Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
NPJ Digit Med ; 6(1): 39, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36914699

RESUMO

We present a robust insulin delivery system that includes automated meal detection and carbohydrate content estimation using machine learning for meal insulin dosing called robust artificial pancreas (RAP). We conducted a randomized, single-center crossover trial to compare postprandial glucose control in the four hours following unannounced meals using a hybrid model predictive control (MPC) algorithm and the RAP system. The RAP system includes a neural network model to automatically detect meals and deliver a recommended meal insulin dose. The meal detection algorithm has a sensitivity of 83.3%, false discovery rate of 16.6%, and mean detection time of 25.9 minutes. While there is no significant difference in incremental area under the curve of glucose, RAP significantly reduces time above range (glucose >180 mg/dL) by 10.8% (P = 0.04) and trends toward increasing time in range (70-180 mg/dL) by 9.1% compared with MPC. Time below range (glucose <70 mg/dL) is not significantly different between RAP and MPC.

2.
Lancet Digit Health ; 5(9): e607-e617, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37543512

RESUMO

BACKGROUND: Exercise can rapidly drop glucose in people with type 1 diabetes. Ubiquitous wearable fitness sensors are not integrated into automated insulin delivery (AID) systems. We hypothesised that an AID can automate insulin adjustments using real-time wearable fitness data to reduce hypoglycaemia during exercise and free-living conditions compared with an AID not automating use of fitness data. METHODS: Our study population comprised of individuals (aged 21-50 years) with type 1 diabetes from from the Harold Schnitzer Diabetes Health Center clinic at Oregon Health and Science University, OR, USA, who were enrolled into a 76 h single-centre, two-arm randomised (4-block randomisation), non-blinded crossover study to use (1) an AID that detects exercise, prompts the user, and shuts off insulin during exercise using an exercise-aware adaptive proportional derivative (exAPD) algorithm or (2) an AID that automates insulin adjustments using fitness data in real-time through an exercise-aware model predictive control (exMPC) algorithm. Both algorithms ran on iPancreas comprising commercial glucose sensors, insulin pumps, and smartwatches. Participants executed 1 week run-in on usual therapy followed by exAPD or exMPC for one 12 h primary in-clinic session involving meals, exercise, and activities of daily living, and 2 free-living out-patient days. Primary outcome was time below range (<3·9 mmol/L) during the primary in-clinic session. Secondary outcome measures included mean glucose and time in range (3·9-10 mmol/L). This trial is registered with ClinicalTrials.gov, NCT04771403. FINDINGS: Between April 13, 2021, and Oct 3, 2022, 27 participants (18 females) were enrolled into the study. There was no significant difference between exMPC (n=24) versus exAPD (n=22) in time below range (mean [SD] 1·3% [2·9] vs 2·5% [7·0]) or time in range (63·2% [23·9] vs 59·4% [23·1]) during the primary in-clinic session. In the 2 h period after start of in-clinic exercise, exMPC had significantly lower mean glucose (7·3 [1·6] vs 8·0 [1·7] mmol/L, p=0·023) and comparable time below range (1·4% [4·2] vs 4·9% [14·4]). Across the 76 h study, both algorithms achieved clinical time in range targets (71·2% [16] and 75·5% [11]) and time below range (1·0% [1·2] and 1·3% [2·2]), significantly lower than run-in period (2·4% [2·4], p=0·0004 vs exMPC; p=0·012 vs exAPD). No adverse events occurred. INTERPRETATION: AIDs can integrate exercise data from smartwatches to inform insulin dosing and limit hypoglycaemia while improving glucose outcomes. Future AID systems that integrate exercise metrics from wearable fitness sensors may help people living with type 1 diabetes exercise safely by limiting hypoglycaemia. FUNDING: JDRF Foundation and the Leona M and Harry B Helmsley Charitable Trust, National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Dispositivos Eletrônicos Vestíveis , Feminino , Humanos , Atividades Cotidianas , Inteligência Artificial , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose/uso terapêutico , Gastos em Saúde , Hipoglicemiantes/uso terapêutico , Insulina , Estados Unidos , Masculino
3.
Diabetes Technol Ther ; 24(12): 892-897, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35920839

RESUMO

Introduction: DailyDose is a decision support system designed to provide real-time dosing advice and weekly insulin dose adjustments for adults living with type 1 diabetes using multiple daily insulin injections. Materials and Methods: Twenty-five adults were enrolled in this single-arm study. All participants used Dexcom G6 for continuous glucose monitoring, InPen for short-acting insulin doses, and Clipsulin to track long-acting insulin doses. Participants used DailyDose on an iPhone for 8 weeks. The primary endpoint was % time in range (TIR) comparing the 2-week baseline to the final 2-week period of DailyDose use. Results: There were no significant differences between TIR or other glycemic metrics between the baseline period compared to final 2-week period of DailyDose use. TIR significantly improved by 6.3% when more than half of recommendations were accepted and followed compared with 50% or fewer recommendations (95% CI 2.5%-10.1%, P = 0.001). Conclusions: Use of DailyDose did not improve glycemic outcomes compared to the baseline period. In a post hoc analysis, accepting and following recommendations from DailyDose was associated with improved TIR. Clinical Trial Registration Number: NCT04428645.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Glicemia , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/análise
4.
Nat Metab ; 2(7): 612-619, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32694787

RESUMO

Type 1 diabetes (T1D) is characterized by pancreatic beta cell dysfunction and insulin depletion. Over 40% of people with T1D manage their glucose through multiple injections of long-acting basal and short-acting bolus insulin, so-called multiple daily injections (MDI)1,2. Errors in dosing can lead to life-threatening hypoglycaemia events (<70 mg dl-1) and hyperglycaemia (>180 mg dl-1), increasing the risk of retinopathy, neuropathy, and nephropathy. Machine learning (artificial intelligence) approaches are being harnessed to incorporate decision support into many medical specialties. Here, we report an algorithm that provides weekly insulin dosage recommendations to adults with T1D using MDI therapy. We employ a unique virtual platform3 to generate over 50,000 glucose observations to train a k-nearest neighbours4 decision support system (KNN-DSS) to identify causes of hyperglycaemia or hypoglycaemia and determine necessary insulin adjustments from a set of 12 potential recommendations. The KNN-DSS algorithm achieves an overall agreement with board-certified endocrinologists of 67.9% when validated on real-world human data, and delivers safe recommendations, per endocrinologist review. A comparison of inter-physician-recommended adjustments to insulin pump therapy indicates full agreement of 41.2% among endocrinologists, which is consistent with previous measures of inter-physician agreement (41-45%)5. In silico3,6 benchmarking using a platform accepted by the United States Food and Drug Administration for evaluation of artificial pancreas technologies indicates substantial improvement in glycaemic outcomes after 12 weeks of KNN-DSS use. Our data indicate that the KNN-DSS allows for early identification of dangerous insulin regimens and may be used to improve glycaemic outcomes and prevent life-threatening complications in people with T1D.


Assuntos
Inteligência Artificial , Sistemas de Apoio a Decisões Clínicas , Diabetes Mellitus Tipo 1/tratamento farmacológico , Adulto , Algoritmos , Glicemia/análise , Simulação por Computador , Gerenciamento Clínico , Controle Glicêmico , Humanos , Hiperglicemia/sangue , Hipoglicemia/sangue , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/sangue , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/sangue , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Reprodutibilidade dos Testes
5.
J Diabetes Sci Technol ; 13(6): 1044-1053, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31595784

RESUMO

BACKGROUND: People with type 1 diabetes (T1D) have varying sensitivities to insulin and also varying responses to meals and exercise. We introduce a new adaptive run-to-run model predictive control (MPC) algorithm that can be used to help people with T1D better manage their glucose levels using an artificial pancreas (AP). The algorithm adapts to individuals' different insulin sensitivities, glycemic response to meals, and adjustment during exercise as a continuous input during free-living conditions. METHODS: A new insulin sensitivity adaptation (ISA) algorithm is presented that updates each patient's insulin sensitivity during nonmeal periods to reduce the error between the actual glucose levels and the process model. We further demonstrate how an adaptive learning postprandial hypoglycemia prevention algorithm (ALPHA) presented in the previous work can complement the ISA algorithm, and the algorithm can adapt in several days. We further show that if physical activity is incorporated as a continuous input (heart rate and accelerometry), performance is improved. The contribution of this work is the description of the ISA algorithm and the evaluation of how ISA, ALPHA, and incorporation of exercise metrics as a continuous input can impact glycemic control. RESULTS: Incorporating ALPHA, ISA, and physical activity into the MPC improved glycemic outcome measures. The adaptive learning postprandial hypoglycemia prevention algorithm combined with ISA significantly reduced time spent in hypoglycemia by 71.7% and the total number of rescue carbs by 67.8% to 0.37% events/day/patient. Insulin sensitivity adaptation significantly reduced model-actual mismatch by 12.2% compared to an AP without ISA. Incorporating physical activity as a continuous input modestly improved time in the range 70 to 180 mg/dL during high physical activity days from 84.4% to 84.9% and reduced the percentage time in hypoglycemia by 23.8% from 2.1% to 1.6%. CONCLUSION: Adapting postprandial insulin delivery, insulin sensitivity, and adapting to physical exercise in an MPC-based AP systems can improve glycemic outcomes.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Frequência Cardíaca/fisiologia , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Pâncreas Artificial , Acelerometria , Algoritmos , Simulação por Computador , Diabetes Mellitus Tipo 1/sangue , Exercício Físico/fisiologia , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Modelos Biológicos , Período Pós-Prandial
SELEÇÃO DE REFERÊNCIAS