cerebrovascular/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
7.
J Magn Reson Imaging ; 44(5): 1238-1243, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26969852

RESUMO

PURPOSE: To compare the quality and diagnostic value of routine single-shot, echo-planar imaging, diffusion-weighted imaging (ss-EPI-DWI) to those of quiet readout segmented EPI-DWI (q-DWI) in magnetic resonance imaging (MRI) of acute stroke. MATERIALS AND METHODS: Twenty-six patients with acute stroke underwent a 1.5T MRI including diffusion-weighted ss-EPI and q-DWI. The two sequences were protocolled to have identical spatial resolution and spatial coverage. q-DWI was tested with (regular q-DWI) and without (fast q-DWI) averaging in 13 patients each. The acoustic noise generated by each sequence was measured. Quantitative and qualitative assessments regarding signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), lesion conspicuity, level of artifacts, overall image quality as well as diagnostic content were performed. RESULTS: SNR and CNR values of the q-DWI scans were considerably higher than those of ss-EPI DWI (P ≤ 0.0078). No statistical difference was found for lesion conspicuity (P ≥ 0.125). Statistical differences were found for level of artifacts (P ≥ 0.0078) and overall image quality (P ≥ 0.002). Both were evaluated better in the ss-EPI DWI than in the regular and fast q-DWI. Apart from one fast q-DWI patient, radiologists voted the images to have the same diagnostic content, with upper 90% confidence limits of 0.238 for regular q-DWI and 0.429 for fast q-DWI. CONCLUSION: If the acoustic burden is critical to the patient, q-DWI is an equivalent quiet alternative to ss-EPI DWI for use in stroke patients. J. Magn. Reson. Imaging 2016;44:1238-1243.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ruído/prevenção & controle , Processamento de Sinais Assistido por Computador , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Fator de Transcrição STAT1 , Sensibilidade e Especificidade
8.
J Magn Reson Imaging ; 44(2): 393-400, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26854879

RESUMO

PURPOSE: Panoramical radiographs or cone-beam computed tomography (CT) are the standard-of-care in dental imaging to assess teeth, mandible, and mandibular canal pathologies, but do not allow assessment of the inferior alveolar nerve itself nor of its branches. We propose a new technique for "MR neurographic orthopantomograms" exploiting ultrashort echo-time (UTE) imaging of bone and teeth complemented with high-resolution morphological and functional MR neurography. MATERIALS AND METHODS: The Institutional Review Board approved the study in 10 healthy volunteers. Imaging of the subjects mandibles at 3.0T (Magnetom Skyra, Siemens-Healthcare) using a 64-channel head coil with isotropic spatial resolution for subsequent multiplanar reformatting, was performed. Bone images were acquired using a 3D PETRA sequence (TE, 0.07 msec). Morphological nerve imaging was performed using a dedicated 3D PSIF and 3D SPACE STIR sequence. Functional MR neurography was accomplished using a new accelerated diffusion-tensor-imaging (DTI) prototype sequence (2D SMS-accelerated RESOLVE). Qualitative and quantitative image analysis was performed and descriptive statistics are provided. RESULTS: Image acquisition and subsequent postprocessing into the MR neurographic orthopantomogram by overlay of morphological and functional images were feasible in all 10 volunteers without artifacts. All mandibular bones and mandibular nerves were assessable and considered normal. Fiber tractography with quantitative evaluation of physiological diffusion properties of mandibular nerves yielded the following mean ± SD values: fractional anisotropy, 0.43 ± 0.07; mean diffusivity (mm(2) /s), 0.0014 ± 0.0002; axial diffusivity, 0.0020 ± 0.0002, and radial diffusivity, 0.0011 ± 0.0001. CONCLUSION: The proposed technique of MR neurographic orthopantomogram exploiting UTE imaging complemented with high-resolution morphological and functional MR neurography was feasible and allowed comprehensive assessment of osseous texture and neural microarchitecture in a single examination. J. Magn. Reson. Imaging 2016;44:393-400.


Assuntos
Imageamento por Ressonância Magnética/métodos , Mandíbula/diagnóstico por imagem , Mandíbula/inervação , Neuroimagem/métodos , Radiografia Panorâmica/métodos , Dente/diagnóstico por imagem , Dente/inervação , Adulto , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
9.
MAGMA ; 29(1): 5-15, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26490348

RESUMO

OBJECTIVE: To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. MATERIALS AND METHODS: Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. RESULTS: An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. CONCLUSIONS: The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.


Assuntos
Acústica , Imageamento por Ressonância Magnética/métodos , Ruído , Artefatos , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador , Prótons , Razão Sinal-Ruído
11.
Radiology ; 276(1): 258-65, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25768672

RESUMO

PURPOSE: To assess lung magnetic resonance (MR) imaging with a respiratory-gated pointwise encoding time reduction with radial acquisition (PETRA) sequence at 1.5 T and compare it with imaging with a standard volumetric interpolated breath-hold examination (VIBE) sequence, with extra focus on the visibility of bronchi and the signal intensity of lung parenchyma. MATERIALS AND METHODS: The study was approved by the local ethics committee, and all subjects gave written informed consent. Twelve healthy volunteers were imaged with PETRA and VIBE sequences. Image quality was evaluated by using visual scoring, numbering of visible bronchi, and quantitative measurement of the apparent contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). For preliminary clinical assessment, three young patients with cystic fibrosis underwent both MR imaging and computed tomography (CT). Comparisons were made by using the Wilcoxon signed-rank test for means and the McNemar test for ratios. Agreement between CT and MR imaging disease scores was assessed by using the κ test. RESULTS: PETRA imaging was performed with a voxel size of 0.86 mm(3). Overall image quality was good, with little motion artifact. Bronchi were visible consistently up to the fourth generation and in some cases up to the sixth generation. Mean CNR and SNR with PETRA were 32.4% ± 7.6 (standard deviation) and 322.2% ± 37.9, respectively, higher than those with VIBE (P < .001). Good agreement was found between CT and PETRA cystic fibrosis scores (κ = 1.0). CONCLUSION: PETRA enables silent, free-breathing, isotropic, and submillimeter imaging of the bronchi and lung parenchyma with high CNR and SNR and may be an alternative to CT for patients with cystic fibrosis.


Assuntos
Fibrose Cística/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória , Adulto , Brônquios/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino
12.
Magn Reson Med ; 73(3): 1104-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24889327

RESUMO

PURPOSE: Clinical MRI patients typically experience elevated acoustic noise levels of 80-110 dB(A). In this study, standard clinical turbo spin echo (TSE) and gradient echo (GRE) sequences were optimized for reduced acoustic noise at preserved diagnostic image quality. METHODS: The physical sources of acoustic noise generation in an MRI gradient coil were analyzed. A sequence conversion algorithm was derived that optimized the gradient time scheme for an arbitrary MRI sequence, preserving the governing spin physics. The algorithm was applied to generate "quiet" versions of standard clinical TSE and GRE sequences. RESULTS: The first volunteer images indicated that contrast-to-noise ratio and perceived diagnostic image quality remained on the same level for the algorithmic optimization. Additional careful TSE- and GRE-specific protocol adaptions yielded total acoustic noise reductions of up to 14.4 dB(A) for the TSE and up to 16.8 dB(A) for the GRE. CONCLUSION: A physical sound pressure reduction of 81% (TSE) and 86% (GRE) for MRI patients was achieved. The results can be used to render MRI scans more patient-friendly in clinical practice, particularly for patients who are young, scared, or elderly.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Ruído/prevenção & controle , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Satisfação do Paciente , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Magn Reson Med ; 73(5): 1939-45, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24957402

RESUMO

PURPOSE: Both CT and MR angiography are accurate for the evaluation of luminal abnormalities in peripheral arterial disease (PAD). However, only CT (requiring exposure to potentially hazardous ionizing radiation) provides a reliable means to detect vascular calcifications. In this study, we demonstrate the feasibility of detecting peripheral arterial calcifications with MRI. METHODS: The institutional investigational review board approved the study. Seven patients with PAD and iliofemoral arterial calcifications shown by prior CT angiography (CTA) were studied. The imaging techniques included: 1) dual-echo three-dimensional (3D) gradient recalled echo (GRE) pulse sequence using flow compensation and in-phase echo times (TE); and 2) prototype version of 3D point-wise encoding time reduction with radial acquisition (PETRA), which enables imaging with an ultra-short TE. RESULTS: With both techniques after grayscale inversion, vascular calcifications appeared bright, as did cortical bone, and were readily distinguished from the vessel lumen and surrounding soft tissues. The location and conformation of the calcifications corresponded with CT. The second echo GRE provided the highest contrast-to-noise ratios; whereas PETRA was best suited for the creation of thick projection images. CONCLUSION: In this pilot study, MRI was able to detect vascular calcifications. Projection imaging using PETRA provided a similar appearance to, and allowed direct comparison with, CT.


Assuntos
Calcinose/diagnóstico , Imagem Ecoplanar/métodos , Artéria Femoral/patologia , Artéria Ilíaca/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico , Idoso , Angiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
14.
J Magn Reson Imaging ; 41(2): 447-53, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24578275

RESUMO

PURPOSE: To compare the lesion contrast and signal to noise ratio (SNR) obtained with T1-weighted pointwise encoding time reduction with radial acquisition (PETRA) to those of Magnetization-Prepared RApid Gradient-Echo (MPRAGE) for contrast-enhanced imaging of primary and metastatic intracranial tumors, and to investigate whether PETRA is able to reduce acoustic noise for improved patient comfort. MATERIALS AND METHODS: Fifteen patients with intracranial tumors underwent 3 Tesla MRI including inversion-prepared PETRA and MPRAGE. The two sequences had comparable scan times, spatial resolution and spatial coverage. "Tumor conspicuity" was rated qualitatively by two radiologists, while enhancing lesion-to-white matter contrast to noise ratio (CNR) and white-matter SNR were analyzed quantitatively using paired t-tests. The acoustic noise generated by each sequence was measured. RESULTS: Qualitative rating of "tumor conspicuity" by two radiologists resulted in nearly identical average scores for the two sequences. Quantitative analyses revealed that (i) there was no significant difference between the mean CNR values of the two sequences (P = 0.57), (ii) the mean SNR of PETRA was significantly higher than that of MPRAGE (P < 0.01), and (iii) the mean sound level of PETRA was significantly lower than that of MPRAGE (P < 0.01). CONCLUSION: Inversion-prepared PETRA was found to be viable as a quiet alternative to MPRAGE for contrast-enhanced T1-weighted studies of intracranial tumors.


Assuntos
Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
15.
MAGMA ; 28(6): 511-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26092411

RESUMO

OBJECTIVE: This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. MATERIALS AND METHODS: A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. RESULTS: An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. CONCLUSIONS: The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.


Assuntos
Acústica , Imagem de Difusão por Ressonância Magnética/métodos , Ruído , Percepção Auditiva , Mapeamento Encefálico/métodos , Imagem Ecoplanar/métodos , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos
16.
Invest Radiol ; 58(1): 76-87, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36165841

RESUMO

ABSTRACT: Magnetic resonance imaging (MRI) provides essential information for diagnosing and treating musculoskeletal disorders. Although most musculoskeletal MRI examinations are performed at 1.5 and 3.0 T, modern low-field MRI systems offer new opportunities for affordable MRI worldwide. In 2021, a 0.55 T modern low-field, whole-body MRI system with an 80-cm-wide bore was introduced for clinical use in the United States and Europe. Compared with current higher-field-strength MRI systems, the 0.55 T MRI system has a lower total ownership cost, including purchase price, installation, and maintenance. Although signal-to-noise ratios scale with field strength, modern signal transmission and receiver chains improve signal yield compared with older low-field magnetic resonance scanner generations. Advanced radiofrequency coils permit short echo spacing and overall compacter echo trains than previously possible. Deep learning-based advanced image reconstruction algorithms provide substantial improvements in perceived signal-to-noise ratios, contrast, and spatial resolution. Musculoskeletal tissue contrast evolutions behave differently at 0.55 T, which requires careful consideration when designing pulse sequences. Similar to other field strengths, parallel imaging and simultaneous multislice acquisition techniques are vital for efficient musculoskeletal MRI acquisitions. Pliable receiver coils with a more cost-effective design offer a path to more affordable surface coils and improve image quality. Whereas fat suppression is inherently more challenging at lower field strengths, chemical shift selective fat suppression is reliable and homogeneous with modern low-field MRI technology. Dixon-based gradient echo pulse sequences provide efficient and reliable multicontrast options, including postcontrast MRI. Metal artifact reduction MRI benefits substantially from the lower field strength, including slice encoding for metal artifact correction for effective metal artifact reduction of high-susceptibility metallic implants. Wide-bore scanner designs offer exciting opportunities for interventional MRI. This review provides an overview of the economical aspects, signal and image quality considerations, technological components and coils, musculoskeletal tissue relaxation times, and image contrast of modern low-field MRI and discusses the mainstream and new applications, challenges, and opportunities of musculoskeletal MRI.


Assuntos
Artefatos , Sistema Musculoesquelético , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Sistema Musculoesquelético/diagnóstico por imagem
17.
Invest Radiol ; 58(2): 121-125, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070538

RESUMO

OBJECTIVES: Intracranial aneurysm (IA) is the main cause of subarachnoid hemorrhages. Time-of-flight (TOF) magnetic resonance angiography (MRA) at 1.5 T or 3 T magnetic resonance imaging (MRI) is a well-established method for the diagnosis of IA. The aim of this prospective study was to evaluate the performance of a modern 0.55 T MRI in the diagnosis of IAs in comparison to digital subtraction angiography (DSA) as a standard of reference. MATERIALS AND METHODS: Seventeen patients with suspicion of single or multiple IAs underwent TOF MRA at 0.55 T MRI 1 day before DSA. Two neuroradiologists independently measured the aneurysm neck, width, and height on 0.55 T, 1.5 T, and 3 T 3D-TOF MRA source images and 2D/3D rotational angiography. The main analysis assessed the intermodality agreement between 0.55 T TOF MRA and DSA using Bland-Altman plots, a Wilcoxon test, and the intraclass correlation coefficient (ICC). In a secondary analysis, aneurysm dimensions were compared between 0.55 T TOF MRA and 1.5/3 T TOF MRA. Interreader agreement was evaluated by ICC. A third neuroradiologist blinded to patient history screened 0.55 T TOF MRA data sets of the aforementioned 17 patients and 15 additional healthy patients for the presence and location of aneurysms. RESULTS: A total of 19 aneurysms in 16 patients were identified in both 0.55 T MRA and DSA. Measurements of the 2 nonblinded readers showed no significant differences between 0.55 T TOF MRA and DSA in the overall aneurysm size (calculated as the mean from height/width/neck) ( P = 0.178), as well as in the mean width ( P = 0.778) and neck values ( P = 0.190). The mean height was significantly larger in 0.55 T TOF MRA in comparison to DSA ( P = 0.020). Intermodality (1.5/3 T TOF MRA) and interrater agreement were excellent (ICC > 0.94). Of the 32 data sets of patients with and without IA, the blinded reader detected all aneurysms correctly by using 0.55 T images. CONCLUSIONS: TOF-MRA acquired with a modern 0.55 T MRI is a reliable tool for the detection and initial assessment of IAs.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética , Angiografia por Ressonância Magnética/métodos , Angiografia Digital/métodos
18.
Magn Reson Med ; 67(2): 510-8, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21721039

RESUMO

Sequences with ultrashort echo times enable new applications of MRI, including bone, tendon, ligament, and dental imaging. In this article, a sequence is presented that achieves the shortest possible encoding time for each k-space point, limited by pulse length, hardware switching times, and gradient performance of the scanner. In pointwise encoding time reduction with radial acquisition (PETRA), outer k-space is filled with radial half-projections, whereas the centre is measured single pointwise on a Cartesian trajectory. This hybrid sequence combines the features of single point imaging with radial projection imaging. No hardware changes are required. Using this method, 3D images with an isotropic resolution of 1 mm can be obtained in less than 3 minutes. The differences between PETRA and the ultrashort echo time (UTE) sequence are evaluated by simulation and phantom measurements. Advantages of pointwise encoding time reduction with radial acquisition are shown for tissue with a T(2) below 1 ms. The signal to noise ratio and Contrast-to-noise ratio (CNR) performance, as well as possible limitations of the approach, are investigated. In-vivo head, knee, ankle, and wrist examples are presented to prove the feasibility of the sequence. In summary, fast imaging with ultrashort echo time is enabled by PETRA and may help to establish new routine clinical applications of ultrashort echo time sequences.


Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Osso e Ossos/anatomia & histologia , Análise de Fourier , Cabeça/anatomia & histologia , Humanos , Ligamentos/anatomia & histologia , Imagens de Fantasmas , Sensibilidade e Especificidade , Tendões/anatomia & histologia , Fatores de Tempo
19.
Invest Radiol ; 57(11): 742-751, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35640012

RESUMO

OBJECTIVES: With the COVID-19 pandemic, repetitive lung examinations have become necessary to follow-up symptoms and associated alterations. Low-field MRI, benefiting from reduced susceptibility effects, is a promising alternative for lung imaging to limit radiations absorbed by patients during CT examinations, which also have limited capability to assess functional alterations. The aim of this investigative study was to explore the functional abnormalities that free-breathing 0.55 T MRI in combination with the phase-resolved functional lung (PREFUL) analysis could identify in patients with persistent symptoms after COVID-19 infection. MATERIALS AND METHODS: Seventy-four COVID-19 patients and 8 healthy volunteers were prospectively scanned in free-breathing with a balanced steady-state free-precession sequence optimized at 0.55 T, 5 months postinfection on average. Normalized perfusion (Q), fractional ventilation (FV), and flow-volume loop correlation (FVLc) maps were extracted with the PREFUL technique. Q, FV, and FVLc defects as well as defect overlaps between these metrics were quantified. Morphological turbo-spin-echo images were also acquired, and the extent of abnormalities was scored by a board-certified radiologist. To investigate the functional correlates of persistent symptoms, a recursive feature elimination algorithm was applied to find the most informative variables to detect the presence of persistent symptoms with a logistic regression model and a cross-validation strategy. All MRI metrics, sex, age, body mass index, and the presence of preexisting lung conditions were included. RESULTS: The most informative variables to detect persistent symptoms were the percentage of concurrent Q and FVLc defects and of areas free of those defects. A detection accuracy of 71.4% was obtained with these 2 variables when fitting the model on the entire dataset. Although none of the single variables differed between patients with and without persistent symptoms ( P > 0.05), the combined score of these 2 variables did ( P < 0.02). This score also showed a consistent increase from healthy volunteers (7.7) to patients without persistent symptoms (8.2) and with persistent symptoms (8.6). The morphological abnormality score showed poor correlation with the functional parameters. CONCLUSIONS: Functional pulmonary examinations using free-breathing 0.55 T MRI with PREFUL analysis revealed potential quantitative markers of impaired lung function in patients with persistent symptoms after COVID-19 infection, potentially complementing morphologic imaging. Future work is needed to explore the translational relevance and clinical implication of these findings.


Assuntos
COVID-19 , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pandemias , Respiração