Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 310(1): e230981, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38193833

RESUMO

Background Multiple commercial artificial intelligence (AI) products exist for assessing radiographs; however, comparable performance data for these algorithms are limited. Purpose To perform an independent, stand-alone validation of commercially available AI products for bone age prediction based on hand radiographs and lung nodule detection on chest radiographs. Materials and Methods This retrospective study was carried out as part of Project AIR. Nine of 17 eligible AI products were validated on data from seven Dutch hospitals. For bone age prediction, the root mean square error (RMSE) and Pearson correlation coefficient were computed. The reference standard was set by three to five expert readers. For lung nodule detection, the area under the receiver operating characteristic curve (AUC) was computed. The reference standard was set by a chest radiologist based on CT. Randomized subsets of hand (n = 95) and chest (n = 140) radiographs were read by 14 and 17 human readers, respectively, with varying experience. Results Two bone age prediction algorithms were tested on hand radiographs (from January 2017 to January 2022) in 326 patients (mean age, 10 years ± 4 [SD]; 173 female patients) and correlated strongly with the reference standard (r = 0.99; P < .001 for both). No difference in RMSE was observed between algorithms (0.63 years [95% CI: 0.58, 0.69] and 0.57 years [95% CI: 0.52, 0.61]) and readers (0.68 years [95% CI: 0.64, 0.73]). Seven lung nodule detection algorithms were validated on chest radiographs (from January 2012 to May 2022) in 386 patients (mean age, 64 years ± 11; 223 male patients). Compared with readers (mean AUC, 0.81 [95% CI: 0.77, 0.85]), four algorithms performed better (AUC range, 0.86-0.93; P value range, <.001 to .04). Conclusions Compared with human readers, four AI algorithms for detecting lung nodules on chest radiographs showed improved performance, whereas the remaining algorithms tested showed no evidence of a difference in performance. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Omoumi and Richiardi in this issue.


Assuntos
Inteligência Artificial , Software , Humanos , Feminino , Masculino , Criança , Pessoa de Meia-Idade , Estudos Retrospectivos , Algoritmos , Pulmão
2.
Acta Radiol ; : 2841851241240446, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630492

RESUMO

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel imaging technique that increases the applicability of CT for cardiac imaging; however, the scanning requires a substantial radiation dose. PURPOSE: To investigate the feasibility of dose reduction in dynamic CTP by comparing all-heartbeat acquisitions to periodic skipping of heartbeats. MATERIAL AND METHODS: We retrieved imaging data of 38 dynamic CTP patients and created new datasets with every fourth, third or second beat (Skip1:4, Skip1:3, Skip1:2, respectively) removed. Seven observers evaluated the resulting images and perfusion maps for perfusion deficits. The mean blood flow (MBF) in each of the 16 myocardial segments was compared per skipped-beat level, normalized by the respective MBF for the full dose, and averaged across patients. The number of segments/cases whose MBF was <1.0 mL/g/min were counted. RESULTS: Out of 608 segments in 38 cases, the total additional number of false-negative (FN) segments over those present in the full-dose acquisitions and the number of additional false-positive cases were shown as acquisition (segment [%], case): Skip1:4: 7 (1.2%, 1); Skip1:3: 12 (2%, 3), and Skip1:2: 5 (0.8%, 2). The variability in quantitative MBF analysis in the repeated analysis for the reference condition resulted in 8 (1.3%) additional FN segments. The normalized results show a comparable MBF across all segments and patients, with relative mean MBFs as 1.02 ± 0.16, 1.03 ± 0.25, and 1.06 ± 0.30 for the Skip1:4, Skip1:3, and Skip1:2 protocols, respectively. CONCLUSION: Skipping every second beat acquisition during dynamic myocardial CTP appears feasible and may result in a radiation dose reduction of 50%. Diagnostic performance does not decrease after removing 50% of time points in dynamic sequence.

3.
Eur Radiol ; 33(8): 5509-5525, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36997751

RESUMO

In patients with suspected coronary artery disease (CAD), dynamic myocardial computed tomography perfusion (CTP) imaging combined with coronary CT angiography (CTA) has become a comprehensive diagnostic examination technique resulting in both anatomical and quantitative functional information on myocardial blood flow, and the presence and grading of stenosis. Recently, CTP imaging has been proven to have good diagnostic accuracy for detecting myocardial ischemia, comparable to stress magnetic resonance imaging and positron emission tomography perfusion, while being superior to single photon emission computed tomography. Dynamic CTP accompanied by coronary CTA can serve as a gatekeeper for invasive workup, as it reduces unnecessary diagnostic invasive coronary angiography. Dynamic CTP also has good prognostic value for the prediction of major adverse cardiovascular events. In this article, we will provide an overview of dynamic CTP, including the basics of coronary blood flow physiology, applications and technical aspects including protocols, image acquisition and reconstruction, future perspectives, and scientific challenges. KEY POINTS: • Stress dynamic myocardial CT perfusion combined with coronary CTA is a comprehensive diagnostic examination technique resulting in both anatomical and quantitative functional information. • Dynamic CTP imaging has good diagnostic accuracy for detecting myocardial ischemia comparable to stress MRI and PET perfusion. • Dynamic CTP accompanied by coronary CTA may serve as a gatekeeper for invasive workup and can guide treatment in obstructive coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Valor Preditivo dos Testes , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Isquemia Miocárdica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Imagem de Perfusão do Miocárdio/métodos
4.
Acta Radiol ; 64(3): 999-1006, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35765201

RESUMO

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel technique able to depict cardiac ischemia. PURPOSE: To evaluate the impact of a four-dimensional noise reduction filter (similarity filter [4D-SF]) on image quality in dynamic CTP imaging, allowing for substantial radiation dose reduction. MATERIAL AND METHODS: Dynamic CTP datasets of 30 patients (16 women) with suspected coronary artery disease, acquired with a 320-slice CT system, were retrieved, reconstructed with the deep learning-based algorithm of the system (DLR), and filtered with the 4D-SF. For each case, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in six regions of interest (33-38mm2) were calculated before and after filtering, in four-chamber and short-axis views, and t-tested. Furthermore, six radiologists of different expertise evaluated subjective image preference by answering five visual grading analysis-type questions (regarding acceptable level of noise, absence of artifacts, natural appearance, cardiac contour sharpness, diagnostic acceptability) using a 5-point scale. The results were analyzed using visual grade characteristics (VGC) and intraclass correlation coefficient (ICC). RESULTS: Mean SNR in four-chamber view (unfiltered vs. filtered) were: septum=4.1 ± 2.1 versus 7.6 ± 5.6; lateral wall=4.5 ± 2.0 versus 8.0 ± 4.9; CNRseptum=16.6 ± 8.9 versus 31.7 ± 28; lateral wall=16.2 ± 8.9 versus 31.3 ± 28.9. Similar results were obtained in short-axis view. The perceived filtered image quality indicated decreased noise (VGCAUC=0.96) and artifacts (0.65), improved natural appearance (0.59), cardiac contour sharpness (0.74), and diagnostic acceptability (0.78). The inter-observer variability was excellent (ICC=0.79). All results were statistically significant (P < 0.05). CONCLUSION: Similarity filtering after DLR improves image quality, possibly enabling dose reduction in dynamic CTP imaging in patient with suspected chronic coronary syndrome.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Imagem de Perfusão do Miocárdio/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Miocárdio , Coração/diagnóstico por imagem , Razão Sinal-Ruído , Algoritmos , Tomografia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação
5.
Pediatr Cardiol ; 44(1): 75-85, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35727332

RESUMO

With the trend towards childhood surgery in patients with Ebstein anomaly (EA), thorough imaging is crucial for patient selection. This study aimed to assess biventricular function by echocardiography and cardiac magnetic resonance (CMR) and compare EA severity classifications. Twenty-three patients (8-17 years) underwent echocardiography and CMR. Echocardiographic parameters included tricuspid annular plane systolic excursions (TAPSE), fractional area change of the functional right ventricle (fRV-FAC), fRV free wall peak systolic myocardial velocity (fRVs'), and tricuspid regurgitation (TR). End-diastolic and end-systolic volume (EDV resp. ESV), fRV- and LV ejection fraction (EF) and TR were obtained by CMR. EA severity classifications included displacement index, Celermajer index and the total-right/left-volume index. Median fRV-FAC was 38% (IQR 33-42). TAPSE and fRVs' were reduced in 39% and 75% of the patients, respectively. Echocardiographic TR was visually graded as mild, moderate, or severe in nine, six and eight patients, respectively. By CMR, median fRVEF was 49% (IQR 36-58) and TR was graded as mild, moderate, or severe in nine, twelve and two patients, respectively. In 70% of cases, fRV-EDV was higher than LV-EDV. LVEF was decreased in 17 cases (74%). There was excellent correlation between echocardiography-derived fRV-FAC and CMR-derived fRVEF (rho = 0.812, p < 0.001). While echocardiography is a versatile tool in the complex geometry of the Ebstein heart, it has limitations. CMR offers a total overview and has the advantage of reliable volume assessment of both ventricles. Comprehensive evaluation of pediatric patients with EA may therefore require a synergistic implementation of echocardiography and CMR.


Assuntos
Anomalia de Ebstein , Ecocardiografia , Imageamento por Ressonância Magnética , Adolescente , Criança , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Volume Sistólico
6.
MAGMA ; 31(1): 7-18, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29177772

RESUMO

OBJECTIVE: To demonstrate imaging performance for cardiac MR imaging at 7 T using a coil array of 8 transmit/receive dipole antennas and 16 receive loops. MATERIALS AND METHODS: An 8-channel dipole array was extended by adding 16 receive-only loops. Average power constraints were determined by electromagnetic simulations. Cine imaging was performed on eight healthy subjects. Geometrical factor (g-factor) maps were calculated to assess acceleration performance. Signal-to-noise ratio (SNR)-scaled images were reconstructed for different combinations of receive channels, to demonstrate the SNR benefits of combining loops and dipoles. RESULTS: The overall image quality of the cardiac functional images was rated a 2.6 on a 4-point scale by two experienced radiologists. Imaging results at different acceleration factors demonstrate that acceleration factors up to 6 could be obtained while keeping the average g-factor below 1.27. SNR maps demonstrate that combining loops and dipoles provides a more than 50% enhancement of the SNR in the heart, compared to a situation where only loops or dipoles are used. CONCLUSION: This work demonstrates the performance of a combined loop/dipole array for cardiac imaging at 7 T. With this array, acceleration factors of 6 are possible without increasing the average g-factor in the heart beyond 1.27. Combining loops and dipoles in receive mode enhances the SNR compared to receiving with loops or dipoles only.


Assuntos
Técnicas de Imagem Cardíaca/instrumentação , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Adulto , Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Simulação por Computador , Fenômenos Eletromagnéticos , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imagem Cinética por Ressonância Magnética/instrumentação , Imagem Cinética por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/estatística & dados numéricos , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído , Adulto Jovem
8.
Eur Radiol ; 27(9): 3934-3941, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28271154

RESUMO

OBJECTIVES: Relatively little is known about the incidence of long-term renal damage after renal denervation (RDN), a potential new treatment for hypertension. In this study the incidence of renal artery and parenchymal changes, assessed with contrast-enhanced magnetic resonance angiography (MRA) after RDN, is investigated. METHODS: This study is an initiative of ENCOReD, a collaboration of hypertension expert centres. Patients in whom an MRA was performed before and after RDN were included. Scans were evaluated by two independent, blinded radiologists. Primary outcome was the change in renal artery morphology and parenchyma. RESULTS: MRAs from 96 patients were analysed. Before RDN, 41 renal anomalies were observed, of which 29 mostly mild renal artery stenoses. After a median time of 366 days post RDN, MRA showed a new stenosis (25-49% lumen reduction) in two patients and progression of pre-existing lumen reduction in a single patient. No other renal changes were observed and renal function remained stable. CONCLUSIONS: We observed new or progressed renal artery stenosis in three out of 96 patients, after a median time of 12 months post RDN (3.1%). Procedural angiographies showed that ablations were applied near the observed stenosis in only one of the three patients. KEY POINTS: • The incidence of vascular changes 12 months post RDN was 3.1%. • No renal vascular or parenchymal changes other than stenoses were observed. • Ablations were applied near the stenosis in only one of three patients.


