Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 218
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1287-1297, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504509

RESUMO

PURPOSE: The present study focuses on testing the capability of a restricted tibia-first, gap-balanced patient-specific alignment technique (PSA) to restore bony morphology and phenotypes. METHODS: Three-hundred and sixty-seven patients were treated with navigated total knee arthroplasty and tibia-first gap-balanced PSA technique. Boundaries for medial proximal tibial angle were 86°-92°, mechanical lateral distal femoral angle 86°-92°, and hip-knee-ankle angle 175°-183°. Knees were classified by coronal plane alignment of the knee (CPAK), with subsequent analyses comparing pre- and postoperative distributions. Phenotype classification within CPAK groups assessed pre- and postoperative distributions. RESULTS: Preoperatively, the largest CPAK group was type II (30.8%), followed by type I (20.5%) and type V (17.8%). Postoperatively, type II remained the largest group (39%), followed by type V (30%). All groups with varus/valgus deformities (I, III, IV and VI) became smaller. While in straight legs (II, IV), the CPAK was restored in more than 70%-75%, in varus groups (I, IV) in 40%-50% and in valgus (III and VI) in 5%-18%. The joint line obliquity remained the same in the majority of knees (straight >75%; varus 63%-80%; valgus VI 95%), with the exception of CPAK III (40%). The phenotype analysis showed for straight legs a phenotype restoration of 85%, for varus 94% and for valgus 37%. Joint line convergence angle was reduced significantly in all groups from 1.8°-4.3° preoperatively to 0.6°-1.2° postoperatively. CONCLUSION: PSA restores bony phenotypes and joint line obliquity in the majority of straight and varus knees, while most of the valgus and extreme varus knees are normalised. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Artroplastia do Joelho , Articulação do Joelho , Fenótipo , Tíbia , Humanos , Masculino , Feminino , Artroplastia do Joelho/métodos , Idoso , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Pessoa de Meia-Idade , Tíbia/cirurgia , Mau Alinhamento Ósseo , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Cirurgia Assistida por Computador/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38415864

RESUMO

PURPOSE: To identify gender differences in (1) the coronal alignment of functional knee phenotypes and (2) the JLCA (joint line convergence angle) in relation to the phenotype classification. METHODS: This study is a retrospective data analysis, including 12,099 osteoarthritic knee computed tomography (5025 male, 7074 female) analysed by Medacta software for hip-knee-ankle angle (HKA), femoral mechanical angle (FMA), tibial mechanical angle (TMA) and JLCA. The data were grouped into genders and combined according to the Functional Knee Phenotypes Classification. RESULTS: Out of 127 phenotypes for males and 131 for females, 17 common phenotypes were reported. The commonest four were similar for both genders with VARHKA177° NEUFMA93° NEUTMA87° (9.8% males, 9.50% females), followed by VARHKA174° NEUFMA93°VARTMA84° (7.1%) and VARHKA174°VARFMA90° NEUTMA87° (7.0%) for males and VARHKA174° NEUFMA93° NEUTMA87° (6.1%), VARHKA174° NEUFMA93°VARTMA84° (5.1%) for females. The commonest FMA and TMA (91.5° to 94.5° and 85.5° to 88.5°, respectively) were the same for both genders, however, the rest of the male population observed greater femoral varus than the female population (p < 0.001). JLCA values ranged from -28.4° to 8.2° in the overall study population. Males and females had a mean JLCA of -2.96° (±2.6° SD) and -2.66° (±2.8°7 SD), respectively, p < 0.001. CONCLUSIONS: Gender differences exist within the osteoarthritic knee phenotype. The male varus phenotype is influenced by FMA, while TMA values are similar across genders. JLCA variations show similarities to both TMA and FMA, suggesting JLCA is influenced by bone morphology more than by gender. These differences inform surgical decision-making for the personalised approach to the primary TKA. LEVEL OF EVIDENCE: Level III.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38984905

RESUMO

PURPOSE: Patient dissatisfaction rates following total knee arthroplasty (TKA) reported in the literature reach 20%. The optimal coronal alignment is still under debate. The aim of this retrospective study was to compare clinical outcomes in different coronal plane alignment of the knee (CPAK) phenotypes undergoing mechanically aligned (MA) TKA. The hypothesis was that knees with preoperative varus arithmetic hip-knee-ankle angle (aHKA) would achieve inferior clinical outcomes after surgery compared to other aHKA categories. Additionally, another objective was to assess CPAK phenotypes distribution in the study population. METHODS: A retrospective selection was made of 180 patients who underwent MA TKA from April 2021 to December 2022, with a 1-year follow-up. Coronal knee alignment was classified according to the CPAK classification. Clinical outcome evaluations were measured using the Knee Society Score (KSS), Oxford Knee Score (OKS), Short Form Survey 12 and Forgotten Joint Score (FJS). Differences in clinical outcomes were considered statistically significant with a p value <0 .05. RESULTS: Patients with varus aHKA achieved significantly inferior outcomes at final follow-up compared to other aHKA categories in KSS pt. 1 (79.7 ± 17.2 vs. 85.6 ± 14.7; p = 0.028), OKS (39.2 ± 9.2 vs. 42.2 ± 7.2; p = 0.019) and FJS (75.4 ± 31.0 vs. 87.4 ± 22.9; p =0 .003). The most common aHKA category was the varus category (39%). The most common CPAK phenotypes were apex distal Types I (23.9%), II (22.8%) and III (13.3%). CONCLUSION: MA TKA does not yield uniform outcomes across all CPAK phenotypes. Varus aHKA category shows significantly inferior results at final follow-up. The most prevalent CPAK categories are varus aHKA and apex distal JLO, with phenotypes I, II and III being the most common. However, their gender distribution varies significantly. LEVEL OF EVIDENCE: Level IV.

4.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 473-489, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38293728

RESUMO

PURPOSE: One of the most pertinent questions in total knee arthroplasty (TKA) is: what could be considered normal coronal alignment? This study aims to define normal, neutral, deviant and aberrant coronal alignment using large data from a computed tomography (CT)-scan database and previously published phenotypes. METHODS: Coronal alignment parameters from 11,191 knee osteoarthritis (OA) patients were measured based on three dimensional reconstructed CT data using a validated planning software. Based on these measurements, patients' coronal alignment was phenotyped according to the functional knee phenotype concept. These phenotypes represent an alignment variation of the overall hip knee ankle angle (HKA), femoral mechanical angle (FMA) and tibial mechanical angle (TMA). Each phenotype is defined by a specific mean and covers a range of ±1.5° from this mean. Coronal alignment is classified as normal, neutral, deviant and aberrant based on distribution frequency. Mean values and distribution among the phenotypes are presented and compared between two populations (OA patients in this study and non-OA patients from a previously published study). RESULTS: The arithmetic HKA (aHKA), combined normalised data of FMA and TMA, showed that 36.0% of knees were neutral within ±1 SD from the mean in both angles, 44.3% had either a TMA or a FMA within ±1-2 SD (normally aligned), 15.3% of the patients were deviant within ±2-3 SD and only 4.4% of them had an aberrant alignment (±3-4 SD in 3.4% and >4 SD in 1.0% of the patients respectively). However, combining the normalised data of HKA, FMA and TMA, 15.4% of patients were neutral in all three angles, 39.7% were at least normal, 27.7% had at least one deviant angle and 17.2% had at least one aberrant angle. For HKA, the males exhibited 1° varus and females were neutral. For FMA, the females exhibited 0.7° more valgus in mean than males and grew 1.8° per category (males grew 2.1° per category). For TMA, the males exhibited 1.3° more varus than females and both grew 2.3° and 2.4° (females) per category. Normal coronal alignment was 179.2° ± 2.8-5.6° (males) and 180.5 > ± 2.8-5.6° (females) for HKA, 93.1 > ± 2.1-4.2° (males) and 93.8 > ± 1.8-3.6° (females) for FMA and 86.7 > ± 2.3-4.6° (males) and 88 > ± 2.4-4.8° (females) for TMA. This means HKA 6.4 varus or 4.8° valgus (males) or 5.1° varus to 6.1° valgus was considered normal. For FMA HKA 1.1 varus or 7.3° valgus (males) or 0.2° valgus to 7.4° valgus was considered normal. For TMA HKA 7.9 varus or 1.3° valgus (males) or 6.8° varus to 2.8° valgus was considered normal. Aberrant coronal alignment started from 179.2° ± 8.4° (males) and 180.5 > ± 8.4° (females) for HKA, 93.1 > ± 6.3° (males) 93.8 > ± 5.4° (females) for FMA and 86.7 > ± 6.9° (males) and 88 > ± 7.2° (females) for TMA. This means HKA > 9.2° varus or 7.6° valgus (males) or 7.9° varus to 8.9° valgus was considered aberrant. CONCLUSION: Definitions of neutrality, normality, deviance as well as aberrance for coronal alignment in TKA were proposed in this study according to their distribution frequencies. This can be seen as an important first step towards a safe transition from the conventional one-size-fits-all to a more personalised coronal alignment target. There should be further definitions combining bony alignment, joint surfaces' morphology, soft tissue laxities and joint kinematics. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Masculino , Feminino , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Extremidade Inferior , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fêmur/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
5.
J Arthroplasty ; 39(3): 591-599, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38007204

RESUMO

Mechanical alignment (MA) and its tenets have been considered essential for total knee arthroplasty (TKA) success since they were introduced in 1973. However, over time, there have been colossal advances in our knowledge and understanding of the anatomy and kinematics of the knee, as well as in surgical precision and implants. However, the MA systematic principles of prosthetic arthroplasty and implant position related to the lower-extremity mechanical axis, have only recently been called into question. The high rates of dissatisfaction and residual pain reported after MA TKA prompted this questioning, and that leaves plenty of room for improvement. Despite the general consensus that there is great variability between patients' anatomy, it is still the norm to carry out a systematic operation that does not consider individual variations. Evolving to a more personalized arthroplasty surgery was proposed as a rational and reasonable option to improve patient outcomes. Transitioning to a personalized TKA approach requires questioning and even disregarding certain MA TKA principles. Based on current knowledge, we can state that certain principles are erroneous or unfounded. The aim of this narrative review was to discuss and challenge 10 previously accepted, yet we believe, flawed, principles of MA, and to present an alternative concept, which is rooted in personalized TKA techniques.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/anatomia & histologia , Extremidade Inferior/cirurgia , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia
6.
Int Orthop ; 48(2): 401-408, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37668725

RESUMO

PURPOSE: External snapping hip syndrome (ESHS) was historically attributed to isolated iliotibial band (ITB) contracture. However, the gluteus maximus complex (GMC) may also be involved. This study aimed to intraoperatively identify the ESHS origin and assess the outcomes of endoscopic treatment based on the identified aetiological type. METHODS: From 2008-2014, 30 consecutive patients (34 hips) with symptomatic ESHS cases refractory to conservative treatment underwent endoscopic stepwise "fan-like" release, gradually addressing all known reasons of ESHS: from the isolated ITB, through the fascial part of the GMC until a partial release of gluteus maximus femoral attachment occurred. Snapping was assessed intra-operatively after each surgical step and prospectively recorded. Functional outcomes were assessed via the MAHORN Hip Outcome Tool (MHOT-14). RESULTS: Twenty seven patients (31 hips) were available to follow-up at 24-56 months. In all cases, complete snapping resolution was achieved intra-operatively: in seven cases (22.6%) after isolated ITB release, in 22 cases (70.9%), after release of ITB + fascial part of the GMC, and in two cases (6.5%) after ITB + fascial GMC release + partial release of GM femoral insertion. At follow-up, there were no snapping recurrences and MHOT-14 score significantly increased from a pre-operative average of 46 to 93(p<0.001). CONCLUSION: Intraoperative identification and gradual addressing of all known causes of ESHS allows for maximum preservation of surrounding tissue during surgery while precisely targeting the directly involved structures. Endoscopic stepwise "fan-like" release of the ITB and GMC is an effective, tailor-made treatment option for ESHS regardless of the snapping origin in the patients with possibility to manually reproduce the snapping.


Assuntos
Contratura , Artropatias , Humanos , Articulação do Quadril/cirurgia , Artropatias/cirurgia , Endoscopia/efeitos adversos , Músculo Esquelético/cirurgia , Contratura/cirurgia , Síndrome
7.
J Orthop Traumatol ; 25(1): 12, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430413

RESUMO

BACKGROUND: Alumina particles from the grit blasting of Ti-alloy stems are suspected to contribute to aseptic loosening. An alumina-reduced stem surface was hypothesized to improve osseointegration and show comparable short-term outcomes to those of a standard stem. METHODS: In this prospective, double-blind, randomized trial, 26 standard (STD) and 27 experimental new technology (NT) stems were implanted. The latter were additionally treated by acid etching and ice blasting to remove alumina particles from the grit-blasting process. Follow-up occurred at 12 and 24 months. Bone mineral density (BMD) around the stem was measured by a dual-energy x-ray absorptiometry device (DEXA). Radiographs were reviewed for alterations. Clinical scoring comprised the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Harris Hip Score (HHS). Survival rates were calculated up to 50 months. RESULTS: Lower mean BMD and more severe cortical hypertrophies were found in the NT group. At 12 months, radiolucent lines were observed mostly in the metaphyseal zone for both groups, with a progression tendency in the NT group at 24 months. At 12 months, pain scores and the WOMAC total and physical activity scores were significantly lower in the NT group, without any differences thereafter. The number of NT stem revisions amounted to 6 (24%) and 11 (41%) at 24 and 50 months, respectively. CONCLUSION: In the NT group, unexpected catastrophic failure rates of 41% caused by early aseptic loosening were noted within 50 months. Compared with the STD stems, NT stems lead to poor clinical and radiographic results. LEVEL OF EVIDENCE: II. TRIAL REGISTRATION: NCT05053048.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Absorciometria de Fóton , Óxido de Alumínio , Artroplastia de Quadril/métodos , Seguimentos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Método Duplo-Cego
8.
BMC Musculoskelet Disord ; 24(1): 431, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37254174

RESUMO

BACKGROUND: Quadriceps tendon rupture (QTR) is a severe injury of the knee extensor apparatus. The study aims to validate the use of forgotten joint score (FJS-12) for functional outcome assessing after surgical treatment of QTR. METHODS: Fifty-seven patients who underwent surgery for QTR with transosseous suture reconstruction in a single orthopaedic surgery and traumatology center between 2015 and 2020 were eligible for enrolment in this retrospective case series. The demographic data and other pre-operative details such as age, gender, comorbidities and medication use also were extracted from the medical records. Patient reported outcome measures (PROMs) were gathered in the form of Western Ontario and McMaster Universities Arthritis Index Score (WOMAC), Tegner Activity Score (TAS), Lysholm Score and FJS-12 at a mean follow-up time of 49.84 months ± 20.64 months. The FJS-12 was validated by correlation with WOMAC, TAS and Lysholm Score. RESULTS: The mean age of all patients were 69.2 ± 13.6 years with 51 (89.5%) males and 6 (10.5%) females. The mean time from injury to surgery was 3.39 ± 5.46 days. All patients reported satisfactory functional outcomes after surgery on FJS-12, WOMAC and Lysholm scores, except the TAS, which decreased slightly from pre-operative level. There was a high negative correlation between WOMAC and FJS-12, but moderate positive correlations between FJS-12 and TAS and Lysholm scores. The Cronbach's alpha value was 0.96 for 12 items in FJS-12. CONCLUSION: This study has found that FJS-12 is a reliable and easy to assess tool for functional outcomes after QTR reconstruction. It has shown moderate to strong correlation with other commonly used outcome measures (WOMAC, TAS and Lysholm).


Assuntos
Artroplastia do Joelho , Traumatismos dos Tendões , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Tendões/cirurgia , Traumatismos dos Tendões/diagnóstico , Traumatismos dos Tendões/cirurgia
9.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 768-776, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35678853

RESUMO

PURPOSE: Navigated, gap-balanced adjusted mechanical alignment (AMA) including a 0° varus tibial cut and modification of angles and resections of the femoral cuts to obtain optimal balance accepting minor axis deviations. Objectives of this study were (1) to analyse to what extent AMA achieves the goals for leg alignment and gap balance, and (2) in what percentage non-anatomical cuts are needed to achieve these goals. METHODS: Out of 1000 total knee arthroplasties (TKA) all varus knees (hip-knee-ankle (HKA) angle < 178°; n = 680) were included. All surgeries were performed as computer assisted surgery (CAS) in AMA technique. CAS data at the end of surgery were analysed with respect to HKA and gap-sizes. All bone cuts were quantified. Depending on the amount of deformity, a subgroup analysis was performed. It was analysed whether the amount of deformity influences the non-anatomical cuts by correlation analysis. RESULTS: AMA reached the goals for postoperative HKA (3° corridor) in 636 cases (93.5%). While extension and flexion gap balance were achieved in more than 653 cases (96%), flexion and extension gap size were equalled in 615 knees (90.4%). The resections of the lateral tibia plateau and distal and posterior medial femoral condyle were anatomical (Tibia: 7.0 ± 1.7 mm; medial condyle distal: 7.8 ± 1.4 mm; medial posterior: 8.2 ± 1.8 mm). The number of non-anatomical resections for those cuts were low; 67 (9.9%); 24 (3.5%); 32 (4.7%). For the medial tibia plateau and the lateral posterior condyle, the cuts were non-anatomical in a high percentage of cases; Tibia: 606 (89.1%), lateral posterior condyle: 398 (58.5%). Moderate but significant correlations were found between resection differences and amount of deformity (medio-lateral: tibia: 0.399; distal femur: 0.310; posterior femur: 0.167). No correlations were found between resection differences and gap values. CONCLUSION: AMA reaches the intended target for HKA and gap balance in over 612 (90%) of cases and maintains the medial femoral condyle anatomically. Non-anatomical tibial resection causes increased external rotation of the femoral component and by that non-anatomical cut of the posterior lateral condyle. Nonanatomical resections of AMA might be one reason for the persisting high rate of unsatisfied patients after TKA. Anatomical and individual alignment philosophies might help to reduce this rate of dissatisfaction.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Objetivos , Articulação do Joelho/cirurgia , Artroplastia do Joelho/métodos , Tíbia/cirurgia , Fêmur/cirurgia , Amplitude de Movimento Articular , Osteoartrite do Joelho/cirurgia
10.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3784-3791, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36807723

RESUMO

PURPOSE: The technique of adjusted mechanical alignment (AMA) in total knee arthroplasty (TKA) has been described to achieve alignment and balancing goals in varus knees in a high percentage, albeit at the price of non-anatomical bone cuts. The purpose of this study was to analyze (1) whether AMA achieves similar alignment and balancing results in different types of deformity and (2) whether they can be achieved without altering the native anatomy. METHODS: A series of 1000 patients with hip-knee-ankle (HKA) angles from 165° to 195° were analyzed. All patients were operated using AMA technique. According to the preoperative HKA angle, three groups of knee phenotypes (varus, straight, valgus) were defined. The bone cuts were analyzed for being anatomic (< 2 mm deviation of individual joint surface) or non-anatomic (> 4 mm deviation of individual joint surface). RESULTS: AMA reached the goals for postoperative HKA in over 93% in every group (varus: 636 cases, 94%, straight: 191 cases, 98%, valgus: 123 cases, 98%). In 0° extension, the gaps were balanced in varus knees in 654 cases (96%), in straight knees in 189 cases (97%) and in valgus knees in 117 cases (94%). A balanced flexion gap was found in a similar number of cases (varus: 657 cases, 97%, straight: 191 cases, 98%, valgus: 119 cases, 95%). In the varus group, non-anatomical cuts were performed at the medial tibia (89%) and the lateral posterior femur (59%). The straight group showed similar values and distribution for non-anatomical cuts (medial tibia: 73%; lateral posterior femur 58%). Valgus knees showed a different distribution of values, being non-anatomical at the lateral tibia (74%), distal lateral femur (67%) and posterior lateral femur (43%). CONCLUSION: In all knee phenotypes, the AMA goals were achieved in a high percentage by altering the patients' native anatomy. In varus knees, the alignment was corrected by non-anatomical cuts at the medial tibia, and in valgus knees at the lateral tibia and the lateral distal femur. All phenotypes showed non-anatomical resections on the posterior lateral condyle in approximately 50% of cases. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Tíbia/cirurgia , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Artroplastia do Joelho/métodos , Extremidade Inferior/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
11.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3927-3940, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37005940

RESUMO

PURPOSE: The aim of this study was to report the clinical and functional outcomes, complication rates, implant survivorship and the progression of tibiofemoral osteoarthritis (OA), after new inlay or onlay patellofemoral arthroplasty (PFA), for isolated patellofemoral OA. Comparison of different implant types and models, where it was possible, also represented one of the objectives. METHODS: A systematic literature search following PRISMA guidelines was conducted on PubMed, Scopus, Embase and Cochrane databases, to identify possible relevant studies, published from the inception of these databases until 11.11.2022. Randomized control trials (RCTs), case series, case control studies and cohort studies, written in English or German, and published in peer-reviewed journals after 2010, were included. Not original studies, case reports, simulation studies, systematic reviews, or studies that included patients who underwent TKA or unicompartmental arthroplasty (UKA) of the medial or lateral compartment of the knee, were excluded. Additionally, only articles that assessed functional and/or clinical outcomes, patient-reported outcomes (PROMs), radiographic progression of OA, complication rates, implant survival rates, pain, as well as conversion to TKA rates in patients treated with PFA, using inlay or onlay trochlea designs, were included. For quality assessment, the Methodological Index for Non-Randomized Studies (MINORS) for non-comparative and comparative clinical intervention studies was used. RESULTS: The literature search identified 404 articles. 29 of them met all the inclusion criteria following the selection process. Median MINORS for non-comparative studies value was 12.5 (range 11-14), and for comparative studies 20.1 (range 17-24). In terms of clinical and functional outcomes, no difference between onlay and inlay PFA has been described. Both designs yielded satisfactory results at short, medium and long-term follow-ups. Both designs improved pain postoperatively and no difference between them in terms of postoperative VAS has been noted, although the onlay groups presented a higher preoperative VAS. When comparing the inlay to onlay trochlea designs, the inlay group displayed a lower progression of OA rate. CONCLUSION: There is no difference in functional or clinical outcomes after PFA between the new inlay and the onlay designs, with both presenting an improvement in most of the scores that were used. A higher rate of OA progression was observed in the onlay design group. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Articulação Patelofemoral , Humanos , Artroplastia do Joelho/métodos , Resultado do Tratamento , Osteoartrite do Joelho/cirurgia , Dor/cirurgia , Articulação Patelofemoral/cirurgia
12.
Knee Surg Sports Traumatol Arthrosc ; 31(5): 1851-1858, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36854996

RESUMO

PURPOSE: The aim of this systematic review was to investigate the clinical and functional knee outcomes after Verasense sensor-assisted total knee arthroplasty (VA TKA), and to compare these outcomes, where possible, with those from manually balanced total knee arthroplasty (MB TKA). METHODS: A systematic literature search following PRISMA guidelines was conducted on PubMed, Embase, Medline and Scopus from the beginning of January 2012 until the end of June 2022, to identify potentially relevant articles for this review. Selection was based on the following inclusion criteria: full text English- or German-language clinical studies, published in peer-reviewed journals, which assessed clinical and functional outcomes following VA TKA. Not original research, preprints, abstract-only papers, protocols, reviews, expert opinion papers, book chapters, surgical technique papers, and studies pertaining only to unicondylar knee arthroplasty (UKA) or patellofemoral arthroplasty (PFA) were excluded. Several scores (Knee Society Score [KSS], Oxford Knee Score [OKS], Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC], Knee injury and Osteoarthritis Outcome Score-4 subscales [KOOS4] and Physical Function-Computerised Adaptive Testing [PF-CAT]), alongside postoperative measurements of range of motion [ROM], reoperation rates and the rate of manipulation under anaesthesia [MUA]) were used to evaluate clinical and functional outcomes. The quality of included papers, except randomised control trials (RCTs), was evaluated using the Methodological Index for Non-Randomised Studies (MINORS). For the assessment of included RCTs, the Jadad Scale was used. RESULTS: The literature search identified 243 articles. After removing duplicates, 184 papers were included in the initial screening process. Fourteen of them met all the inclusion criteria following the selection process. Mean MINORS for non-comparative studies value was 11.5 (11-12), and for comparative studies 18.2 (13-21). Mean Jadad Scale score was 3.6 (2-5). Outcomes from a total number of 3633 patients were evaluated (mean age at surgery 68.5 years [32-88 years]). In terms of clinical outcomes, the overwhelming majority of studies observed an improvement after VA TKA, but no statistically significant difference in ROM and reoperation rate when compared to MB TKA. On the other hand, lower rates of MUA have been described in the VA TKA group. An increase in postoperative clinical and functional scores values, when compared to the preoperative ones, has been reported in both groups, although no statistically significant difference between them has been observed. CONCLUSION: The use of Verasense pressure sensors in TKA leads to no significant improvement in ROM, reoperation rate or functional outcomes, when compared to the standard manually balancing technique. However, lower rates of MUA have been described in the VA TKA group. These findings highlight the importance of tools being able to measure ligament stresses or joint pressure for achieving an optimally balanced knee. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Reoperação , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular
13.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4631-4636, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792083

RESUMO

Peer review is an essential process to ensure that scientific articles meet high standards of methodology, ethics and quality. The peer-review process is a part of the academic mission for physicians in the university setting. The work of reviewers is of great value for authors, as it gives constructive criticism and improves manuscript quality before publication. Often, however, reviews are of suboptimal quality. Usually, reviewers do not receive formal training either on how to perform a review or on the peer-review process. In addition, it is generally believed that experienced authors are great reviewers, but this may not always be true. The overarching goal of a review is to make the manuscript better; to help the authors. The purpose of this article is to offer relevant suggestions and provide a checklist on how to perform a useful review.


Assuntos
Lista de Checagem , Revisão por Pares , Humanos , Revisão da Pesquisa por Pares/métodos
14.
Knee Surg Sports Traumatol Arthrosc ; 31(5): 1840-1850, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36811657

RESUMO

PURPOSE: The purpose of this study was to visualise the influence of alignment strategy on bone resection in varus knee phenotypes. The hypothesis was that different amounts of bone resection would be required depending on the alignment strategy chosen. Through visualisation of the corresponding bone sections, it was hypothesised, it would be possible to assess which of the different alignment strategies would require the least amount of change to the soft tissues for the chosen phenotype, whilst still ensuring acceptable alignment of the components, and thus could be considered the most ideal alignment strategy. METHODS: Simulations of the different alignment strategies (mechanical, anatomical, constrained kinematic and unconstrained kinematic) in relation to their bone resections were performed on five common exemplary varus knee phenotypes. VARHKA174° VARFMA87° VARTMA84°, VARHKA174° VARFMA90° NEUTMA87°, VARHKA174° NEUFMA93° VARTMA84°, VARHKA177° NEUFMA93° NEUTMA87° and VARHKA177° VALFMA96° VARTMA81°. The phenotype system used categorises knees based on overall limb alignment (i.e. hip knee angle) but also takes into account joint line obliquity (i.e. TKA and FMA) and has been applied in the global orthopaedic community since its introduction in 2019. The simulations are based on long-leg radiographs under load. It is assumed that a change of 1° in the alignment of the joint line corresponds to a displacement of the distal condyle by 1 mm. RESULTS: In the most common phenotype VARHKA174° NEUFMA93° VARTMA84°, a mechanical alignment would result in an asymmetric elevation of the tibial medial joint line by 6 mm and a lateral distalisation of the femoral condyle by 3 mm, an anatomical alignment only by 0 and 3 mm, a restricted by 3 and 3 mm, respectively, whilst a kinematic alignment would result in no change in joint line obliquity. In the similarly common phenotype 2 VARHKA174° VARFMA90° NEUTMA87° with the same HKA, the changes are considerably less with only 3 mm asymmetric height change on one joint side, respectively, and no change in restricted or kinematic alignment. CONCLUSION: This study shows that significantly different amounts of bone resection are required depending on the varus phenotype and the alignment strategy chosen. Based on the simulations performed, it can, therefore, be assumed that an individual decision for the respective phenotype is more important than the dogmatically correct alignment strategy. By including such simulations, the modern orthopaedic surgeon can now avoid biomechanically inferior alignments and still obtain the most natural possible knee alignment for the patient.


Assuntos
Artroplastia do Joelho , Fraturas Ósseas , Humanos , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fenótipo , Fraturas Ósseas/cirurgia
15.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1267-1275, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36326877

RESUMO

PURPOSE: The purpose of this study was to simulate and visualise the influence of the alignment strategy on bone resection in neutral knee phenotypes. It was hypothesised that different amounts of bone resection would be required depending on the alignment strategy chosen. The hypothesis was that by visualising the corresponding bone cuts, it would be possible to assess which of the different alignment strategies required the least change to the soft tissues for the chosen phenotype but still ensured acceptable component alignment and could, therefore, be considered the most ideal alignment strategy. METHODS: Simulations of the different alignment strategies (mechanical, anatomical, restricted kinematic and unrestricted kinematic) regarding their bone resections were performed on four common exemplary neutral knee phenotypes. NEUHKA0° VARFMA 90° VALTMA90°, NEUHKA0° NEUFMA 93° NEUTMA87°, NEUHKA0° VALFMA 96° NEUTMA87° and NEUHKA0° VALFMA 99° VARTMA84°. The phenotype system used categorises knees based on overall limb alignment (i.e. hip knee angle) but also considers joint line obliquity (i.e. TKA and FMA) and has been used globally since its introduction in 2019. These simulations are based on long leg weightbearing radiographs. It is assumed that a change of 1° in the alignment of the joint line corresponds to correspond to 1 mm of distal condyle offset. RESULTS: In the most common neutral phenotype NEUHKA0° NEUFMA 93° NEUTMA87°, with a prevalence of 30%, bone cuts remain below 4 mm regardless of alignment strategy. The greatest changes in the obliquity of the joint line can be expected for the mechanical alignment of the phenotype NEUHKA0° VALFMA 99° VARTMA84° where the medial tibia is raised by 6 mm and the lateral femur is shifted distally by 9 mm. In contrast, the NEUHKA0° VARFMA 90° VALTMA90° phenotype requires no change in joint line obliquity if the mechanical alignment strategy is used. CONCLUSION: Illustrations of alignment strategies help the treating surgeon to estimate the postoperative joint line obliquity. When considering the alignment strategy, it seems reasonable to prefer a strategy where the joint line obliquity is changed as little as possible. Although for the most common neutral knee phenotype the choice of alignment strategy seems to be of negligible importance, in general, even for neutral phenotypes, large differences in bone cuts can be observed depending on the choice of alignment strategy.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Extremidade Inferior/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Fenótipo , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
16.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3912-3918, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36964782

RESUMO

PURPOSE: Robotic arm-assisted total knee arthroplasty (raTKA), currently a major trend in knee arthroplasty, aims to improve the accuracy of implant positioning and limb alignment. However, it is unclear whether and to what extent manual radiographic and navigation measurements with the MAKO™ system correlate. Nonetheless, a high agreement would be crucial to reliably achieve the desired limb alignment. METHODS: Thirty-six consecutive patients with osteoarthritis and a slight-to-moderate varus deformity undergoing raTKA were prospectively included in this study. Prior to surgery and at follow-up, a full leg radiograph (FLR) under weight-bearing conditions was performed. In addition, a computed tomography (CT) scan was conducted for preoperative planning. The hip-knee-ankle angle (HKA), mechanical lateral distal femur angle (mLDFA), mechanical medial proximal tibial angle (mMPTA) and joint line convergence angle (JLCA) were measured in the preoperative and follow-up FLR as well as in the CT scout (without weight-bearing) by three independent raters. Furthermore, the HKA was intraoperatively assessed with the MAKO™ system before and after raTKA. RESULTS: Significantly higher HKA values were identified for intraoperative deformity assessment using the MAKO system compared to the preoperative FLR and CT scouts (p = 0.006; p = 0.05). Intraoperative assessment of the HKA with final implants showed a mean residual varus deformity of 3.2° ± 1.9°, whereas a significantly lower residual varus deformity of 1.4° ± 1.9° was identified in the postoperative FLR (p < 0.001). The mMPTA was significantly higher in the preoperative FLR than in the CT scouts (p < 0.001). Intraoperatively, the mMPTA was adjusted to a mean of 87.5° ± 0.9° with final implants, while significantly higher values were measured in postoperative FLRs (p < 0.001). Concerning the mLDFA, no significant differences could be identified. CONCLUSION: The clinical importance of this study lies in the finding that there is a difference between residual varus deformity measured intraoperatively with the MAKO™ system and those measured in postoperative FLRs. This has implications for preoperative planning as well as intraoperative fine-tuning of the implant position during raTKA to avoid overcorrection of knees with slight-to-moderate varus osteoarthritis. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Perna (Membro) , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
17.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1323-1333, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35394135

RESUMO

PURPOSE: The number of primary total knee arthroplasties (TKA) is expected to rise constantly. For patients and healthcare providers, the early identification of risk factors therefore becomes increasingly fundamental in the context of precision medicine. Others have already investigated the detection of risk factors by conducting literature reviews and applying conventional statistical methods. Since the prediction of events has been moderately accurate, a more comprehensive approach is needed. Machine learning (ML) algorithms have had ample success in many disciplines. However, these methods have not yet had a significant impact in orthopaedic research. The selection of a data source as well as the inclusion of relevant parameters is of utmost importance in this context. In this study, a standardized approach for ML in TKA to predict complications during surgery and an irregular surgery duration using data from two German arthroplasty-specific registries was evaluated. METHODS: The dataset is based on two initiatives of the German Society for Orthopaedics and Orthopaedic Surgery. A problem statement and initial parameters were defined. After screening, cleaning and preparation of these datasets, 864 cases of primary TKA (2016-2019) were gathered. The XGBoost algorithm was chosen and applied with a hyperparameter search, a cross validation and a loss weighting to cope with class imbalance. For final evaluation, several metrics (accuracy, sensitivity, specificity, AUC) were calculated. RESULTS: An accuracy of 92.0%, sensitivity of 34.8%, specificity of 95.8%, and AUC of 78.0% were achieved for predicting complications in primary TKA and 93.4%, 74.0%, 96.3%, and 91.6% for predicting irregular surgery duration, respectively. While traditional statistics (correlation coefficient) could not find any relevant correlation between any two parameters, the feature importance revealed several non-linear outcomes. CONCLUSION: In this study, a feasible ML model to predict outcomes of primary TKA with very promising results was built. Complex correlations between parameters were detected, which could not be recognized by conventional statistical analysis. Arthroplasty-specific data were identified as relevant by the ML model and should be included in future clinical applications. Furthermore, an interdisciplinary interpretation as well as evaluation of the results by a data scientist and an orthopaedic surgeon are of paramount importance. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Ortopedia , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Aprendizado de Máquina , Medição de Risco , Fatores de Risco
18.
J Arthroplasty ; 38(7 Suppl 2): S29-S37, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36773657

RESUMO

BACKGROUND: In an effort to increase satisfaction among total knee arthroplasty (TKA) patients, emphasis has been placed on implant positioning and limb alignment. Traditionally, the aim for TKA has been to achieve a neutral mechanical alignment (MA) to maximize implant longevity. However, with the recent spike in interest in individualized alignment techniques and with the advent of new technologies, surgeons are slowly evolving away from classical MA. METHODS: This review elucidates the differences in alignment techniques for TKA, describes the concept of knee phenotypes, summarizes comparative studies between MA and individualized alignment, and provides a simple way to incorporate the latter into surgeons' practice. RESULTS: In order to manage patients by applying these strategies in day-to-day practice, a basic understanding of the aforementioned concepts is essential. Transition to an individualized alignment technique should be done gradually with caution in a stepwise approach. CONCLUSION: Alignment and implant positioning are now at the heart of the debate and surgeons are investigating a more personalized approach to TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
19.
Eur Radiol ; 32(2): 1342-1352, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34342695

RESUMO

OBJECTIVES: To evaluate the impact of diagnostic nerve block and ultrasound findings on therapeutic choices and predict the outcome after concomitant surgery in patients with suspected neuropathy of the infrapatellar branch of the saphenous nerve (IPBSN). METHODS: Fifty-five patients following knee surgery with suspicion of IPBSN neuralgia were retrospectively included. Ultrasound reports were assessed for neuroma and postsurgical scarring (yes/no). Responders and non-responders were assigned following anesthetic injection of the IPBSN. The type of procedure (neurectomy/interventional pain procedure/other than nerve-associated therapy) and pain score at initial follow-up were recorded and patients were assigned as positive (full pain relief) or negative (partial/no pain relief) to therapeutic nerve treatment. Factors associated with a relevant visual analog scale (VAS) reduction were assessed using uni- and multivariate logistic regression models and chi-square for quantitative and qualitative variables (p ≤ 0.05). RESULTS: Responders (37/55) more often had an entrapment or an evident neuroma of the IPBSN (97% vs. 6%). A positive Hoffmann-Tinel sign (p = 0.002) and the absence of knee joint instability (p = 0.029) predicted a positive response of the diagnostic nerve block (90%; 26/29). In the follow-up after therapeutic nerve treatment, all patients with full pain relief showed neuromas or entrapment of the IPBSN. Patients negatively responding to therapeutic nerve treatment more frequently showed an additional knee joint instability (25% vs. 4%). CONCLUSION: Selective denervation for neuropathic knee pain is beneficial in selected patients with significant VAS reduction after diagnostic nerve block. Non-responders following diagnostic nerve block but sonographic evidence of IPBSN pathologies need to be evaluated for other causes such as knee joint instability. KEY POINTS: • Sonographic diagnosis of neuroma or entrapment of the IPBSN is frequently seen in patients with anteromedial knee pain and leads to a good response to diagnostic nerve block following knee surgery. • The vast majority of patients with clinical signs of IPBSN neuropathy and response to a diagnostic nerve block sustained full pain relief following therapeutic nerve treatment. • Patients not responding to therapeutic IPBSN treatment have to be evaluated for other causes of anteromedial knee pain such as knee joint instability.


Assuntos
Joelho , Neuralgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Ultrassonografia
20.
BMC Musculoskelet Disord ; 23(1): 474, 2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35590296

RESUMO

BACKGROUND: With the Persona® knee system a novel anatomic total knee design was developed, which has no pre-coating, whereas the predecessor knee system is pre-coated with polymethylmethacrylate (PMMA). Joint registry data have shown no decrease in risk of aseptic revision of PMMA pre-coated tibial components compared with non-pre-coated implants. The aim of this retrieval study was to compare the amount of cement adhesions, geometry and surface features between the two knee designs and to correlate them with the underlying reason for revision surgery. METHODS: Retrieval analysis was performed of 15 NexGen® and 8 Persona® fixed-bearing knee implants from the same manufacturer retrieved from two knee revision centres. A photogrammetric method was used to grade the amount of cement attached to the tibial tray backside. The geometry and dimensions of the tibial trays, tray projections and peripheral lips were measured using digital callipers and compared between the two different designs. To measure the surface roughness on the backside of the tibial tray, a contact profilometer was used. To investigate differences between the two designs statistical analyses (t-test) were performed. RESULTS: All Persona® trays showed evidence of cement adhesion with a % area of 75.4%; half of the NexGen® trays had cement adhesions, with a mean value of 20%. There was a significant difference in the percentage of area covered by cement between the two designs (p < 0.001). Results from the contact profilometer revealed that Persona® and NexGen® tray backsides showed a similar lateral (1.36 µm and 1.10 µm) and medial (1.39 µm and 1.12 µm) mean surface roughness with significant differentiation (p < 0.05) of the lateral and medial roughness values between the two designs. Persona® stems showed a significantly higher mean surface roughness (1.26) compared to NexGen® stems (0.89; p < 0.05). CONCLUSION: The novel anatomic knee system showed significantly more cements adhesions and a higher surface roughness which was most likely attributed to the most obvious design and coating alteration of the tibial tray. This study provides first retrieval findings of a novel TKA design recently introduced to the market.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Cimentos Ósseos , Humanos , Polietileno , Polimetil Metacrilato , Desenho de Prótese , Falha de Prótese , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA