The multi-decade neutron dosimeter and imaging diagnostic (MDND) is a passive diagnostic that utilizes the polyethylene (n, p) nuclear reaction to enhance the diagnostic's sensitivity for time and energy integrated neutron measurements in the range of 2.45-14.1 MeV. The MDND utilizes a combination of radiochromic film, phosphor image plates, and solid-state nuclear track detectors, with the goal of providing several orders of magnitude of dynamic range in terms of measured neutron fluence. The diagnostic design was guided by simulations in the Monte Carlo N-Particle (MCNP) transport code to determine the optimum thickness of the polyethylene convertor for maximum proton fluence incident on the detection medium as a function of incident neutron energy. In addition, the simulation results of complete diagnostic assemblies, or "stacks," were used to determine the total dynamic range of an MDND in terms of measured neutron source yield, which was found to be between around 107 and 1015 emitted into 4π with the detector located 1 m away from the source. Complimentary to these simulations, individual detectors within a stack were simulated and analyzed to determine response as a function of neutron energy and yield. This work presents the diagnostic design, MCNP simulation results, and analysis of expected signals for varying neutron sources.
RESUMO
A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60Co (i.e., 60Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce â¼3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.
RESUMO
The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced-leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.