Assuntos
Obstrução da Artéria Renal/patologia , Artéria Renal/patologia , Simpatectomia/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hipertensão Renovascular/patologia , Hipertensão Renovascular/cirurgia , Rim/inervação , Rim/patologia , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Simpatectomia/métodos
9.
Eur Radiol ; 26(11): 3771-3780, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26847041

RESUMO

OBJECTIVES: To provide a comprehensive overview of all reported cardiac magnetic resonance (CMR) findings that predict clinical deterioration in pulmonary arterial hypertension (PAH). METHODS: MEDLINE and EMBASE electronic databases were systematically searched for longitudinal studies published by April 2015 that reported associations between CMR findings and adverse clinical outcome in PAH. Studies were appraised using previously developed criteria for prognostic studies. Meta-analysis using random effect models was performed for CMR findings investigated by three or more studies. RESULTS: Eight papers (539 patients) investigating 21 different CMR findings were included. Meta-analysis showed that right ventricular (RV) ejection fraction was the strongest predictor of mortality in PAH (pooled HR 1.23 [95 % CI 1.07-1.41], p = 0.003) per 5 % decrease. In addition, RV end-diastolic volume index (pooled HR 1.06 [95 % CI 1.00-1.12], p = 0.049), RV end-systolic volume index (pooled HR 1.05 [95 % CI 1.01-1.09], p = 0.013) and left ventricular end-diastolic volume index (pooled HR 1.16 [95 % CI 1.00-1.34], p = 0.045) were of prognostic importance. RV and LV mass did not provide prognostic information (p = 0.852 and p = 0.983, respectively). CONCLUSION: This meta-analysis substantiates the clinical yield of specific CMR findings in the prognostication of PAH patients. Decreased RV ejection is the strongest and most well established predictor of mortality. KEY POINTS: • Cardiac magnetic resonance imaging is useful for prognostication in pulmonary arterial hypertension. • Right ventricular ejection fraction is the strongest predictor of mortality. • Serial CMR evaluation seems to be of additional prognostic importance. • Accurate prognostication can aid in adequate and timely intensification of PAH-specific therapy.


Assuntos
Hipertensão Pulmonar/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Direita/diagnóstico , Função Ventricular Direita/fisiologia , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Prognóstico , Volume Sistólico , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
10.
Eur Radiol ; 26(4): 997-1006, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26474984

RESUMO

OBJECTIVES: Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. METHODS: Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. RESULTS: Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. CONCLUSIONS: MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. KEY POINTS: • Postoperative MDCT presents baseline morphology relevant for prosthetic valve follow-up. • 83 % of patients show periaortic induration 6 weeks after aortic valve replacement. • MDCT detected three cases of clinically relevant pathology not found with TTE. • Valve dehiscence detection by MDCT required redo valve surgery in one patient. • MDCT is a suitable and complementary imaging tool for follow-up purposes.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Falha de Prótese/efeitos adversos , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Recidiva , Padrões de Referência
11.
Eur Radiol ; 25(6): 1623-30, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25501272

RESUMO

OBJECTIVES: Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). METHODS: PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. RESULTS: Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. CONCLUSION: MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. KEY POINTS: • Retrospective MDCT is increasingly used for prosthetic heart valve dysfunction assessment • In case of PHV reoperation, invasive coronary angiography is also required • MDCT can replace CAG in 50 % of patients without coronary artery disease • When conclusive for coronary assessment, MDCT stenosis rule out is highly accurate • Replacing CAG saves associated risks of distant embolization of thrombi or vegetations.


Assuntos
Angiografia Coronária/métodos , Análise de Falha de Equipamento/métodos , Próteses Valvulares Cardíacas , Valvas Cardíacas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Reprodutibilidade dos Testes
12.
Eur Radiol ; 25(7): 2125-33, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25680715

RESUMO

OBJECTIVES: Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. METHODS: Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. RESULTS: Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100%; 82/95%, and 88/94%, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93%, 86/98%, and 100/94%, respectively. CONCLUSIONS: TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. KEY POINTS: • Multimodal imaging is an important ingredient of diagnostic workup for PHV endocarditis. • Transthoracic and transesophageal echography may miss life-threatening periannular complications. • MDCT can improve sensitivity for the detection of life-threatening periannular complications.


Assuntos
Endocardite/diagnóstico , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese/diagnóstico , Diagnóstico Diferencial , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Tomografia Computadorizada Multidetectores/métodos , Imagem Multimodal/métodos , Sensibilidade e Especificidade
13.
Eur Heart J Cardiovasc Imaging ; 25(7): 929-936, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38306632

RESUMO

AIMS: To compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: Two-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.


Assuntos
Insuficiência da Valva Aórtica , Imagem Cinética por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Feminino , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Estudos Prospectivos , Idoso de 80 Anos ou mais , Idoso , Imagem Cinética por Ressonância Magnética/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo , Complicações Pós-Operatórias/diagnóstico por imagem , Índice de Gravidade de Doença , Estudos de Coortes
14.
BMJ Open Sport Exerc Med ; 10(2): e002070, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38882206

RESUMO

Exercise can produce transient elevations of cardiac troponin (cTn) concentrations, which may resemble the cTn release profile of myocardial infarction. Consequently, clinical interpretation of postexercise cTn elevations (ie, values above the 99th percentile upper reference limit) remains challenging and may cause clinical confusion. Therefore, insight into the physiological versus pathological nature of postexercise cTn concentrations is warranted. We aim to (1) establish resting and postexercise reference values for recreational athletes engaged in walking, cycling or running exercise; (2) compare the prevalence of (sub)clinical coronary artery disease in athletes with high versus low postexercise cTn concentrations and (3) determine the association between postexercise cTn concentrations and the incidence of major adverse cardiovascular events (MACE) and mortality during long-term follow-up. For this purpose, the prospective TRoponin concentrations following Exercise and the Association with cardiovascular ouTcomes (TREAT) observational cohort study was designed to recruit 1500 recreational athletes aged ≥40 to <70 years who will participate in Dutch walking, cycling and running events. Baseline and postexercise high-sensitivity cTnT and cTnI concentrations will be determined. The prevalence and magnitude of coronary atherosclerosis on computed tomography (eg, coronary artery calcium score, plaque type, stenosis degree and CT-derived fractional flow reserve) will be compared between n=100 athletes with high postexercise cTn concentrations vs n=50 age-matched, sex-matched and sport type-matched athletes with low postexercise cTn concentrations. The incidence of MACE and mortality will be assessed in the entire cohort up to 20 years follow-up. The TREAT study will advance our understanding of the clinical significance of exercise-induced cTn elevations in middle-aged and older recreational athletes. Trial registration number NCT06295081.

15.
Eur Radiol ; 23(4): 968-74, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23064676

RESUMO

OBJECTIVES: To compare native aortic (AV) and mitral valve (MV) image quality on limited-dose retrospectively ECG-gated CTA of the thoracoabdominal aorta reconstructed with iterative reconstruction (IR) and filtered back projection (FBP). METHODS: Fifty patients underwent routine care retrospectively ECG-gated thoracoabdominal limited-dose 256-slice CTA. At 30 % (systole) and 75 % (diastole) of the R-R interval AV and MV were reconstructed using FBP and IR. Objective image quality [density and noise (SD of density measurement)] was measured. Two independent observers scored subjective valve image quality using four-point Likert scales. RESULTS: IR significantly decreased image noise, but did not alter the aorta and interventricular septum density. Interobserver variability was moderate to good. Valve image quality was scored at least moderate in most cases. IR scored one or two Likert scale points higher than FBP in 10 (first observer) and 27 (second observer) scores. Conversely, IR scored one Likert scale point lower than FBP in 1 (first observer) and 4 (second observer) scores. CONCLUSIONS: Limited-dose retrospectively ECG-gated thoracoabdominal CTA enables moderate to excellent evaluation of AV and MV in most patients, in addition to the primary diagnostic question. Image quality is further improved by IR.


Assuntos
Valva Aórtica/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Valva Mitral/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Radiografia Abdominal/métodos , Radiografia Torácica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Eur Radiol ; 23(8): 2228-35, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23591617

RESUMO

OBJECTIVE: To investigate the feasibility of subtractionless first-pass single contrast medium dose (0.1 mmol/kg) peripheral magnetic resonance angiography (MRA) at 1.5 T using two-point Dixon fat suppression and compare it with conventional subtraction MRA in terms of image quality. METHODS: Twenty-eight patients (13 male, 15 female; mean age ± standard deviation, 66 ± 16 years) with known or suspected peripheral arterial disease underwent subtractionless and subtraction first-pass MRA at 1.5 T using two-point Dixon fat suppression. Results were compared with regard to vessel-to-background contrast. A phantom study was performed to assess the signal-to-noise ratio (SNR) of both MRA techniques. Two experienced observers scored subjective image quality. Agreement regarding subjective image quality was expressed in quadratic weighted κ values. RESULTS: Vessel-to-background contrast improved in all anatomical locations with the subtractionless method versus the subtraction method (all P < 0.001). Subjective image quality was uniformly higher with the subtractionless method (all P < 0.03, except for the aorto-iliac arteries for observer 1, P = 0.052). SNR was 15 % higher with the subtractionless method (31.9 vs 27.6). CONCLUSION: This study demonstrates the feasibility of subtractionless first-pass single contrast medium dose lower extremity MRA. Moreover, both objective and subjective image quality are better than with subtraction MRA. KEY POINTS: • MRA is increasingly used for vascular applications. • Dixon imaging offers an alternative to image subtraction for fat suppression. • Subtractionless first-pass peripheral MRA is possible using two-point Dixon fat suppression. • Subtractionless peripheral MRA is possible at 1.5 T a single contrast medium dose. • Subtractionless first-pass peripheral MRA provides good image quality with few non-diagnostic studies.


Assuntos
Tecido Adiposo/patologia , Meios de Contraste , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/métodos , Criança , Meios de Contraste/farmacologia , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Razão Sinal-Ruído , Técnica de Subtração , Adulto Jovem
17.
Int J Cardiol ; 388: 131162, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37433407

RESUMO

BACKGROUND: Left ventricular (LV) strain and rotation are emerging functional markers for early detection of LV dysfunction and have been associated with the burden of myocardial fibrosis in several disease states. This study examined the association between LV deformation (i.e., LV strain and rotation) and extent and location of LV myocardial fibrosis in pediatric patients with Duchenne muscular dystrophy (DMD). METHODS AND RESULTS: 34 pediatric patients with DMD underwent cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) to assess LV myocardial fibrosis. Offline CMR feature-tracking analysis was used to assess global and segmental longitudinal and circumferential LV strain, and LV rotation. Patients with fibrosis (n = 18, 52.9%) were older than those without fibrosis (14 ± 3 years (yrs) vs 11 ± 2 yrs., p = 0.01). There was no significant difference in LV ejection fraction (LVEF) between subjects with and without fibrosis (54 ± 6% vs 56 ± 4%, p = 0.18). However, lower endocardial global circumferential strain (GCS), but not LV rotation, was associated with presence of fibrosis (adjusted Odds Ratio 1.25 [95% CI 1.01-1.56], p = 0.04). Both GCS and global longitudinal strain correlated with the extent of fibrosis (r = .52, p = 0.03 and r = .75, p < 0.01, respectively). Importantly, segmental strain did not seem to correspond to location of fibrosis. CONCLUSION: A lower global, but not segmental, strain is associated with presence and extent of LV myocardial fibrosis in pediatric DMD patients. Therefore, strain parameters might detect structural myocardial alterations, however currently more research is needed to evaluate its value (e.g., prognostic) in clinical practice.


Assuntos
Cardiomiopatias , Distrofia Muscular de Duchenne , Humanos , Criança , Meios de Contraste , Distrofia Muscular de Duchenne/complicações , Distrofia Muscular de Duchenne/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Cardiomiopatias/diagnóstico , Miocárdio/patologia , Função Ventricular Esquerda , Volume Sistólico , Fibrose
18.
Eur Heart J Cardiovasc Imaging ; 24(8): 1072-1081, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-36915984

RESUMO

AIMS: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement (TAVR) that poses an increased risk of rehospitalization for heart failure and mortality. The aim of this study was to assess the accuracy of haemodynamic indices to predict relevant PVR. METHODS AND RESULTS: In this prospective single-centre clinical trial, four haemodynamic indices of PVR measured during TAVR were assessed for their correlation with gold standard cardiac magnetic resonance (CMR)-derived regurgitant fraction (CMR-RF) at 1 month follow-up: diastolic delta (DD), heart rate-adjusted diastolic delta (HR-DD), aortic regurgitation index (ARI), and aortic regurgitation index ratio (ARI ratio). These haemodynamic indices were analysed for their ability to predict relevant PVR (defined as CMR-RF > 20%) using receiver operating characteristic (ROC) curves with corresponding area under the ROC curves (AUCs). A total of 77 patients were included and had CMR performed 41 ± 14 days after TAVR. Mean CMR-RF was 12.4 ± 9.3%. Fifteen (19.5%) patients had CMR-RF > 20%. DD had the best correlation with CMR-RF and the highest AUC to predict relevant PVR (0.82; 95% CI, 0.72-0.92), followed by HR-DD (AUC 0.78; 95% CI, 0.67-0.89), ARI (AUC 0.78; 95% CI, 0.66-0.89), and ARI ratio (AUC 0.65; 95% CI, 0.49-0.81). The optimal cut-off value for DD was 32 mmHg, with sensitivity of 69% and specificity of 77% in predicting relevant PVR. CONCLUSION: DD measured during TAVR best predicts relevant PVR. Correction for heart rate (HR-DD) or systolic blood pressure (ARI, ARI ratio) did not improve this predictive value.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Espectroscopia de Ressonância Magnética/efeitos adversos , Estudos Prospectivos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
19.
Eur Radiol ; 22(6): 1271-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22205446

RESUMO

OBJECTIVES: Multidetector computed tomography (MDCT) has diagnostic value for the evaluation of prosthetic heart valve (PHV) dysfunction but it is hampered by artefacts. We hypothesised that image acquisition using prospective triggering instead of retrospective gating would reduce artefacts related to pulsating PHV. METHODS: In a pulsatile in vitro model, a mono- and bileaflet PHV were imaged using 256 MDCT at 60, 75 and 90 beats per minute (BPM) with either retrospective gating (120 kV, 600 mAs, pitch 0.2, CTDI(vol) 39.8 mGy) or prospective triggering (120 kV, 200 mAs, CTDI(vol) 13.3 mGy). Two thresholds (>175 and <-45HU), derived from the density of surrounding structures, were used for quantification of hyper- and hypodense artefacts. Image noise and artefacts were compared between protocols. RESULTS: Prospective triggering reduced hyperdense artefacts for both valves at every BPM (P = 0.001 all comparisons). Hypodense artefacts were reduced for the monoleaflet valve at 60 (P = 0.009), 75 (P = 0.016) and 90 BPM (P = 0.001), and for the bileaflet valves at 60 (P = 0.001), 90 (P = 0.001) but not at 75 BPM (P = 0.6). Prospective triggering reduced image noise at 60 (P = 0.001) and 75 (P < 0.03) but not at 90 BPM. CONCLUSIONS: Compared with retrospective gating, prospective triggering reduced most artefacts related to pulsating PHV in vitro. KEY POINTS: • Computed tomographic images are often degraded by prosthetic heart valve-induced artefacts • Prospective triggering reduces prosthetic heart valve-induced artefacts in vitro • Artefact reduction at 90 beats per minute occurs without image noise reduction • Prospective triggering may improve CT image quality of moving hyperdense structures.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Eletrocardiografia/métodos , Próteses Valvulares Cardíacas , Valvas Cardíacas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Valvas Cardíacas/cirurgia , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
20.
Eur Radiol ; 22(6): 1278-86, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22193371

RESUMO

OBJECTIVES: Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. METHODS: ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. RESULTS: Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. CONCLUSIONS: Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. KEY POINTS: • Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment • Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts • Björk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Próteses Valvulares Cardíacas/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA