Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 715
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Intern Med ; 177(7): 919-928, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38768453

RESUMO

BACKGROUND: Computer-aided diagnosis (CADx) allows prediction of polyp histology during colonoscopy, which may reduce unnecessary removal of nonneoplastic polyps. However, the potential benefits and harms of CADx are still unclear. PURPOSE: To quantify the benefit and harm of using CADx in colonoscopy for the optical diagnosis of small (≤5-mm) rectosigmoid polyps. DATA SOURCES: Medline, Embase, and Scopus were searched for articles published before 22 December 2023. STUDY SELECTION: Histologically verified diagnostic accuracy studies that evaluated the real-time performance of physicians in predicting neoplastic change of small rectosigmoid polyps without or with CADx assistance during colonoscopy. DATA EXTRACTION: The clinical benefit and harm were estimated on the basis of accuracy values of the endoscopist before and after CADx assistance. The certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. The outcome measure for benefit was the proportion of polyps predicted to be nonneoplastic that would avoid removal with the use of CADx. The outcome measure for harm was the proportion of neoplastic polyps that would be not resected and left in situ due to an incorrect diagnosis with the use of CADx. Histology served as the reference standard for both outcomes. DATA SYNTHESIS: Ten studies, including 3620 patients with 4103 small rectosigmoid polyps, were analyzed. The studies that assessed the performance of CADx alone (9 studies; 3237 polyps) showed a sensitivity of 87.3% (95% CI, 79.2% to 92.5%) and specificity of 88.9% (CI, 81.7% to 93.5%) in predicting neoplastic change. In the studies that compared histology prediction performance before versus after CADx assistance (4 studies; 2503 polyps), there was no difference in the proportion of polyps predicted to be nonneoplastic that would avoid removal (55.4% vs. 58.4%; risk ratio [RR], 1.06 [CI, 0.96 to 1.17]; moderate-certainty evidence) or in the proportion of neoplastic polyps that would be erroneously left in situ (8.2% vs. 7.5%; RR, 0.95 [CI, 0.69 to 1.33]; moderate-certainty evidence). LIMITATION: The application of optical diagnosis was only simulated, potentially altering the decision-making process of the operator. CONCLUSION: Computer-aided diagnosis provided no incremental benefit or harm in the management of small rectosigmoid polyps during colonoscopy. PRIMARY FUNDING SOURCE: European Commission. (PROSPERO: CRD42023402197).


Assuntos
Pólipos do Colo , Colonoscopia , Diagnóstico por Computador , Humanos , Pólipos do Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico
2.
Ann Intern Med ; 177(7): 911-918, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38768450

RESUMO

BACKGROUND: Real-time prediction of histologic features of small colorectal polyps may prevent resection and/or pathologic evaluation and therefore decrease colonoscopy costs. Previous studies showed that computer-aided diagnosis (CADx) was highly accurate, though it did not outperform expert endoscopists. OBJECTIVE: To assess the diagnostic performance of histologic predictions by general endoscopists before and after assistance from CADx in a real-life setting. DESIGN: Prospective, multicenter, single-group study. (ClinicalTrials.gov: NCT04437615). SETTING: 6 centers across the United States. PARTICIPANTS: 1252 consecutive patients undergoing colonoscopy and 49 general endoscopists with variable experience in real-time prediction of polyp histologic features. INTERVENTION: Real-time use of CADx during routine colonoscopy. MEASUREMENTS: The primary end points were the sensitivity and specificity of CADx-unassisted and CADx-assisted histologic predictions for adenomas measuring 5 mm or less. For clinical purposes, additional estimates according to location and confidence level were provided. RESULTS: The CADx device made a diagnosis for 2695 polyps measuring 5 mm or less (96%) in 1252 patients. There was no difference in sensitivity between the unassisted and assisted groups (90.7% vs. 90.8%; P = 0.52). Specificity was higher in the CADx-assisted group (59.5% vs. 64.7%; P < 0.001). Among all 2695 polyps measuring 5 mm or less, 88.2% and 86.1% (P < 0.001) in the CADx-assisted and unassisted groups, respectively, could be resected and discarded without pathologic evaluation. Among 743 rectosigmoid polyps measuring 5 mm or less, 49.5% and 47.9% (P < 0.001) in the CADx-assisted and unassisted groups, respectively, could be left in situ without resection. LIMITATION: Decision making based on CADx might differ outside a clinical trial. CONCLUSION: CADx assistance did not result in increased sensitivity of optical diagnosis. Despite a slight increase, the specificity of CADx-assisted diagnosis remained suboptimal. PRIMARY FUNDING SOURCE: Olympus America Corporation served as the clinical study sponsor.


Assuntos
Inteligência Artificial , Pólipos do Colo , Colonoscopia , Diagnóstico por Computador , Sensibilidade e Especificidade , Humanos , Pólipos do Colo/patologia , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adenoma/patologia , Adenoma/diagnóstico , Neoplasias Colorretais/patologia , Competência Clínica , Adulto
3.
Gut ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38876773

RESUMO

BACKGROUND AND AIM: Randomised trials show improved polyp detection with computer-aided detection (CADe), mostly of small lesions. However, operator and selection bias may affect CADe's true benefit. Clinical outcomes of increased detection have not yet been fully elucidated. METHODS: In this multicentre trial, CADe combining convolutional and recurrent neural networks was used for polyp detection. Blinded endoscopists were monitored in real time by a second observer with CADe access. CADe detections prompted reinspection. Adenoma detection rates (ADR) and polyp detection rates were measured prestudy and poststudy. Histological assessments were done by independent histopathologists. The primary outcome compared polyp detection between endoscopists and CADe. RESULTS: In 946 patients (51.9% male, mean age 64), a total of 2141 polyps were identified, including 989 adenomas. CADe was not superior to human polyp detection (sensitivity 94.6% vs 96.0%) but outperformed them when restricted to adenomas. Unblinding led to an additional yield of 86 true positive polyp detections (1.1% ADR increase per patient; 73.8% were <5 mm). CADe also increased non-neoplastic polyp detection by an absolute value of 4.9% of the cases (1.8% increase of entire polyp load). Procedure time increased with 6.6±6.5 min (+42.6%). In 22/946 patients, the additional detection of adenomas changed surveillance intervals (2.3%), mostly by increasing the number of small adenomas beyond the cut-off. CONCLUSION: Even if CADe appears to be slightly more sensitive than human endoscopists, the additional gain in ADR was minimal and follow-up intervals rarely changed. Additional inspection of non-neoplastic lesions was increased, adding to the inspection and/or polypectomy workload.

4.
Ann Surg ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39077765

RESUMO

OBJECTIVE: To develop and externally validate an updated artificial intelligence (AI) prediction system for stratifying the risk of lymph node metastasis (LNM) in T2 colorectal cancer (CRC). SUMMARY BACKGROUND DATA: Recent technical advances allow complete local excision of T2 CRC, traditionally treated with surgical resection. Yet, the widespread adoption of this approach is hampered by the inability to stratify the risk of LNM. METHODS: Data from pT2 CRC patients undergoing surgical resection between April 2000 and May 2022 at one Japanese and one Italian center were analyzed. Primary goal was AI system development for accurate LNM prediction. Predictors encompassed seven variables: age, sex, tumor size and location, lympho-vascular invasion, histological differentiation, and carcinoembryonic antigen level. The tool's discriminating power was assessed via Area Under the Curve (AUC), sensitivity, and specificity. RESULTS: Out of 735 initial patients, 692 were eligible. Training and validation cohorts comprised of 492 and 200 patients, respectively. The AI model displayed an AUC of 0.75 in the combined validation dataset. Sensitivity for LNM prediction was 97.8% and specificity was 15.6%. The Positive and the Negative Predictive Value were 25.7% and 96% respectively. The False Negative (FN) rate was 2.2%, the False Positive was 84.4%. CONCLUSIONS: Our AI model, based on easily accessible clinical and pathological variables, moderately predicts LNM in T2 CRC. However, the risk of FN needs to be considered. The training of the model including more patients across Western and Eastern centers -differentiating between colon and rectal cancers- may improve its performance and accuracy.

5.
Artigo em Inglês | MEDLINE | ID: mdl-39142543

RESUMO

BACKGROUND AND AIMS: Limited evidence exists regarding the impact of glucagon-like peptide-1 receptor agonists (GLP-1RAs) on upper endoscopy. Therefore, a meta-analysis was conducted to comprehensively review the available evidence on this subject. METHODS: A systematic bibliographic search was carried out until May 2024. Pooled estimates were analyzed using a random-effects model, with results presented as odds ratios (OR) and 95% confidence intervals (CI). The primary outcome assessed was the rate of retained gastric content (RGC), while secondary outcomes included rates of aborted and repeated procedures, adverse event (AE) rate, and rates of aspiration. RESULTS: This analysis included 13 studies involving a total of 84,065 patients. Patients receiving GLP-1RA therapy exhibited significantly higher rates of RGC (OR 5.56, 3.35-9.23), a trend that was consistent among patients with diabetes (OR 2.60, 2.23-3.02). Adjusted analysis, accounting for variables such as sex, age, body mass index (BMI), diabetes, and other therapies, confirmed the elevated rates of RGC in the GLP-1RA user group (aOR 4.20, 3.42-5.15). Furthermore, rates of aborted and repeated procedures were higher in the GLP-1RA user group (OR 5.13, 3.01-8.75, and OR 2.19, 1.43-3.35; respectively). However, no significant differences were found in AE and aspiration rates between the two groups (OR 4.04, 0.63-26.03, and OR 1.75, 0.64-4.77; respectively). CONCLUSION: Use of GLP-1RAs is associated with increased retention of gastric contents and more frequent aborted procedures during upper endoscopy. However, the AEs and aspiration rates do not seem different, therefore adjusting fasting time instead of routinely withholding GLP-1RAs could be reasonable in these patients.

6.
Gastroenterology ; 165(1): 244-251.e3, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061169

RESUMO

BACKGROUND & AIMS: Both computer-aided detection (CADe)-assisted and Endocuff-assisted colonoscopy have been found to increase adenoma detection. We investigated the performance of the combination of the 2 tools compared with CADe-assisted colonoscopy alone to detect colorectal neoplasias during colonoscopy in a multicenter randomized trial. METHODS: Men and women undergoing colonoscopy for colorectal cancer screening, polyp surveillance, or clincial indications at 6 centers in Italy and Switzerland were enrolled. Patients were assigned (1:1) to colonoscopy with the combinations of CADe (GI-Genius; Medtronic) and a mucosal exposure device (Endocuff Vision [ECV]; Olympus) or to CADe-assisted colonoscopy alone (control group). All detected lesions were removed and sent to histopathology for diagnosis. The primary outcome was adenoma detection rate (percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, advanced adenomas and serrated lesions detection rate, the rate of unnecessary polypectomies (polyp resection without histologically proven adenomas), and withdrawal time. RESULTS: From July 1, 2021 to May 31, 2022, there were 1316 subjects randomized and eligible for analysis; 660 to the ECV group, 656 to the control group). The adenoma detection rate was significantly higher in the ECV group (49.6%) than in the control group (44.0%) (relative risk, 1.12; 95% CI, 1.00-1.26; P = .04). Adenomas detected per colonoscopy were significantly higher in the ECV group (mean ± SD, 0.94 ± 0.54) than in the control group (0.74 ± 0.21) (incidence rate ratio, 1.26; 95% CI, 1.04-1.54; P = .02). The 2 groups did not differ in term of detection of advanced adenomas and serrated lesions. There was no significant difference between groups in mean ± SD withdrawal time (9.01 ± 2.48 seconds for the ECV group vs 8.96 ± 2.24 seconds for controls; P = .69) or proportion of subjects undergoing unnecessary polypectomies (relative risk, 0.89; 95% CI, 0.69-1.14; P = .38). CONCLUSIONS: The combination of CADe and ECV during colonoscopy increases adenoma detection rate and adenomas detected per colonoscopy without increasing withdrawal time compared with CADe alone. CLINICALTRIALS: gov, Number: NCT04676308.


Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Feminino , Colonoscopia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Mucosa , Computadores
7.
Clin Gastroenterol Hepatol ; 22(7): 1518-1527.e7, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38325601

RESUMO

BACKGROUND: Post-fecal immunochemical test (FIT) colonoscopy represents a setting with an enriched prevalence of advanced adenomas. Due to an expected higher risk of colorectal cancer (CRC), postpolypectomy surveillance is recommended, generating a substantially increased load on endoscopy services. The aim of our study was to investigate postpolypectomy CRC risk in a screening population of FIT+ subjects after resection of low-risk adenomas (LRAs) or high-risk adenomas (HRAs). METHODS: We retrieved data from a cohort of patients undergoing postpolypectomy surveillance within a FIT-based CRC screening program in Italy between 2002 and 2017 and followed-up to December 2021. Main outcomes were postpolypectomy CRC incidence and mortality risks according to type of adenoma (LRA/HRA) removed at colonoscopy as well as morphology, size, dysplasia, and location of the index lesion. We adopted as comparators FIT+/colonoscopy-negative and FIT- patients. The absolute risk was calculated as the number of incident CRCs per 100,000 person-years of follow-up. We used Cox multivariable regression models to identify associations between CRC risks and patient- and polyp-related variables. RESULTS: Overall, we included 87,248 post-FIT+ colonoscopies (133 endoscopists). Of these, 42,899 (49.2%) were negative, 21,650 (24.8%) had an LRA, and 22,709 (26.0%) an HRA. After a median follow-up of 7.25 years, a total of 635 CRCs were observed. For patients with LRAs, CRC incidence (hazard ratio [HR], 1.18; 95% confidence interval [CI], 0.92-1.53) was not increased compared with the FIT+/colonoscopy-negative group, while for HRAs a significant increase in CRC incidence (HR, 1.53; 95% CI, 1.14-2.04) was found. The presence of 1 or more risk factors among proximal location, nonpedunculated morphology, and high-grade dysplasia explained most of this excess CRC risk in the HRA group (HR, 1.85; 95% CI, 1.36-2.52). Patients with only distal pedunculated polyps without high-grade dysplasia, representing 39.2% of HRA, did not have increased risk compared with the FIT- group (HR, 0.87; 95% CI, 0.59-1.28). CONCLUSIONS: CRC incidence is significantly higher in patients with HRAs diagnosed at colonoscopy. However, such excess risk does not appear to apply to patients with only distal pedunculated polyps without high-grade dysplasia, an observation that could potentially reduce the burden of surveillance in FIT programs.


Assuntos
Pólipos do Colo , Colonoscopia , Neoplasias Colorretais , Humanos , Masculino , Feminino , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Pessoa de Meia-Idade , Idoso , Itália/epidemiologia , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Pólipos do Colo/epidemiologia , Incidência , Adenoma/cirurgia , Adenoma/epidemiologia , Adenoma/patologia , Medição de Risco , Detecção Precoce de Câncer/métodos , Fatores de Risco , Estudos Retrospectivos
8.
Radiology ; 310(1): e232078, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38289210

RESUMO

Background The natural history of colorectal polyps is not well characterized due to clinical standards of care and other practical constraints limiting in vivo longitudinal surveillance. Established CT colonography (CTC) clinical screening protocols allow surveillance of small (6-9 mm) polyps. Purpose To assess the natural history of colorectal polyps followed with CTC in a clinical screening program, with histopathologic correlation for resected polyps. Materials and Methods In this retrospective study, CTC was used to longitudinally monitor small colorectal polyps in asymptomatic adult patients from April 1, 2004, to August 31, 2020. All patients underwent at least two CTC examinations. Polyp growth patterns across multiple time points were analyzed, with histopathologic context for resected polyps. Regression analysis was performed to evaluate predictors of advanced histopathology. Results In this study of 475 asymptomatic adult patients (mean age, 56.9 years ± 6.7 [SD]; 263 men), 639 unique polyps (mean initial diameter, 6.3 mm; volume, 50.2 mm3) were followed for a mean of 5.1 years ± 2.9. Of these 639 polyps, 398 (62.3%) underwent resection and histopathologic evaluation, and 41 (6.4%) proved to be histopathologically advanced (adenocarcinoma, high-grade dysplasia, or villous content), including two cancers and 38 tubulovillous adenomas. Advanced polyps showed mean volume growth of +178% per year (752% per year for adenocarcinomas) compared with +33% per year for nonadvanced polyps and -3% per year for unresected, unretrieved, or resolved polyps (P < .001). In addition, 90% of histologically advanced polyps achieved a volume of 100 mm3 and/or volume growth rate of 100% per year, compared with 29% of nonadvanced and 16% of unresected or resolved polyps (P < .001). Polyp volume-to-diameter ratio was also significantly greater for advanced polyps. For polyps observed at three or more time points, most advanced polyps demonstrated an initial slower growth interval, followed by a period of more rapid growth. Conclusion Small colorectal polyps ultimately proving to be histopathologically advanced neoplasms demonstrated substantially faster growth and attained greater overall size compared with nonadvanced polyps. Clinical trial registration no. NCT00204867 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Dachman in this issue.


Assuntos
Adenocarcinoma , Pólipos do Colo , Colonografia Tomográfica Computadorizada , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Pólipos do Colo/diagnóstico por imagem , Estudos Retrospectivos , Exame Físico
9.
Ann Hematol ; 103(1): 1-4, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37940717

RESUMO

The diagnostic work-up in iron deficiency anaemia (IDA) patients can be challenging when bleedings or malabsorption are not clinically manifest. Lesions on the small bowel mucosa may cause IDA. We evaluated the prevalence of lesions on the small bowel mucosa detected at Videocapsule Endoscopy (VCE) in IDA patients following negative upper and lower endoscopies. Clinical and endoscopic data collected in 5 centres were retrieved. Lesions with a high bleeding potential (P2) were computed, and predictive factors investigated at multivariate analysis. By considering data of 230 patients, the endoscopic examination detected a total of 96 (41.7%; 95% CI: 35.4-48.1) P2 lesions on the small bowel mucosa, including 4 (1.7%) cancers. The use of non-steroidal anti-inflammatory drugs was found to be the only associated factor at both univariate (OR: 5.7, 95% CI: 2.4-13.4; P <0.001) and multivariate (OR: 2.8; 95% CI: 1.7-3.9, P <0.01) analyses. Present study showed that evaluation of small bowel mucosa with VCE allows to disclose a potential cause of IDA in near half patients. The cooperation between haematologists and gastroenterologists in the diagnostic work-up may be useful.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/epidemiologia , Anemia Ferropriva/etiologia , Hemorragia Gastrointestinal/etiologia , Endoscopia por Cápsula/efeitos adversos , Intestino Delgado/patologia
10.
Gastrointest Endosc ; 99(3): 326-336.e6, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38065513

RESUMO

BACKGROUND AND AIMS: Despite advances in EMR techniques, a high polyp recurrence rate remains a challenge. Due to the scarcity of direct comparisons, we performed an indirect comparison of conventional EMR (EMR alone), underwater EMR (U-EMR), and EMR + adjuvant thermal ablation of polypectomy margins to assess polyp recurrence rates. METHODS: Electronic databases were searched from inception to January 12, 2023, for studies reporting polyp recurrence rates after EMR for large nonpedunculated polyps (>15 mm) with or without adjuvant techniques (snare tip soft coagulation [STSC]/argon plasma coagulation [APC]). An indirect comparison was performed by using the frequentist method. The p-score was calculated to identify preferred intervention. Publication bias was assessed by using a comparison-adjusted funnel plot. RESULTS: A total of 9 full articles were identified. On direct comparisons, EMR + STSC had 82% reduced odds (odds ratio, .18; 95% confidence interval, .13-.26; P < .001), whereas U-EMR alone had 77% reduced odds (odds ratio, .23; 95% confidence interval, .08-.67; P = .007) of polyp recurrence compared with EMR alone. On indirect comparison, all interventions had significantly lower odds of polyp recurrence compared with EMR alone. The p-score ranking showed that EMR + STSC seems a potential first method in reducing the odds of polyp recurrence, followed by U-EMR, EMR + APC, and EMR alone. CONCLUSIONS: EMR + STSC seems to provide favorable odds for reducing polyp recurrence postresection for large nonpedunculated polyps. Standardization of methods to detect residual polyp and prevent polyp recurrence at the time of EMR are required.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Ressecção Endoscópica de Mucosa/métodos , Neoplasias Colorretais/cirurgia
11.
Gastrointest Endosc ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851458

RESUMO

BACKGROUND AND AIMS: Serrated polyps (SPs) are precursors to 15% to 20% of colorectal cancers (CRCs). However, there are uncertainties regarding which SPs require surveillance and at what intervals, with recommendations adapted from those for adenomas in the absence of solid evidence. Our aim was to assess which SP risk characteristics relate to a higher risk of metachronous CRC or advanced polyps. METHODS: We systematically searched PubMed, Embase, and Cochrane for cohort studies, case-control studies, and clinical trials from inception to December 31, 2023, of CRC or advanced polyps (advanced adenoma [AA] or advanced SP) incidence at surveillance stratified by baseline SP size, dysplasia, location, and multiplicity. We defined advanced SPs as those ≥10 mm or with dysplasia. CRC and advanced polyp incidence per 1000 person-years were estimated. We performed a meta-analysis by calculating pooled relative risks (RRs) using a random-effects model. RESULTS: A total of 5903 studies were reviewed, and 14 were included with 493,949 patients (mean age, 59.5 years; 55% men). The mean follow-up was 4.9 years. CRC incidence per 1000 person-years was 2.09 (95% confidence interval [CI], 1.29-2.90) for advanced SPs, 1.52 (95% CI, 0.78-2.25) for SPs of ≥10 mm, 5.86 (95% CI, 2.16-9.56) for SPs with dysplasia, 1.18 (95% CI, 0.77-1.60) for proximal SPs, 0.52 (95% CI, 0.08-1.12) for ≥3 SPs, 0.50 (95% CI, 0.35-0.66) for nonadvanced SPs, and 0.44 (95% CI, 0.41-0.46) for normal colonoscopy findings. Metachronous CRC risk was higher in advanced SPs versus nonadvanced SPs (RR, 1.84; 95% CI, 1.11-3.04) and versus normal colonoscopy findings (RR, 2.92; 95% CI, 2.26-3.77), in SPs of ≥10 mm versus <10 mm (RR, 2.61; 95% CI, 1.43-4.77) and versus normal colonoscopy findings (RR: 3.52; 95% CI, 2.17-5.69); and in SPs with dysplasia versus normal colonoscopy findings (RR: 2.71; 95% CI, 2.00-3.67). No increase in CRC or advanced polyp risk was found in patients with proximal versus distal SPs, nor in ≥3 SPs versus 1 or 2 SPs. CONCLUSIONS: CRC risk is significantly higher in patients with baseline advanced SPs after 4.9 years of follow-up, with risk magnitudes similar to those described for AA, supporting the current recommendation for 3-year surveillance in patients with advanced SPs.

12.
Gastrointest Endosc ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38639679

RESUMO

BACKGROUND AND AIMS: The American Society for Gastrointestinal Endoscopy (ASGE) AI Task Force along with experts in endoscopy, technology space, regulatory authorities, and other medical subspecialties initiated a consensus process that analyzed the current literature, highlighted potential areas, and outlined the necessary research in artificial intelligence (AI) to allow a clearer understanding of AI as it pertains to endoscopy currently. METHODS: A modified Delphi process was used to develop these consensus statements. RESULTS: Statement 1: Current advances in AI allow for the development of AI-based algorithms that can be applied to endoscopy to augment endoscopist performance in detection and characterization of endoscopic lesions. Statement 2: Computer vision-based algorithms provide opportunities to redefine quality metrics in endoscopy using AI, which can be standardized and can reduce subjectivity in reporting quality metrics. Natural language processing-based algorithms can help with the data abstraction needed for reporting current quality metrics in GI endoscopy effortlessly. Statement 3: AI technologies can support smart endoscopy suites, which may help optimize workflows in the endoscopy suite, including automated documentation. Statement 4: Using AI and machine learning helps in predictive modeling, diagnosis, and prognostication. High-quality data with multidimensionality are needed for risk prediction, prognostication of specific clinical conditions, and their outcomes when using machine learning methods. Statement 5: Big data and cloud-based tools can help advance clinical research in gastroenterology. Multimodal data are key to understanding the maximal extent of the disease state and unlocking treatment options. Statement 6: Understanding how to evaluate AI algorithms in the gastroenterology literature and clinical trials is important for gastroenterologists, trainees, and researchers, and hence education efforts by GI societies are needed. Statement 7: Several challenges regarding integrating AI solutions into the clinical practice of endoscopy exist, including understanding the role of human-AI interaction. Transparency, interpretability, and explainability of AI algorithms play a key role in their clinical adoption in GI endoscopy. Developing appropriate AI governance, data procurement, and tools needed for the AI lifecycle are critical for the successful implementation of AI into clinical practice. Statement 8: For payment of AI in endoscopy, a thorough evaluation of the potential value proposition for AI systems may help guide purchasing decisions in endoscopy. Reliable cost-effectiveness studies to guide reimbursement are needed. Statement 9: Relevant clinical outcomes and performance metrics for AI in gastroenterology are currently not well defined. To improve the quality and interpretability of research in the field, steps need to be taken to define these evidence standards. Statement 10: A balanced view of AI technologies and active collaboration between the medical technology industry, computer scientists, gastroenterologists, and researchers are critical for the meaningful advancement of AI in gastroenterology. CONCLUSIONS: The consensus process led by the ASGE AI Task Force and experts from various disciplines has shed light on the potential of AI in endoscopy and gastroenterology. AI-based algorithms have shown promise in augmenting endoscopist performance, redefining quality metrics, optimizing workflows, and aiding in predictive modeling and diagnosis. However, challenges remain in evaluating AI algorithms, ensuring transparency and interpretability, addressing governance and data procurement, determining payment models, defining relevant clinical outcomes, and fostering collaboration between stakeholders. Addressing these challenges while maintaining a balanced perspective is crucial for the meaningful advancement of AI in gastroenterology.

13.
Gastrointest Endosc ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331224

RESUMO

BACKGROUND AND AIMS: Resection of colorectal polyps has been shown to decrease the incidence and mortality of colorectal cancer. Large nonpedunculated colorectal polyps are often referred to expert centers for endoscopic resection, which requires relevant information to be conveyed to the therapeutic endoscopist to allow for triage and planning of resection technique. The primary objective of this study was to establish minimum expected standards for the referral of large non-pedunculated colonic polyps for potential endoscopic resection. METHODS: A Delphi method was used to establish consensus on minimum expected standards for the referral of large colorectal polyps among a panel of international endoscopy experts. The expert panel was recruited through purposive sampling, and 3 rounds of surveys were conducted to achieve consensus. Quantitative and qualitative data were analyzed for each round. RESULTS: A total of 24 international experts from diverse continents participated in the Delphi study, resulting in consensus on 19 statements related to the referral of large colorectal polyps. The identified factors, including patient demographic characteristics, relevant medications, lesion factors, photodocumentation, and the presence of a tattoo, were deemed important for conveying the necessary information to therapeutic endoscopists. The mean scores for the statements, which were scored on a scale of 1 to 10, ranged from 7.04 to 9.29, with high percentages of experts considering most statements as a very high priority. Subgroup analysis according to continent revealed some variations in consensus rates among experts from different regions. CONCLUSIONS: The identified consensus statements can aid in improving the triage and planning of resection techniques for large colorectal polyps, ultimately contributing to the reduction of colorectal cancer incidence and mortality.

14.
Endoscopy ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39142348

RESUMO

INTRODUCTION: This study aims to evaluate the effectiveness of ChatGPT (Chat Generative Pretrained Transformer) in answering patients' questions about colorectal cancer (CRC) screening, with the ultimate goal of enhancing patients' awareness and adherence to national screening programs. METHODS: 15 questions on CRC screening were posed to ChatGPT4. The answers were rated by 20 gastroenterology experts and 20 non-experts in three domains (accuracy, completeness, and comprehensibility), and by 100 patients in three dichotomic domains (completeness, comprehensibility and trustability). RESULTS: According to expert rating, the mean accuracy score was 4.8±1.1 on a scale ranging from 1 to 6. Men completeness score was 2.1±0.7 and mean comprehensibility score was 2.8±0.4 on a scale ranging from 1 to 3. Overall, accuracy (4.8±1.1 vs 5.6±0.7, P<0.001) and completeness (2.1±0.7 vs 2.7±0.4, P<0.001) scores were significantly lower for expert compared to non-expert, while comprehensibility was comparable among the two groups (2.7±0.4 vs 2.8±0.3, P=0.546). Patients rated all questions as complete, comprehensible and trustable in 97 to 100% of cases. CONCLUSIONS: ChatGPT shows good performance with the potential to enhance awareness about CRC and improve screening outcomes. Generative language systems may be further improved after proper training in accordance with scientific evidence and current guidelines.

15.
Endoscopy ; 56(2): 102-107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37816393

RESUMO

BACKGROUND: Cold forceps and snares are each effective for removing polyps of 1-3 mm, while snares are more effective for polyps of 4-10 mm in size. If, in the same patient, polyps of 1-3 mm are removed with forceps and those of 4-10 mm with snares, two devices are used. If cold snares are used to resect all lesions of 1-10 mm (one-device colonoscopy), there is a potential for lower costs and less plastic waste. METHODS: A single high detecting colonoscopist prospectively measured the feasibility of cold snaring all colorectal lesions of ≤10 mm in size, along with the associated costs and plastic waste reduction. RESULTS: 677 consecutive lower gastrointestinal endoscopies (not for inflammatory bowel disease) were assessed. Of 1430 lesions of 1-3 mm and 1685 lesions of 4-10 mm in size, 1428 (99.9%, 95%CI 99.5%-100%) and 1674 (99.3%, 95%CI 98.8%-99.7%), respectively, were successfully resected using cold snaring. Among 379 screening and surveillance patients, universal cold snaring of lesions ≤10 mm saved 35 and 47 cold forceps per 100 screening and surveillance patients, respectively. CONCLUSION: Cold snare resection of all lesions ≤10 mm (one-device colonoscopy) was feasible, and reduced costs and plastic waste.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Humanos , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Redução de Custos , Estudos de Viabilidade , Microcirurgia , Neoplasias Colorretais/cirurgia
16.
Endoscopy ; 56(1): 31-40, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37591258

RESUMO

BACKGROUND: There is limited evidence on the comparative diagnostic performance of endoscopic tissue sampling techniques for subepithelial lesions. We performed a systematic review with network meta-analysis to compare these techniques. METHODS: A systematic literature review was conducted for randomized controlled trials (RCTs) comparing the sample adequacy and diagnostic accuracy of bite-on-bite biopsy, mucosal incision-assisted biopsy (MIAB), endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and EUS-guided fine-needle biopsy (FNB). Results were expressed as relative risk (RR) and 95%CI. RESULTS: Eight RCTs were identified. EUS-FNB was significantly superior to EUS-FNA in terms of sample adequacy (RR 1.20 [95%CI 1.05-1.45]), whereas none of the other techniques significantly outperformed EUS-FNA. Additionally, bite-on-bite biopsy was significantly inferior to EUS-FNB (RR 0.55 [95%CI 0.33-0.98]). Overall, EUS-FNB appeared to be the best technique (surface under cumulative ranking [SUCRA] score 0.90) followed by MIAB (SUCRA 0.83), whereas bite-on-bite biopsy showed the poorest performance. When considering lesions <20 mm, MIAB, but not EUS-FNB, showed significantly higher accuracy rates compared with EUS-FNA (RR 1.68 [95%CI 1.02-2.88]). Overall, MIAB ranked as the best intervention for lesions <20 mm (SUCRA score 0.86 for adequacy and 0.91 for accuracy), with EUS-FNB only slightly superior to EUS-FNA. When rapid on-site cytological evaluation (ROSE) was available, no difference between EUS-FNB, EUS-FNA, and MIAB was observed. CONCLUSION: EUS-FNB and MIAB appeared to provide better performance, whereas bite-on-bite sampling was significantly inferior to the other techniques. MIAB seemed to be the best option for smaller lesions, whereas EUS-FNA remained competitive when ROSE was available.


Assuntos
Neoplasias Pancreáticas , Ferida Cirúrgica , Trato Gastrointestinal Superior , Humanos , Metanálise em Rede , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endoscopia , Trato Gastrointestinal Superior/patologia , Neoplasias Pancreáticas/patologia
17.
Endoscopy ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38599622

RESUMO

BACKGROUND: First-line over-the-scope (OTS) clip treatment has shown higher efficacy than standard endoscopic therapy in acute nonvariceal upper gastrointestinal bleeding (NVUGIB) from different causes. We compared OTS clips with through-the-scope (TTS) clips as first-line mechanical treatment in the specific setting of peptic ulcer bleeding. METHODS: We conducted an international, multicenter randomized controlled trial on consecutive patients with suspected NVUGIB. Patients with Forrest Ia-IIb gastroduodenal peptic ulcer were randomized 1:1 to OTS clip or TTS clip treatment. The primary outcome was the rate of 30-day rebleeding after successful initial hemostasis. Secondary outcomes included the rates of successful initial hemostasis and overall clinical success, defined as the composite of successful initial hemostasis and no evidence of 30-day rebleeding. RESULTS: 251 patients were screened and 112 patients were randomized to OTS (n = 61) or TTS (n = 51) clip treatment. The 30-day rebleeding rates were 1.6% (1/61) and 3.9% (2/51) in patients treated with OTS clips and TTS clips, respectively (Kaplan-Meier log-rank, P = 0.46). Successful initial hemostasis rates were 98.4% (60/61) in the OTS clip group and 78.4% (40/51) in the TTS clip group (P = 0.001). Overall clinical success rates were 96.7% (59/61) with OTS clips and 74.5% (38/51) with TTS clips (P = 0.001). CONCLUSIONS: Low rates of 30-day rebleeding were observed after first-line endoscopic treatment of acute peptic ulcer bleeding with either OTS or TTS clips. However, OTS clips showed higher efficacy than TTS clips in achieving successful initial hemostasis and overall clinical success.

18.
Endoscopy ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38942058

RESUMO

Introduction The role of endoscopic submucosal dissection (ESD) in the treatment of Barrett's associated neoplasia (BEN) has been evolving. We examined the efficacy and safety of ESD and EMR for BEN. Methods A database search was performed for studies reporting efficacy and safety outcomes of ESD and EMR for BEN. Pooled proportional and comparative meta-analyses were performed. Results 47 studies (23 ESD, 19 EMR, and 5 comparative) were included. Mean lesion size for ESD and EMR were 22.5 mm and 15.8 mm respectively. Majority of lesions were Paris type IIa. Pooled analysis for ESD showed en-bloc resection, R0 resection, curative resection, and local recurrence rates of 98%, 78%, 65%, and 2%, respectively. Complete eradication of dysplasia (CE-D) and complete eradication of intestinal metaplasia (CE-IM) were achieved in 94% and 59% of cases. Pooled rates of perforation, intraprocedural bleeding (IPB), delayed bleeding (DB), and stricture were 1%, 1%, 2%, and 10%, respectively. Pooled analysis for EMR showed en-bloc resection, R0 resection, curative resection, and local recurrence rates of 37%, 67%, 62%, and 6%, respectively. CE-D and CE-IM were achieved in 94% and 76% of cases. Pooled rates of perforation, IPB, DB, and stricture were 0.1%, 1%, 0.4%, and 7.7%, respectively. The mean procedure time for ESD and EMR were 111.3 and 22.3 mins respectively. Comparative analysis showed higher en-bloc and R0 resection rates with ESD compared to EMR, with comparable adverse events. Conclusion ESD and EMR both can be employed to treat BEN depending on the lesion type, size, and expertise.

19.
Endoscopy ; 56(2): 131-150, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38040025

RESUMO

This ESGE Position Statement provides structured and evidence-based guidance on the essential requirements and processes involved in training in basic gastrointestinal (GI) endoscopic procedures. The document outlines definitions; competencies required, and means to their assessment and maintenance; the structure and requirements of training programs; patient safety and medicolegal issues. 1: ESGE and ESGENA define basic endoscopic procedures as those procedures that are commonly indicated, generally accessible, and expected to be mastered (technically and cognitively) by the end of any core training program in gastrointestinal endoscopy. 2: ESGE and ESGENA consider the following as basic endoscopic procedures: diagnostic upper and lower GI endoscopy, as well as a limited range of interventions such as: tissue acquisition via cold biopsy forceps, polypectomy for lesions ≤ 10 mm, hemostasis techniques, enteral feeding tube placement, foreign body retrieval, dilation of simple esophageal strictures, and India ink tattooing of lesion location. 3: ESGE and ESGENA recommend that training in GI endoscopy should be subject to stringent formal requirements that ensure all ESGE key performance indicators (KPIs) are met. 4: Training in basic endoscopic procedures is a complex process and includes the development and acquisition of cognitive, technical/motor, and integrative skills. Therefore, ESGE and ESGENA recommend the use of validated tools to track the development of skills and assess competence. 5: ESGE and ESGENA recommend incorporating a multimodal approach to evaluating competence in basic GI endoscopic procedures, including procedural thresholds and the measurement and documentation of established ESGE KPIs. 7: ESGE and ESGENA recommend the continuous monitoring of ESGE KPIs during GI endoscopy training to ensure the trainee's maintenance of competence. 9: ESGE and ESGENA recommend that GI endoscopy training units fulfil the ESGE KPIs for endoscopy units and, furthermore, be capable of providing the dedicated personnel, infrastructure, and sufficient case volume required for successful training within a structured training program. 10: ESGE and ESGENA recommend that trainers in basic GI endoscopic procedures should be endoscopists with formal educational training in the teaching of endoscopy, which allows them to successfully and safely teach trainees.


Assuntos
Gastroenterologia , Humanos , Endoscopia Gastrointestinal/métodos , Endoscópios Gastrointestinais , Sociedades Médicas
20.
Endoscopy ; 56(5): 355-363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38278158

RESUMO

BACKGROUND: Gastrointestinal (GI) endoscopy is one of healthcare's main contributors to climate change. We aimed to assess healthcare professionals' attitudes and the perceived barriers to implementation of sustainable GI endoscopy. METHODS: The LEAFGREEN web-based survey was a cross-sectional study conducted by the European Society of Gastrointestinal Endoscopy (ESGE) Green Endoscopy Working Group. The questionnaire comprised 39 questions divided into five sections (respondent demographics; climate change and sustainability beliefs; waste and resource management; single-use endoscopes and accessories; education and research). The survey was available via email to all active members of the ESGE and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) in March 2023. RESULTS: 407 respondents participated in the survey (11% response rate). Most participants (86%) agreed climate change is real and anthropogenic, but one-third did not consider GI endoscopy to be a significant contributor to climate change. Improvement in the appropriateness of endoscopic procedures (41%) and reduction in single-use accessories (34%) were considered the most important strategies to reduce the environmental impact of GI endoscopy. Respondents deemed lack of institutional support and knowledge from staff to be the main barriers to sustainable endoscopy. Strategies to reduce unnecessary GI endoscopic procedures and comparative studies of single-use versus reusable accessories were identified as research priorities. CONCLUSIONS: In this survey, ESGE and ESGENA members acknowledge climate change as a major threat to humanity. Further improvement in sustainability beliefs and professional attitudes, reduction in inappropriate GI endoscopy, and rational use of single-use accessories and endoscopes are critically required.


Assuntos
Atitude do Pessoal de Saúde , Endoscopia Gastrointestinal , Humanos , Estudos Transversais , Feminino , Masculino , Inquéritos e Questionários , Adulto , Mudança Climática , Pessoa de Meia-Idade , Conhecimentos, Atitudes e Prática em Saúde , Endoscópios Gastrointestinais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA