Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circulation ; 125(24): 2985-92, 2012 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-22626743

RESUMO

BACKGROUND: Heart failure patients with implantable cardioverter-defibrillators (ICDs) or an ICD for resynchronization therapy often visit the hospital for unscheduled examinations, placing a great burden on healthcare providers. We hypothesized that Internet-based remote interrogation systems could reduce emergency healthcare visits. METHODS AND RESULTS: This multicenter randomized trial involving 200 patients compared remote monitoring with standard patient management consisting of scheduled visits and patient response to audible ICD alerts. The primary end point was the rate of emergency department or urgent in-office visits for heart failure, arrhythmias, or ICD-related events. Over 16 months, such visits were 35% less frequent in the remote arm (75 versus 117; incidence density, 0.59 versus 0.93 events per year; P=0.005). A 21% difference was observed in the rates of total healthcare visits for heart failure, arrhythmias, or ICD-related events (4.40 versus 5.74 events per year; P<0.001). The time from an ICD alert condition to review of the data was reduced from 24.8 days in the standard arm to 1.4 days in the remote arm (P<0.001). The patients' clinical status, as measured by the Clinical Composite Score, was similar in the 2 groups, whereas a more favorable change in quality of life (Minnesota Living With Heart Failure Questionnaire) was observed from the baseline to the 16th month in the remote arm (P=0.026). CONCLUSIONS: Remote monitoring reduces emergency department/urgent in-office visits and, in general, total healthcare use in patients with ICD or defibrillators for resynchronization therapy. Compared with standard follow-up through in-office visits and audible ICD alerts, remote monitoring results in increased efficiency for healthcare providers and improved quality of care for patients. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00873899.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Internet , Qualidade da Assistência à Saúde , Idoso , Feminino , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Qualidade de Vida , Consulta Remota
2.
J Med Internet Res ; 15(5): e106, 2013 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-23722666

RESUMO

BACKGROUND: Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. OBJECTIVE: We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. METHODS: Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. RESULTS: Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. CONCLUSIONS: Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. TRIAL REGISTRATION: ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).


Assuntos
Análise Custo-Benefício , Desfibriladores Implantáveis , Insuficiência Cardíaca/cirurgia , Monitorização Fisiológica/métodos , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/fisiopatologia , Humanos , Monitorização Fisiológica/economia
3.
J Interv Card Electrophysiol ; 24(1): 53-61, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18975066

RESUMO

PURPOSE: The aim of the present study is to evaluate if remote monitoring with the CareLink Network may improve clinical management of tachyarrhythmias and heart failure episodes in patients treated with biventricular defibrillators (CRT-D). METHODS: Patients implanted with CRT-D for more than 6 months received the CareLink monitor and were trained to perform device interrogation. At-home transmissions were scheduled at 2 weeks, 1 and 2 months after training, with a final in-office visit after 3 months. RESULTS: Sixty-seven patients performed 264 data transmissions. Twenty-three unscheduled data transmissions were requested by the centers after patient contact. Ventricular tachyarrhythmias were reported in nine patients during 16 data reviews. Thirteen data reviews (81%) were performed remotely via CareLink transmissions (nine scheduled and four unscheduled), in seven patients. Of these events, in two cases (15%) in-hospital visits were requested, while in 11 (85%) no action was needed and no additional in-clinic visits were scheduled. During the study period, in 20/28 (71%) intra-thoracic impedance alerts, the patients remotely transmitted their device data. After remote data review, in ten cases drug therapy was adjusted by phone and in four cases no action was needed and the patient reassured. In six episodes an in-hospital extra visit was scheduled. On the whole, in 14 cases (70%), the patient could be managed remotely avoiding a visit to the hospital. CONCLUSIONS: Our study showed that remote follow-up is an efficient method to manage tachyarrhythmias and heart failure episodes in CRT-D patients. Early reaction to clinical events may improve overall patient care.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Telemedicina/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 31(10): 1259-64, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18811805

RESUMO

PURPOSE: The Medtronic CareLink allows remote implantable device follow-up. In this first European experience with CareLink, we assessed the ease of use of the system, the acceptance, and satisfaction of patients and clinicians. METHODS: Patients implanted with biventricular defibrillators for more than 6 months received the CareLink monitor and were trained to perform home device interrogation and transmission. Patient and clinician experience and preference were evaluated through specific questionnaires. RESULTS: Sixty-seven patients were enrolled and were able to perform data transmissions during the 3-month study duration. The overall duration of interrogation procedure was 7 +/- 5 minutes, and frequently the procedure did not require the assistance of a caregiver. Patients reported a general preference for remote versus in-clinic follow-up and described a sense of reassurance created by the remote monitoring capability.In the centers, the review procedure was successful; its mean duration was 5 +/- 2 minutes per transmission and the users indicated that the access and navigation of the review website were easy. At the end of the evaluation, the data available for remote review were judged complete and adequate to provide almost the same standard of care as that offered in traditional in-clinic visit. In general, the remote monitoring was seen as a potential tool to improve the clinical management of patients with device. CONCLUSIONS: The ease of use, satisfaction, and acceptance of the CareLink Network in European clinical practice appears elevated both for patients and for clinicians.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Consulta Remota/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade
5.
Trials ; 10: 42, 2009 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-19538734

RESUMO

BACKGROUND: Heart failure patients with implantable defibrillators (ICD) frequently visit the clinic for routine device monitoring. Moreover, in the case of clinical events, such as ICD shocks or alert notifications for changes in cardiac status or safety issues, they often visit the emergency department or the clinic for an unscheduled visit. These planned and unplanned visits place a great burden on healthcare providers. Internet-based remote device interrogation systems, which give physicians remote access to patients' data, are being proposed in order to reduce routine and interim visits and to detect and notify alert conditions earlier. METHODS: The EVOLVO study is a prospective, randomized, parallel, unblinded, multicenter clinical trial designed to compare remote ICD management with the current standard of care, in order to assess its ability to treat and triage patients more effectively. Two-hundred patients implanted with wireless-transmission-enabled ICD will be enrolled and randomized to receive either the Medtronic CareLink monitor for remote transmission or the conventional method of in-person evaluations. The purpose of this manuscript is to describe the design of the trial. The results, which are to be presented separately, will characterize healthcare utilizations as a result of ICD follow-up by means of remote monitoring instead of conventional in-person evaluations. TRIAL REGISTRATION: ClinicalTrials.gov: NCT00873899.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Consulta Remota/métodos , Triagem/métodos , Seguimentos , Humanos , Internet , Consulta Remota/normas , Projetos de Pesquisa , Tamanho da Amostra , Triagem/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA