Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
BMC Med Res Methodol ; 24(1): 79, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38539082

RESUMO

BACKGROUND: The E-value, a measure that has received recent attention in the comparative effectiveness literature, reports the minimum strength of association between an unmeasured confounder and the treatment and outcome that would explain away the estimated treatment effect. This study contributes to the literature on the applications and interpretations of E-values by examining how the E-value is impacted by data with varying levels of association of unobserved covariates with the treatment and outcome measure when covariate adjustment is applied. We calculate the E-value after using regression and propensity score methods (PSMs) to adjust for differences in observed covariates. Propensity score methods are a common observational research method used to balance observed covariates between treatment groups. In practice, researchers may assume propensity score methods that balance treatment groups across observed characteristics will extend to balance of unobserved characteristics. However, that assumption is not testable and has been shown to not hold in realistic data settings. We assess the E-value when covariate adjustment affects the imbalance in unobserved covariates. METHODS: Our study uses Monte Carlo simulations to evaluate the impact of unobserved confounders on the treatment effect estimates and to evaluate the performance of the E-Value sensitivity test with the application of regression and propensity score methods under varying levels of unobserved confounding. Specifically, we compare observed and unobserved confounder balance, odds ratios of treatment vs. control, and E-Value sensitivity test statistics from generalized linear model (GLM) regression models, inverse-probability weighted models, and propensity score matching models, over correlations of increasing strength between observed and unobserved confounders. RESULTS: We confirm previous findings that propensity score methods - matching or weighting - may increase the imbalance in unobserved confounders. The magnitude of the effect depends on the strength of correlation between the confounder, treatment, and outcomes. We find that E-values calculated after applying propensity score methods tend to be larger when unobserved confounders result in more biased treatment effect estimates. CONCLUSIONS: The E-Value may misrepresent the size of the unobserved effect needed to change the magnitude of the association between treatment and outcome when propensity score methods are used. Thus, caution is warranted when interpreting the E-Value in the context of propensity score methods.


Assuntos
Projetos de Pesquisa , Humanos , Simulação por Computador , Modelos Lineares , Pontuação de Propensão , Viés
2.
J Cardiovasc Electrophysiol ; 34(4): 1015-1023, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36807378

RESUMO

INTRODUCTION: The Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single-chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all-cause mortality after 3 years of follow-up. METHODS: US Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap-weight adjusted Fine-Gray competing risk models were used to compare outcomes at 3 years. RESULTS: Leadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59-0.78; reintervention HR 0.59; 95% CI 0.44-0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84-0.97). There was no difference in the adjusted 3-year all-cause mortality rate (HR 0.97; 95% CI, 0.92-1.03). CONCLUSION: This nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter-term advantages associated with leadless pacing persist and continue to accrue in the medium-to-long-term.


Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Idoso , Estados Unidos , Seguimentos , Desenho de Equipamento , Medicare , Marca-Passo Artificial/efeitos adversos , Insuficiência Cardíaca/etiologia
3.
Europace ; 25(3): 1041-1050, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36757859

RESUMO

AIMS: This study compares clinical outcomes between leadless pacemakers (leadless-VVI) and transvenous ventricular pacemakers (transvenous ventricular permanent-VVI) in subgroups of patients at higher risk of pacemaker complications. METHODS AND RESULTS: This study is based on the Micra Coverage with Evidence Development (CED) study. Patients from the Micra CED study were considered in a high-risk subgroup if they had a diagnosis of chronic kidney disease Stages 4-5 (CKD45), end-stage renal disease, malignancy, diabetes, tricuspid valve disease (TVD), or chronic obstructive pulmonary disease (COPD) 12 months prior to pacemaker implant. A pre-specified set of complications and reinterventions were identified using diagnosis and procedure codes. Competing risks models were used to compare reinterventions and complications between leadless-VVI and transvenous-VVI patients within each subgroup; results were adjusted for multiple comparisons. A post hoc comparison of a composite outcome of reinterventions and device complications was conducted. Out of 27 991 patients, 9858 leadless-VVI and 12 157 transvenous-VVI patients have at least one high-risk comorbidity. Compared to transvenous-VVI patients, leadless-VVI patients in four subgroups [malignancy, HR 0.68 (0.48-0.95); diabetes, HR 0.69 (0.53-0.89); TVD, HR 0.60 (0.44-0.82); COPD, HR 0.73 (0.55-0.98)] had fewer complications, in three subgroups [diabetes, HR 0.58 (0.37-0.89); TVD, HR 0.46 (0.28-0.76); COPD, HR 0.51 (0.29-0.90)) had fewer reinterventions, and in four subgroups (malignancy, HR 0.52 (0.32-0.83); diabetes, HR 0.52 (0.35-0.77); TVD, HR 0.44 (0.28-0.70); COPD, HR 0.55 (0.34-0.89)] had lower rates of the combined outcome. CONCLUSION: In a real-world study, leadless pacemaker patients had lower 2-year complications and reinterventions rates compared with transvenous-VVI pacing in several high-risk subgroups. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT03039712.


Assuntos
Doenças das Valvas Cardíacas , Falência Renal Crônica , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
4.
Eur Heart J ; 43(12): 1207-1215, 2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-34788416

RESUMO

AIMS: Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. METHODS AND RESULTS: The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data (n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims (n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45-0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60-0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 years was not different between the two groups (adjusted HR 0.97, 95% CI 0.91-1.04, P = 0.37). CONCLUSION: In a real-world study of US Medicare patients, the Micra leadless VVI pacemaker was associated with a 38% lower adjusted rate of reinterventions and a 31% lower adjusted rate of chronic complications compared with transvenous VVI pacing. There was no difference in adjusted all-cause mortality at 2 years.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Idoso , Estimulação Cardíaca Artificial/métodos , Estudos de Coortes , Desenho de Equipamento , Seguimentos , Humanos , Medicare , Resultado do Tratamento , Estados Unidos/epidemiologia
5.
Prev Med ; 105: 135-141, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28890355

RESUMO

Wellness programs are a popular strategy utilized by large U.S. employers. As mobile health applications and wearable tracking devices increase in prevalence, many employers now offer physical activity tracking applications. This longitudinal study evaluates the impact of engagement with a web-based, physical activity tracking program on changes in individuals' biometric outcomes in an employer population. The study population includes active employees and adult dependents continuously enrolled in an eligible health plan and who have completed at least two biometric screenings (n=36,882 person-years with 11,436 unique persons) between 2011 and 2014. Using difference-in-differences (DID) regression, we estimate the effect of participation in the physical activity tracking application on BMI, total cholesterol, and blood pressure. Participation was significantly associated with a reduction of 0.275 in BMI in the post-period, relative to the comparison group, representing a 1% change from baseline BMI. The program did not have a statistically significant impact on cholesterol or blood pressure. Sensitivity checks revealed slightly larger BMI reductions among participants with higher intensity of tracking activity and in the period following the employer's shift to an outcomes-based incentive design. Results are broadly consistent with the existing literature on changes in biometric outcomes from workplace initiatives promoting increased physical activity. Employers should have modest expectations about the potential health benefits of such programs, given current designs and implementation in real-world settings.


Assuntos
Exercício Físico , Promoção da Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Local de Trabalho/psicologia , Adulto , Índice de Massa Corporal , Feminino , Humanos , Estudos Longitudinais , Masculino , Motivação
6.
Heart Rhythm ; 21(1): 66-73, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37742991

RESUMO

BACKGROUND: The Micra AV Coverage with Evidence Development study is a novel analysis of utilization and outcomes associated with Micra AV leadless pacing in US Medicare patients. OBJECTIVE: The purpose of this study was to describe patient characteristics, complications, and outcomes of patients implanted with a Micra AV leadless pacemaker compared with a contemporaneous cohort of patients implanted with a dual chamber transvenous pacemaker. METHODS: Patients implanted with Micra AV (n = 7471) or a dual chamber transvenous pacemaker (n = 107,800) from February 5, 2020, through December 1, 2021, were identified using device registry-linked Medicare claims data. Acute complications were assessed at 30 days, and chronic complications, reinterventions, and all-cause mortality were assessed at 6 months. RESULTS: Patients implanted with Micra AV had higher rates of end-stage renal disease (14.9% vs 2.0%; P < .0001) and overall comorbidity burden (mean Charlson Comorbidity Index 4.9 vs 3.8; P < .0001). There was no difference in the unadjusted rate of complications at 30 days (9.1% vs 8.7%; P = .61), and patients implanted with Micra AV had a significantly lower adjusted rate of complications (8.6% vs 11.0%; P < .0001). At 6 months, patients implanted with Micra AV had significantly lower rates of complications (adjusted hazard ratio 0.50; 95% confidence interval 0.43-0.57; P < .0001) and reinterventions (adjusted hazard ratio 0.46; 95% confidence interval 0.36-0.58; P < .0001). Patients implanted with Micra AV had higher all-cause mortality at 30 days and 6 months, likely because of differences in the underlying risk of mortality. CONCLUSION: Patients implanted with Micra AV had similar rates of complications at 30 days and significantly lower rates of complications and reinterventions at 6 months, despite being sicker than patients implanted with a transvenous pacemaker.


Assuntos
Medicare , Marca-Passo Artificial , Estados Unidos/epidemiologia , Humanos , Idoso , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Próteses e Implantes , Estimulação Cardíaca Artificial/efeitos adversos
7.
PLoS One ; 17(11): e0277685, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36395168

RESUMO

Cost collection using UB-04 forms for economic evaluation is challenging, as UB-04 collection is time and effort intensive and compliance is imperfect. Alternative data sources could overcome those challenges. The objective of this study is to determine the usefulness of UB-04 data in estimating hospital costs compared to clinical case report form (CRF) data. Health care utilization costs were compared from financial information in UB-04s and from an assignment process using CRF data, from the WRAP-IT (23 infections) and the Micra IDE trials (61 adverse events and 108 implants). Charge-based costs were calculated by multiplying charges in UB-04s and hospital-specific Cost-to-Charge ratios from the Centers for Medicare and Medicaid Services cost reports. The cost assignment process used clinical information to find comparable encounters in real world data and assigned an average cost. Paired difference tests evaluated whether both methods yield similar results. The mean difference in total infection related costs between methods in the WRAP-IT trial was $152 +/-$22,565. In the Micra IDE trial, the mean difference in total adverse event related costs between methods was -$355 +/-$8,298 while the mean difference in total implant related costs between methods was $-3,488 +/-$13,859. Wilcoxon tests and generalized linear models could not reject the difference in costs between methods in the first two cases. Cost assignment methods achieve results similar to costs obtained through UB-04s, without the additional investment in time and effort. The use of UB-04 information for services that are not mature in a health care system may present unexpected challenges, necessitating a tradeoff with other methods of cost assignment.


Assuntos
Custos Hospitalares , Medicare , Estados Unidos , Preços Hospitalares , Análise Custo-Benefício
8.
PLoS One ; 17(6): e0270398, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35749428

RESUMO

Diagnosing cardiac pauses that could produce syncopal episodes is important to guide appropriate therapy. However, the infrequent nature of these episodes can make detection challenging with conventional monitoring (CM) strategies with short-term ECG monitors. Insertable cardiac monitors (ICMs) continuously monitor for arrhythmias but present a higher up-front cost. It is not well understood whether these higher costs are offset by the costs of repeat evaluation in CM strategies. We simulated the likelihood of diagnostic success and cost-per-diagnosis of pause arrhythmias with CM strategies compared to ICM monitoring. ICM device data from syncope patients diagnosed with pause arrhythmias was utilized to simulate patient pathways and diagnostic success with CM. We assumed that detected true pause episodes (≥5 seconds) were symptomatic and prompted a hospital encounter and further evaluation with CM. Subsequent true pause episodes in yet-undiagnosed patients triggered additional rounds of CM. Costs of monitoring were accrued at each encounter and represent the U.S. payer perspective. Cost per diagnosed patient was calculated as the total costs accrued for all patients divided by the number of patients diagnosed, across 1,000 simulations. During a mean 505±333 days of monitoring ICM detected 2.4±2.7 pause events per patient, with an average of 109±94 days until the first event. CM was projected to diagnose between 13.8% (24-hour Holter) and 30.2% (two 30-day monitors) of the ICM-diagnosed patients. Total diagnostic costs per ICM-diagnosed patient averaged $7,847, whereas in the CM strategies average cost-per-diagnosis ranged from $12,950±2,589 with 24-hour Holter to $32,977±14,749 for two 30-day monitors. Relative to patients diagnosed with pause arrhythmias via ICM, CM strategies diagnose fewer patients and incur higher costs per diagnosed patient.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Humanos , Síncope/diagnóstico
9.
Health Econ ; 20(12): 1431-47, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22025388

RESUMO

This paper assesses the effects of different health conditions on happiness. Based on new data for Latin America, we examine the effects of different conditions across age, gender, and income cohorts. Anxiety and pain have stronger effects than physical problems, likely because people adapt better to one-time shocks than to constant uncertainty. The negative effects of health conditions are very large when compared with the effects of income on happiness. And, while higher peer income typically elicits envy, better peer health provides positive signals for life and health satisfaction. Health norms vary widely across countries.


Assuntos
Felicidade , Nível de Saúde , Adulto , Feminino , Humanos , América Latina , Masculino , Pessoa de Meia-Idade , Modelos Econométricos , Satisfação Pessoal , Classe Social , Inquéritos e Questionários
10.
J Med Econ ; 24(1): 173-180, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33471579

RESUMO

OBJECTIVE: The mortality benefit of implantable cardioverter defibrillators (ICDs) for primary prevention (PP) of sudden cardiac arrest (SCA) has been well-established, but ICD therapy remains globally underutilized. The results of the Improve SCA study showed a 49% relative risk reduction in all-cause mortality among ICD patients with 1.5 primary prevention (1.5PP) characteristics (patients with one or more risk factors, p < 0.0001). We evaluated the cost-effectiveness of ICD compared to no ICD therapy among patients with 1.5PP characteristics in three Latin American countries and analyzed the factors involved in cost-effectiveness. METHODS: We used a published Markov model that compares costs and outcomes of ICD to no ICD therapy from local payers' perspective and included country-specific and disease-specific inputs from the Improve SCA study and current literature. We used WHO-recommended willingness-to-pay (WTP) thresholds to assess cost-effectiveness and compared model outcomes between countries. RESULTS: Incremental costs per QALY (quality-adjusted life year) saved by ICD compared to no ICD therapy are Colombian Pesos COP$46,729,026 in Colombia, Mexican Pesos MXN$246,016 in Mexico, and Uruguayan Pesos UYU$1,213,614 in Uruguay in the base case scenario; all three figures are between 1-3-times GDP per capita for each country. One-way and probabilistic sensitivity analyses confirm the base case scenario results. Non-cardiac accumulated deaths are lower in Mexico, resulting in a comparatively increased cost-effective ICD therapy. LIMITATIONS: The Improve SCA study was not randomized, so clinical results could be biased; however, measures were taken to reduce this bias. Costs and benefits were modelled beyond the timeline of direct observation in the Improve SCA study. CONCLUSIONS: ICD therapy is cost-effective in Mexico and Uruguay and potentially cost-effective in Colombia for a 1.5PP population. Variability in ICER estimates by country can be explained by differences in non-cardiac deaths and cost inputs.


Assuntos
Desfibriladores Implantáveis , Análise Custo-Benefício , Morte Súbita Cardíaca/prevenção & controle , Humanos , América Latina , Prevenção Primária , Fatores de Risco
11.
Health Serv Res ; 56(5): 919-931, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33569804

RESUMO

OBJECTIVE: To describe physicians' variation in de-adopting concurrent statin and fibrate therapy for type 2 diabetic patients following a reversal in clinical evidence. DATA SOURCES: We analyzed 2007-2015 claims data from OptumLabs® Data Warehouse, a longitudinal, real-world data asset with de-identified administrative claims and electronic health record data. STUDY DESIGN: We modeled fibrate use among Medicare Advantage and commercially insured type 2 diabetic statin users before and after the publication of the ACCORD lipid trial, which found statins and fibrates were no more effective than statins alone in reducing cardiovascular events among type 2 diabetic patients. We modeled fibrate use trends with physician random effects and physician characteristics such as age and specialty. DATA EXTRACTION: We identified patient-year-quarters with one year of continuous insurance enrollment, type 2 diabetes diagnoses, and fibrate use. We designated the physician most responsible for patients' diabetes care based on evaluation and management visits and prescriptions of glucose-lowering drugs. PRINCIPAL FINDINGS: Fibrate use increased by 0.12 percentage points per quarter among commercial patients (95% CI, 0.10 to 0.14) and 0.17 percentage points per quarter among Medicare Advantage patients (95% CI, 0.13 to 0.20) before the trial and then decreased by 0.16 percentage points per quarter among commercial patients (95% CI, -0.18 to -0.15) and 0.05 percentage points per quarter among Medicare Advantage patients (95% CI, -0.06 to -0.03) after the trial. However, 45% of physicians treating commercial patients and 48% of physicians treating Medicare Advantage patients had positive trends in prescribing following the trial. Physicians' characteristics did not explain their variation (pseudo R2  = 0.000). CONCLUSION: On average, physicians decreased fibrate prescribing following the ACCORD lipid trial. However, many physicians increased prescribing following the trial. Observable physician characteristics did not explain variations in prescribing. Future research should examine whether physicians vary similarly in other de-adoption settings.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Ácidos Fíbricos/administração & dosagem , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Hipolipemiantes/administração & dosagem , Padrões de Prática Médica/estatística & dados numéricos , Idoso , Quimioterapia Combinada , Uso de Medicamentos , Feminino , Ácidos Fíbricos/uso terapêutico , Fidelidade a Diretrizes , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipoglicemiantes/uso terapêutico , Hipolipemiantes/uso terapêutico , Estudos Longitudinais , Masculino , Medicare Part C/estatística & dados numéricos , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Fatores de Risco , Estados Unidos
12.
PLoS One ; 15(11): e0241697, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33211698

RESUMO

OBJECTIVE: Implantable cardiac defibrillators (ICDs) for primary prevention (PP) of sudden cardiac arrest (SCA) are well-established but underutilized globally. The Improve SCA study has identified a cohort of patients called 1.5 primary prevention (1.5PP) based on PP patients with the presence of certain risk factors. We evaluated the cost-effectiveness of ICD therapy compared to no ICD among the PP population and the subset of 1.5PP patients in Taiwan. METHODS: A Markov model was run over a lifetime time horizon from the Taiwan payer perspective. Mortality and utility estimates were obtained from the literature (PP) and the IMPROVE SCA trial (1.5PP). Cost inputs were obtained from the Taiwan National Health Insurance Administration (NHIA), Ministry of Health and Welfare. We used a willingness-to-pay (WTP) threshold of NT$2,100,000, as established through standard WTP research methods and in alignment with World Health Organization recommendations. RESULTS: The total discounted costs for ICD therapy and no ICD therapy were NT$1,664,259 and NT$646,396 respectively for PP, while they were NT$2,410,603 and NT$905,881 respectively for 1.5PP. Total discounted QALYs for ICD therapy and no ICD therapy were 6.48 and 4.98 respectively for PP, while they were 10.78 and 7.71 respectively for 1.5PP. The incremental cost effectiveness ratio was NT$708,711 for PP and NT$441,153 for 1.5PP, therefore ICD therapy should be considered cost effective for PP and highly cost effective for 1.5PP. CONCLUSIONS: ICD therapy compared to no ICD therapy is cost-effective in the whole PP population and highly cost-effective in the subset 1.5PP population in Taiwan.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária/métodos , Feminino , Humanos , Masculino , Cadeias de Markov , Anos de Vida Ajustados por Qualidade de Vida , Fatores de Risco
13.
Int J Health Econ Manag ; 20(3): 299-317, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32350680

RESUMO

High-quality health care not only includes timely access to effective new therapies but timely abandonment of therapies when they are found to be ineffective or unsafe. Little is known about changes in use of medications after they are shown to be ineffective or unsafe. In this study, we examine changes in use of two medications: fenofibrate, which was found to be ineffective when used with statins among patients with Type 2 diabetes (ACCORD lipid trial); and dronedarone, which was found to be unsafe in patients with permanent atrial fibrillation (PALLAS trial). We examine the patient and provider characteristics associated with a decline in use of these medications. Using Medicare fee-for-service claims from 2008 to 2013, we identified two cohorts: patients with Type 2 diabetes using statins (7 million patient-quarters), and patients with permanent atrial fibrillation (83 thousand patient-quarters). We used interrupted time-series regression models to identify the patient- and provider-level characteristics associated with changes in medication use after new evidence emerged for each case. After new evidence of ineffectiveness emerged, fenofibrate use declined by 0.01 percentage points per quarter (95% CI - 0.02 to - 0.01) from a baseline of 6.9 percent of all diabetes patients receiving fenofibrate; dronedarone use declined by 0.13 percentage points per quarter (95% CI - 0.15 to - 0.10) from a baseline of 3.8 percent of permanent atrial fibrillation patients receiving dronedarone. For dronedarone, use declined more quickly among patients dually-enrolled in Medicare and Medicaid compared to Medicare-only patients (P < 0.001), among patients seen by male providers compared to female providers (P = 0.01), and among patients seen by cardiologists compared to primary care providers (P < 0.001).


Assuntos
Medicina Baseada em Evidências , Padrões de Prática Médica/tendências , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Bases de Dados Factuais , Diabetes Mellitus Tipo 2/tratamento farmacológico , Dronedarona/uso terapêutico , Feminino , Fenofibrato/uso terapêutico , Humanos , Hipolipemiantes/uso terapêutico , Masculino , Medicare , Estados Unidos
15.
J Health Econ ; 60: 90-97, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29940410

RESUMO

Tiered and narrow provider networks are mechanisms implemented by health plans to reduce health care costs. The benefits of narrow networks for consumers usually come in the form of lower premiums in exchange for access to fewer providers. Narrow networks may disrupt continuity of care and access to usual sources of care. We examine choices of health plans in a private health insurance exchange where consumers choose among one broad network and four narrow network plans. Using a discrete choice model with repeated choices, we estimate the willingness to pay for a health plan that covers consumers' usual sources of care. Willingness to pay for a network that covers consumers' usual source of care is between $84 and $275/month (for primary care) and between $0 and $115/month (for specialists). We find that, given that a network covers their usual source of care, consumers show aversion only to the narrowest networks.


Assuntos
Continuidade da Assistência ao Paciente , Financiamento Pessoal , Controle de Acesso , Acessibilidade aos Serviços de Saúde/economia , Adulto , Comportamento de Escolha , Feminino , Trocas de Seguro de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Econométricos , Atenção Primária à Saúde , Estados Unidos
18.
Am J Manag Care ; 23(6): e180-e185, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28817293

RESUMO

OBJECTIVES: To compare the performance of methods to retrospectively attribute patients to provider systems by comparing the fraction attributed and the stability of assignment over time. STUDY DESIGN: Retrospective cross-sectional study. METHODS: Descriptive statistics are used to measure the fraction of patients attributed and stability of attribution from year to year. This study uses a panel of administrative claims data (2010-2011). Attribution rules were defined by unit of measure (count of physician visits, dollars paid), type of providers (primary care physicians [PCPs], all physicians), type of encounters (all visits, evaluation and management visits only), and level of concentration of care (majority, plurality). We created 32 retrospective attribution rules, spanning PCP-only rules, all-physician rules, hierarchical rules based on PCPs then all physicians, and lookback rules based on current-year PCP visits then prior-year experience. RESULTS: All methods exhibit a tradeoff between stability of attribution and fraction of the population attributed. This tradeoff is minimized when PCP-based rules are supplemented by a 1-year lookback when the current-year experience does not result in attribution. CONCLUSIONS: We recommend using this lookback method when multiple years of data are available. In absence of multiple years of data, PCP-based rules maximize stability; hierarchical rules result in a greater fraction attributed with less loss of stability than simple all-provider rules.


Assuntos
Seguro Saúde/organização & administração , Adolescente , Adulto , Estudos Transversais , Atenção à Saúde/economia , Atenção à Saúde/estatística & dados numéricos , Nível de Saúde , Humanos , Seguro Saúde/economia , Seguro Saúde/estatística & dados numéricos , Pessoa de Meia-Idade , Médicos de Atenção Primária/economia , Médicos de Atenção Primária/organização & administração , Médicos de Atenção Primária/normas , Estudos Retrospectivos , Adulto Jovem
19.
Perm J ; 21: 16-102, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28406788

RESUMO

CONTEXT: Long-term adherence to pharmaceutical treatment for multiple sclerosis (MS) is poor. A focus on patient preferences when determining the patient's therapeutic plan may improve this experience. OBJECTIVE: To identify factors important to patients with MS when evaluating their options for pharmaceutical agents that deliver disease-modifying therapy. DESIGN: Stated-choice experiment to a sample of patients with MS from privately and publicly insured enrollees in a regional health plan. The experiment presented each respondent with a set of 8 drug choices for MS, asking them to select their preferred disease-modifying agent (DMA). Each respondent was randomized to 1 of 6 possible sets of 8 drug choices, for a total of 48 drug pairings in the experiment. Each choice included 2 hypothetical DMAs and a "no drug" option. Drug attributes included dosage type and modality, efficacy, relapse risk, and drug side effects. RESULTS: The "no drug" alternative was a stronger substitute than the alternative drug when the focal drug characteristics changed, and the most important drivers of choice were type of side effects and risk of severe relapse. DISCUSSION: The heterogeneity of our sample and the inclusion of a "no drug" alternative in the DMA choice scenarios make this study an important contribution to this body of literature. The importance of the "no drug" alternative in our results is consistent with poor long-term adherence to DMAs. CONCLUSION: Patient-centered MS therapy using DMAs should include discussion of side effects and relapse risk.


Assuntos
Atitude Frente a Saúde , Comportamento de Escolha , Esclerose Múltipla/tratamento farmacológico , Preferência do Paciente , Assistência Centrada no Paciente , Adulto , Idoso , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Feminino , Humanos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Assistência Centrada no Paciente/normas , Preparações Farmacêuticas , Recidiva , Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA