Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 461-472, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38284904

RESUMO

PURPOSE: The purpose of this study was to evaluate a multidisciplinary intervention developed for patients with debilitating chronic pain after total knee arthroplasty (TKA) unresponsive to existing treatment options. METHODS: A treatment-based prospective cohort study was caried out in 30 TKA patients with debilitating chronic pain at least 1 year after TKA. The treatment was a multidisciplinary intervention. Main inclusion criteria: no indication for surgery. Primary outcome was function measured by KOOS-PS, OKS, OKS-APQ and WORQ. Secondary outcome measures were pain, fear of movement, self-efficacy, quality of life (QoL), health care and pain medication use, work rehabilitation and patient satisfaction. The assessments took place pre- and directly posttreatment, at 1, 3 and 12 months follow-up. The clinical relevance was assessed by predefined minimal important clinical change (MCIC). RESULTS: At baseline patients were on average 64.7 (±7.9) years old, 67% were female, and they had knee pain for 42 (10-360) months. The results at 12-month follow-up: first, a significant improvement was shown in function, pain, fear of movement, self-efficacy and QoL. Second, in 38.5%-69.2% of patients clinical relevant improvement was shown for functional outcome, 31% for pain, and 50% for self-efficacy. Third, 42% of patients reported 'no healthcare use in the past three months'. CONCLUSION: One year after a multidisciplinary treatment a clinically relevant improvement was shown in terms of function, pain, self-efficacy and QoL. It seems to be a promising treatment option in this difficult-to-treat patient group with debilitating chronic pain after TKA. Future research should examine the effect of the treatment in a larger study population, considering a control group, and focusing on the working population and evaluating cost-efficacy. LEVEL OF EVIDENCE: Level II.


Assuntos
Artroplastia do Joelho , Dor Crônica , Osteoartrite do Joelho , Humanos , Feminino , Masculino , Artroplastia do Joelho/efeitos adversos , Qualidade de Vida , Osteoartrite do Joelho/cirurgia , Dor Crônica/etiologia , Dor Crônica/terapia , Estudos Prospectivos , Recuperação de Função Fisiológica , Articulação do Joelho/cirurgia , Resultado do Tratamento , Medidas de Resultados Relatados pelo Paciente
2.
Artigo em Inglês | MEDLINE | ID: mdl-39224030

RESUMO

PURPOSE: After unsatisfactory results in a first-in-human clinical investigation with an anatomically shaped medial meniscus prosthesis, the prosthesis and its fixation technique were altered. This interim analysis of a prospective single-arm clinical investigation aims to evaluate safety and clinical performance in a first-in-human study with the redesigned meniscus prosthesis system. METHODS: Ten patients suffering from medial postmeniscectomy pain syndrome were treated with the meniscus prosthesis. Patient-reported outcome measures were obtained at baseline and at 6-week, 3-, 6-, and 12-month follow-up. Radiographs and magnetic resonance imaging scans were obtained to evaluate joint degeneration and prosthesis location. RESULTS: The device alterations resolved the issues occurring with the previous design, but four prostheses were explanted after fixation failure or subluxation of the prosthesis. Five out of six patients who reached 1-year follow-up reported a clinically significant improvement of the knee injury and osteoarthritis outcome score pain subscale. Imaging revealed no adverse effects on joint degeneration. CONCLUSION: The failure mechanisms that occurred with the previous design have been resolved, but the new fixation technique introduced new safety issues. Improvement of positioning and fixation techniques are considered essential future adaptations to reduce the risk of failure. The good clinical outcomes reported by the patients reaching 1-year follow-up indicate that the medial meniscus prosthesis is a potential solution for patients suffering from postmeniscectomy pain syndrome. LEVEL OF EVIDENCE: Level II.

3.
J Arthroplasty ; 39(3): 651-657.e1, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37611678

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) can have a number of adverse consequences for patients that might contribute to a poor outcome. This study aimed to prioritize these consequences, from the perspective of patients and knee specialists. METHODS: There were 95 TKA patients and 63 knee specialists who prioritized a set of 29 adverse consequences, based on a previous qualitative study, using a Maximum Difference Scaling method. A hierarchical Bayesian analysis was used to calculate relative importance scores. Differences and agreements between patients versus knee specialists and satisfied versus dissatisfied patients were analyzed using Mann-Whitney-U tests and Kendall's coefficients of concordance. RESULTS: There were 4 out of 5 items in the top-5 of both patients and knee specialists that were similar, however, the ranking was different. The highest-ranked consequence for patients was: "Inability to do normal activities such as walking, cycling, swimming and heavy household chores", while knee specialists ranked: "No improvement in pain during the day" as the highest. "No improvement in walking" was in the patients' top-5, but was not ranked in the top-5 of knee specialists. For satisfied and dissatisfied patients, the top-5 of consequences was similar. CONCLUSION: Comparable perspectives were found for patients versus knee specialists and satisfied versus dissatisfied patients on the importance of adverse consequences after TKA. However, when looking in more detail, differences in ranking of specific subitems suggest that patients place slightly more importance on the inability to perform valued activities, while knee specialists prioritize lack of pain relief to a higher degree.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Teorema de Bayes , Satisfação do Paciente , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Dor/cirurgia , Resultado do Tratamento
4.
J Arthroplasty ; 39(10): 2483-2489, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38759818

RESUMO

BACKGROUND: Variations in defining poor response to total knee arthroplasty (TKA) impede comparisons of response after TKA over time and across hospitals. This study aimed to compare the prevalence, overlap, and discriminative accuracy of 15 definitions of poor response after TKA using 2 databases. METHODS: Data of patients one year after primary TKA from the Dutch Arthroplasty Register (n = 12,275) and the Osteoarthritis Initiative database (n = 204) were used to examine the prevalence, overlap (estimated by Cohen's kappa), and discriminative accuracy (sensitivity, specificity, positive predictive value, negative predictive value, and Youden index) of 15 different definitions of poor response after TKA. In the absence of a gold standard for measuring poor response to TKA, the numeric rating scale satisfaction (≤ 6 'poor responder') and the global assessment of knee impact (dichotomized: ≥ 4 'poor responder') were used as anchors for assessing discriminative accuracy for the Dutch Arthroplasty Register and Osteoarthritis Initiative dataset, respectively. These anchors were chosen based on a prior qualitative study that identified (dis)satisfaction as a central theme of poor responses to TKA by patients and knee specialists. RESULTS: The median (25th to 75th percentile) prevalence of poor responders in the examined definitions was 18.5% (14.0 to 25.5%), and the median Cohen's kappa for the overlap between pairs of definitions was 0.41 (0.32 to 0.59). Median (25th to 75th percentile) sensitivity was 0.45 (0.39 to 0.54), specificity was 0.86 (0.82 to 0.94), positive predictive value was 0.45 (0.34 to 0.62), negative predictive value was 0.89 (0.87 to 0.89), and the Youden index was 0.36 (0.20 to 0.43). CONCLUSIONS: This study found a lack of overlap between different definitions of poor response to TKA. None of the examined definitions adequately classified poor responders to TKA. In contrast, the absence of a poor response could be classified with confidence.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Sistema de Registros , Humanos , Artroplastia do Joelho/estatística & dados numéricos , Feminino , Masculino , Idoso , Osteoartrite do Joelho/cirurgia , Países Baixos/epidemiologia , Pessoa de Meia-Idade , Bases de Dados Factuais , Satisfação do Paciente , Resultado do Tratamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-39259309

RESUMO

INTRODUCTION: This study aimed to rank definitions for measuring poor response one year after TKA, after assessing the face validity and feasibility of existing or newly proposed definitions. MATERIALS AND METHODS: An international, three-round, online modified Delphi study was conducted with sixty-nine panelists from twenty-three countries. Definitions were derived from a literature review or were newly proposed by an expert group. Panelists rated the face validity and feasibility of definitions, and could propose additional new definitions in round 1. Panelists reconsidered their rating of existing definitions, and rated newly suggested definitions (round 2). Definitions with a median score for face validity < 6.5 were removed from the list, and panelists distributed 100 points among the remaining definitions for ranking (round 3). RESULTS: Fifty-one panelists completed all three rounds (response rate 74%), and the prioritized list of definitions in round 3 comprised seventeen definitions. The single-item definition of (dis)satisfaction with the outcome of TKA obtained the highest scores for face validity and feasibility (7.5, and 8.5 respectively), and the definition "No improvement in pain OR daily knee functioning compared to pre-operative status" was the highest prioritized. In general, definitions reflecting change from the perception of patients were higher ranked than definitions requiring both preoperative and postoperative assessment of validated questionnaires. CONCLUSIONS: This study identified seventeen potential definitions of poor response to TKA, offering valuable options for integration into quality assessment investigations. Remarkably, all identified definitions were patient-centered and none were clinician-centered. Single-item questions, capturing change from the patient's viewpoint, appear to be the most practicable format to assess response.

6.
Acta Orthop ; 95: 256-267, 2024 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-38819193

RESUMO

Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and consistent in execution, presentation, reporting, and interpretation. Both authors and reviewers of scientific papers using RSA may use these guidelines, summarized in the Checklist, as a reference. Deviations from these guidelines should have the underlying rationale stated.


Assuntos
Análise Radioestereométrica , Tomografia Computadorizada por Raios X , Humanos , Falha de Prótese , Guias de Prática Clínica como Assunto
7.
J Antimicrob Chemother ; 78(11): 2660-2666, 2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37681570

RESUMO

OBJECTIVES: Antibiotic treatment for bone and joint infections generally lasts for 6 weeks or longer. Linezolid may be a good option for treating bone and joint infections, but there is an increased risk of potential serious adverse drug events (ADEs) when used for more than 28 days. The aim of this study was to obtain detailed information on the type and time to occurrence of the patient-reported ADEs, the dynamics of haematopoiesis over time, and the reasons for early discontinuation of linezolid when used for an intended maximum duration of 12 weeks. METHODS: This single-centre retrospective study was conducted at the Sint Maartenskliniek in The Netherlands. Patients were included if they were planned to use linezolid for more than 28 days. The main reason for discontinuation of linezolid, the ADE according to the Naranjo score, and the time to occurrence of ADEs were analysed. RESULTS: Among 78 patients, drug toxicity led to early discontinuation of linezolid in 11 (14%) patients before and nine (12%) after 28 days of therapy. The median treatment duration was 42 days. Gastrointestinal intolerance (42%) and malaise (32%) were the most common ADEs. In 75% of the cases the ADE occurred within 28 days of therapy. Sixty-seven patients were able to continue linezolid beyond 28 days, 87% of whom completed therapy as scheduled. Severe cytopenia, according to the Common Terminology Criteria for Adverse events (CTCA), was observed in four patients and was reversible after discontinuation of linezolid. One patient suffered optic neuropathy related to linezolid use. CONCLUSIONS: Linezolid could be considered an alternative option to the current standard of IV glycopeptides for the treatment of bone and joint infection for up to 12 weeks. If patients pass the first 28 days of therapy, the likelihood of successful completion of therapy is high with a low risk of serious ADEs.


Assuntos
Artrite Infecciosa , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Oxazolidinonas , Humanos , Linezolida/efeitos adversos , Estudos Retrospectivos , Oxazolidinonas/uso terapêutico , Acetamidas/uso terapêutico , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Artrite Infecciosa/tratamento farmacológico
8.
J Arthroplasty ; 38(12): 2680-2684.e1, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37286056

RESUMO

BACKGROUND: Revision knee arthroplasty (R-KA) is rising globally. Technical difficulty of R-KA varies from liner exchange to full revision. Centralization has been shown to reduce mortality and morbidity rates. The present study aimed to evaluate the association between hospital R-KA volume and overall second revision rate, as well as revision rate for different types of revision. METHODS: The R -KAs between 2010 and 2020 with available data on the primary KA in the Dutch Orthopaedic Arthroplasty Register were included. Minor revisions were excluded. Implant data and anonymous patient characteristics were obtained from the Dutch Orthopaedic Arthroplasty Register. Survival analyses and competing risk analysis were performed per volume category (≤12, 13 to 24, or ≥25 cases/year) at 1, 3, and 5 years following R-KA. There were 8,072 R-KA cases available. Median follow-up was 3.7 years (range 0 to 13.7 years). There were a total of 1,460 second revisions (18.1%) at the end of follow-up. RESULTS: There were no statistically significant differences between second revision rates of the three volume groups. Adjusted hazard ratio for second revision were 0.97 (Confidence Interval (CI) 0.86 to 1.11) for hospitals with 13 to 24 cases/year and 0.94 (CI 0.83 to 1.07) with ≥25 cases/year compared to low volume (≤12 cases/year). Type of revision did not influence second revision rate. CONCLUSION: Second revision rate of R-KA does not seem to be dependent on hospital volume or type of revision in the Netherlands. LEVEL OF EVIDENCE: Level IV, Observational registry study.


Assuntos
Artroplastia do Joelho , Ortopedia , Humanos , Hospitais , Sistema de Registros , Reoperação , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 143(3): 1537-1547, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36243781

RESUMO

INTRODUCTION: Loosening and migration are common modes of aseptic failure following complex revision total knee arthroplasty (rTKA). Metaphyseal cones allow surgeons to negotiate the loss of femoral and tibial bone stock while obtaining stable bony fixation. This study examines the mid-term functional and radiographic outcomes in patients undergoing rTKA utilizing a novel metaphyseal cone system with stems of variable length and fixation methods. METHODS: This two-center retrospective study examined all patients who underwent rTKA with a novel porous, titanium tibial or femoral cone in combination with a stem of variable length and fixation who had a minimum follow-up of 2-years. Outcome analysis was separated into tibial and femoral cones as well as the stem fixation method (hybrid vs. fully cemented). RESULTS: Overall, 123 patients who received 156 cone implants were included (74 [60.2%] tibial only, 16 [13.0%] femoral only, and 33 [26.8%] simultaneous tibial and femoral) with a mean follow-up of 2.76 ± 0.66 years. At 2-years of follow-up the total cohort demonstrated 94.3% freedom from all-cause re-revisions, 97.6% freedom from aseptic re-revisions, and 99.4% of radiographic cone osteointegration. All-cause revision rates did not differ between stem fixation techniques in both the tibial and femoral cone groups. CONCLUSION: The use of a novel porous titanium femoral and tibial metaphyseal cones combined with stems in patients with moderate to severe bone defects undergoing complex revision total knee arthroplasty confers excellent results independent of stem fixation technique. LEVEL OF EVIDENCE: IV, case series.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Titânio , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Porosidade , Desenho de Prótese , Reoperação
10.
Acta Orthop ; 94: 185-190, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37096567

RESUMO

BACKGROUND AND PURPOSE: Rotating hinged knee implants are highly constrained prostheses used in cases in which adequate stability is mandatory. Due to their constraint nature, multidirectional stresses are directed through the bone-cement-implant interface, which might affect fixation and survival. The goal of this study was to assess micromotion of a fully cemented rotating hinged implant using radiostereometric analysis (RSA). PATIENTS AND METHODS: 20 patients requiring a fully cemented rotating hinge-type implant were included. RSA images were taken at baseline, 6 weeks, and 3, 6, 12, and 24 months postoperatively. Micromotion of femoral and tibial components referenced to markers in the bone was assessed with model-based RSA software, using implant CAD models. Total translation (TT), total rotation (TR), and maximal total point motion (MTPM) were calculated (median and range). RESULTS: At 2 years, TTfemur was 0.38 mm (0.15-1.5), TRfemur was 0.71° (0.37-2.2), TTtibia was 0.40 mm (0.08-0.66), TRtibia was 0.53° (0.30-2.4), MTPMfemur was 0.87 mm (0.54-2.8), and MTPMtibia was 0.66 mm (0.29-1.6). Femoral components showed more outliers (> 1 mm, > 1°) compared with tibial components. CONCLUSION: Fixation of this fully cemented rotating hinge-type revision implant seems adequate in the first 2 years after surgery. Femoral components showed more outliers, in contrast to previous RSA studies on condylar revision total knee implants.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Humanos , Seguimentos , Análise Radioestereométrica/métodos , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Articulação do Joelho/cirurgia , Resultado do Tratamento , Falha de Prótese
11.
Knee Surg Sports Traumatol Arthrosc ; 30(4): 1273-1281, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33860338

RESUMO

PURPOSE: The present study assessed the effect of insert articular surface geometry (anatomical versus conventional insert design) on anteroposterior (AP) translation and varus-valgus (VV) laxity in balanced posterior cruciate ligament (PCL) retaining total knee arthroplasty (TKA). Secondly, we evaluated if the AP translation and VV laxity in the reconstructed knee resembled the stability of the native knee. METHODS: Nine fresh-frozen full-leg cadaver specimens were used in this study. After testing the native knee, anatomical components of a PCL-retaining implant were implanted. The knee joints were subjected to anteriorly and posteriorly directed forces (at 20° and 90° flexion) and varus-valgus stresses (at 20°, 45° and 90° flexion) in both non-weightbearing and weightbearing situations in a knee kinematics simulator. Measurements were performed in the native knee, TKA with anatomical insert geometry (3° built-in varus, medial concave, lateral convex), and TKA with symmetrical insert geometry. RESULTS: In weightbearing conditions, anterior translations ranged between 2.6 and 3.9 mm at 20° flexion and were < 1 mm at 90° flexion. Posterior translation at 20° flexion was 2.7 mm for the native knee versus 4.0 mm (p = 0.047) and 7.0 mm (p = 0.02) for the symmetrical insert and the anatomical insert, respectively. Posterior translation at 90° flexion was < 1.1 mm and not significantly different between the native knee and insert types. In non-weightbearing conditions, the anterior translation at 20° flexion was 5.9 mm for the symmetrical and 4.6 mm for the anatomical insert (n.s.), compared with 3.0 mm for the native knee (p = 0.02). The anterior translation at 90° flexion was significantly higher for the reconstructed knees (anatomical insert 7.0 mm; symmetrical insert 9.2 mm), compared with 1.6 mm for the native knee (both p = 0.02). Varus-valgus laxity at different flexion angles was independent of insert geometry. A valgus force in weightbearing conditions led to significantly more medial laxity (1°-3° opening) in the native knee at 45° and 90° flexion compared with the reconstructed knee for all flexion angles. CONCLUSIONS: Insert geometry seems to have a limited effect with respect to AP translation and VV laxity, in the well-balanced PCL-retaining TKA with an anatomical femoral component. Secondly, AP translation and VV laxity in the reconstructed knee approximated the laxity of the native knee.


Assuntos
Artroplastia do Joelho , Instabilidade Articular , Prótese do Joelho , Ligamento Cruzado Posterior , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular
12.
J Arthroplasty ; 37(3): 482-487, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34864066

RESUMO

BACKGROUND: Clinical observations revealed higher rates of aseptic loosening for hybrid fixated rotating hinge knee implants compared to fully cemented ones. We hypothesize that the use of a fully cemented fixation technique had a higher survival rate for aseptic loosening compared to a hybrid fixation technique in a rotating hinge knee implant. METHODS: All procedures of patients who were treated with the RT-PLUS rotating hinge knee implant (Smith & Nephew, Memphis, TN) between 2010 and 2018 were included. Primary outcome was revision for aseptic loosening. Kaplan-Meier survivorship and Cox proportional hazard regression analysis were performed to calculate survival rates and hazard ratios. RESULTS: A total of 275 hinge knee implants were placed in 269 patients (60 primary procedures, 215 revisions). Median follow-up was 7.3 ± 3.9 years. In total, 24 components (16 hybrid femur, 2 fully cemented femur, 6 hybrid tibia; all revision procedures) in 19 patients were revised for aseptic loosening. Kaplan-Meier survivorship analysis showed superior survival rates of fully cemented components (femur 97.1%; tibia 100%) compared to hybrid fixated components (femur 89.5%; tibia 95.9%) at the 10-year follow-up. Multivariate Cox hazard analysis showed a significantly higher risk of aseptic loosening for hybrid fixated components, a prior stemmed component and the femoral component. CONCLUSION: Fully cemented fixation showed superior survival rates for aseptic loosening compared to hybrid fixation in a single design rotating hinge knee implant. A prior stemmed component appears to be a risk factor for aseptic loosening and the femoral component seems to be more prone to loosening.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Fêmur/cirurgia , Humanos , Prótese do Joelho/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
13.
Eur J Clin Microbiol Infect Dis ; 40(6): 1283-1290, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33479882

RESUMO

Ruling out an infection in one-stage knee and hip revisions for presumed aseptic failure by conventional tissue cultures takes up to 14 days. Multiplex polymerase chain reaction (mPCR) is a quick test (4-5 h) for detecting pathogens. The purpose of this study was to evaluate the diagnostic accuracy of an automated mPCR of synovial fluid obtained intraoperatively in unsuspected knee and hip revisions. A prospective study was conducted with 200 patients undergoing a one-stage knee or hip revision. Synovial fluid was analyzed with the mPCR Unyvero implant and tissue infection G2 cartridge (U-ITI G2) system and compared to intraoperative tissue cultures. The primary outcome measure was the diagnostic accuracy, including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), of the mPCR U-ITI G2 system compared to conventional cultures. In the knee revision group, there were no patients with a positive mPCR in combination with positive cultures. This resulted in a non-calculable sensitivity and PPV. The specificity and NPV in the knee revision group of the mPCR compared to tissue cultures was 96.8% and 96.8%, respectively. In the hip revision group, the sensitivity, specificity, PPV, and NPV of the mPCR compared to tissue cultures was 36.4%, 96.6%, 57.1%, and 92.5%, respectively. Sixteen mismatches occurred between the mPCR and tissue cultures. The mPCR U-ITI G2 system is a quick and reliable synovium fluid test for ruling out infection in presumed aseptic knee and hip revisions with a high NPV compared with tissue cultures, although some mismatches were observed. Periprosthetic tissue cultures are still advised as back-up for false negative and positive mPCR test results.


Assuntos
Bactérias/isolamento & purificação , Quadril/microbiologia , Joelho/microbiologia , Reação em Cadeia da Polimerase Multiplex/métodos , Infecções Relacionadas à Prótese/microbiologia , Idoso , Artroplastia de Quadril/efeitos adversos , Bactérias/classificação , Bactérias/genética , Bactérias/crescimento & desenvolvimento , Feminino , Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia
14.
BMC Musculoskelet Disord ; 22(1): 700, 2021 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-34404359

RESUMO

BACKGROUND: Patients undergoing total knee arthroplasty (TKA) tend to be younger and tend to receive TKA at an earlier stage compared to 20 years ago. The Oxford Knee Score - Activity and Participation (OKS-APQ) questionnaire evaluates higher levels of activity and participation, reflecting activity patterns of younger or more active people. The purpose of this study was to translate the OKS-APQ questionnaire into Dutch, and to evaluate its measurement properties in pre- and postoperative TKA patients. METHODS: The OKS-APQ was translated and adapted according to the forward-backward translation multi step approach and tested for clinimetric quality. Floor and ceiling effects, structural validity, construct validity, internal consistency and test-retest reliability were evaluated using COSMIN quality criteria. The OKS-APQ, the Oxford Knee Score (OKS), the Short Form-36 (SF-36), a Visual Analogue Scale (VAS) for pain and the Forgotten Joint Score (FJS) were assessed in 131 patients (72 preoperative and 59 postoperative TKA patients), and the OKS-APQ was administered twice in 50 patients (12 preoperative and 38 postoperative TKA patients), after an interval of minimal 2 weeks. RESULTS: Floor effects were observed in preoperative patients. Confirmatory factor analyses (CFA) indicated a good fit of a 1-factor model by the following indices: (Comparative Fit Index (CFI): 0.97, Tucker-Lewis Index (TLI): 0.96 and Standardized Root Mean Square Residual (SRMR): 0.03). Construct validity was supported as > 75% of the hypotheses were confirmed. Internal consistency (Cronbach α's from 0.81 to 0.95) was good in the pooled and separate pre- and postoperative samples and test-retest reliability (Intraclass Correlation Coefficients (ICCs) from 0.63 - 0.85) were good in postoperative patients and moderate in preoperative patients. The standard Error of Measurements (SEMs) ranged from 8.5 - 12.2 and the Smallest Detectable Changes in individuals (SDCind) ranged from 23.5 - 34.0 (on a scale from 0 to 100). CONCLUSIONS: Preliminary findings suggest that the Dutch version of the OKS-APQ is reliable and valid for a Dutch postoperative TKA patient sample. However, in a preoperative TKA sample, the OKS-APQ seems less suitable, because of floor effects and lower test-retest reliability. The Dutch version of the OKS-APQ can be used alongside the OKS to discriminate among levels of activity and participation in postoperative patients.


Assuntos
Comparação Transcultural , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/cirurgia , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários , Traduções
15.
Clin Orthop Relat Res ; 478(9): 2057-2064, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32023232

RESUMO

BACKGROUND: Accurate quantification of bone loss facilitates preoperative planning and standardization for research purposes in patients who undergo revision TKA. The most commonly used classification to rate bone defects in this setting, the Anderson Orthopaedic Research Institute classification, does not quantify diaphyseal bone loss and reliability has not been well studied. QUESTIONS/PURPOSES: We developed a new classification scheme to rate bone defects in patients undergoing revision TKA and tested (1) the intraobserver and interobserver reliability of this classification for revision TKA based on preoperative radiographs, and (2) whether additional CT images might improve interobserver reliability. METHODS: This was a preregistered observational study. Interobserver reliability was analyzed using preoperative radiographs of 61 patients who underwent (repeat) revision TKA, and their bone defects were rated by five experienced orthopaedic surgeons. For intraobserver reliability, ratings were repeated at least 2 weeks after the first rating (Timepoints 1 and 2). Directly after the radiographic assessments of Timepoint 2, the observers were provided with CT images of each patient and asked to rate the bone defects for a third time (Timepoint 3), to assess the additional value of CT. Intraobserver and interobserver reliability were tested using Gwet's agreement coefficient 2, which is a measure of agreement between observers in categorical data. Substantial agreement was defined as coefficients between 0.61 to 0.8 and almost perfect agreement as > 0.8. RESULTS: The intraobserver reliability varied between 0.55 (95% CI 0.40 to 0.71) and 0.87 (95% CI 0.78 to 0.96) in the epiphysis, between 0.69 (95% CI 0.58 to 0.80) and 0.98 (95% CI 0.95 to 1) in the metaphysis, and between 0.95 (95% CI 0.90 to 0.99) and 0.99 (95% CI 0.98 to 1) in the diaphysis. The interobserver reliability varied between 0.48 (95% CI 0.39 to 0.57) and 0.49 (95% CI 0.42 to 0.56) in the epiphysis and between 0.81 (95% CI 0.75 to 0.87) and 0.88 (95% CI 0.83 to 0.93) in the metaphysis, and was 0.96 (95% CI 0.93 to 0.99) in the diaphysis at Timepoint 1. The interobserver reliability at Timepoint 2 was similar to that of Timepoint 1. The addition of CT images did not improve reliability (Timepoint 3). CONCLUSIONS: The bone defect classification was less reliable in the epiphyseal area compared with the metaphysis and diaphysis. This finding may be explained by prosthetic components obscuring this region or the more severe bone defects in this region. The addition of CT scans did not improve reliability. Further testing of reliability with observers from other institutions is necessary, as well as validity testing, by testing the classification in relation to intraoperative findings. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Artroplastia do Joelho , Doenças Ósseas/classificação , Fêmur/diagnóstico por imagem , Reoperação , Tíbia/diagnóstico por imagem , Doenças Ósseas/diagnóstico por imagem , Diáfises/diagnóstico por imagem , Epífises/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pré-Operatório , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
16.
BMC Musculoskelet Disord ; 21(1): 378, 2020 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-32534571

RESUMO

BACKGROUND: A significant proportion of patients experiences poor response (i.e. no or little improvement) after total knee arthroplasty (TKA) because of osteoarthritis. It is difficult to quantify the proportion of patients who experiences poor response to TKA, as different definitions of, and perspectives (clinician's and patient's) on poor response are being used. The aim of this study was therefore to review the literature and summarize definitions of poor response to TKA. METHODS: A systematic search was performed to identify and review studies that included dichotomous definitions of poor outcome after primary TKA. The type, amount and combination of domains (e.g. functioning), outcome measures, type of thresholds (absolute/relative, change/cut-off), values and moments of follow-up used in definitions were summarized. RESULTS: A total of 47 different dichotomous definitions of poor response to TKA were extracted from 2163 initially identified studies. Thirty-six definitions incorporated one domain, seven definitions comprised two domains and four definitions comprised three domains. Eight different domains were used in identified definitions: pain, function, physical functioning, quality of life (QoL), patient satisfaction, anxiety, depression and patient global assessment. The absolute cut-off value was the most common type of threshold, with large variety in value and timing of follow-up. CONCLUSIONS: Our inventory review shows that definitions of poor response to TKA are heterogeneous. Our findings stresses the need for an unambiguous definition of poor response to draw conclusions about the prevalence of poor-responders to TKA across hospitals and countries, and to identify patients at risk.


Assuntos
Artroplastia do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente/estatística & dados numéricos , Artroplastia do Joelho/psicologia , Humanos , Osteoartrite do Joelho/psicologia , Medição da Dor , Qualidade de Vida , Recuperação de Função Fisiológica , Resultado do Tratamento
17.
BMC Med Inform Decis Mak ; 20(1): 92, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32414368

RESUMO

BACKGROUND: To evaluate the effect of a stand-alone mobile and web-based educational intervention (eHealth tool) compared to usual preparation of a first orthopedic consultation of patients with hip or knee osteoarthritis (OA) on patients' satisfaction. METHODS: A two-armed randomized controlled trial involving 286 patients with (suspicion of) hip or knee OA, randomly allocated to either receiving an educational eHealth tool to prepare their upcoming consultation (n = 144) or usual care (n = 142). Satisfaction with the consultation on three subscales (range 1-4) of the Consumer Quality Index (CQI - primary outcome) and knowledge (assessed using 22 statements on OA, range 0-22), treatment beliefs (assessed by the Treatment beliefs in OsteoArthritis questionnaire, range 1-5), assessment of patient's involvement in consultation by the surgeon (assessed on a 5-point Likert scale) and patient satisfaction with the outcome of the consultation (numeric rating scale), were assessed. RESULTS: No differences between groups were observed on the 3 subscales of the CQI (group difference (95% CI): communication 0.009 (- 0.10, 0.12), conduct - 0.02 (- 0.12, 0.07) and information provision 0.02 (- 0.18, 0.21)). Between group differences (95% CI) were in favor of the intervention group for knowledge (1.4 (0.6, 2.2)), negative beliefs regarding physical activities (- 0.19 (- 0.37, - 0.002) and pain medication (- 0.30 (- 0.49, - 0.01)). We found no differences on other secondary outcomes. CONCLUSIONS: An educational eHealth tool to prepare a first orthopedic consultation for hip or knee OA does not result in higher patient satisfaction with the consultation, but it does influence cognitions about osteoarthritis. TRIAL REGISTRATION: Dutch Trial Register (trial number NTR6262). Registered 30 January 2017.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Telemedicina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/tratamento farmacológico , Osteoartrite do Joelho/tratamento farmacológico , Pacientes , Encaminhamento e Consulta , Resultado do Tratamento
18.
J Arthroplasty ; 35(6): 1671-1677, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32070659

RESUMO

BACKGROUND: There is limited information about long-term clinical outcomes following revision total knee arthroplasty (TKA) in relation to the indication for revision. Previously, a clear relation between indication for revision and clinical outcome was shown after 2 years. Present study evaluated (1) whether the reported association at 2 year remains present at 7.5 years, and (2) how clinical outcome at 7.5 years developed compared to baseline and 2-year follow-up, and (3) whether patients had additional adverse events. METHODS: A cohort of 129 patients with a total system revision TKA was selected. Range of motion, Visual Analog Scale for pain and satisfaction, and clinical and functional Knee Society Score were obtained preoperatively, at 3 months, 1, 2, and 7.5 years. Reasons for revision were septic loosening, aseptic loosening, malposition, instability, and severe stiffness. RESULTS: Patients revised for severe stiffness had significantly worse outcomes. No difference was found between the other indications. The clinical outcome after revision TKA at 7.5 years remained stable for septic and aseptic loosening, malposition, and instability but deteriorated slightly for the severe stiffness group. Visual Analog Scale satisfaction remained constant for all indications. There were 11 additional complications between 2- and 7.5-year follow-up, 9 of which necessitated reoperation. CONCLUSION: All indications except severe stiffness had a similar clinical outcome which was maintained up to 7.5-year follow-up. The severe stiffness group had worse outcomes and deteriorated slightly at longer follow-up. Outcome at 3 months seems predictive for long-term outcome. Additional complications did not differ significantly for the different reasons for revision. LEVEL OF EVIDENCE: Level III, prognostic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Falha de Prótese , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Escala Visual Analógica
19.
Arch Orthop Trauma Surg ; 140(10): 1495-1501, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32468168

RESUMO

INTRODUCTION: Physiological motion after total knee arthroplasty (TKA) should result in a large range of motion, which would lead to good clinical outcomes. An adjusted design of a bicruciate-stabilizing TKA was developed to reproduce physiological motion. The aim of this study was to (1) investigate the maximal knee flexion of this knee system, 1 year post-operatively; (2) determine the clinical and functional improvement and compare the outcomes between patients with and without high maximal flexion; and (3) evaluate the adverse events. MATERIALS AND METHODS: In this prospective study, 62 patients with osteoarthritis received a bicruciate-stabilizing TKA. Maximum flexion was measured on a lateral X-ray pre- and post-operatively. Clinical and functional scores and the adverse events were reported up until 2 years after surgery. RESULTS: Pre-operatively, the median (range) maximal flexion was 131.5 (90-153)° and 1 year post-operatively, it was 130 (82-150)°. The results for the clinical scores showed an improvement between pre-operative values and post-operative values. The Kujala score and Knee Osteoarthritis Outcome Score (KOOS) symptoms, sport and quality of life score were better in patients with high maximal flexion (≥ 125°). Ten (serious) adverse device events were reported. CONCLUSIONS: In conclusion, the bicruciate-stabilizing TKA obtained a maximal flexion comparable to the flexion pre-operatively and resulted in good clinical and functional outcomes. Patients with high flexion ability seem to perform better on clinical and functional outcomes. Furthermore, the adjusted design of the bicruciate-stabilizing TKA reduced the number of adverse events. LEVEL OF EVIDENCE: Prospective cohort study, Level II.


Assuntos
Artroplastia do Joelho , Amplitude de Movimento Articular/fisiologia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/estatística & dados numéricos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Resultado do Tratamento
20.
Acta Orthop Belg ; 86(1): 69-76, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32490776

RESUMO

The goal of this study was to present the results of an anatomical superficial medial collateral ligament (sMCL) reconstruction combined with reefing of the posteromedial capsule in a series of 10 patients with symptomatic valgus instability complaints in combined injuries of the knee. All patients under- went an sMCL reconstruction with reefing of the posteromedial capsule. If cruciate ligament insuf- ficiency was present, this was reconstructed as well. Pre- and postoperatively, multiple subjective knee outcome scores were obtained, and valgus stress radiographs objectively evaluated laxity. Median valgus laxity of the injured knee on valgus stress radiographs improved significantly. There was no statistically significant difference between post- operative valgus laxity of the injured knee and valgus laxity of the uninjured knee. All subjective knee outcome scores improved significantly compared with the preoperative situation. The described procedure restores valgus laxity to a level comparable to the uninjured knee.


Assuntos
Cápsula Articular/cirurgia , Instabilidade Articular/cirurgia , Ligamento Colateral Médio do Joelho/lesões , Ligamento Colateral Médio do Joelho/cirurgia , Adolescente , Adulto , Humanos , Cápsula Articular/fisiopatologia , Instabilidade Articular/fisiopatologia , Ligamento Colateral Médio do Joelho/fisiopatologia , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA